SPECIFICATION FOR APPROVAL Customer: Description: Micro Speaker SOBERTON Part No. : SP-1504 Date:2009-03-12 Customer Model No. : Date of Approval Authorization Signature 211 N.First Street Minneapolis, MN. 55401 Tel:612-849-6205 Fax:952-933-3120 Http://www.soberton.com E-mail: [email protected] Approved Checked Design Ryan Wang Cheng Song Qi 2009/03/12 2009/03/12 2009/03/12 MODEL NUMBER CUSTOMER PRODUCT NUMBER TYPE REVERSION DATE PAGE NUMBER 01A 09-03-10 1/6 SPEAKER SP-1504 1.SCOPE This specification covers our product of dynamic speaker unit for mobile telephone use. 2.MECHANICAL LAYOUT&DIMENSIONS: Shown in page3/5 3.GENERAL REQUIREMENTS: 3.1 OPERATING TEMPERATURE RANGE:-20°C~+55°C 3.2 STANDARD TEST CONDITIONS: Temperature: 17°C~25°C Relative Humidity: 45%~80%(RH) 3.3 JUDGEMENT CONDITIONS: Temperature: 20±2°C Relative Humidity: 60%~70%(RH) 4.SPEAKER MODE: 4.1 SOUND PRESSURE LEVEL: 97±3dB spl @0.6,0.8,1.0,1.2KHz in average Measuring condition :0.1W(Sine wave)0.032m measured with baffler shown in Fig.1. 4.2 IMPEDANCE: 8±15% Ω /1KHz/1V 4.3 MEASURING DIAGRAM: Shown in Fig.1. 4.4 TYPICAL FREQUENCY RESPONSE CURVE: Shown in Fig.2. 4.5 RATED POWER:0.5W. MAX POWER:0.8W 4.6 RESONANCE FREQUENCY(F0):1000±20% Hz/ 1V 4.7 DISTORTION: less than 10% at 1KHz,0.5W 4.8 BUZZ RATTLE: Must be normal at sine wave 2.53V 4.9 WEIGHT: 1.0g FACTUR N0 REVISION UPDATE DEPICT DATE CHECK E APPROVED MODEL NUMBER SP-1504 CUSTOMER PRODUCT NUMBER TYPE SPEAKER PAGE REVERSION DATE 01A 09-03-10 NUMBER 2/6 5.RELIABILITY TESTS: The sound pressure as specified shall neither deviate more than ±3dB form the initial value, nor any significant damage after any of following testing. 5.1 HIGH TEMPERATURE TEST: High temperature: +70±2°C Duration: 96 hours 5.2 LOW TEMPERATURE TEST: Low temperature: -40±2°C Duration: 96 hour 5.3 HEAT SHOCK TEST: High temperature: +70±2°C Low temperature: -40±2°C Changeover time: <30 seconds Duration: 1 hours Cycle: 100 5.4 HUMIDITY TEST: Temperature: + 40±2°C Relative Humidity: 90%~95% Duration: 96 hour 5.5 TEMPERATURE CYCLE TEST: Temperature: -40°C +70°C Duration: 45minutes 45minutes Temperature gradient: 1~3 /min Cycle: 25 5.6 DROP TEST: Mounted with dummy set mass: 100 g Height: 1.5 m Cycle: 6(1 each plain) Onto the concrete board 5.7 LOAD TEST: Speaker mode: white noise (EIA filter)for 96 [email protected] input power. N0 REVISION UPDATE DEPICT DATE FACTURE CHECK APPROVED MODEL NUMBER CUSTOMER PRODUCT NUMBER TYPE REVERSION DATE 01A 09-03-10 SPEAKER SP-1504 PAGE NUMBER 3/6 6.MEASURING METHOD(SPEAKER MODE) 6-1 .Test Condition STANDARD Temperature : 15 ~ 35℃ Relative humidity : 45% ~ 85%, Atmospheric pressure : 860mbar to 1060mbar. JUDGEMENT Temperature : 20±3℃ Relative humidity : 60% ~ 70%, Atmospheric pressure : 860mbar to 1060mbar 6-2 . Standard Test Fixture 1.Input Power : 0.1W(0.89V) 2.Zero Level : -dB 3.Mode : TSR 4.potentiometer Range : 50dB 5.Sweep Time : 0.5sec N0 REVISION UPDATE DEPICT DATE FACTURE CHECK APPROVED MODEL NUMBER CUSTOMER PRODUCT NUMBER TYPE SPEAKER SP-1504 REVERSION DATE PAGE NUMBER 01A 09-03-10 4/6 7.FREQUENCY RESPONSE CURVE N0 REVISION UPDATE DEPICT DATE FACTURE CHECK APPROVED MODEL NUMBER SP-1504 CUSTOMER PRODUCT NUMBER TYPE REVERSION DATE SPEAKER 01A 09-03-10 PAGE NUMBER 6/6 9.PACKING N0 REVISION UPDATE DEPICT DATE FACTURE CHECK APPROVED