F MADE O ING SETT THERMO RIAL MATE ADVANCE GRP System Switched Interlocked socket outlets ADVANCE GRP System > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STANDARDS EN 60309-1 Plugs, socket outlets and couplers for industrial purposes. Part 1: general requirements. EN 60309-2 Plugs, socket outlets and couplers for industrial purposes. Part 2: dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations. EN 60309-4 Plugs, socket-outlets and couplers for industrial purposes. Part 4: Switched socket-outlets and connectors with or without interlock. > VERSIONS WITH MECHANICAL INTERLOCK With switch-disconnector With switch-disconnector and fuse 2 > TECHNICAL CHARACTERISTICS Rated current: 16A-32A-63A Rated voltage: 100÷690V~ Frequency: 50÷60Hz Insulating voltage: 500/690V~ Protection degree: IP66/IP67 Operating temperature according to the reference standard: -25°C +40°C Minimum operating temperature: -40°C Max. operating temperature: +60°C Self-extinguishing GW test: 960°C Self-extinguishing UL94: V0 Material: Thermosettting IK degree at 20°C: IK10 (20J) Switch-disconnectors 16A-32A-63A: COMMAND Series Fuse: 16A-32A 63A gG 10,3x38mm gG 22x58mm Colour: Grey RAL7037 Saline solution Resistant Bases Acids Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Limited Resistance Resistant Limited Resistance Resistant Resistant Resistant Resistant Resistant Mineral oil UV rays Resistant Resistant ADVANCE GRP System > BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS For specific substances please contact our technical service. > CABLE ENTRY Maximum entry with cable glands Single socket Socket with switchboard Rated current (A) Upper Lower Upper Lower Side 16A / 32A M32 M32 M32 M32 M32 63A M40 M40 M40 M40 M32 > WIRING OPERATIONS Wiring capacity of the terminals (mm2) Socket outlets Plugs Rated current (A) Min Max Min Max 16A 1,5 4 1 2,5 32A 2,5 10 2,5 6 63A 6 25 6 16 > PADLOCK TO BE USED Choice of padlock for socket knob, fuse door and switchboard door Rated current (A) Padlock arc diameter (mm) 16A-32A 5 63A 6,3 125A 6,3 ØD 3 ADVANCE GRP System > SPECIAL CHARACTERISTICS ADVANCE GRP CHARACTERISTICS The ADVANCE GRP product line includes a series of 16A, 32A, 63A, 125A interlocked sockets (compliant with EN60309-4 standards) and the casings to contain them. It's the most complete range of interlocked sockets produced in GRP (Glass Reinforced Polyester) thermosetting material. A unique feature which enhances the exceptional mechanical strength of ADVANCE GRP products is the SMC (Sheet Moulding Compound) production process used for the casings. SMC is a technology which uses exclusively non-woven sheets, pre-impregnated with polyester resin. This method consists in preparing the sheet material inside a mould which, equipped with a negative mould, presses the composite so as to allow compaction. SMC is an advanced technology which enhances the quality of the raw material without reducing the high-strength characteristics during transformation; it's a high-performing technology in terms of the mechanical performance of the resultant product (glass fibre length, homogeneity of the material, integrity of the fibres). On the contrary, the BMC (Bulk Moulding Compound) technology is a technology for moulding composite materials which uses a raw material available in "blocks" (short, charged fibres) which are subjected to high thermomechanical stress during the transformation process, consequently diminishing the mechanical properties of the details, thereby reducing the impact strength and flexural strength. The glass-fibre reinforced polyester used in