19-6385; Rev 0; 7/12 EVALUATION KIT AVAILABLE MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive General Description Benefits and Features The MAX9271 compact serializer is designed to drive 50I coax or 100I shielded twisted-pair (STP) cable. The device pairs with the MAX9272 deserializer. SIdeal for Camera Applications Drives Low-Cost 50I Coax Cable and FAKRA Connectors or 100I STP Error Detection/Correction 9.6kbps to 1Mbps Control Channel in I2C-to-I2C Mode with Clock Stretch Capability Best-in-Class Supply Current: 75mA (max) Double-Rate Clock for Megapixel Cameras Serializer Pre/Deemphasis Allows 15m Cable at Full Speed 32-Pin (5mm x 5mm) TQFN Package with 0.5mm Lead Pitch The parallel input is programmable for single or double input. Double input allows higher pixel clock input frequency by registering two pixels of typical image-sensor video data before serializing. This doubles the maximum pixel clock frequency compared to single input. The device features an embedded control channel that operates at 9.6kbps to 1Mbps in UART and mixed UART/ I2C modes, and up to 400kbps in I2C mode. Using the control channel, a microcontroller (FC) is capable of programming serializer, deserializer, and camera (or any peripheral) registers at any time, independent of video timing. There is one dedicated GPIO, four optional GPIOs, and a GPO output, allowing remote power-up of a camera module, camera frame synchronization, and other uses. Error-detection and correction coding are programmable. For driving longer cables, the device has programmable pre/deemphasis. Programmable spread spectrum is available on the serial output. The serial output meets ISO 10605 and IEC 61000-4-2 ESD standards. The core supply range is 1.7V to 1.9V and the I/O supply range is 1.7V to 3.6V. The device is available in a 32-pin (5mm x 5mm) TQFN-EP package with 0.5mm lead pitch and operates over the -40NC to +105NC temperature range. Applications Automotive Camera Systems Ordering Information and Typical Application Circuit appear at end of data sheet. SHigh-Speed Data Serialization for Megapixel Cameras Up to 1.5Gbps Serial-Bit Rate with Single or Double Input: 6.25MHz to 100MHz Clock SMultiple Control-Channel Modes for System Flexibility 9.6kbps to 1Mbps Control Channel in UART-to UART or UART-to-I2C Modes S Reduces EMI and Shielding Requirements Output Programmable for 100mV to 500mV Single-Ended or 100mV to 400mV Differential Programmable Spread Spectrum on the Serial Output Reduces EMI Bypassable Input PLL for Parallel Clock Jitter Attenuation Tracks Spread Spectrum on Parallel Input S Peripheral Features for Camera Power-Up and Verification Built-In PRBS Generator for BER Testing of the Serial Link Up to Five GPIO Ports Dedicated “Up/Down” GPO for Camera Frame Sync Trigger and Other Uses Remote/Local Wake-Up from Sleep Mode S Meets Rigorous Automotive and Industrial Requirements -40NC to +105NC Operating Temperature ±10kV Contact and ±15kV IEC 61000-4-2 ESD Protection ±10kV Contact and ±30kV Air ISO 10605 ESD Protection For related parts and recommended products to use with this part, refer to www.maxim-ic.com/MAX9271.related. For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. 1 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive TABLE OF CONTENTS General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Benefits and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Package Thermal Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Typical Operating Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Detailed Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Register Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Input Bit Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Serial Link Signaling and Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Reverse Control Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Data-Rate Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Control Channel and Register Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 UART Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Interfacing Command-Byte-Only I2C Devices with UART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 UART Bypass Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 START and STOP Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Bit Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Slave Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Bus Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Format for Writing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Format for Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 I2C Communication with Remote-Side Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 I2C Address Translation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 I2C Broadcast Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 GPO/GPI Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Pre/Deemphasis Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Spread Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Manual Programming of the Spread-Spectrum Divider . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Additional Error Detection and Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Cyclic Redundancy Check (CRC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 2 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive TABLE OF CONTENTS (continued) Hamming Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 HS/VS Encoding and/or Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Serial Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Coax-Mode Splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Configuration Inputs (CONF1, CONF0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Sleep Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Power-Down Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Configuration Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Link Startup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Applications Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 PRBS Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Error Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Dual µC Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Jitter-Filtering PLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 PCLKIN Spread Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Changing the Clock Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Providing a Frame Sync (Camera Applications) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Software Programming of the Device Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Three-Level Configuration Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Configuration Blocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Compatibility with Other GMSL Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 GPIOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Local Control-Channel Enable (LCCEN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Internal Input Pulldowns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Choosing I2C/UART Pullup Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 AC-Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Selection of AC-Coupling Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Power-Supply Circuits and Bypassing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Power-Supply Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Board Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 ESD Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Typical Application Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Chip Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 3 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive LIST OF FIGURES Figure 1. Serial-Output Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 2. Output Waveforms at OUT+, OUT- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 3. Single-Ended Output Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 4. Worst-Case Pattern Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 5. Parallel Clock Input Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 6. I2C Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 7. Differential Output Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 8. Input Setup and Hold Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 9. GPI-to-GPO Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 10. Serializer Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 11. Link Startup Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 12. Power-Up Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Figure 13. Single-Input Waveform (Latch on Rising Edge of PCLKIN Selected) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 14. Single-Input Function Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 15. Double-Input Function Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 16. Double-Input Waveform (Latch on Rising Edge of PCLKIN Selected) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 17. Serial-Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Figure 18. GMSL UART Protocol for Base Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Figure 19. GMSL UART Data Format for Base Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Figure 20. SYNC Byte (0x79) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Figure 21. ACK Byte (0xC3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Figure 22. Format Conversion Between GMSL UART and I2C with Register Address (I2CMETHOD = 0) . . . . . . . . . 26 Figure 23. Format Conversion Between GMSL UART and I2C with Register Address (I2CMETHOD = 1) . . . . . . . . . 27 Figure 24. START and STOP Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 25. Bit Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 26. Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 27. Slave Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Figure 28. Format for I2C Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Figure 29. Format for Write to Multiple Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Figure 30. Format for I2C Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 31. 2:1 Coax-Mode Splitter Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Figure 32. Coax-Mode Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Figure 33. State Diagram, All Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Figure 34. Human Body Model ESD Test Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Figure 35. IEC 61000-4-2 Contact Discharge ESD Test Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Figure 36. ISO 10605 Contact Discharge ESD Test Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 4 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive LIST OF TABLES Table 1. Power-Up Default Register Map (see Table 16) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Table 2. Input Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 3. Data-Rate Selection Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 4. I2C Bit-Rate Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 5. TP/Coax Drive Current (CMLLVL = 1000) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 6. Serial Output Spread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 7. Spread Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 8. Modulation Coefficients and Maximum SDIV Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Table 9. Configuration Input Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Table 10. Startup Procedure for Video-Display Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Table 11. Startup Procedure for Image-Sensing Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Table 12. MAX9271 Feature Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Table 13. Double-Function Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Table 14. Typical Power-Supply Currents (Using Worst-Case Input Pattern) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Table 15. Suggested Connectors and Cables for GMSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Table 16. Register Table (see Table 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive ABSOLUTE MAXIMUM RATINGS * AVDD to EP...........................................................