FM3012 -W-A01 SURFACE MOUNT GLASS PASSIVATED SILICON RECTIFIER VOLTAGE 1200 Volts CURRENT 3.0 Amperes FEATURES * * * * * * Glass passivated device Ideal for surface mounted applications Low leakage current Metallurgically bonded construction Mounting position: Any Weight: 0.24 gram SMC MECHANICAL DATA * Epoxy : Device has UL flammability classification 94V-0 * MSL: 1 Level 0.125 (3.17 ) 0.115 (2.92 ) 0.245 ( 6.22 ) 0.220 ( 5.59 ) 0.280 ( 7.11 ) 0.260 ( 6.60 ) 0.012 ( 0.305 ) 0.006 ( 0.152 ) 0.103 ( 2.62 ) 0.079 ( 2.06 ) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS 0.060 ( 1.52 ) 0.030 ( 0.76 ) 0.008 ( 0.203 ) 0.004 ( 0.102 ) Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load. 0.320 ( 8.13 ) 0.305 ( 7.75 ) Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) SYMBOL FM3012-W-A01 UNITS Maximum Recurrent Peak Reverse Voltage VRRM 1200 Volts Maximum RMS Voltage VRMS 840 Volts VDC 1200 Volts IO 3.0 Amps I FSM 100 Amps 2 IT 41.5 Typical Thermal Resistance (Note 1) RθJA RθJL Typical Junction Capacitance (Note 2) CJ 30 Operating Temperature Range TJ 150 0 C T STG -55 to + 150 0 C RATINGS Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at Ambient Temperature Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time Typical Thermal Resistance (Note 1) Storage Temperature Range 2 A S 47 0 C/W 13 0 C/W pF ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS SYMBOL Maximum Instantaneous Forward Voltage at 3.0A DC Maximum Average Reverse Current @T A = 25 o C at Rated DC Blocking Voltage @T A = 100 o C VF IR NOTES : 1. Thermal Resistance :Mounted on PCB. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant","100% Sn plating (Pb-free)". 4. Available in Halogen-free epoxy by adding suffix -HF after the part nbr. FM3012-W-A01 UNITS 1.1 Volts 2.0 µA 125 µA 2012-09 REV: O 4.0 3.0 2.0 Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375" (9.5mm) Lead Length 1.0 0 0 25 50 75 100 125 150 175 1000 INSTANTANEOUS FORWARD CURRENT, (µA) AVERAGE FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( FM3012-W-A01 ) TA = 100 OC 100 TA = 75 OC 10 1.0 TA = 25 OC 0.1 0.01 0 20 O CJ, JUNCTION CAPACITANCE, (pF) 20 10 1.0 0.1 TJ = 25 OC Pulse width=300µS 1% Duty Cycle 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 40 60 100 120 140 4.0 4.5 400 TJ = 25 OC 200 100 80 60 40 20 10 5.0 FIG.2 TYPICAL REVERSE CHARACTERISTICS 0.4 0.1 INSTANTANEOUS FORWARD VOLTAGE, (V) 1.0 4 10 40 80 REVERSE VOLTAGE, (V) FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS FIG.4 TYPICAL JUNCTION CAPACITANCE 100 8.3mS Single Half Sine-Wave JEDEC Method 80 60 40 20 0 1 80 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS REVERSE CURRENT, (A) AMBIENT TEMPERATURE, ( C) 2 4 6 8 10 20 40 80 100 NUMBER OF CYCLES AT 60Hz FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT Mounting Pad Layout 0.185 MAX. (4.69 MAX.) 0.121MIN. (3.07 MIN.) 0.060 MIN. (1.52 MIN.) 0.320 (8.127 ) REF Dimensions in inches and (millimeters) Marking Description 3 C X V Y W W Cathode Band Year – code: (Y:Last digit of year A:2010; B:2011;.....) Rectron Logo Part No. Voltage-code 1-------50V 3-------200V 5-------600V 7-------1000V Week – code: (WW:01~52) 2-------100V 4-------400V 6-------800V 12------1200V PACKAGING OF DIODE AND BRIDGE RECTIFIERS REEL PACK PACKAGE PACKING EA PER REEL CODE COMPONENT TAPE SPACE SPACE(mm) (mm) REEL DIA CARTON SIZE (mm) (mm) EA PER GROSS CARTON WEIGHT(Kg) SMC -T 500 --- --- 176 390*205*310 12,000 6.65 SMC -W 3,000 --- --- 330 355*360*350 24,000 11.50 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.