ADVANCE GRP guarantees excellent mechanical strength and a long lifetime: this material is highly resistant to contamination, completely corrosion resistant and suited for applications requiring the use of components with low smoke emission and no halogens, LSOH (Low Smoke Zero Halogen) components. The outstanding properties of the material are also guaranteed over time, thanks to the high RTI value (Relative Temperature Index), measured to be 20,000h. Numerous verifications and tests have been carried out, even UV resistance tests, in order to guarantee the long duration of the material's initial performance. The thickness of the walls is sufficient to offer an excellent alternative to aluminium, stainless steel or cast iron. OUTSTANDING HEAT AND FIRE RESISTANCE The glass-fibre reinforced polyester used in ADVANCE GRP guarantees excellent heat and fire resistance: it does not propagate flames, emit halogens or smoke. This material has outstanding flame retardancy: Glow Wire 960°C according to EN 60695-2-1; V0 according to UL94. It's suited for applications requiring the use of components with low smoke emission and no halogens, LSOH (Low Smoke Zero Halogen). 4 ADVANCE GRP System OUTSTANDING IMPACT RESISTANCE The glass-fibre reinforced polyester used in ADVANCE GRP and the high thickness of the casing walls guarantee an excellent mechanical resistance to impacts. The SMC technology used to produce the casings makes ADVANCE GRP an indestructible product. The impact resistance of the casings is higher than 20J (IK10) according to EN50102, even under limit temperature conditions (-40°C +60°C). RESISTANCE TO CHEMICAL AGENTS The ADVANCE GRP interlocked sockets and casings, thanks to the glass-fibre reinforced polyester with which they are produced, have excellent resistance to aggressive chemical substances, saline solutions, diluted acids, hydrocarbons, mineral oils, alcoholic substances. They are ideal for use in highly corrosive atmospheres. RESISTANCE TO ATMOSPHERIC AGENTS The structure and materials used also make ADVANCE GRP a product suited for the most extreme environmental conditions. The double degree of protection IP66 and IP67 (IP66 for 125A), guarantees an excellent seal against the entry of solid objects or liquids into the casings. Outstanding resistance to UV radiation, exceptional reliability under environmental stress and use at both low and high ambient temperatures (-40°C +60°C). EX VERSIONS The ADVANCE GRP product line also includes a series of 16A, 32A, 63A and 125A interlocked sockets for installation in environments with a potential risk of explosion identified as zone 22 (dust) which fall under the area of application of the Atex Directive (European Directive 94/9/EC), compliant with the standards EN61241-0 and EN61241-1. Type of protection : Ex II 3D - Ex tD A22 IP66 T90°C Ta -25°C +60°C. 5 ADVANCE GRP System > APPLICATION EXAMPLES 6 16A 32A 16A 32A with and without fuse 63A 125A Vac 690 690 690 690 690 750 Vdc 400 400 400 400 - 750 with fuse Rated insulation voltage Ui without fuse Rated impulse withstand voltage Uimp kV 4 4 4 4 8 12 Thermal current Ith A 25 32 30 40 63 200 Thermal current Ithe A 25 32 30 40 63 - 400V A - - - - - 200 500V A - - - - - - 690V A 25 32 30 32 63 160 400V A - - - - - 200 500V A - - - - - - 690V A 30 32 20 32 63 160 400V A - - 20 32 63 135 500V A - - - - 40 125 690V A 16 25 16 25 30 80 AC21A Nominal current rating Ie AC22A AC23A AC3 Resistite loads, inluding moderate overloads Mixed resistite and inductive loads, including moderate overloads Switching off motor loads or other highly inductive