-0.5V to +1.9V DVDD to EP...........................................................-0.5V to +1.9V IOVDD to EP..........................................................-0.5V to +3.9V OUT+, OUT- to EP................................................-0.5V to +1.9V All other pins to EP............................... -0.5V to (VIOVDD + 0.5V) OUT+, OUT- short circuit to ground or supply .........Continuous Continuous Power Dissipation (TA = +70NC) TQFN (derate 34.5mW/NC above +70NC)...............2758.6mW Junction Temperature......................................................+150NC Operating Temperature Range......................... -40NC to +105NC Storage Temperature Range............................. -65NC to +150NC Lead Temperature (soldering, 10s).................................+300NC Soldering Temperature (reflow).......................................+260NC *EP connected to PCB ground. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. PACKAGE THERMAL CHARACTERISTICS (Note 1) TQFN Junction-to-Ambient Thermal Resistance (qJA)...........29°C/W Junction-to-Case Thermal Resistance (qJC)...................1.7°C/W Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a fourlayer board. For detailed information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial. DC ELECTRICAL CHARACTERISTICS (VAVDD = VDVDD = 1.7V to 1.9V, VIOVDD = 1.7V to 3.6V, RL= 100I Q1% (differential), EP connected to PCB ground (GND), TA = -40NC to +105NC, unless otherwise noted. Typical values are at VAVDD = VDVDD = VIOVDD = 1.8V, TA = +25NC.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS SINGLE-ENDED INPUTS (LCCEN, DIN_, PCLKIN, HS, VS, MS/HVEN, PWDN) High-Level Input Voltage VIH1 Low-Level Input Voltage VIL1 Input Current IIN1 0.65 x VIOVDD VIN = 0V to VIOVDD V -10 0.35 x VIOVDD V 20 FA THREE-LEVEL LOGIC INPUTS (CONF0, CONF1) High-Level Input Voltage VIH Low-Level Input Voltage VIL Midlevel Input Current IINM Input Current 0.7 x VIOVDD (Note 2) IIN V 0.3 x VIOVDD V -10 +10 FA -150 +150 FA SINGLE-ENDED OUTPUT (GPO) High-Level Output Voltage VOH1 IOUT = -2mA Low-Level Output Voltage VOL1 IOUT = 2mA Output Short-Circuit Current IOS VO = 0V VIOVDD - 0.2 V 0.2 VIOVDD = 3.0V to 3.6V 16 35 64 VIOVDD = 1.7V to 1.9V 3 12 21 V mA 6 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive DC ELECTRICAL CHARACTERISTICS (continued) (VAVDD = VDVDD = 1.7V to 1.9V, VIOVDD = 1.7V to 3.6V, RL= 100I Q1% (differential), EP connected to PCB ground (GND), TA = -40NC to +105NC, unless otherwise noted. Typical values are at VAVDD = VDVDD = VIOVDD = 1.8V, TA = +25NC.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS OPEN-DRAIN INPUTS/OUTPUTS (RX/SDA/EDC, TX/SCL/DBL, GPIO_) High-Level Input Voltage VIH2 Low-Level Input Voltage VIL2 Input Current Low-Level Output Voltage IIN2 VOL2 0.7 x VIOVDD V 0.3 x VIOVDD (Note 3) IOUT = 3mA RX/SDA, TX/SCL -110 +1 GPIO_ -80 +1 EDC, DBL, BWS -10 +20 VIOVDD = 1.7V to 1.9V 0.4 VIOVDD = 3.0V to 3.6V 0.3 V FA V DIFFERENTIAL SERIAL OUTPUTS (OUT+, OUT-) Differential Output Voltage Change in VOD Between Complementary Output States Output Offset Voltage, (VOUT+ + VOUT-)/2 = VOS Change in VOS between Complementary Output States VOD 300 350 400 610 3.3dB deemphasis setting (Figure 2) 240 425 DVOD VOS Preemphasis off 1.1 1.4 DVOS Output Short-Circuit Current IOS Magnitude of Differential Output Short-Circuit Current IOSD Output Termination Resistance (Internal) Preemphasis off (Figure 1) 3.3dB preemphasis setting (Figure 2) RO VOUT+ or VOUT- = 0V VOUT+ or VOUT- = 1.9V mV 25 mV 1.56 V 25 mV -62 25 VOD = 0V From VOUT+, VOUT- to VAVDD 500 mA 25 mA I 45 54 63 Preemphasis off, high drive (Figure 3) 375 500 625 3.3dB preemphasis setting, high drive (Figure 2) 435 765 3.3dB deemphasis setting, high drive (Figure 2) 300 535 VOUT+ or VOUT- = 0V -69 SINGLE-ENDED SERIAL OUTPUTS (OUT+, OUT-) Single-Ended Output Voltage VOUT Output Short-Circuit Current IOS Output Termination Resistance (Internal) RO VOUT+ or VOUT- = 1.9V From VOUT+, VOUT- to VAVDD 32 45 54 63 mV mA I 7 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive DC ELECTRICAL CHARACTERISTICS (continued) (VAVDD = VDVDD = 1.7V to 1.9V, VIOVDD = 1.7V to 3.6V, RL= 100I Q1% (differential), EP connected to PCB ground (GND), TA = -40NC to +105NC, unless otherwise noted. Typical values are at VAVDD = VDVDD = VIOVDD = 1.8V, TA = +25NC.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS 27 mV REVERSE CONTROL-CHANNEL RECEIVER OUTPUTS (OUT+, OUT-) High Switching Threshold VCHR Low Switching Threshold VCLR -27 mV POWER SUPPLY Worst-Case Supply Current (Figure 4) IWCS Single input, BWS = 0 fPCLKIN = 25MHz 44 65 fPCLKIN = 50MHz 46 75 Double input, BWS = 0 fPCLKIN = 50MHz 45 65 fPCLKIN = 100MHz 56 75 mA Sleep Mode Supply Current ICCS Single wake-up receiver enabled 40 100 FA Power-Down Supply Current ICCZ PWDN = EP 5 70 FA ESD PROTECTION Human Body Model, RD = 1.5kI, CS = 100pF OUT+, OUT- (Note 4) All Other Pins (Note 5) VESD VESD ±8 IEC 61000-4-2, RD = 330I, CS = 150pF Contact discharge ±10 Air discharge ±15 ISO 10605, RD = 2kI, CS = 330pF Contact discharge ±10 Air discharge ±30 Human Body Model, RD = 1.5kI, CS = 100pF ±4 kV kV AC ELECTRICAL CHARACTERISTICS (VDVDD = VAVDD = 1.7V to 1.9V, VIOVDD = 1.7V to 3.6V, RL = 100IQ1% (differential), EP connected to PCB ground (GND), TA = -40NC to +105NC, unless otherwise noted. Typical values are at VDVDD = VAVDD = VIOVDD = 1.8V, TA = +25NC) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS CLOCK INPUT (PCLKIN) Clock Frequency Clock Duty Cycle Clock Transition Time Clock Jitter fPCLKIN DC_ tR, tF_ tJ BWS = 1, DRS = 1 6.25 12.5 BWS = 0, DRS = 1 8.33 16.66 BWS = 1, DRS = 0 12.5 37.5 BWS = 0, DRS = 0 16.66 50 BWS = 1, DRS = 0, 15-bit double input 25 75 BWS = 0, DRS = 0, 11-bit double input 33.33 100 tHIGH/tT or tLOW/tT (Figure 5, Note 6) (Figure 5, Note 6) 1.5Gbps bit rate, 300kHz sinusoidal jitter 35 50 MHz 65 % 4 ns 800 ps (pk-pk) 8 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive AC ELECTRICAL CHARACTERISTICS (continued) (VDVDD = VAVDD = 1.7V to 1.9V, VIOVDD = 1.7V to 3.6V, RL = 100I Q1% (differential), EP connected to PCB ground (GND), TA = -40NC to +105NC, unless otherwise noted. Typical values are at VDVDD = VAVDD = VIOVDD = 1.8V, TA = +25NC) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS 9.6 1000 kbps I2C/UART AND GPIO PORT TIMING I2C/UART Bit Rate Output Rise Time tR 30% to 70%, CL = 10pF to 100pF, 1kI pullup to IOVDD 20 120 ns Output Fall Time tF 70% to 30%, CL = 10pF to 100pF, 1kI pullup to IOVDD. 20 120 ns Input Setup Time tSET I2C only (Figure 6, Note 6) 100 ns 0 ns Input Hold Time tHOLD I2C only (Figure 6, Note 6) SWITCHING CHARACTERISTICS (Note 6) Differential Output Rise/Fall Time tR, tF 20% to 80%, VOD R 400Mv, RL = 100I, serial-bit rate = 1.5Gbps 250 ps Total Serial Output Jitter (Differential Output) tTSOJ1 1.5Gbps PRBS signal, measured at VOD = 0V differential, preemphasis disabled (Figure 7) 0.25 UI Deterministic Serial Output Jitter (Differential Output) tDSOJ2 1.5Gbps PRBS signal, measured at VOD = 0V differential, preemphasis disabled (Figure 7) 0.15 UI Total Serial Output Jitter (Single-Ended Output) tTSOJ1 1.5Gbps PRBS signal, measured at VO/2, preemphasis disabled (Figure 3) 0.25 UI Deterministic Serial Output Jitter (Single-Ended Output) tDSOJ2 1.5Gbps PRBS signal, measured at VO/2, preemphasis disabled (Figure 3) 0.15 UI Parallel Data Input Setup Time tSET (Figure 8) 2 ns Parallel Data Input Hold Time tHOLD (Figure 8) 1 ns GPI-to-GPO Delay tGPIO Deserializer GPI to serializer GPO (Figure 9) Serializer Delay (Note 7) 350 Spread spectrum enabled 6880 Spread spectrum disabled 3040 Fs tSD (Figure 10) Bits Link Start Time tLOCK (Figure 11) 2 ms Power-Up Time tPU (Figure 12) 7 ms Note 2: To provide a midlevel, leave the input open, or, if driven, put driver in high impedance. High-impedance leakage current must be less than Q10µA. Note 3:IIN min due to voltage drop across the internal pullup resistor. Note 4: Specified pin to ground. Note 5: Specified pin to all supply/ground. Note 6: Guaranteed by design and not production tested. Note 7: Measured in serial link bit times. Bit time = 1/(30 x fPCLKIN) for BWS = 0. Bit time = 1/(40 x fPCLKIN) for BWS = 1. 9 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Typical Operating Characteristics (VAVDD = VDVDD = VIOVDD = 1.8V, DBL = low, TA = +25NC, unless otherwise noted.) 50 45 PREEMPHASIS = 0x01 TO 0x04 5 10 15 20 25 55 50 45 PREEMPHASIS = 0x01 TO 0x04 35 40 45 5 50 10 15 20 fPCLKIN = 20MHz -10 0% SPREAD -20 -40 -50 -60 -70 1% SPREAD -80 4% SPREAD 2% SPREAD -100 25 30 35 0.5% SPREAD -30 -90 PREEMPHASIS = 0x00 35 30 0 60 40 PREEMPHASIS = 0x00 35 PREEMPHASIS = 0x0B TO 0x0F OUTPUT POWER SPECTRUM (dBm) 55 PRBS ON, COAX MODE 65 SUPPLY CURRENT (mA) 60 40 40 18.5 19.0 19.5 20.0 20.5 21.0 21.5 PCLKIN FREQUENCY (MHz) PCLKIN FREQUENCY (MHz) PCLKIN FREQUENCY (MHz) OUTPUT POWER SPECTRUM vs. PCLKIN FREQUENCY (VARIOUS SPREAD) SERIAL LINK SWITCHING PATTERN WITH 6dB PREEMPHASIS (PARALLEL BIT RATE = 50MHz, 10m STP CABLE) SERIAL LINK SWITCHING PATTERN WITH 6dB PREEMPHASIS (PARALLEL BIT RATE = 50MHz, 20m COAX CABLE) 0 OUTPUT POWER SPECTRUM (dBm) 70 fPCLKIN = 50MHz -10 0% SPREAD -20 0.5% SPREAD MAX9271 toc05 MAX9271 toc06 MAX9271 toc04 SUPPLY CURRENT (mA) 65 PREEMPHASIS = 0x0B TO 0x0F OUTPUT POWER SPECTRUM vs. PCLKIN FREQUENCY (VARIOUS SPREAD) MAX9271 toc02 PRBS ON, COAX MODE MAX9271 toc01 70 SUPPLY CURRENT vs. PCLKIN FREQUENCY (BWS = 1) MAX9271 toc03 SUPPLY CURRENT vs. PCLKIN FREQUENCY (BWS = 0) -30 -40 -50 -60 -70 1% SPREAD -80 4% SPREAD -90 2% SPREAD -100 47 48 49 50 51 52 50mV/div 53 200ps/div 1.5Gbps 50mV/div 200ps/div 1.5Gbps PCLKIN FREQUENCY (MHz) 6dB PE, EQ OFF NO PE, 10.7dB EQ NO PE, EQ OFF BER CAN BE AS LOW AS 10-12 FOR CABLE LENGTHS LESS THAN 10m 0 0 5 10 15 STP CABLE LENGTH (m) 60 MAX9271 toc08 40 6dB PE, EQ OFF NO PE, 10.7dB EQ NO PE, EQ OFF 20 0 5 10 15 COAX CABLE LENGTH (m) 20 10m STP CABLE OPTIMUM PE/EQ SETTINGS 50 6dB PE, EQ OFF 40 30 NO PE, 10.7dB EQ NO PE, EQ OFF 20 10 BER CAN BE AS LOW AS 10-12 FOR CABLE LENGTHS LESS THAN 10m 0 20 MAXIMUM PCLKIN FREQUENCY vs. ADDITIONAL DIFFERENTIAL CL (BER < 10-10) PCLKIN FREQUENCY (MHz) 40 20 60 MAX9271 toc07 OPTIMUM PE/EQ SETTINGS PCLKIN FREQUENCY (MHz) PCLKIN FREQUENCY (MHz) 60 MAXIMUM PCLKIN FREQUENCY vs. COAX CABLE LENGTH (BER ≤ 10-10) BER CAN BE AS LOW AS 10-12 FOR CL < 4pF FOR OPTIMUM PE/EQ SETTINGS 0 25 MAX9271 toc09 MAXIMUM PCLKIN FREQUENCY vs. STP CABLE LENGTH (BER ≤ 10-10) 0 2 4 6 8 10 ADDITIONAL DIFFERENTIAL LOAD CAPACITANCE (pF) 10 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive RX/SDA/EDC AVDD OUT+ OUT- CONF1 CONF0 LCCEN TOP VIEW TX/SCL/DBL Pin Configuration 24 23 22 21 20 19 18 17 PCLKIN 25 16 PWDN DIN0 26 15 MS/HVEN DIN1 27 14 GPIO1/BWS 13 GPO 12 IOVDD 11 DIN15/VS 10 DIN14/HS 9 DIN13/GPIO5 DIN2 28 MAX9271 DVDD 29 DIN3 30 DIN4 31 EP* + 6 7 8 DIN12/GPIO4 DIN9 5 DIN11/GPIO3 4 AVDD 3 DIN10/GPIO2 2 DIN8 DIN6 1 DIN7 DIN5 32 TQFN (5mm x 5mm x 0.75mm) *CONNECT EP TO GROUND PLANE Pin Description PIN NAME 1–4, 26, 27, 28, 30, 31, 32 FUNCTION DIN0–DIN9 5, 22 AVDD 1.8V Analog Power Supply. Bypass AVDD to EP with 0.1FF and 0.001FF capacitors as close as possible to the device with the smaller capacitor closest to AVDD. 6–9 DIN10/ GPIO2–DIN13/ GPIO5 Parallel Data Inputs/GPIO. Defaults to parallel data input on power-up. Parallel data input has internal pulldown to EP. GPIO_ has an open-drain output with internal 60kI pullup to IOVDD. See Table 1 for programming details. 10 DIN14/HS Parallel Data Input/Horizontal Sync with Internal Pulldown to EP. Defaults to parallel data input on power-up. Horizontal sync input when VS/HS encoding is enabled (Table 2). 11 DIN15/VS Parallel Data Input/Vertical Sync with Internal Pulldown to EP. Defaults to parallel data input on power-up. Vertical sync input when VS/HS encoding is enabled (Table 2). 12 IOVDD Parallel Data Inputs with Internal Pulldown to EP I/O Supply Voltage. 1.8V to 3.3V logic I/O power supply. Bypass IOVDD to EP with 0.1FF and 0.001FF capacitors as close as possible to the device with the smallest value capacitor closest to IOVDD. 