规格书编号 SPEC NO : 产品 规 格书 SPECIFICATION CUSTOMER 客 户: PRODUCT 产 品: SAW FILTER MODEL NO 型 号: HDF40A W2 PREPARED 编 制: CHECKED 审 核: APPROVED 批 准: D A T E 日 期: 2004-9-26 客户确认 CUSTOMER RECEIVED: 审核 CHECKED 批准 APPROVED 日期 DATE 无锡市好达电子有限公司 Shoulder Electronics Limited www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 1 of 5 SAW FILTER HDF40A W2 更改历史记录 History Record 更改日期 Date www.shoulder.cn 规格书编号 Spec. No. 产品型号 Part No. 客户产品型号 Customer No. Tel:0755-82916880 Fax:0755-82916881 更改内容描述 Modify Content E-mail:[email protected] 备注 Remark Page 2 of 5 SAW FILTER HDF40A W2 1. SCOPE This specification shall cover the characteristics of SAW filter With F49A used for the E-amps/adc. 2. ELECTRICAL SPECIFICATION DC Voltage VDC AC Voltage Vpp Operation temperature Storage temperature RF Power Dissipation 10V 10V50Hz/60Hz -40℃ to +85℃ -45℃ to +85℃ 0dBm 2.2Electronic Characteristics Item Freq min typ max Nominal frequency fN - 40.68 - MHz 3.5 4.5 dB Insertion attenuation 40.50~40.86MHz attenuation 20.00~37.50MHz 30.0 35.0 dB 49.70~50.02MHz 30.0 47.0 dB 50.02~80.00MHz 30.0 35.0 dB Temperature coefficient -72 ppm/k 3. DIMENSION www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 3 of 5 SAW FILTER HDF40A W2 4.Typical Frequency Response 5. ENVIRONMENTAL CHARACTERISTICS 5-1 High temperature exposure Subject the device to +85℃ for 16 hours. Then release the filter into the room conditions for 24 hours prior to the measurement. It shall fulfill the specifications in 2.2. 5-2 Low temperature exposure Subject the device to -40℃ for 16 hours. Then release the device into the room conditions for 24 hours prior to the measurement. It shall fulfill the specifications in 2.2. 5-3 Temperature cycling Subject the device to a low temperature of -40℃ for 30 minutes. Following by a high temperature of +85℃ for 30 Minutes. Then release the device into the room conditions for 24 hours prior to the measurement. It shall meet the specifications in 2.2. 5-4 Resistance to solder heat Dip the device terminals no closer than 1.5mm into the solder bath at 260℃ ±10℃ for 10±1 sec. Then release the device into the room conditions for 4 hours. The device shall meet the specifications in 2.2. 5-5 Solderability Subject the device terminals into the solder bath at 245℃ ±5℃ for 5s, More than 95% www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 4 of 5 SAW FILTER HDF40A W2 area of the terminals must be covered with new solder. It shall meet the specifications in 2.2. 5-6 Mechanical shock Drop the device randomly onto the concrete floor from the height of 1m 3 times. the device shall fulfill the specifications in 2.2. 5-7 Vibration Subject the device to the vibration for 1 hour each in x,y and z axes with the amplitude of 1.5 mm at 10 to 55 Hz. The device shall fulfill the specifications in 2.2. 6. REMARK 6.1 Static voltage Static voltage between signal load & ground may cause deterioration &destruction of the component. Please avoid static voltage. 6.2 Ultrasonic cleaning Ultrasonic vibration may cause deterioration & destruction of the component. Please avoid ultrasonic cleaning 6.3 Soldering Only leads of component may be solded. Please avoid soldering another part of component. www.shoulder.cn Tel:0755-82916880 Fax:0755-82916881 E-mail:[email protected] Page 5 of 5