loads (3 phase/3 pole) Squirrel-cage motor: starting, switching off motor during running (3 phase/ 3 pole) DC21A Resistite loads, including Moderate overloads DC22A Mixed resistite and inductive loads, including moderate overloads 400V A - 28,5 - 28,5 40 - 690V A 12 20 12 20 25 - 300V A 25 32 20 32 - 160(*) 250V A 20 32 25 32 - 160(*) - - 600V A Rated short-time withstand current Icw (s) Short-circuit protection Rated current UL 400 400 400 1500 kAeff 10 10 10 10 10 32 16 32 63 Associate fuse size for conditional short-circuit current - Type gG A Rated short-circuit making capacity Icm A General applications - Single-phase and Three-phase AC motor, all-pole interruption - Single-phase AC motor, B, C, D, all-pole interruption - Three-phase Permissible wire range 400 A Conditional short-circuit current Flexible wire Rigid wire (*) 2+2 poles in series IMQ approved 10(*) 10(*) 16 4000 24 1500 1500 1500 1500 2850 24000 600V A 20 30 32 40 63 125 120V Hp 1,5 2 1,5 2 3 7,5 240V Hp 3 5 3 5 7,5 20 240V Hp 480V Hp 600V Hp 7,5 10 15 10 15 20 7,5 10 15 10 15 20 10 20 25 40 75 100 mm2 1,5-10 1,5-10 1,5-10 1,5-10 10-35 10-70 AWG 16-8 16-8 16-8 16-8 10-2 8-1/10 mm2 1,5-16 1,5-16 1,5-16 1,5-16 10-35 10-70 AWG 16-8 16-8 16-8 16-8 10-2 8-1/10 UL approved 7 ADVANCE GRP System > TECHNICAL DATA SWITCH DISCONNECTORS ADVANCE GRP System > TECHNICAL CHARACTERISTICS 16A-32A-63A VERSIONS Ample space for easy wiring Outdoor wall fastening Under-plate cable runway Switch-disconnector with mechanical lock that can be accessorized with auxiliary contacts Threaded metal inserts Easily extractable support Possibility for pluginserted control microswitch assembly BOTTOM VIEW TOP VIEW Module in high-temperature resistant engineering polymer Possible entry from bottom side (input-output also) 8 Self-centering punch marks to facilitate drilling ADVANCE GRP System Single-piece waterproof gasket High-strength material with superior UV and chemical resistance Ergonomic knob which can be padlocked in position 0 and 1, manoeuvrable even with gloves Fuse inspection door, tamperproof, lockable, with assisted opening Cover entirely separate from the base for easy installation Dual mechanical lock as required by the ATEX Directive Captive stainless steel closing screws I-Device An electronic device controls (Intelligence Device) the status of the interlocked socket, monitoring the electrical functionality: - operation of the signalling and control card is guaranteed even when the load is not connected; INDICATOR LIGHT ON - indicates that the fuses are not open and all the phases are present; - indicates that the socket outlet is powered correctly; INDICATOR LIGHT FLASHING - signals the interruption of one or more fuses; - signals the absence of a phase*; INDICATOR LIGHT OFF - indicates that the socket outlet is not powered. * for single-phase products in the event of phase/neutral loss led signaling appears off. 9 ADVANCE GRP System > IP66/IP67 WITHOUT BASE VERSION - VOLTAGE >50V Without fuse holder Poles 2P+E 3P+E 3P+N+E Colour 16A 32A 63A h. 1 1 1 Hz Volt 50/60 100-130 4 402.1670 402.3270 402.6370 50/60 200-250 6 402.1683 402.3283 402.6383 50/60 380-415 9 402.1678 402.3278 402.6378 50/60 480-500 7 402.16836 402.32836 402.63836 50/60 trasf. 