11 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Pin Description (continued) PIN NAME 13 GPO FUNCTION General-Purpose Output. GPO follows the GMSL deserializer GPI (or INT) input. GPO = low upon power-up and when PWDN = low. GPIO1/BWS GPIO/Bus Width Select Input. Function is determined by the state of LCCEN (Table 13). GPIO1 (LCCEN = high): Open-drain, general-purpose input/output with internal 60kI pullup to IOVDD. BWS (LCCEN = low): Input with internal pulldown to EP. Set BWS = low for 22-bit input latch. Set BWS = high for 30-bit input latch. 15 MS/HVEN Mode Select/HS and VS Encoding Enable with Internal Pulldown to EP. Function is determined by the state of LCCEN (Table 13). MS (LCCEN = high): Set MS = low to select base mode. Set MS = high to select the bypass mode. HVEN (LCCEN = low): Set HVEN = high to enable HS/VS encoding on DIN14/HS and DIN15/VS. Set HVEN = low to use DIN14/HS and DIN15/VS as parallel data inputs. 16 PWDN Active-Low, Power-Down Input with Internal Pulldown to EP. Set PWDN low to enter power-down mode to reduce power consumption. 17 LCCEN Local Control-Channel Enable Input with Internal Pulldown to EP. LCCEN = high enables the control-channel interface pins. LCCEN = low disables the control-channel interface pins and selects an alternate function on the indicated pins (Table 13). 18 CONF0 Configuration 0. Three-level configuration input (Table 9). 19 CONF1 Configuration 1. Three-level configuration input (Table 9). 14 20 OUT- Inverting Coax/Twisted-Pair Serial Output 21 OUT+ Noninverting Coax/Twisted-Pair Serial Output RX/SDA/EDC Receive/Serial Data/Error-Detection/Correction. Function is determined by the state of LCCEN (Table 13). RX/SDA (LCCEN = high): Input/output with internal 30kI pullup to IOVDD. In UART mode, RX/SDA is the Rx input of the serializer’s UART. In I2C mode, RX/SDA is the SDA input/output of the serializer’s I2C master/slave. .RX/SDA has an open-drain driver and requires a pullup resistor. EDC (LCCEN = low): Input with internal pulldown to EP. Set EDC = high to enable error-detection correction. Set EDC = low to disable error-detection correction. 24 TX/SCL/DBL Transmit/Serial Clock/Double Mode. Function is determined by the state of LCCEN (Table 13). TX/SCL (LCCEN = high): Input/output with internal 30kI pullup to IOVDD. In UART mode, TX/SCL is the Tx output of the serializer’s UART. In the I2C mode, TX/SCL is the SCL input/output of the serializer’s I2C master/slave. .TX/SCL has an open-drain driver and requires a pullup resistor. DBL (LCCEN = low): Input with internal pulldown to EP. Set DBL = high to use doubleinput mode. Set DBL = low to use single-input mode. 25 PCLKIN 29 DVDD — EP 23 Parallel Clock Input with Internal Pulldown to EP. Latches parallel data inputs and provides the PLL reference clock. 1.8V Digital Power Supply. Bypass DVDD to EP with 0.1FF and 0.001FF capacitors as close as possible to the device with the smaller value capacitor closest to DVDD. Exposed Pad. EP is internally connected to device ground. MUST connect EP to the PCB ground plane through an array of vias for proper thermal and electrical performance. 12 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Functional Diagram PCLKIN SSPLL FILTER PLL MAX9271 CLKDIV DIN0–DIN9 OUT+ DIN10/GPIO2 PARALLEL TO SERIAL DIN11/GPIO3 DIN12/GPIO4 DIN13/GPIO5 SINGLE-/ DOUBLEINPUT LATCH GPO CML TX SCRAMBLE/ CRC/ HAMMING/ 8b/10b ENCODE FIFO GPIO1/BWS FCC OUT- RX REVERSE CONTROL CHANNEL GPIO DIN14/HS DIN15/VS UART/I2C TX/SCL/ RX/SDA/ DBL EDC 13 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive RL/2 OUT+ VOD VOS OUT- RL/2 GND ((OUT+) + (OUT-))/2 OUTVOS(+) VOS(-) VOS(-) OUT+ DVOS = |VOS(+) - VOS(-)| VOD(+) VOD = 0V VOD(-) VOD(-) DVOD = |VOD(+) - VOD(-)| (OUT+) - (OUT-) Figure 1. Serial-Output Parameters OUT+ VOD(P) VOS VOD(D) OUT+ OR OUT- VO/2 VO VO/2 VO OUT- Figure 3. Single-Ended Output Template SERIAL-BIT TIME PCLKIN Figure 2. Output Waveforms at OUT+, OUT- DIN_ NOTE: PCLKIN PROGRAMMED FOR RISING LATCH EDGE. Figure 4. Worst-Case Pattern Input 14 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive tT VIH MIN tHIGH PCLKIN VIL MAX tR tF tLOW Figure 5. Parallel Clock Input Requirements START CONDITION (S) PROTOCOL BIT 7 MSB (A7) tSU;STA tLOW BIT 6 (A6) tHIGH BIT 0 (R/W) ACKNOWLEDGE (A) STOP CONDITION (P) 1/fSCL SCL tSP tBUF tr tf SDA tHD;STA tSU;DAT tHD;DAT tVD;DAT tVD;ACK tSU;STO Figure 6. I2C Timing Parameters 800mVP-P tTSOJ1 2 tTSOJ1 2 Figure 7. Differential Output Template 15 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive VIH MIN PCLKIN VIL MAX tSET tHOLD VIH MIN VIH MIN VIL MAX VIL MAX DIN_ NOTE: PCLKIN PROGRAMMED FOR RISING LATCHING EDGE. Figure 8. Input Setup and Hold Times VIH_MIN DESERIALIZER GPI VIL_MAX tGPIO SERIALIZER GPO tGPIO VOH_MIN VOL_MAX Figure 9. GPI-to-GPO Delay 16 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive EXPANDED TIME SCALE DIN_ N N+1 N+3 N+2 N+4 PCLKIN N-1 N OUT+/tSD FIRST BIT LAST BIT Figure 10. Serializer Delay PCLKIN tLOCK 350Fs SERIAL LINK INACTIVE REVERSE CONTROL CHANNEL DISABLED SERIAL LINK ACTIVE CHANNEL DISABLED REVERSE CONTROL CHANNEL AVAILABLE PWDN MUST BE HIGH Figure 11. Link Startup Time 17 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive PCLKIN PWDN VIH1 tPU POWERED DOWN POWERED UP, SERIAL LINK INACTIVE POWERED UP, SERIAL LINK ACTIVE 350µs REVERSE CONTROL CHANNEL DISABLED REVERSE CONTROL CHANNEL ENABLED REVERSE CONTROL CHANNEL DISABLED REVERSE CONTROL CHANNEL ENABLED Figure 12. Power-Up Delay Detailed Description The MAX9271 serializer, when paired with the MAX9272 deserializer, provides the full set of operating features, but offers basic functionality when paired with any GMSL deserializer. The serializer has a maximum serial-bit rate of 1.5Gbps for 15m or more of cable and operates up to a maximum input clock of 50MHz in 16-bit, single-input mode, or 75MHz/100MHz in 15-bit/11-bit, double-input mode, respectively. Pre/deemphasis, along with the GMSL deserializer channel equalizer, extends the link length and enhances link reliability. The control channel enables a FC to program serializer and deserializer registers and program registers on peripherals. The FC can be located at either end of the link or at both ends. Two modes of control-channel operation are available with associated protocols and data formats. Base mode uses either I2C or GMSL UART protocol, while bypass mode uses a user-defined UART protocol. Spread spectrum is available to reduce EMI on the serial output. The serial output complies with ISO 10605 and IEC 61000-4-2 ESD protection standards. Register Mapping Registers set the operating conditions of the serializer and are programmed using the control channel in base mode. The serializer holds its device address and the device address of the deserializer it is driving. Similarly, the driven deserializer holds its device address and the address of the serializer by which it is driven. Whenever a device address is changed, the new address should be written to both devices. The default device address of the MAX9271 serializer (or any GMSL serializer) is 0x80 and the default device address of any GMSL deserializer is 0x90 (Table 1). Registers 0x00 and 0x01 in both devices hold the device addresses. Input Bit Map The parallel input functioning and width depends on settings of the double-/single-input mode (DBL), HS/VS encoding (HVEN), error correction (EDC), and bus width (BWS) pins. DINA is the input latched by the pixel clock in single-input mode, or the inputs latched on the first pixel clock in double-input mode. DINB are the inputs latched on the second pixel clock in double-input mode. Table 2 lists the bit map for the control pin settings. 18 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 1. Power-Up Default Register Map (see Table 16) REGISTER ADDRESS (hex) POWER-UP DEFAULT (hex) 0x00 0x80 SERID = 1000000, serializer device address CFGBLOCK = 0, registers 0x00 to 0x1F are read/write 0x01 0x90 DESID = 1001000, deserializer device address RESERVED = 0 0x02 0x1F SS = 000 no spread spectrum RESERVED = 1 PRNG = 11, automatically detect the pixel clock range SRNG = 11, automatically detect serial-data rate 0x03 0x00 AUTOFM = 00, calibrate spread-modulation rate only once after locking SDIV = 000000, autocalibrate sawtooth divider 0x87 SEREN = 1, serial link enabled CLINKEN = 0, configuration link disabled PRBSEN = 0, PRBS test disabled SLEEP = 0, sleep mode disabled (see the Link Startup Procedure section) INTTYPE = 01, local control channel uses UART REVCCEN = 1, reverse control channel active (receiving) FWDCCEN = 1, forward control channel active (sending) 0x05 0x00 I2CMETHOD = 0, I2C packets include register address ENJITFILT = 0, jitter filter disabled PRBSLEN = 00, continuous PRBS length RESERVED = 00 ENWAKEN = 0, OUT- wake-up receiver disabled ENWAKEP = 1, OUT+ wake-up receiver enabled 0x06 0x80, 0xA0 CMLLVL = 1000 or 1010, output level determined by the state of CONF1 and CONF0 at power-up PREEMP = 0000, preemphasis disabled 0x07 0xXX DBL = 0 or 1, single-/double-input mode setting determined by the state of LCCEN and TX/SCL/DBL at startup DRS = 0, high data-rate mode BWS = 0 or 1, bit width setting determined by the state of LCCEN and GPIO1/BWS at startup ES = 0 or 1, edge-select input setting determined by the state of LCCEN and TX/SCL/ES at startup RESERVED = 0 HVEN = 0 or 1, HS/VS tracking encoding setting determined by the state of LCCEN and MS/HVEN at startup EDC = 00 or 10, error-detection/correction setting determined by the state of LCCEN and RX/SDA/EDC at startup 0x08 0x00 INVVS = 0, serializer does not invert VSYNC INVHS = 0, serializer does not invert HSYNC RESERVED = 000000 0x04 POWER-UP DEFAULT SETTINGS (MSB FIRST) 19 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 1. Power-Up Default Register Map (see Table 16) (continued) REGISTER ADDRESS (hex) POWER-UP DEFAULT (hex) 0x09 0x00 I2CSRCA = 0000000, I2C address translator source A is 0x00 RESERVED = 0 0x0A 0x00 I2CDSTA = 0000000, I2C address translator destination A is 0x00 RESERVED = 0 0x0B 0x00 I2CSRCB = 0000000, I2C address translator source B is 0x00 RESERVED = 0 0x0C 0x00 I2CDSTB = 0000000, I2C address translator destination B is 0x00 RESERVED = 0 0xB6 I2CLOCACK = 1, acknowledge generated when forward channel is not available I2CSLVSH = 01, 469ns/234ns I2C setup/hold time I2CMSTBT = 101, 339kbps (typ) I2C-to-I2C master bit-rate setting I2CSLVTO = 10, 1024Fs (typ) I2C-to-I2C slave remote timeout 0x42 DIS_REV_P = 0, OUT+ reverse channel receiver enabled DIS_REV_N = 1, OUT- reverse channel receiver disabled GPIO5EN = 0, GPIO5 disabled GPIO4EN = 0, GPIO4 disabled GPIO3EN = 0, GPIO3 disabled GPIO2EN = 0, GPIO2 disabled GPIO1EN = 1, GPIO1 enabled RESERVED = 0 0xFE RESERVED = 11 GPIO5OUT = 1, GPIO5 set GPIO4OUT = 1, GPIO4 set GPIO3OUT = 1, GPIO3 set GPIO2OUT = 1, GPIO2 set GPIO1OUT = 1, GPIO1 set SETGPO = 0, GPO set low 0x3E RESERVED = 00 GPIO5IN = 1, GPIO5 is input GPIO4IN = 1, GPIO4 is input GPIO3IN = 1, GPIO3 is input GPIO2IN = 1, GPIO2 is input GPIO1IN = 1, GPIO1 is input GPO_L = 0, GPO is set low 0x00 ERRGRATE = 00, generate an error every 2560 bits ERRGTYPE = 0, generate single-bit errors ERRGCNT = 00, continuously generate errors ERRGPER = 0, disable periodic error generation ERRGEN = 0, disable error generation 0x0D 0x0E 0x0F 0x10 0x11 POWER-UP DEFAULT SETTINGS (MSB FIRST) high high high high high high high high high high 20 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 1. Power-Up Default Register Map (see Table 16) (continued) REGISTER ADDRESS (hex) POWER-UP DEFAULT (hex) POWER-UP DEFAULT SETTINGS (MSB FIRST) 0x12 0x40 RESERVED = 01000000 0x13 0x22 RESERVED = 00100010 0x14 0xXX RESERVED = XXXXXXXX 0x15 0x00 CXTP = 0, CXTP is low I2CSEL = 0, input is low LCCEN = 0, local control channel disabled RESERVED = 000 OUTPUTEN = 0, output disabled PCLKDET = 0, no valid PCLKIN detected 0x16 0xXX (read only) RESERVED = XXXXXXXX 0x17 0xXX (read only) RESERVED = XXXXXXXX 0x1E 0x09 (read only) ID = 00001001, device ID is 0x09 0x1F 0x0X (read only) RESERVED = 000 CAPS = 0, serializer is not HDCP capable REVISION = XXXX, revision number X = Don’t care. Table 2. Input Map EDC BWS DBL HVEN DINA DINB* SERIAL LINK WORD BITS 0 0 0 0 0 0 0 0:15 — 0:15 1 0:13, HS, VS — 0 0 0:13 1 0 0:10 0:10 0 0:21 0 1 1 0:10, HS, VS 0:10, HS, VS 0:21 0 1 0 0 0:15 — 0:15 0 1 0 1 0:13, HS, VS — 0:13 0 1 1 0 0:14 0:14 0:29 0 1 1 1 0:13, HS, VS 0:13, HS, VS 0:13, 15:28 1 0 0 0 0:15 — 0:15 1 0 0 1 0:13, HS, VS — 0:13 1 0 1 0 0:7 0:7 0:15 1 0 1 1 0:7, HS, VS 0:7, HS, VS 0:13 1 1 0 0 0:15 — 0:15 1 1 0 1 0:13, HS, VS — 0:13 1 1 1 0 0:11 0:11 0:23 1 1 1 1 0:11, HS, VS 0:11, HS, VS 0:23 *In double-input mode (DBL = 1), DINA is latched on the first cycle of PCLKIN and DINB is latched on the second cycle of PCLKIN. 