产品规格书 SPECIFICATION

规格书编号 :
SPEC NO :
产品 规 格书
SPECIFICATION
CUSTOMER 客 户:
PRODUCT 产 品:
SAW FILTER
MODEL NO 型 号:
HDF110N5 F12
PREPARED 编 制:
CHECKED 审 核:
APPROVED 批 准:
D A T E 日 期:
2011-10-9
客户确认 CUSTOMER RECEIVED:
审核 CHECKED
批准 APPROVED
日期 DATE
无锡市好达电子有限公司
Shoulder Electronics Limited
www.shoulder.cn
Tel:0755-82916880 Fax:0755-82916881
E-mail:[email protected]
Page 1 of 5
SAW FILTER
HDF110N5 F12
更改历史记录
History Record
更改日期
Date
www.shoulder.cn
规格书编号
Spec. No.
产品型号
Part No.
客户产品型号
Customer No.
Tel:0755-82916880 Fax:0755-82916881
更改内容描述
Modify Content
E-mail:[email protected]
备注
Remark
Page 2 of 5
SAW FILTER
HDF110N5 F12
1. SCOPE
This specification shall cover the characteristics of SAW filter with HDF110N5 used for the
page system.
2.1 ELECTRICAL SPECIFICATION
Maximum Input Power
DC voltage
Storage Temperature Range
Operation Temperature Range
+10dBm
10V
-45℃ to +85℃
13℃ to +45℃
2.2Electronic Characteristics
Parameter
Center Frequency
Insertion loss
-3dB Bandwidth
Rejection:
F0+/-0.5MHz—F0+/-2MHz
F0+/-2MHz—F0+/-75MHz
Min.
110.542
250
Typical.
110.592
3.5
320
30
50
35
55
Max.
110.642
4.5
MHz
dB
KHz
dB
Absolute Delay
3
3.5
Passband variation
2
2.5
Temperature Coefficient
Package Size
Unit
18
usec
dB
ppm/°C
F12
3.Typical Frequency Response
www.shoulder.cn
Tel:0755-82916880 Fax:0755-82916881
E-mail:[email protected]
Page 3 of 5
SAW FILTER
HDF110N5 F12
4.DIMENSION
5. ENVIRONMENTAL CHARACTERISTICS
5-1 High temperature exposure
Subject the device to +85℃ for 16 hours. Then release the filter into the room conditions
for 24 hours prior to the measurement. It shall fulfill the specifications in 2.2.
5-2 Low temperature exposure
Subject the device to -40℃ for 16 hours. Then release the device into the room conditions
for 24 hours prior to the measurement. It shall fulfill the specifications in 2.2.
5-3 Temperature cycling
Subject the device to a low temperature of -40℃for 30 minutes. Following by a high
temperature of +85℃ for 30 Minutes. Then release the device into the room conditions
for 24 hours prior to the measurement. It shall meet the specifications in 2.2.
5-4 Resistance to solder heat
Dip the device terminals no closer than 1.5mm into the solder bath at 260℃ ±10℃ for
10±1 sec. Then release the device into the room conditions for 4 hours. The device shall
meet the specifications in 2.2.
5-5 Solderability
Subject the device terminals into the solder bath at 245℃ ±5℃ for 5s, More than 95%
area of the terminals must be covered with new solder. It shall meet the specifications in
2.2.
5-6 Mechanical shock
Drop the device randomly onto the concrete floor from the height of 1m 3 times. the device
shall fulfill the specifications in 2.2.
5-7 Vibration
Subject the device to the vibration for 1 hour each in x,y and z axes with the amplitude
of 1.5 mm at 10 to 55 Hz. The device shall fulfill the specifications in 2.2.
www.shoulder.cn
Tel:0755-82916880 Fax:0755-82916881
E-mail:[email protected]
Page 4 of 5
SAW FILTER
HDF110N5 F12
6. REMARK
6.1 Static voltage
Static voltage between signal load & ground may cause deterioration &destruction
of the component. Please avoid static voltage.
6.2 Ultrasonic cleaning
Ultrasonic vibration may cause deterioration & destruction of the component. Please
avoid ultrasonic cleaning
6.3 Soldering
Only leads of component may be soldered. Please avoid soldering another part of
component.
www.shoulder.cn
Tel:0755-82916880 Fax:0755-82916881
E-mail:[email protected]
Page 5 of 5