12 402.16833 402.32833 402.63833 >300-500 >50 2 402.16832 402.32832 402.63832 c.c. >50-250 3 - - - c.c. >250 8 - - - 50/60 100-130 4 402.1672 402.3272 402.6372 50/60 200-250 9 402.1674 402.3274 402.6374 50/60 380-415 6 402.1686 402.3286 402.6386 60 440-460 11 402.16865 402.32865 402.63865 50/60 480-500 7 402.16866 402.32866 402.63866 50/60 600-690 (2) 5 402.16867 402.32867 402.63867 50…60 380…440 3 402.16864 402.32864 402.63864 100-300 >50 (1) 10 402.16861 402.32861 402.63861 >300-500 >50 (1) 2 402.16862 402.32862 402.63862 50/60 100-130 4 402.1679 402.3279 402.6379 50/60 208-250 9 402.1675 402.3275 402.6375 50/60 346-415 6 402.1687 402.3287 402.6387 50/60 480-500 7 402.16876 402.32876 402.63876 50/60 600-690 (2) 5 402.16877 402.32877 402.63877 60 440-460 11 402.16875 402.32875 402.63875 50…60 380…440 3 402.16874 402.32874 402.63874 >300-500 >50 2 402.16872 402.32872 402.63872 (1) (1) (1) Versions >60Hz = 25% Reduced current. (2) Particular attention is required in selecting the fuse suited to the system's voltage. Pack Quantity. 10 ADVANCE GRP System With fuse holder 16A 32A 63A 1 1 1 402.1670-F 402.3270-F 402.6370-F 402.1683-F 402.3283-F 402.6383-F 402.1678-F 402.3278-F 402.6378-F 402.16836-F 402.32836-F 402.63836-F 402.16833-F 402.32833-F 402.63833-F 402.16832-F 402.32832-F 402.63832-F - - - - - - 402.1672-F 402.3272-F 402.6372-F 402.1674-F 402.3274-F 402.6374-F 402.1686-F 402.3286-F 402.6386-F 402.16865-F 402.32865-F 402.63865-F 402.16866-F 402.32866-F 402.63866-F 402.16867-F 402.32867-F 402.63867-F 402.16864-F 402.32864-F 402.63864-F 402.16861-F 402.32861-F 402.63861-F 402.16862-F 402.32862-F 402.63862-F 402.1679-F 402.3279-F 402.6379-F 402.1675-F 402.3275-F 402.6375-F 402.1687-F 402.3287-F 402.6387-F 402.16876-F 402.32876-F 402.63876-F 402.16877-F 402.32877-F 402.63877-F 402.16875-F 402.32875-F 402.63875-F 402.16874-F 402.32874-F 402.63874-F 402.16872-F 402.32872-F 402.63872-F Base Base with consumer unit Base with derivation box Bases and switchboards available on page 16 11 ADVANCE GRP System > IP66/IP67 WITHOUT BASE VERSION I-Device IP66/IP67 - VOLTAGE >50V Without fuse holder Poles 2P+E 3P+E 3P+N+E 16A 32A 63A h. 1 1 1 Hz Volt 50/60 100-130 4 403.1670 403.3270 403.6370 50/60 200-250 6 403.1683 403.3283 403.6383 50/60 380-415 9 403.1678 403.3278 403.6378 50/60 480-500 7 403.16836 403.32836 403.63836 50/60 trasf. 12 403.16833 403.32833 403.63833 >300-500 >50 2 on request on request on request c.c. >50-250 3 - - - c.c. >250 8 - - - 50/60 100-130 4 403.1672 403.3272 403.6372 50/60 200-250 9 403.1674 403.3274 403.6374 50/60 380-415 6 403.1686 403.3286 403.6386 60 440-460 11 403.16865 403.32865 403.63865 50/60 480-500 7 403.16866 403.32866 403.63866 50/60 600-690 (2) 5 403.16867 403.32867 403.63867 50…60 380…440 3 403.16864 403.32864 403.63864 100-300 >50 (1) 10 on request on request on request >300-500 >50 (1) 2 on request on request on request 50/60 100-130 4 403.1679 403.3279 403.6379 50/60 208-250 9 403.1675 403.3275 403.6375 50/60 346-415 6 403.1687 403.3287 403.6387 50/60 480-500 7 403.16876 403.32876 403.63876 50/60 600-690 (2) 5 403.16877 403.32877 403.63877 60 440-460 11 403.16875 403.32875 403.63875 50…60 380…440 3 403.16874 403.32874 403.63874 >300-500 >50 2 on request on request on request Colour (1) (1) (1) Versions >60Hz = 25% Reduced current. (2) Particular attention is required in selecting the fuse suited to the system's voltage. Pack Quantity. 