21 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive The parallel input has two input modes: single- and double-rate input. In single-input mode, LATCH A stores data from DIN_ every PCLKIN cycle (Figure 13). Parallel data from LATCH A is then sent to the scrambler for serialization (Figure 14). The device accepts pixel clocks from 6.25MHz to 50MHz. In double-input mode, LATCH B stores two input words (Figure 15). Data from LATCH B is sent to the scrambler as a combined word. The MAX9272 deserializer outputs the combined word (single-output mode) or two half-sized words (double-output mode). The serializer/deserializer use pixel clock rates from 33.3MHz to 100MHz for 11-bit, double-input mode and 25MHz to 75MHz for 15-bit, double-input mode. See Figure 16 for timing details. PCLKIN DIN0–DIN15 LATCH A FIRST WORD SECOND WORD FIRST WORD THIRD WORD SECOND WORD FOURTH WORD THIRD WORD FOURTH WORD Figure 13. Single-Input Waveform (Latch on Rising Edge of PCLKIN Selected) MAX9271 DIN0–DIN14 OR DIN0–DIN10 DIN0–DIN15 INPUT LATCH A INPUT LATCH B INPUT LATCH A MAX9271 ÷2 PCLKIN Figure 14. Single-Input Function Block PCLKIN Figure 15. Double-Input Function Block 22 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive PCLKIN ÷2 DIN0–DIN14 OR DIN0–DIN10 LATCH A FIRST WORD SECOND WORD THIRD WORD FOURTH WORD FIRST WORD LATCH B THIRD WORD FIRST AND SECOND WORD THIRD AND FOURTH WORD Figure 16. Double-Input Waveform (Latch on Rising Edge of PCLKIN Selected) Serial Link Signaling and Data Format The serializer uses differential CML signaling to drive twisted-pair cable and single-ended CML to drive coax cable. The output amplitude is programmable. Input data is scrambled and then 8b/10b coded. The deserializer recovers the embedded serial clock, then samples, decodes, and descrambles the data. In 24-bit or 32-bit mode, 22 or 30 bits contain the video data and/or error-correction bits, if used. The 23rd or 31st bit carries the forward control-channel data. The last bit is the parity bit of the previous 23 or 31 bits. (Figure 17). Reverse Control Channel The serializer uses the reverse control channel to receive I2C/UART and GPO signals from the deserializer in the opposite direction of the video stream. The reverse control channel and forward video data coexist on the same serial cable, forming a bidirectional link. The reverse control channel operates independently from the forward control channel. The reverse control channel is available 2ms after power-up. The serializer temporarily disables the reverse control channel for 350Fs after starting/stopping the forward serial link. Data-Rate Selection The serializer/deserializer use DRS, DBL, and BWS to set the PCLKIN frequency range (Table 3). Set DRS = 1 for a PCLKIN frequency range of 6.25MHz to 12.5MHz (32bit, single-input mode) or 8.33MHz to 16.66MHz (24-bit, single-input mode). Set DRS = 0 for normal operation. It is not recommended to use double-input mode when DRS = 1. Control Channel and Register Programming The control channel is available for the FC to send and receive control data over the serial link simultaneously with the high-speed data. The FC controls the link from either the serializer or the deserializer side. The control channel between the FC and serializer or deserializer runs in base mode or bypass mode, according to the mode selection (MS/HVEN) input of the device connected to the FC. Base mode is a half-duplex control channel and bypass mode is a full-duplex control channel. UART Interface In base mode, the FC is the host and can access the registers of both the serializer and deserializer from either side of the link using the GMSL UART protocol. The FC can also program the peripherals on the remote side by sending the UART packets to the serializer or deserializer, with the UART packets converted to I2C by the device on the remote side of the link. The FC communicates with a UART peripheral in base mode (through INTTYPE register settings), using the half-duplex default GMSL UART protocol of the serializer/deserializer. The device addresses of the serializer/deserializer in base mode are programmable. The default value is 0x80 for the serializer and 0x90 for the deserializer. When the peripheral interface is I2C, the serializer/ deserializer convert UART packets to I2C that have device addresses different from those of the serializer or deserializer. The converted I2C bit rate is the same as the original UART bit rate. 23 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive 24 BITS D0 D1 VIDEO AND ERRORCORRECTION DATA 32 BITS D21 FCC PCB D0 D1 D29 FORWARD CONTROLCHANNEL BIT VIDEO AND ERRORCORRECTION DATA FCC PCB FORWARD CONTROLCHANNEL BIT PACKET PARITY CHECK BIT PACKET PARITY CHECK BIT NOTE: SERIAL DATA SHOWN BEFORE SCRAMBLING AND 8b/10b ENCODING Figure 17. Serial-Data Format Table 3. Data-Rate Selection Table DRS SETTING DBL SETTING BWS SETTING PCLKIN RANGE (MHz) 0 0 0 (single input) 0 (24-bit mode) 16.66 to 50 0 1 (32-bit mode) 12.5 to 35 0 1 (double input) 0 33.3 to 100 0 1 1 25 to 75 1 0 0 8.33 to 16.66 1 0 1 6.25 to 12.5 1 1 0 Do not use 1 1 1 Do not use The deserializer uses differential line coding to send signals over the reverse channel to the serializer. The bit rate of the control channel is 9.6kbps to 1Mbps in both directions. The serializer/deserializer automatically detect the control-channel bit rate in base mode. Packet bit-rate changes can be made in steps of up to 3.5 times higher or lower than the previous bit rate. See the Changing the Clock Frequency section for more information on changing the control-channel bit rate. Figure 18 shows the UART protocol for writing and reading in base mode between the FC and the serializer/ deserializer. Figure 19 shows the UART data format. Figure 20 and Figure 21 detail the formats of the SYNC byte (0x79) and the ACK byte (0xC3). The FC and the connected slave chip generate the SYNC byte and ACK byte, respectively. Events such as device wake-up and GPI generate transitions on the control channel that can be ignored by the FC. Data written to the serializer/deserializer registers do not take effect until after the ACK byte is sent. This allows the FC to verify that write commands are received without error, even if the result of the write command directly affects the serial link. The slave uses the SYNC byte to synchronize with the host UART’s data rate. If the GPI or MS/HVEN inputs of the deserializer toggle while there is control-channel communication, or if a line fault occurs, the control-channel communication is corrupted. In the event of a missed or delayed acknowledge (~1ms due to control-channel timeout), the FC should assume there was an error in the packet when the slave device received it, or that an error occurred during the response from the slave device. In base mode, the FC must keep the UART Tx/Rx lines high for 16 bit times before starting to send a new packet. 24 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive WRITE DATA FORMAT SYNC DEV ADDR + R/W REG ADDR NUMBER OF BYTES BYTE 1 BYTE N ACK MASTER WRITES TO SLAVE MASTER READS FROM SLAVE READ DATA FORMAT SYNC DEV ADDR + R/W REG ADDR NUMBER OF BYTES MASTER WRITES TO SLAVE ACK BYTE 1 BYTE N MASTER READS FROM SLAVE Figure 18. GMSL UART Protocol for Base Mode 1 UART FRAME START D0 D1 D2 D3 D4 D5 D6 D7 PARITY FRAME 2 FRAME 1 STOP STOP FRAME 3 START STOP START Figure 19. GMSL UART Data Format for Base Mode START D0 D1 D2 D3 D4 D5 D6 D7 1 0 0 1 1 1 1 0 Figure 20. SYNC Byte (0x79) PARITY STOP START D0 D1 D2 D3 D4 D5 D6 D7 1 1 0 0 0 0 1 1 PARITY STOP Figure 21. ACK Byte (0xC3) 25 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive As shown in Figure 22, the remote-side device converts packets going to or coming from the peripherals from UART format to I2C format and vice versa. The remote device removes the byte number count and adds or receives the ACK between the data bytes of I2C. The I2C bit rate is the same as the UART bit rate. Interfacing Command-Byte-Only I2C Devices with UART The serializer/deserializer UART-to-I2C conversion can interface with devices that do not require register addresses, such as the MAX7324 GPIO expander. In this mode, the I2C master ignores the register address byte and directly reads/writes the subsequent data bytes (Figure 23). Change the communication method of the I2C master using the I2CMETHOD bit. I2CMETHOD = 1 sets command-byte-only mode, while I2CMETHOD = 0 sets normal mode where the first byte in the data stream is the register address. UART Bypass Mode In bypass mode, the serializer/deserializer ignore UART commands from the FC and the FC communicates with the peripherals directly using its own defined UART protocol. The FC cannot access the serializer/deserializer registers in this mode. Peripherals accessed through the forward control channel using the UART interface need to handle at least one PCLKIN period Q10ns of jitter due to the asynchronous sampling of the UART signal by PCLKIN. Set MS/HVEN = high to put the control channel into bypass mode. For applications with the FC connected to the deserializer, there is a 1ms wait time between setting MS/HVEN high and the bypass control channel being active. There is no delay time when switching to bypass mode when the FC is connected to the serializer. Do not send a logic-low value longer than 100Fs to ensure proper GPO functionality. Bypass mode accepts bit rates down to 10kbps in either direction. See the GPO/ GPI Control section for GPO functionality limitations. The control-channel data pattern should not be held low longer than 100Fs if GPO control is used. UART-TO-I2C CONVERSION OF WRITE PACKET (I2CMETHOD = 0) FC SERIALIZER/DESERIALIZER 11 11 SYNC FRAME DEVICE ID + WR SERIALIZER/DESERIALIZER 11 REGISTER ADDRESS PERIPHERAL 1 S 7 DEV ID 1 1 W A UART-TO-I2C CONVERSION OF READ PACKET (I2CMETHOD = 0) SERIALIZER/DESERIALIZER FC 11 11 11 SYNC FRAME DEVICE ID + RD REGISTER ADDRESS SERIALIZER/DESERIALIZER PERIPHERAL 1 S 7 DEV ID 1 1 W A : MASTER TO SLAVE 11 NUMBER OF BYTES 8 REG ADDR 11 DATA 0 1 A 8 DATA 0 11 NUMBER OF BYTES 8 REG ADDR 11 DATA N 1 1 A S : SLAVE TO MASTER 11 ACK FRAME 7 DEV ID S: START 1 1 R A 8 DATA 0 P: STOP 1 A 11 ACK FRAME 1 A 8 DATA N 11 DATA 0 8 DATA N 1 1 A P 11 DATA N 1 1 A P A: ACKNOWLEDGE Figure 22. Format Conversion Between GMSL UART and I2C with Register Address (I2CMETHOD = 0) 26 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive UART-TO-I2C CONVERSION OF WRITE PACKET (I2CMETHOD = 1) FC 11 SYNC FRAME SERIALIZER/DESERIALIZER 11 11 DEVICE ID + WR REGISTER ADDRESS SERIALIZER/DESERIALIZER FC PERIPHERAL 1 7 S DEV ID 11 NUMBER OF BYTES 11 DATA 0 1 1 W A 8 DATA 0 UART-TO-I2C CONVERSION OF READ PACKET (I2CMETHOD = 1) SERIALIZER/DESERIALIZER 11 11 11 11 SYNC FRAME DEVICE ID + RD REGISTER ADDRESS NUMBER OF BYTES SERIALIZER/DESERIALIZER PERIPHERAL 1 S : MASTER TO SLAVE 11 DATA N : SLAVE TO MASTER 11 ACK FRAME 7 DEV ID S: START 1 1 R A 8 DATA 0 P: STOP 11 ACK FRAME 1 A 8 DATA N 11 DATA 0 1 A 8 DATA N 1 1 A P 11 DATA N 1 1 A P A: ACKNOWLEDGE Figure 23. Format Conversion Between GMSL UART and I2C with Register Address (I2CMETHOD = 1) I2C Interface In I2C-to-I2C mode the serializer’s control-channel interface sends and receives data through an I2C-compatible 2-wire interface. The interface uses a serial-data line (SDA) and a serial-clock line (SCL) to achieve bidirectional communication between master and slave(s). A FC master initiates all data transfers to and from the device and generates the SCL clock that synchronizes the data transfer. When an I2C transaction starts on the local-side device’s control-channel port, the remote-side device’s control-channel port becomes an I2C master that interfaces with remote-side I2C perhipherals. The I2C master must accept clock stretching, which is imposed by the serializer (holding SCL low). The SDA and SCL lines operate as both an input and an open-drain output. Pullup resistors are required on SDA and SCL. Each transmission consists of a START condition (Figure 6) sent by a master, followed by the device’s 7-bit slave address plus a R/W bit, a register address byte, one or more data bytes, and finally a STOP condition. START and STOP Conditions Both SCL and SDA remain high when the interface is not busy. A master signals the beginning of a transmission with a START (S) condition by transitioning SDA from high to low while SCL is high (see Figure 24). When the master has finished communicating with the slave, it issues a STOP (P) condition by transitioning SDA from low to high while SCL is high. The bus is then free for another transmission. Bit Transfer One data bit is transferred during each clock pulse (Figure 25). The data on SDA must remain stable while SCL is high. Acknowledge The acknowledge bit is a clocked 9th bit that the recipient uses to handshake receipt of each byte of data (Figure 26). Thus, each byte transferred effectively requires 9 bits. The master generates the 9th clock pulse, and the recipient pulls down SDA during the acknowledge clock pulse. The SDA line is stable low during the high period of the clock pulse. When the master is transmitting to the slave device, the slave device generates the acknowledge bit because the slave device is the recipient. When the slave device is transmitting to the master, the master generates the acknowledge bit because the master is the recipient. The device generates an acknowledge even when the forward control channel is not active (not locked). To prevent acknowledge generation when the forward control channel is not active, set the I2CLOCACK. 27 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive SDA SCL S P START CONDITION STOP CONDITION Figure 24. START and STOP Conditions SDA SCL DATA LINE STABLE; DATA VALID CHANGE OF DATA ALLOWED Figure 25. Bit Transfer START CONDITION CLOCK PULSE FOR ACKNOWLEDGE 1 SCL 2 8 9 SDA BY TRANSMITTER SDA BY RECEIVER S Figure 26. Acknowledge 28 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive followed by at least one byte of information. The first byte of information is the register address or command byte. The register address determines which register of the device is to be written by the next byte, if received. If a STOP (P) condition is detected after the register address is received, the device takes no further action beyond storing the register address (Figure 28). Any bytes received after the register address are data bytes. The first data byte goes into the register selected by the register address, and subsequent data bytes go into subsequent registers (Figure 29). If multiple data bytes are transmitted before a STOP condition, these bytes are stored in subsequent registers because the register addresses autoincrement. Slave Address The serializer/deserializer have a 7-bit-long slave address. The bit following a 7-bit slave address is the R/W bit, which is low for a write command and high for a read command. The slave address is 10000001 for read commands and 10000000 for write commands. See Figure 27. Bus Reset The device resets the bus with the I2C START condition for reads. When the R/W bit is set to 1, the serializer/ deserializer transmit data to the master, thus the master is reading from the device. Format for Writing A write to the serializer/deserializer comprises the transmission of the slave address with the R/W bit set to zero, 0 0 1 SDA 0 0 0 0 R/W MSB ACK LSB SCL Figure 27. Slave Address 0 = WRITE ADDRESS = 0x80 S 1 0 0 0 0 REGISTER ADDRESS = 0x00 0 0 0 A 0 0 0 0 0 0 REGISTER 0x00 WRITE DATA 0 0 A D7 D6 D5 D4 D3 D2 D1 D0 A P S = START BIT P = STOP BIT A = ACK D_ = DATA BIT Figure 28. Format for I2C Write 0 = WRITE ADDRESS = 0x80 S 1 0 0 0 0 REGISTER ADDRESS = 0x00 0 0 0 A 0 0 REGISTER 0x00 WRITE DATA D7 D6 D5 D4 D3 D2 0 0 0 0 0 0 A D1 D0 N S = START BIT P = STOP BIT A = ACK N = NACK D_ = DATA BIT REGISTER 0x01 WRITE DATA D1 D0 A D7 D6 D5 D4 D3 D2 P Figure 29. Format for Write to Multiple Registers 29 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive bit rate different than 400kbps, local- and remote-side I2C setup and hold times should be adjusted by setting the SLV_SH register settings on both sides. Format for Reading The serializer/deserializer are read using the internally stored register address as an address pointer, the same way the stored register address is used as an address pointer for a write. The pointer autoincrements after each data byte is read using the same rules as for a write. Thus, a read is initiated by first configuring the register address by performing a write (Figure 30). The master can now read consecutive bytes from the device, with the first data byte being read from the register address pointed by the previously written register address. Once the master sends a NACK, the device stops sending valid data. I2C Address Translation The serializer supports I2C address translation for up to two device addresses. Use address translation to assign unique device addresses to peripherals with limited I2C addresses. Source addresses (address to translate from) are stored in registers 0x09 and 0x0B. Destination addresses (address to translate to) are stored in registers 0x0A and 0x0C. I2C Broadcast Mode I2C Communication with Remote-Side Devices The serializer supports I2C communication with a peripheral on the remote side of the communication link using SCL clock stretching. While multiple masters can reside on either side of the communication link, arbitration is not provided. The connected masters need to support SCL clock stretching and provide contention detection. The remote side I2C bit-rate range must be set according to the local-side I2C bit rate. Supported remote-side bit rates can be found in Table 4. Set the I2CMSTBT (register 0x0D) to set the remote I2C bit rate. If using a The serializer supports broadcast commands to control multiple peripheral devices. Select an unused device address to use as a broadcast device address. Program the remote-side GMSL device to translate the broadcast device address (source address stored in registers 0x09, 0x0B) to the peripheral device address (destination address stored in registers 0x0A, 0x0C). Any commands sent to the broadcast address are sent to all designated peripherals, while commands sent to a peripheral’s unique device address are sent to that particular device only. 0 = WRITE ADDRESS = 0x80 S 1 0 0 0 0 REGISTER ADDRESS = 0x00 0 0 0 A 0 0 0 0 0 0 0 0 A S = START BIT P = STOP BIT A = ACK N = NACK D_ = DATA BIT 1 = READ ADDRESS = 0x81 REPEATED START S 1 0 0 0 0 REGISTER 0x00 READ DATA 0 0 1 A D7 D6 D5 D4 D3 D2 D1 D0 N P Figure 30. Format for I2C Read Table 4. I2C Bit-Rate Ranges LOCAL BIT RATE REMOTE BIT-RATE RANGE f > 50kbps Up to 1Mbps I2CMSTBT SETTING Any 20kbps > f > 50kbps Up to 400kbps Up to 110 f < 20kbps Up to 10kbps 000 30 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive GPO/GPI Control GPO on the serializer follows GPI transitions on the deserializer. This GPO/GPI function can be used to transmit signals such as frame sync in a surround-view camera system. The GPI-to-GPO delay is 0.35ms (max). Keep the time between GPI transitions to a minimum 0.35ms. This includes transitions from the other deserializer in the coax-mode splitter. Bit D4 of register 0x0E in the deserializer stores the GPI input state. GPO is low after power-up. The FC can set GPO by writing to the SET_GPO register bit. Do not send a logic-low value on the deserializer RX/ SDA input (UART mode) longer than 100Fs in either base or bypass mode to ensure proper GPO/GPI functionality. Pre/Deemphasis Driver The serial line driver employs current-mode logic (CML) signaling. The driver is differential when programmed for twisted-pair (TP). When programmed for coax, one side of the CML driver is used. The line driver has programmable pre/deemphasis that modifies the output to compensate for cable length. There are 13 preemphasis settings, as shown in Table 5. Negative preemphasis levels are deemphasis levels in which the preemphasized swing level is the same as normal swing, but the no-transition data (e.g., a 1 followed by a 1) is deemphasized. Program the preemphasis levels through register 0x06 D[3:0] of the serializer. This preemphasis function compensates the high-frequency loss of the cable and enables reliable transmission over longer link distances. Current drive for both TP and coax modes is programmable. CMLLVL bits (0x06, D[7:4]) program drive current in TP and coax modes for a single-ended voltage swing from 100mV to 500mV. Spread Spectrum To reduce the EMI generated by the transitions on the serial link, the serializer output is programmable for spread spectrum. If the deserializer driven by the serializer has programmable spread spectrum, do not enable spread for both at the same time or their interaction will cancel benefits. The deserializer tracks the serializer’s spread and passes the spread to the deserializer output. The programmable spread-spectrum amplitudes are Q0.5%, Q1%, Q1.5%, Q2%, Q3%, and Q4% (Table 6). Some spread-spectrum amplitudes can only be used at lower PCLKIN frequencies (Table 7). There is no PCLKIN frequency limit for the Q0.5% spread rate. When the spread spectrum is turned on or off, the serial link stops for several microseconds and then restarts in order for the deserializer to lose and relock to the new serial-data stream. The serializer includes a sawtooth divider to control the spread-modulation rate. Autodetection of the PCLKIN Table 5. TP/Coax Drive Current (CMLLVL = 1000) SINGLE-ENDED VOLTAGE SWING PREEMPHASIS LEVEL (dB)* PREEMP SETTING (0x06, D[3:0]) ICML (mA) IPRE (mA) MAX (mV) MIN (mV) -6.0 0100 12 4 400 200 -4.1 0011 13 3 400 250 -2.5 0010 14 2 400 300 -1.2 0001 15 1 400 350 0 (power-on default) 0000 16 0 400 400 1.1 1000 16 1 425 375 2.2 1001 16 2 450 350 3.3 1010 16 3 475 325 4.4 1011 16 4 500 300 6.0 1100 15 5 500 250 8.0 1101 14 6 500 200 10.5 1110 13 7 500 150 14.0 1111 12 8 500 100 *Negative preemphasis levels denote deemphasis. 31 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 6. Serial Output Spread SS SPREAD (%) 000 No spread spectrum. Power-up default. 001 ±0.5% spread spectrum. 010 ±1.5% spread spectrum. 011 ±2% spread spectrum. 100 No spread spectrum. 101 ±1% spread spectrum. 110 ±3% spread spectrum. 111 ±4% spread spectrum. Table 7. Spread Limitations BWS = 0 MODE, PCLKIN FREQUENCY (MHz) BWS = 1 MODE, PCLKIN FREQUENCY (MHz) < 33.3 (DBL = 0) < 25 (DBL = 0) < 66.6 (DBL = 1) < 50 (DBL = 1) 33.3 to 50 (DBL = 0) 25 to 37.5 (DBL = 0) 66.6 to 100 (DBL = 1) 50 to 75 (DBL = 1) operation range guarantees a spread-spectrum modulation frequency within 20kHz to 40kHz. Additionally, manual configuration of the sawtooth divider (SDIV: 0x03, D[5:0]) allows the user to set a modulation frequency according to the PCLKIN frequency. When ranges are manually selected, program the SDIV value for a fixed modulation frequency around 20kHz. Manual Programming of the Spread-Spectrum Divider The modulation rate relates to the PCLKIN frequency as follows: f fM= (1 + DRS) PCLKIN MOD x SDIV where: fM = Modulation frequency DRS = DRS value (0 or 1) fPCLKIN = PCLKIN frequency MOD = Modulation coefficient given in Table 8 SDIV = 6-bit SDIV setting, manually programmed by the FC To program the SDIV setting, first look up the modulation coefficient according to the desired bus-width and SERIAL LINK BIT RATE (Mbps) AVAILABLE SPREAD RATES < 1000 All rates available R 1000 1.5%, 1.0%, 0.5% spread-spectrum settings. Solve the above equation for SDIV using the desired pixel clock and modulation frequencies. If the calculated SDIV value is larger than the maximum allowed SDIV value in Table 8, set SDIV to the maximum value. Additional Error Detection and Correction In default mode (additional error detection and correction disabled), data encoding/decoding is the same as in previous GMSL serializers/deserializers (parity only). At the serializer, the parallel input word is scrambled and a parity bit is added. The scrambled word is divided into 3 or 4 bytes (depending on the BWS setting), 8b/10b encoded, and then transmitted serially. At the deserializer, the same operations are performed in reverse order. The parity bit is used by the deserializer to find the word boundary and