12 ADVANCE GRP System With fuse holder 16A 32A 63A 1 1 1 403.1670-F 403.3270-F 403.6370-F 403.1683-F 403.3283-F 403.6383-F 403.1678-F 403.3278-F 403.6378-F 403.16836-F 403.32836-F 403.63836-F 403.16833-F 403.32833-F 403.63833-F on request on request on request - - - - - - 403.1672-F 403.3272-F 403.6372-F 403.1674-F 403.3274-F 403.6374-F 403.1686-F 403.3286-F 403.6386-F 403.16865-F 403.32865-F 403.63865-F 403.16866-F 403.32866-F 403.63866-F 403.16867-F 403.32867-F 403.63867-F 403.16864-F 403.32864-F 403.63864-F on request on request on request on request on request on request 403.1679-F 403.3279-F 403.6379-F 403.1675-F 403.3275-F 403.6375-F 403.1687-F 403.3287-F 403.6387-F 403.16876-F 403.32876-F 403.63876-F 403.16877-F 403.32877-F 403.63877-F 403.16875-F 403.32875-F 403.63875-F 403.16874-F 403.32874-F 403.63874-F on request on request on request Base Base with consumer unit Base with derivation box Bases and switchboards available on page 16 13 ADVANCE GRP System > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STANDARDS EN 60309-1 Plugs, socket outlets and couplers for industrial purposes. Part 1: general requirements. EN 60309-2 Plugs, socket outlets and couplers for industrial purposes. Part 2: dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations. > VERSIONS > TECHNICAL CHARACTERISTICS Version with transformer. SELV transformer 230/24V~ 150VA Version without transformer. Rated current: 16A-32A Rated voltage: 20÷50V~ Frequency: 50÷60Hz SELV transformer 220/24V: 150VA Insulating voltage: 500/690V~ Protection degree: IP66/IP67 Operating temperature according to the reference standard: -25°C +40°C Minimum operating temperature: -40°C Max. operating temperature: +60°C Self-extinguishing GW test: 850°C Material: Thermosetting IK degree at 20°C: IK10 Colour: Grey RAL7037 > BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS Saline solution Resistant Acids Bases Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Limited Resistance Resistant Limited Resistance Resistant Resistant Resistant Resistant Resistant For specific substances please contact our technical service. 14 Solvents Mineral oil UV rays Resistant Resistant Description With transformer (*) Plug Colour 2P-16A 2P-16A Without transformer 2P-32A Rated voltage 20-25V~ 1 20-25V~ 1 403.2420 40-50V~ 1 403.2421 20-25V~ 1 403.2620 40-50V~ 1 403.2416 403.2621 (*) SELV transformer g 220/24V~ 150VA. For the choice of bottoms, refer to the 16A-32A module. Pack Quantity. > WIRING OPERATIONS > SOCKET WITHOUT TRANSFORMER WIRING DIAGRAM Wiring capacity of the terminals (mm2) Rated current (A) ADVANCE GRP System > IP66/IP67 WITHOUT BASE VERSION - VOLTAGE <50V Socket outlets Min Max 16A 4 4 32A 4 10 2P 16A 2P 32A Note: external transformer 15 ADVANCE GRP System > IP66/IP67 BASES AND CONSUMER UNIT Description Base for one socket Description Base for one socket with derivation box Description Base for one socket with consumer unit Description Base for two sockets with derivation box Description Base for two sockets with consumer unit DIN Module modules HxB (mm) Power dissipation (W) 16A-32A - 260x130 - 1 63A - 380x170 - 1 HxB (mm) Power dissipation (W) DIN Module modules - 460x130 9 1 63A - 580x170 13 1 HxB (mm) Power dissipation (W) DIN Module modules 6 460x130 9 1 63A 8 580x170 13 1 HxB (mm) Power dissipation (W) DIN Module modules - 460x260 16 1 63A - - - - HxB (mm) Power dissipation (W) 579.5210 13 460x260 16 1 63A - - - - 63A 579.5111 579.5211 63A 579.5120 - 16A-32A 16A-32A 63A 579.5110 16A-32A 16A-32A DIN Module modules 579.5200 16A-32A 16A-32A 63A 579.5100 16A-32A 16A-32A Power dissipation in conformity with CEI 23-48 CEI 23-49. IP66/IP67 when coupled with the respective component. 16 16A-32A 63A 579.5121 Pack Quantity. ADVANCE GRP System > GALVANIZED STEEL SUPPORTS HxB (mm) Description 3 x 16A-32A 555x390 1 4 x 16A-32A 555x520 1 579.0030 579.0040 HxB (mm) Description 2 x 16A-32A + 1 x 63A 685x430 1 3 x 16A-32A + 1 x 63A 685x560 1 2 x 16A-32A + 2 x 63A 685x610 1 579.0021 597.0031 579.0022 Pack Quantity. > COMPOSITION EXAMPLES M32 bottom jointing Kit (page 18) 579.0030 579.0021 579.0040 579.0031 579.0022 17 ADVANCE GRP System > ACCESSORIES Description Contacts Microswitch Kit for Advance GRP 16A-32A-63A for plug-inserted control 1NO/1NC 579.0100 1/12 Max 1 kit for 16A-32A sockets; Max 2 kit for 63A sockets. Description 16A-32A-63A Junction box Kit IP66/IP67 M40 (*) 1/12 Junction box Kit IP66/IP67 M50 (*) 1/12 M32 bottom jointing Kit M32 1/12 (*) Includes cable gland and gasket. IP66/IP67 when coupled with the respective component. 63A 579.0200 579.0201 579.0332 Pack Quantity. > AUXILIARY CONTACTS Description NC contact NO contact For switches 16A-32A 10 590.PL004001 63A 10 590.PL004003 16A-32A 10 590.PL004002 63A 10 590.PL004004 NC= normally closed. NO= normally open. Pack Quantity. M32 bottom jointing Kit. Auxiliary contact assembled. 18 ADVANCE GRP System > AS PANELS Example of Mega Panel available in customized configuration. 19 ADVANCE GRP System > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STANDARDS EN 60309-1 Plugs, socket outlets and couplers for industrial purposes. Part 1: general requirements. EN 60309-2 Plugs, socket outlets and couplers for industrial purposes. Part 2: dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations. EN 60309-4 Plugs, socket-outlets and couplers for industrial purposes. Part 4: Switched socket-outlets and connectors with or without interlock. > VERSIONS WITH MECHANICAL INTERLOCK IEC 61241-0 / EN 61241-0 Electrical apparatus for use in the presence of combustible dust. With switch-disconnector Part 0: General requirements. IEC 61241-1 / EN 61241-1 Electrical apparatus for use in the presence of combustible dust. With switch-disconnector and fuse With molded case circuit breaker with thermal magnetic and residual current release trip units 125A With molded case circuit breaker with thermal magnetic trip unit 125A With fuse and switch-disconnector 125A Part 1: Protection by enclosures 'tD'. With contactor 20 125A > VERSIONS WITH ELECTRICAL INTERLOCK > PRODUCTS FOR USE IN A POTENTIALY EXPLOSIVE ENVIRONMENT Scame offers products suitable for installation into environments under potential risk of explosion identified as Zone 22 and that enter into the field of application for the ATEX Directive (European Directive 94/9/CE). Saline solution Resistant Acids Bases Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol Limited Resistance Resistant Limited Resistance Resistant Resistant Resistant Resistant Resistant Mineral oil UV rays Resistant Resistant For specific substances please contact our technical service. > TECHNICAL CHARACTERISTICS Rated current: 16A-32A-63A-125A Rated voltage: 100÷690V~ Frequency: 50÷60Hz Insulating voltage: 500/690V~ Self-extinguishing GW test: 960°C Self-extinguishing UL94: V0 Thermal magnetic protection: Molded case circuit breaker ABB Tmax T1B (16kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7…1 x In fixed magnetic threshold 10 x In) Thermal-magnetic and residual current protection: Molded case circuit breaker ABB Tmax T1B (16kA) with thermal magnetic trip unit TMD (adjustable thermal threshold 0,7…1 x In fixed magnetic threshold 10 x In) + residual current release trip units RC221/1 (adjustable residual current trip 0,03 - 0,1 - 3A and time limit for non-trip instantaneous) Version with contactor: Contactor CL09 GE POWER CONTROL Switch-disconnectors: 16A-32A-63A COMMAND Series 125A Switch ABB OT 160 Fuse: 16A-32A gG 10,3x38mm 63A gG 22x58mm 125A NH00 Colour: Grey RAL7037 ATEX Code: Ex Protection type: II 3D Ex tD A22 IP66 T90°C Ta -25°C +60°C > CABLE ENTRY Operating temperature Maximum entry with cable glands according to the -25°C +60°C Single socket Rated