for error detection. Errors are counted in an error counter register and an error pin indicates errors. The serializer can use one of two additional errordetection/correction methods (selectable by register setting): 1) 6-bit cyclic redundancy check 2) 6-bit hamming code with 16-word interleaving 32 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 8. Modulation Coefficients and Maximum SDIV Settings BWS 1 0 SPREADSPECTRUM SETTING (%) MODULATION COEFFICIENT (dec) SDIV UPPER LIMIT (dec) 1 104 40 0.5 104 63 3 152 27 1.5 152 54 4 204 15 2 204 30 1 80 52 0.5 80 63 3 112 37 1.5 112 63 4 152 21 2 152 42 Cyclic Redundancy Check (CRC) When CRC is enabled, the serializer adds 6 bits of CRC to the input data. This reduces the available bits in the input data word by 6, compared to the non-CRC case (see Table 2 for details). For example, 16 bits are available for input data instead of 22 bits when BWS = 0, and 24 bits instead of 30 bits when BWS = 1. The CRC generator polynomial is x6 + x + 1 (as used in the ITU-T G704 telecommunication standard). The parity bit is still added when CRC is enabled, because it is used for word-boundary detection. When CRC is enabled, each data word is scrambled and then the 6-bit CRC and 1-bit parity are added before the 8b/10b encoding. At the deserializer, the CRC code is recalculated. If the recalculated CRC code does not match the received CRC code, an error is flagged. This CRC error is reported to the error counter. Hamming Code Hamming code is a simple and effective error-correction code to detect and/or correct errors. The MAX9271 serializer (when used with the MAX9272 GMSL deserializer) uses a single-error correction, double-error detection per pixel hamming-code scheme. The serializer uses data interleaving for burst error tolerance. Burst errors up to 11 consecutive bits on the serial link are corrected, and burst errors up to 31 consecutive bits are detected. Hamming code adds overhead similar to CRC. See Table 2 for details regarding the available input word size. HS/VS Encoding and/or Tracking HS/VS encoding by a GMSL serializer allows horizontal and vertical synchronization signals to be transmitted while conserving pixel data bandwidth. With HS/VS encoding enabled, 10-bit pixel data with a clock up to 100MHz can be transmitted using one video pixel of data per HS/VS transition, versus 8-bit data with a clock up to 100MHz without HS/VS encoding. The deserializer performs HS/VS decoding, tracks the period of the HS/ VS signals, and uses voting to filter HS/VS bit errors. When using HS/VS encoding, use a minimum HS/VS lowpulse duration of two PCLKIN cycles when DBL = 0 on the MAX9271/MAX9273. When DBL = 1, use a minimum low-pulse duration of five PCLKIN cycles and a minimum high-pulse duration of two PCLKIN cycles. When using hamming code with HS/VS encoding, do not send more than two transitions every 16 PCLKIN cycles. When the serializer uses double-input mode (DBL = 1) the active duration, plus the blanking duration of HS or VS signals, should be an even number of PCLKIN cycles. If HS/VS tracking is used without HS/VS encoding, use DIN0 for HSYNC and DIN1 for VSYNC. In this case, if DBL values on the serializer and the deserializer are different, set the deserializer’s UNEQDBL register bit to 1. If the serializer and deserializer have unequal DBL settings and HVEN = 0, then HS/VS inversion should only be used on the side that has DBL = 1. HS/VS encoding sends packets when HSYNC or VSYNC is low, use H/V inversion register bits if input HSYNC and VSYNC signals use an active-low convention to send data packets during the inactive pixel clock periods. Serial Output The driver output is programmable for two types of cable: 100I twisted pair and 50I coax (contact the factory for serializers with 75I cable drive). 33 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Coax-Mode Splitter In coax mode, OUT+ and OUT- are active. This enables use as a 1:2 splitter (Figure 31). In coax mode, connect OUT+ to IN+ of the deserializer. Connect OUT- to IN- of the second deserializer. Control-channel data is broadcast from the serializer to both deserializers and their attached peripherals. Assign a unique device address to send control data to one deserializer. Leave all unused IN_ pins unconnected, or connect them to ground through 50I and a capacitor for increased power-supply rejection. If OUT- is not used, connect OUT- to AVDD through a 50I resistor (Figure 32). When there are FCs at the serializer, and at each deserializer, only one FC can communicate at a time. Disable one splitter controlchannel link to prevent contention. Use the DIS_REV_P or DIS_REV_N register bits to disable a control-channel link. GMSL DESERIALIZER MAX9271 OUT+ IN+ OUT- IN- Configuration Inputs (CONF1, CONF0) CONF1 and CONF0 determine the power-up values of the serial output type, the input data latch, and the control-channel interface type (Table 9). These functions can be changed after power-up by writing to the appropriate register bits. Sleep Mode The serializer includes a sleep mode to reduce power consumption. The device enters or exits sleep mode by a command from a local FC or a remote FC using the control channel. Set the SLEEP bit to 1 to initiate sleep mode. The serializer sleeps immediately after setting its SLEEP = 1. The OUT+ and OUT- serial outputs each have a wake-up receiver to accept wake-up commands from the attached deserializers. On power-up, the OUT+ GMSL DESERIALIZER MAX9271 OUT+ OUT- IN+ IN- AVDD GMSL DESERIALIZER 50I IN+ IN- Figure 31. 2:1 Coax-Mode Splitter Connection Diagram Figure 32. Coax-Mode Connection Diagram Table 9. Configuration Input Map CONF1 CONF0 CXTP (OUT+/OUT- OUTPUT TYPE) ES (PCLKIN LATCH EDGE) I2CSEL (CONTROL-CHANNEL TYPE) Low Low 1 (coax) 1 (falling) 1 (I2C-to-I2C) Low Mid 1 (coax) 1 (falling) 0 (UART-to-I2C/UART) Low High 1 (coax) 0 (rising) 1 (I2C-to-I2C) Mid Low 1 (coax) 0 (rising) 0 (UART-to-I2C/UART) Mid Mid 0 (STP) 1 (falling) 1 (I2C-to-I2C) Mid High 0 (STP) 1 (falling) 0 (UART-to-I2C/UART) High Low 0 (STP) 0 (rising) 1 (I2C-to-I2C) High Mid 0 (STP) 0 (rising) 0 (UART-to-I2C/UART) High High Do not use Do not use Do not use 34 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive wake-up receiver is enabled and the OUT- wake-up receiver is disabled. Disable the wake-up receivers (through ENWAKEP or ENWAKEN) if the devices are disconnected or wake-up is not used in order to reduce sleep mode current. If both wake-up receivers are disabled, the device can only be woken up from the local control channel. To wake up the device, send an arbitrary control-channel command to the serializer. Wait 5ms for the chip to power up and then write 0 to the SLEEP register bit to make the wake-up permanent. Configuration Link The control channel can operate in a low-speed mode called configuration link in the absence of a clock input. This allows a microprocessor to program configuration registers before starting the video link. An internal oscillator provides the clock for the configuration link. Set CLINKEN = 1 on the serializer to enable the configuration link. The configuration link is active until the video link is enabled. The video link overrides the configuration link and attempts to lock when SEREN = 1. Power-Down Mode The serializer has a power-down mode that further reduces power consumption compared to sleep mode. Set PWDN low to enter power-down mode. In powerdown mode, the serial outputs are in high impedance. Entering power-down resets the device’s registers. Upon exiting power-down, the state of the GPIO1/BWS, MS/HVEN, LCCEN, CONF0, CONF1, RX/SDA/EDC, and TX/SCL/DBL pins are latched. Link Startup Procedure Table 10 lists the startup procedure for video-display applications. Table 11 lists the startup procedure for image-sensing applications. The control channel is available after the video link or the configuration link is established. If the deserializer powers up after the serializer, the control channel becomes unavailable until 2ms after power-up. Table 10. Startup Procedure for Video-Display Applications NO. µC SERIALIZER DESERIALIZER — FC connected to serializer. Sets all configuration inputs. If any configuration inputs are available on one end of the link but not on the other, always connects that configuration input low. Sets all configuration inputs. If any configuration inputs are available on one end of the link but not on the other, always connects that configuration input low. 1 Powers up. Powers up and loads default settings. Powers up and loads default settings. 2 Enables configuration link by setting CLINKEN = 1 (if not enabled automatically) and gets an acknowledge. Waits for link to be established (~3ms). Establishes configuration link. Locks to configuration link signal. 3 Writes one link configuration bit (DRS, BWS, or EDC) in the deserializer and gets an acknowledge. — Configuration changed from default settings (loss-of-lock occurs if BWS or EDC changes). 4 Writes corresponding serializer link configuration bit and gets an acknowledge. Configuration changed from default settings. Relocks to configuration link signal. 5 Waits for link to be established (~3ms) and then repeats steps 3 through 4 until all serial link bits are configured. — — 6 Writes remaining configuration bits in the serializer/deserializer and gets an acknowledge. Configuration changed from default settings. Configuration changed from default settings. 7 Enables video link by setting SEREN = 1 and gets an acknowledge. Waits for link to be established (~3ms). Begins serializing data. Locks to serial link signal and begins deserializing data. 35 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 11. Startup Procedure for Image-Sensing Applications NO. µC SERIALIZER DESERIALIZER — FC connected to deserializer. Sets all configuration inputs. If any configuration inputs are available on one end of the link but not on the other, always connects that configuration input low. Sets all configuration inputs. If any configuration inputs are available on one end of the link but not on the other, always connects that configuration input low. 1 Powers up. Powers up and loads default settings. Establishes serial link. Powers up and loads default settings. Locks to serial link signal. 3 Writes deserializer configuration bits and gets an acknowledge. — Configuration changed from default settings (loss-of-lock occurs if BWS or EDC changes). 4 Writes serializer configuration bits. Does not get an acknowledge (or gets a dummy acknowledge) if lossof-lock occurred. Configuration changed from default settings. Relocks to serial link signal. 