current (A) Upper Lower 16A-32A M32 M32 Switched socket outlets with 63A M40 M40 interlock degree of Protection: IP66 125A M63 M63 reference standard: Maximum permissible surface temperature: T90°C Plugs - degree of Protection: IP66/IP67 Impact Resistance: IK10 (20J) - (24V 4J) > WIRING OPERATIONS Wiring capacity of the terminals (mm2) Switched socket outlets with interlock material: Thermosetting Interlocked switch sockets outlets CE certificate: Socket outlets Plugs Rated current (A) Min Max Min Max 16A 4 4 2,5 2,5 16A-32A-63A SCAME ATEX 04 32A 10 10 6 6 125A: SCAME ATEX 02 63A 25 25 10 16 Plugs CE certificate: SCAME ATEX 03 125A 50 95 25 50 21 ADVANCE GRP System > BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS ADVANCE GRP System > MECHANICALLY INTERLOCKED SOCKET OUTLETS WITH Description Switchdisconnector Description Switchdisconnector and fuse (*) Socket Hz Volt Colour h I-Device 16A-32A-63A IP66 - VOLTAGE >50V 16A 32A 63A 2P+E 50/60 200-250V 6 1 503.1683 503.3283 503.6383 3P+E 50/60 380-415V 6 1 503.1686 503.3286 503.6386 3P+N+E 50/60 346-415V 6 1 503.1687 503.3287 503.6387 16A 32A 63A Socket Hz Volt Colour h 2P+E 50/60 200-250V 6 1 503.1683-F 503.3283-F 503.6383-F 3P+E 50/60 380-415V 6 1 503.1686-F 503.3286-F 503.6386-F 3P+N+E 50/60 346-415V 6 1 503.1687-F 503.3287-F 503.6387-F (*) Fuses not included. Pack Quantity. > WITH FUSE HOLDER IP66 - VOLTAGE <50V Description Socket With transformer (*) 2P-16A Colour Rated voltage 20-25V~ 579.0030 579.0040 EX batteries can be produced by request with special order. 22 503.2416-F 1 (*) SELV transformer g 220/24V~ 150VA. Pack Quantity. 579.0021 579.0031 579.0022 Description Contacts Microswitch Kit for Advance GRP 16A-32A-63A for plug-inserted control 1NO/1NC ADVANCE GRP System > ACCESSORIES AND COMPLEMENTARY PRODUCTS 579.0100 1/12 Max 1 kit for 16A-32A sockets; Max 2 kit for 63A sockets. > AUXILIARY CONTACTS For switches Description NC contact NO contact 16A-32A 10 590.PL004001 63A 10 590.PL004003 16A-32A 10 590.PL004002 63A 10 590.PL004004 NC= normally closed. NO= normally open. Pack Quantity. > COMPLEMENTARY PRODUCTS - OPTIMA EX SERIES - PLUGS 16A-32A-63A IP66/IP67 Description Plug 16A 32A 63A 1 218.EX1633 218.EX3233 218.EX6333 6 1 218.EX1636 218.EX3236 218.EX3236 6 1 218.EX1637 218.EX3237 218.EX6337 Poles Hz Volt 2P+E 50/60 200-250V 6 3P+E 50/60 380-415V 3P+N+E 50/60 346-415V Hz Volt 50/60 20-25 Description Poles Plug 2P Colour Colour h 16A h - 1 235.EX1600 Pack Quantity. 23 ADVANCE GRP System > TECHNICAL CHARACTERISTICS VERSION 125A Outdoor wall fastening Ample space for easy wiring Under-plate cable runway Threaded metal inserts Switch-disconnector with mechanical lock that can be accessorized with auxiliary contacts Punched marks for easy closure of the cover Easily extractable bottom plate Possibility to assemble microswitch BOTTOM VIEW TOP VIEW Module in high-temperature resistant engineering polymer Possible entry from bottom side (input-output also) 24 Self-centering punch marks to facilitate drilling Rating on metal plate ADVANCE GRP System Single-piece waterproof gasket Captive stainless steel closing screws Ergonomic knob which can be padlocked in position 0 and 1, manoeuvrable even with gloves High-strength material with superior UV and chemical resistance Dual mechanical lock as required by the ATEX Directive Residual current release trip units test push button Cover entirely separate from the base for easy installation I-Device An electronic device controls (Intelligence Device) the status of the interlocked socket, monitoring the electrical functionality: - operation of the signalling and control card is guaranteed even when the load is not connected; INDICATOR LIGHT ON - indicates that the fuses are not open and all the phases are present; - indicates that the socket outlet is powered correctly; INDICATOR LIGHT FLASHING - signals the interruption of one or more fuses; - signals the absence of a phase*; INDICATOR LIGHT OFF - indicates that the socket outlet is not powered. * for single-phase products in the event of phase/neutral loss led signaling appears off. 25 ADVANCE GRP System > MECHANICALLY INTERLOCKED Description Switchdisconnector Description Switchdisconnector and fuse (*) Description Fuse (*) and switchdisconnector Description Plug Hz Volt 2P+E 125A 50/60 200-250V 6 1 503.12583 3P+E 125A 50/60 380-415V 6 1 503.12586 3P+N+E 125A 50/60 346-415V 6 1 503.12587 h Volt 2P+E 125A 50/60 200-205V 6 1 503.12583-F 3P+E 125A 50/60 380-415V 6 1 503.12586-F 3P+N+E 125A 50/60 346-415V 6 1 503.12587-F Colour Volt 2P+E 125A 50/60 200-205V 6 1 503.12583-FS 3P+E 125A 50/60 380-415V 6 1 503.12586-FS 3P+N+E 125A 50/60 346-415V 6 1 503.12587-FS Plug Hz Plug Hz (*) Fuses not included Volt Colour h Hz Plug Molded case circuit 2P+E 125A 50/60 breaker with thermal magnetic 3P+E 125A 50/60 and residual current release trip units 3P+N+E 125A 50/60 26 Colour Hz Plug Molded case 2P+E 125A 50/60 circuit breaker 3P+E 125A 50/60 with thermal magnetic trip unit 3P+N+E125A 50/60 Description I-Device SOCKET OUTLETS 125A - IP66 Colour h h 200-205V 6 1 503.12583-M 380-415V 6 1 503.12586-M 346-415V 6 1 503.12587-M Volt Colour h 200-205V 6 1 503.12583-RM 380-415V 6 1 503.12586-RM 346-415V 6 1 503.12587-RM Pack Quantity. Description Contactor (*) Hz Volt 2P+E 125A 50/60 200-205V 6 1 503.12583-T 3P+E 125A 50/60 380-415V 6 1 503.12586-T 3P+N+E 125A 50/60 346-415V 6 1 503.12587-T Plug Colour ADVANCE GRP System > ELECTRICALLY INTERLOCKED SOCKET OUTLETS - IP66 h (*) Microswitch already provided. Contactor operated by microswitch. Pack Quantity. > ACCESSORIES Description Contacts Terminals Microswitch kit 400V 10A 1NO+1NC (microswitch + terminal block) 579.0125 4x4 mm2 Max 2 kit. For products with mechanical interlock. > COMPLEMENTARY PRODUCTS - OPTIMA-EX SERIES - PLUGS 125A IP66/IP67 Description Plugs Plug Hz Volt Colour h 2P+E 125A 50/60 200-250V 6 1 218.EX12533 3P+E 125A 50/60 380-415V 6 1 218.EX12536 3P+N+E 125A 50/60 346-415V 6 1 218.EX12537 Pack Quantity. 27 ADVANCE GRP System > VERSION 16A-32A-63A BASES AND CONSUMER UNIT DIMENSIONS VERSION 579.5110 579.5111 579.5121 579.5120 579.5210 579.5211 A 460 460 460 460 580 580 B 130 130 260 260 170 170 C 260 260 260 260 380 380 D 150 150 168 E 137 137 137 137 181,5 181,5 F 31 31 31 31 35 35 G 198 198 198 198 310 310 H 114 114 244 244 150 150 I 8 8 8 8 10 10 (Dimensions in mm) 28 ADVANCE GRP System > VERSION 16A-32A-63A SOCKET DIMENSIONS VERSION 2P+E 16A 3P+E 16A 3P+N+E 16A 2/3P+E 32A 3P+N+E 32A 2P+E 63A 3P+E 63A 3P+N+E 63A A 260 260 260 260 260 B 130 130 130 130 130 C 360 365 390 390 400 D 280 282 282 285 286 E 170 175 182 189 185 F 164 164 164 164 164 G 114,5 114,5 114,5 114,5 114,5 H 7,75 7,75 7,75 7,75 7,75 I 198 198 198 198 198 L 31 31 31 31 31 M 25 25 25 25 25 N 33,5 33,5 33,5 33,5 33,5 380 170 550 420 225 203 150 8,3 310 35 32,5 40 (Dimensions in mm) 29 ADVANCE GRP System > VERSION 125A SOCKET DIMENSIONS (Dimensions in mm) 30 Switch-disconnector and fuse Fuse and switch Molded case circuit breaker with thermal magnetic trip unit Molded case circuit breaker with thermal magnetic and residual current release trip units Contactor ADVANCE GRP System Switch-disconnector (Dimensions in mm) 31