5 Enables video link by setting SEREN = 1 (if not enabled automatically). Cannot get an acknowledge (or gets a dummy acknowledge) if loss-oflock occurred. Waits for link to be established (~3ms). Begins serializing data. Locks to serial link signal and begins deserializing data. CLINKEN = 0 OR SEREN = 1 SLEEP CLINKEN = 0 OR SEREN = 1 SLEEP = 1 FOR > 8ms WAKE-UP WAKE-UP SIGNAL SLEEP = 0, SEREN = 1 SLEEP = 1 SLEEP = 0, SEREN = 0 POWER-ON IDLE SEREN = 1, PCLKIN RUNNING CLINKEN = 1 PWDN = LOW OR POWER-OFF POWER-DOWN OR POWER-OFF PWDN = HIGH, POWER-ON VIDEO LINK LOCKING CONFIG LINK UNLOCKED CONFIG LINK LOCKED CONFIG LINK OPERATING PROGRAM REGISTERS SEREN = 0 OR NO PCLKIN SEREN = 0 OR NO PCLKIN ALL STATES CONFIG LINK STARTED VIDEO LINK LOCKED PRBSEN = 0 VIDEO LINK OPERATING PRBSEN = 1 VIDEO LINK PRBS TEST VIDEO LINK UNLOCKED Figure 33. State Diagram, All Applications 36 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Applications Information PRBS Test The serializer includes a PRBS pattern generator that works with bit-error verification in the deserializer. To run the PRBS test, set PRBSEN = 1 (0x04, D5) in the deserializer and then in the serializer. To exit the PRBS test, set PRBSEN = 0 (0x04, D5) in the serializer. Error Generator The serializer contains an error generator that enables repeatable testing of the error-detection/correction features of the GMSL link. Register 0x11 stores the configuration bits for the error generator. A FC sets the errorgeneration rate, type of errors, and the total number of errors. The error generator is off by default. Dual µC Control Usually systems have one FC to run the control channel, located on the serializer side for video-display applications or on the deserializer side for image-sensing applications. However, a FC can reside on each side simultaneously and trade off running the control channel. In this case, each FC can communicate with the serializer and deserializer and any peripheral devices. Contention occurs if both FC s attempt to use the control channel at the same time. It is up to the user to prevent this contention by implementing a higher-level protocol. In addition, the control channel does not provide arbitration between I2C masters on both sides of the link. An acknowledge frame is not generated when communication fails due to contention. If communication across the serial link is not required, the FC s can disable the forward and reverse control channel using the FWDCCEN and REVCCEN bits (0x04, D[1:0]) in the serializer/deserializer. Communication across the serial link is stopped and contention between FC s cannot occur. As an example of dual FC use in an image-sensing application, the serializer can be in sleep mode, waiting for wake-up by the FC on the deserializer side. After wakeup, the serializer-side FC assumes master control of the serializer’s registers. Jitter-Filtering PLL In some applications, the clock input (PCLKIN) includes noise, which reduces link reliability. The clock input has a programmable narrowband jitter-filter PLL that attenuates frequencies higher than 100kHz (typ). Enable the jitter filter by setting ENJITFILT = 1 (0x05, D6). PCLKIN Spread Tracking The serializer can operate with a spread PCLKIN signal. When using a spread PCLKIN signal, disable the jitter filter by setting ENJITFILT = 0 (0x05, D6). Do not exceed the spread limitations listed in Table 7 and keep modulation less than 40kHz. In addition, turn off spread spectrum in the serializer/deserializer. The serializer/ deserializer track the spread on PCLKIN. Changing the Clock Frequency It is recommended that the serial link be enabled after the video clock (fPCLKIN) and the control-channel clock (fUART/fI2C) are stable. When changing clock frequency, stop the video clock for 5Fs, apply the clock at the new frequency, then restart the serial link or toggle SEREN. On-the-fly changes in clock frequency are possible if the new frequency is immediately stable and without glitches. The reverse control channel remains unavailable for 350Fs after serial link start or stop. When using the UART interface, limit on-the-fly changes in fUART to factors of less than 3.5 at a time to ensure that the device recognizes the UART sync pattern. For example, when lowering the UART frequency from 1Mbps to 100kbps, first send data at 333kbps, then at 100kbps for reduction ratios of 3 and 3.333, respectively. Providing a Frame Sync (Camera Applications) The GPI and GPO provide a simple solution for camera applications that require a frame sync signal from the ECU (e.g., surround-view systems). Connect the ECU frame sync signal to the GPI input and connect the GPO output to the camera frame sync input. GPI/GPO have a typical delay of 275Fs. Skew between multiple GPI/ GPO channels is 115Fs (max). If a lower skew signal is required, connect the camera’s frame sync input to one of the serializer’s GPIOs and use an I2C broadcast write command to change the GPIO output state. This has a maximum skew of 1.5Fs, independent from the used I2C bit rate. Software Programming of the Device Addresses The serializer and deserializer have programmable device addresses. This allows multiple GMSL devices, along with I2C peripherals, to coexist on the same control channel. The serializer device address is in register 0x00 of each device, while the deserializer device address is in register 0x01 of each device. To change a device address, first 37 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive write to the device whose address changes (register 0x00 of the serializer for serializer device address change, or register 0x01 of the deserializer for deserializer device address change). Then write the same address into the corresponding register on the other device (register 0x00 of the deserializer for serializer device address change, or register 0x01 of the serializer for deserializer device address change). Three-Level Configuration Inputs CONF1 and CONF0 are three-level inputs that control the serial interface configuration and power-up defaults. Connect CONF1or CONF0 through a pullup resistor to IOVDD to set a high level, a pulldown resistor to GND to set a low level, or IOVDD/2 or open to set a midlevel. For digital control, use three-state logic to drive the threelevel logic inputs. Configuration Blocking The serializer can block changes to registers. Set CFGBLOCK to make all registers read only. Once set, the registers remain blocked until the supplies are removed or until PWDN is low. Compatibility with Other GMSL Devices The MAX9271 serializer is designed to pair with the MAX9272 deserializer, but interoperates with any GMSL deserializer. See Table 12 for operating limitations. GPIOs The serializer has five open-drain GPIOs available when not used as data or configuration inputs. Setting the GPIO enable bits (register 0x0E) to 1 enables the GPIOs and internally connects the respective data or configuration input low. Setting the GPIO output bits to 0 pulls the output low, while setting the bits to 1 leaves the output undriven, and pulled high through internal/external pullup resistors. The GPIO input buffers are enabled when the GPIO is enabled. The input states are stored in register 0x10 (read only). Set GPIO_OUT to 1 when using a GPIO_ as an input. Local Control-Channel Enable (LCCEN) The serializer provides inputs for limited configuration of the device when a FC is not connected. Connect LCCEN = low upon power-up to disable the local control channel, and enable the double-function configuration inputs (Table 13). All input configuration states are latched at power-up. Table 12. MAX9271 Feature Compatibility MAX9271 FEATURE GMSL Deserializer HSYNC/VSYNC encoding If feature not supported in the deserializer, must be turned off in the serializer. Hamming-code error correction If feature not supported in the deserializer, must be turned off in the serializer. I2C-to-I2C If feature not supported in the deserializer, must use UART-to-I2C or UART-to-UART. CRC error detection If feature not supported in the deserializer, must be turned off in the serializer. Double input If feature not supported in the deserializer, data is output as a single word at half the input frequency. Coax If feature not supported in the deserializer, Must connect unused serial input through 200nF and 50I in series to AVDD, and set the reverse control-channel amplitude to 100mV. I2S encoding If supported in the deserializer, disable I2S in the deserializer. Table 13. Double-Function Configuration LCCEN GPIO1/BWS FUNCTION MS/HVEN FUNCTION RX/SDA/EDC FUNCTION TX/SCL/DBL FUNCTION High Functions as GPIO MS input (low = base mode high = bypass mode) UART/I2C input/output UART/I2C input/output Low BWS input (low = 24-bit mode, high = 32-bit mode) HVEN input (low = HS/VS encoding disabled, high = HS/VS encoding enabled) EDC input (low = error detection/correction disabled, high = error detection/ correction enabled DBL input (low = single input, high = double input) 38 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Internal Input Pulldowns The control and configuration inputs (except three-level inputs) include a pulldown resistor to GND. External pulldown resistors are not needed. Choosing I2C/UART Pullup Resistors I2C The and UART open-drain lines require a pullup resistor to provide a logic-high level. There are tradeoffs between power dissipation and speed, and a compromise may be required when choosing pullup resistor values. Every device connected to the bus introduces some capacitance even when the device is not in operation. I2C specifies 300ns rise times (30% to 70%) for fast mode, which is defined for data rates up to 400kbps (see the I2C specifications in the AC Electrical Characteristics table for details). To meet the fast-mode rise-time requirement, choose the pullup resistors so that rise time tR = 0.85 x RPULLUP x CBUS < 300ns. The waveforms are not recognized if the transition time becomes too slow. The serializer supports I2C/UART rates up to 1Mbps (UARTto-I2C mode) and 400kbps (I2C-to-I2C mode). AC-Coupling AC-coupling isolates the receiver from DC voltages up to the voltage rating of the capacitor. Capacitors at the serializer output and at the deserializer input are needed for proper link operation and to provide protection if either end of the cable is shorted to a battery. AC-coupling blocks low-frequency ground shifts and low-frequency common-mode noise. Table 14. Typical Power-Supply Currents (Using Worst-Case Input Pattern) PCLK (MHz) AVDD (mA) DVDD (mA) IOVDD (mA) 25 50 36.8 9.0 0.32 42.1 13.7 0.34 Selection of AC-Coupling Capacitors Voltage droop and the digital sum variation (DSV) of transmitted symbols cause signal transitions to start from different voltage levels. Because the transition time is fixed, starting the signal transition from different voltage levels causes timing jitter. The time constant for an AC-coupled link needs to be chosen to reduce droop and jitter to an acceptable level. The RC network for an AC-coupled link consists of the CML/coax receiver termination resistor (RTR), the CML/coax driver termination resistor (RTD), and the series AC-coupling capacitors (C). The RC time constant for four equal-value series capacitors is (C x (RTD + RTR))/4. RTD and RTR are required to match the transmission line impedance (usually 100I differential, 50I single-ended). This leaves the capacitor selection to change the system time constant. Use 0.2FF or larger high-frequency surface-mount ceramic capacitors, with sufficient voltage rating to withstand a short to battery, to pass the lower speed reverse control-channel signal. Use capacitors with a case size less than 3.2mm x 1.6mm to have lower parasitic effects to the high-speed signal. Power-Supply Circuits and Bypassing The serializer uses an AVDD and DVDD of 1.7V to 1.9V. All inputs and outputs, except for the serial output, derive power from an IOVDD of 1.7V to 3.6V that scales with IOVDD. Proper voltage-supply bypassing is essential for high-frequency circuit stability. Power-Supply Table Power-supply currents shown in the Electrical Characteristics table are the sum of the currents from AVDD, DVDD, and IOVDD. Typical currents from the individual power supplies are shown in Table 14. Cables and Connectors Interconnect for CML typically has a differential impedance of 100I. Use cables and connectors that have matched differential impedance to minimize impedance discontinuities. Coax cables typically have a characteristic impedance of 50I contact the factory for 75I operation). Table 15 lists the suggested cables and connectors used in the GMSL link. Table 15. Suggested Connectors and Cables for GMSL SUPPLIER Rosenberger CONNECTOR CABLE TYPE 59S2AX-400A5-Y RG174 Coax JAE MX38-FF A-BW-Lxxxxx STP Nissei GT11L-2S F-2WME AWG28 STP D4S10A-40ML5-Z Dacar 538 STP Rosenberger 39 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Board Layout Separate the LVCMOS logic signals and CML/coax highspeed signals to prevent crosstalk. Use a four-layer PCB with separate layers for power, ground, CML/coax, and LVCMOS logic signals. Layout PCB traces close to each other for a 100I differential characteristic impedance. The trace dimensions depend on the type of trace used (microstrip or stripline). Note that two 50I PCB traces 1MI HIGHVOLTAGE DC SOURCE CHARGE-CURRENTLIMIT RESISTOR CS 100pF Route the PCB traces for differential CML in parallel to maintain the differential characteristic impedance. Avoid vias. Keep PCB traces that make up a differential pair equal in length to avoid skew within the differential pair. ESD Protection RD 1.5kI DISCHARGE RESISTANCE STORAGE CAPACITOR do not have 100I differential impedance when brought close together—the impedance goes down when the traces are brought closer. Use a 50I trace for the singleended output when driving coax. DEVICE UNDER TEST Figure 34. Human Body Model ESD Test Circuit ESD tolerance is rated for Human Body Model, IEC 61000-4-2, and ISO 10605. The ISO 10605 and IEC 61000-4-2 standards specify ESD tolerance for electronic systems. The serial outputs are rated for ISO 10605 ESD protection and IEC 61000-4-2 ESD protection. All pins are tested for the Human Body Model. The Human Body Model discharge components are CS = 100pF and RD = 1.5kI (Figure 34). The IEC 61000-4-2 discharge components are CS = 150pF and RD = 330I (Figure 35). The ISO 10605 discharge components are CS = 330pF and RD = 2kI (Figure 36). RD 330I HIGHVOLTAGE DC SOURCE CHARGE-CURRENTLIMIT RESISTOR CS 150pF RD 2kI DISCHARGE RESISTANCE STORAGE CAPACITOR DEVICE UNDER TEST Figure 35. IEC 61000-4-2 Contact Discharge ESD Test Circuit HIGHVOLTAGE DC SOURCE CHARGE-CURRENTLIMIT RESISTOR CS 330pF DISCHARGE RESISTANCE STORAGE CAPACITOR DEVICE UNDER TEST Figure 36. ISO 10605 Contact Discharge ESD Test Circuit 40 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 16. Register Table (see Table 1) REGISTER ADDRESS 0x00 0x01 BITS NAME VALUE D[7:1] SERID XXXXXXX 0x02 Normal operation. 1 Registers 0x00 to 0x1F are read only. CFGBLOCK D[7:1] DESID XXXXXXX D0 — 0 D4 D[3:2] D[1:0] D[7:6] SS — PRNG SRNG D[5:0] SDIV Deserializer device address. Reserved. 000 No spread spectrum. 001 ±0.5% spread spectrum. 010 ±1.5% spread spectrum. 011 ±2% spread spectrum. 100 No spread spectrum. 101 ±1% spread spectrum. 110 ±3% spread spectrum. 111 ±4% spread spectrum. 1 Reserved. 00 12.5MHz to 25MHz pixel clock. 01 25MHz to 50MHz pixel clock. 10 Automatically detect the pixel clock range. 11 Automatically detect the pixel clock range. 00 0.5 to 1Gbps serial-bit rate. 01 1 to 2Gps serial-bit rate. 10 Automatically detect serial-bit rate. 11 Automatically detect serial-bit rate. 00 Calibrate spread-modulation rate only once after locking. 01 Calibrate spread-modulation rate every 2ms after locking. 10 Calibrate spread-modulation rate every 16ms after locking. 11 Calibrate spread-modulation rate every 256ms after locking. AUTOFM 0x03 Serializer device address. 0 D0 D[7:5] FUNCTION 000000 Autocalibrate sawtooth divider. XXXXXX Manual SDIV setting. See the Manual Programming of the Spread-Spectrum Divider section. DEFAULT VALUE 1000000 0 1001000 0 000 1 11 11 00 000000 41 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 16. Register Table (see Table 1) (continued) REGISTER ADDRESS BITS D7 0x04 NAME CLINKEN D5 PRBSEN D4 SLEEP INTTYPE Disable serial link. Reverse control-channel communication remains unavailable for 350Fs after the serializer starts/stops the serial link. 1 Enable serial link. Reverse control-channel communication remains unavailable for 350Fs after the serializer starts/stops the serial link. 0 Disable configuration link. 1 Enable configuration link. 0 Disable PRBS test. 1 Enable PRBS test. 0 Normal mode. 1 Activate sleep mode. 00 Local control channel uses I2C when I2CSEL = 0. 01 Local control channel uses UART when I2CSEL = 0. 10, 11 D1 D0 D7 D6 0x05 1 Enable reverse control channel from deserializer (receiving). 0 Disable forward control channel to deserializer (sending). 1 Enable forward control channel to deserializer (sending). 0 I2C conversion sends the register address when converting UART to I2C. 1 Disable sending of I2C register address when converting UART to I2C (command-byte-only mode). 0 Jitter filter disabled. 1 Jitter filter active. 00 Continuous PRBS length. 01 9.83Mbit PRBS length. 10 167.1Mbit PRBS length. 11 1341.5Mbit PRBS length. 00 Reserved. I2CMETHOD D[5:4] PRBSLEN D[3:2] — D1 ENWAKEN D0 Disable reverse control channel from deserializer (receiving). FWDCCEN ENWAKEP DEFAULT VALUE 1 0 0 0 01 Local control channel disabled. 0 REVCCEN ENJITFILT FUNCTION 0 SEREN D6 D[3:2] VALUE 0 Disable wake-up receiver. 1 Enable OUT- wake-up receiver during sleep mode. 0 Disable wake-up receiver. 1 Enable OUT- wake-up receiver during sleep mode. 1 1 0 0 00 00 0 1 42 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 16. Register Table (see Table 1) (continued) REGISTER ADDRESS BITS D[7:4] NAME CMLLVL 0x06 D[3:0] PREEMP VALUE FUNCTION 0000 Do not use. 0001 Do not use. 0010 100mV output level. 0011 150mV output level. 0100 200mV output level. 0101 250mV output level. 0110 300mV output level. 0111 350mV output level. 1000 400mV output level. Power-up default when twisted-pair output is selected (Table 9). 1001 450mV output level. 1010 500mV output level. Power-up default when coax output is selected (Table 9). 1011 Do not use. 1100 Do not use. 1101 Do not use. 1110 Do not use. 1111 Do not use. 0000 Preemphasis off. 0001 -1.2dB preemphasis. 0010 -2.5dB preemphasis. 0011 -4.1dB preemphasis. 0100 -6.0dB preemphasis. 0101 Do not use. 0110 Do not use. 0111 Do not use. 1000 1.1dB preemphasis. 1001 2.2dB preemphasis. 1010 3.3dB preemphasis. 1011 4.4dB preemphasis. 1100 6.0dB preemphasis. 1101 8.0dB preemphasis. 1110 10.5dB preemphasis. 1111 14.0dB preemphasis. DEFAULT VALUE 1000, 1010 0000 43 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 16. Register Table (see Table 1) (continued) REGISTER ADDRESS BITS D7 D6 D5 D4 NAME DRS D2 D[1:0] D7 Single-input mode. Power-up default when LCCEN = high or TX/SCL/DBL = low. 1 Double-input mode. Power-up default when LCCEN = low and TX/SCL/DBL = high. 0 High data-rate mode. 1 Low data-rate mode. 0 24-bit mode. Power-up default when LCCEN = high or GPIO1/BWS = low. 1 32-bit mode. Power-up default when LCCEN = low and GPIO1/BWS = high. 0 Input data latched on rising edge of PCLKIN. Power-up default determined by CONF1 and CONF0 (Table 9). Do not change this value while the pixel clock is running. 1 Input data latched on falling edge of PCLKIN. Power-up default determined by CONF1 and CONF0 (Table 9). Do not change this value while the pixel clock is running. 0 Reserved. 0 HS/VS encoding disabled. Power-up default when LCCEN = high or MS/HVEN = low. 1 HS/VS encoding enabled. Power-up default when LCCEN = low and MS/HVEN = high. 00 1-bit parity error detection (GMSL compatible). Power-up default when LCCEN = high or RX/SDA/EDC = low. 01 6-bit CRC error detection. 10 6-bit hamming code (single-bit error correct, double-bit error detect) and 16 word interleaving. Power-up default when LCCEN = low and RX/SDA/EDC = high. 11 Do not use. 0 No VS or DIN0 inversion. 1 Invert VS when HVEN = 1. Invert DIN0 when HVEN = 0. Do not use if DBL = 0 in the serializer and DBL = 1 in the deserializer. 0 No HS or DIN1 inversion. 1 Invert HS when HVEN = 1. Invert DIN1 when HVEN = 0. Do not use if DBL = 0 in the serializer and DBL = 1 in the deserializer. BWS ES — HVEN EDC INVVS 0x08 D6 INVHS D[5:0] — FUNCTION 0 DBL 0x07 D3 VALUE 000000 Reserved. DEFAULT VALUE 0, 1 0 0, 1 0, 1 0 0, 1 00, 10 0 0 000000 44 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 16. Register Table (see Table 1) (continued) REGISTER ADDRESS 0x09 0x0A 0x0B 0x0C BITS NAME VALUE D[7:1] I2CSRCA XXXXXXX D0 — 0 D[7:1] I2CDSTA XXXXXXX D0 — 0 D[7:1] I2CSRCB XXXXXXX FUNCTION I2C address translator source A. Reserved. I2C address translator destination A. Reserved. I2C address translator source B. D0 — 0 D[7:1] I2CDSTB XXXXXXX D0 — 0 Reserved. 0 Acknowledge not generated when forward channel is not available. 1 I2C-to-I2C slave generates local acknowledge when forward channel is not available. 00 352ns/117ns I2C setup/hold time. D7 D[6:5] I2CLOCACK I2CSLVSH 0x0D D[4:2] D[1:0] I2CMSTBT I2CSLVTO Reserved. I2C address translator destination B. 01 469ns/234ns I2C setup/hold time. 10 938ns/352ns I2C setup/hold time. 11 1046ns/469ns I2C setup/hold time. 000 8.47kbps (typ) I2C-to-I2C master bit-rate setting. 001 28.3kbps (typ) I2C-to-I2C master bit-rate setting. 010 84.7kbps (typ) I2C-to-I2C master bit-rate setting. 011 105kbps (typ) I2C-to-I2C master bit-rate setting. 100 173kbps (typ) I2C-to-I2C master bit-rate setting. 101 339kbps (typ) I2C-to-I2C master bit-rate setting. 110 533kbps (typ) I2C-to-I2C master bit-rate setting. 111 837kbps (typ) I2C-to-I2C master bit-rate setting. 00 64Fs (typ) I2C-to-I2C slave remote timeout. 01 256Fs (typ) I2C-to-I2C slave remote timeout. 10 1024Fs (typ) I2C-to-I2C slave remote timeout. 11 No I2C-to-I2C slave remote timeout. DEFAULT VALUE 0000000 0 0000000 0 0000000 0 0000000 0 1 01 101 10 45 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 16. Register Table (see Table 1) (continued) REGISTER ADDRESS 0x0E 0x0F 0x10 BITS NAME D7 DIS_REV_P D6 DIS_REV_N D5 GPIO5EN D4 GPIO4EN D3 GPIO3EN D2 GPIO2EN D1 GPIO1EN D0 D[7:6] — — D5 GPIO5OUT D4 GPIO4OUT D3 GPIO3OUT D2 GPIO2OUT D1 GPIO1OUT D0 SETGPO D[7:6] — D5 GPIO5IN D4 GPIO4IN D3 GPIO3IN D2 GPIO2IN D1 GPIO1IN D0 GPO_L VALUE FUNCTION 0 OUT+ reverse channel receiver enabled. 1 OUT+ reverse channel receiver disabled. 0 OUT- reverse channel receiver enabled. 1 OUT- reverse channel receiver disabled. 0 Disable GPIO5. 1 Enable GPIO5. 0 Disable GPIO4. 1 Enable GPIO4. 0 Disable GPIO3. 1 Enable GPIO3. 0 Disable GPIO2. 1 Enable GPIO2. 0 Disable GPIO1. 1 Enable GPIO1. 0 11 0 1 0 1 0 1 0 1 0 1 0 1 00 0 1 0 1 0 1 0 1 0 1 0 1 Reserved. Reserved. Set GPIO5 low. Set GPIO5 high. Set GPIO4 low. Set GPIO4 high. Set GPIO3 low. Set GPIO3 high. Set GPIO2 low. Set GPIO2 high. Set GPIO1 low. Set GPIO1 high. Set GPO low. Set GPO high. Reserved. GPIO5 is low GPIO5 is high. GPIO4 is low. GPIO4 is high. GPIO3 is low. GPIO3 is high. GPIO2 is low. GPIO2 is high. GPIO1 is low. GPIO1 is high. GPO is set low. GPO is set high. DEFAULT VALUE 0 1 0 0 0 0 1 0 11 1 1 1 1 1 0 00 1 (read only) 1 (read only) 1 (read only) 1 (read only) 1 (read only) 0 (read only) 46 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Table 16. Register Table (see Table 1) (continued) REGISTER ADDRESS BITS NAME VALUE FUNCTION DEFAULT VALUE D[7:6] ERRGRATE D[5:4] ERRGTYPE D[3:2] ERRGCNT D1 ERRGPER D0 ERRGEN 0x12 D[7:0] — 00 01 10 11 00 01 10 11 00 01 10 11 0 1 0 1 01000000 0x13 D[7:0] — 00100010 Reserved. 00100010 0x14 D[7:0] — XXXXXXXX Reserved. 00000000 (read only) D7 CXTP D6 I2CSEL D5 LCCEN D[4:2] — 0x11 0x15 Generate an error every 2560 bits. Generate an error every 40,960 bits. Generate an error every 655,360 bits. Generate an error every 10,485,760 bits. Generate single-bit errors. Generate 2 (8b/10b) symbol errors. Generate 3 (8b/10b) symbol errors. Generate 4 (8b/10b) symbol errors. Continuously generate errors. 16 generated errors. 128 generated errors. 1024 generated errors. Disable periodic error generation. Enable periodic error generation. Disable error generator. Enable error generator. Reserved. 01000000 0 CXTP is low. 1 CXTP is high. 0 Input is high. 1 Input is low. 0 Input is high. 1 Input is low. 000 Reserved. 0 Output disabled. 1 Output enabled. 0 Valid PCLKIN detected. 1 Valid PCLKIN not detected. 00 00 00 0 0 0 (read only) 0 (read only) 0 (read only) 000 (read only) 0 (read only) D1 OUTPUTEN D0 PCLKDET 0x16 D[7:0] — XXXXXXXX Reserved. 00000000 (read only) 0x17 D[7:0] — XXXXXXXX Reserved. 00000000 (read only) 0x1E D[7:0] ID 00001001 Device identifier (MAX9271 = 0x09). 00001001 (read only) D[7:5] — 000 Reserved. 000 (read only) D4 CAPS D[3:0] REVISION 0x1F 0 (read only) 0 Not HDCP capable. 1 HDCP capable. 0 (read only) XXXX Device revision. (read only) 47 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Typical Application Circuit CAMERA APPLICATION PCLK RGBHV SHDN CAMERA PCLKOUT PCLKIN PCLK DOUT0–DOUT15 DIN0–DIN15 RGBHV GPO CONF1 GPU CONF0 MAX9271 MAX9272 RX/SDA/EDC TX TX/SCL/ES RX UART TO PERIPHERALS RX/SDA/EDC TX/SCL/DBL OUT+ OUT- GPI IN+ LOCK IN- CX/TP LCCEN ECU NOTE: NOT ALL PULLUP/PULLDOWN RESISTORS ARE SHOWN. SEE PIN DESCRIPTION FOR DETAILS. Ordering Information PART TEMP RANGE PIN-PACKAGE MAX9271GTJ/V+ -40NC to +105NC 32 TQFN-EP* /V denotes an automotive qualified part. +Denotes a lead(Pb)-free/RoHS-compliant package. *EP = Exposed pad. Chip Information Package Information For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 32 TQFN-EP T3255+5 21-0140 90-0013 PROCESS: CMOS 48 MAX9271 16-Bit GMSL Serializer with Coax or STP Cable Drive Revision History REVISION NUMBER REVISION DATE 0 7/12 DESCRIPTION Initial release PAGES CHANGED — Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated Products, Inc. 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000 © 2012 Maxim Integrated Products 49 Maxim is a registered trademark of Maxim Integrated Products, Inc.