EHS
Technical Data Book
EHS Split for Europe
Model : AE***JNYDEH/EU
AE***JXEDEH/EU
I. Products
1. Nomenclature …….……………………….…….………… 4
2. Line-up ……………………….…………….……….……… 6
3. System Specification……………………………………… 7
II. Outdoor Unit
1. Specifications ………………...……..…...….…..………. 12
2. Capacity Tables ………....................……….….………. 16
3. Capacity Correction ……...……………………………… 19
4. Dimensional Drawings ………...………..………………. 20
5. Cycle Diagrams …………………………………………. 23
6. Wiring Diagrams ……………...…..…………………..…. 25
7. Electric Specifications ………….…………………….… 28
8. Sound Pressure Level …..………………………………. 29
9. Operation Range …….……………..……………………. 32
III. Hydro Unit
1. Specifications ……..………..…...……….…..…..……… 34
2. Dimensional Drawings ………...………..………………. 36
3. Cycle Diagrams …………………………………………. 37
4. Wiring Diagrams ……………...…..……..………………. 38
5. Electric Specifications ………….……….……………… 40
6. Hydraulic Performance …….…………….……………… 43
IV. Application
Application Examples ……...…………..…..…..……… 45
Mixing Valve…………………...…………..…..…..……… 47
I. Products
1. Nomenclature …….……………………….…….………… 4
2. Line-up ……………………….…………….……….……… 6
3. System Specification……………………………………… 7
EHS Split
I. Products
1. Nomenclature
1-1. Outdoor Unit
Model Name (New)
AE
060
J
X
E
D
E
H
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(1) Classification
AE
EHS
(Buyer)
Single (EHS)
(6) Feature 1
x 1/10 kW (3 digits)
(3) Version
J
EU
(5) Type
E
(2) Capacity
/
2015
(4) Product Type
N
Indoor
X
Outdoor
D
DELUXE (Basic)
(7) Rating Voltage
E
1Φ, 220~240V, 50Hz
G
3Φ, 380~415V, 50Hz
(8) Mode
H
Heat Pump
R410A
4
EHS Split
I. Products
1. Nomenclature
1-2. Indoor Unit
Model Name (New)
AE
090
J
N
Y
D
E
H
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(1) Classification I
AE
EHS
(2) Capacity
x 1/10 kW (3 digits)
/
EU
(Buyer)
(5) Type
Y
Hydro Unit (Wall Mounted)
B
Hydro Unit (Floor Standing)
X
Cylinder Unit
W
Water Tank
(3) Version
J
2015
(6) Feature 1
D
STANDRAD
(4) Product Type
N
Indoor
X
Outdoor
(7) Rating Voltage
E
1Φ, 220~240V, 50Hz
G
3Φ, 380~415V, 50Hz
(8) Mode
H
Heat Pump
R410A
5
EHS Split
I. Products
2. Line-up
2-1. Outdoor Unit
Capacity (kW)
Split Type
Single
Phase
4.0
6.0
9.0
12.0
14.0
16.0
●
●
●
●
●
●
●
●
●
●
3 Phase
2-2. Indoor Unit
Capacity (kW)
Hydro Unit
9.0
16.0
Single
Phase
●
●
3 Phase
●
●
2-3. Combination Table
Outdoor Unit
Hydro Unit
Model Name
Type
AE090JNYDEH/**
AE040JXEDEH/EU
Reversible
●
AE060JXEDEH/EU
Reversible
●
AE090JXEDEH/EU
Reversible
●
AE120JXEDEH/EU
Reversible
●
AE140JXEDEH/EU
Reversible
●
AE160JXEDEH/EU
Reversible
●
AE090JXEDGH/EU
Reversible
AE120JXEDGH/EU
Reversible
●
AE140JXEDGH/EU
Reversible
●
AE160JXEDGH/EU
Reversible
●
AE090JNYDGH/**
AE160JNYDEH/**
AE160JNYDGH/**
●
6
EHS Split
I. Products
3. System Specification
Model
Name
Indoor Unit
AE090JNYDEH/EU
AE090JNYDEH/EU
AE090JNYDEH/EU
Outdoor Unit
AE040JXEDEH/EU
AE060JXEDEH/EU
AE090JXEDEH/EU
-
Heat Pump (A2W)
Heat Pump (A2W)
Heat Pump (A2W)
W
4,400
6,000
9,000
Btu/h
15,000
20,500
30,700
W
5,000
6,500
8,000
Btu/h
17,100
22,200
27,300
860
1,250
2,010
1260
1750
2200
4.1
5.7
9.2
5.7
8.0
10.1
5.10
4.80
4.48
Mode
Heating
Nominal Capacity
Cooling
Performance
(A7/W35) *1
Power Input
(Nominal)
Heating
Current Input
(Nominal)
Heating
Cooling
Cooling
W
A
COP (Nominal Heating)
W/W
EER (Nominal Cooling)
W/W
SCOP
ESEER
System
Performance
(A2/W35) *2
Capacity
Performance
(A-7/W35) *3
Capacity
Field
Wiring
Water
Connections
Heating
COP
Heating
COP
3.71
3.64
4.539
4.577
5.367
5.349
4.789
W
3400
4600
7700
W/W
3.52
3.31
3.38
W
3750
5100
7600
W/W
2.62
2.49
2.45
MCA
A
20
20
22
MFA
A
25
25
27.5
Water Flow Rate (Heating / Cooling)
LPM
13/15
17/20
26/25
Water Pressure (Max)
bar
3
3
3
Inlet
Φ, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
BSPP male 1 1/4"
Outlet
Φ, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
BSPP male 1 1/4"
°C
25~55
25~55
25~55
Water Pipe
Leaving Water
Temperature
Heating
Cooling
Liquid Pipe
Installation
Limitation
°C
5~25
5~25
5~25
Φ, mm
6.35
6.35
6.35
Φ, inch
1/4"
1/4"
1/4"
Φ, mm
15.88
15.88
15.88
Φ, inch
5/8"
5/8"
5/8"
Max. Length
m
30
30
50
Max. Height
m
20
20
30
Gas Pipe
Refrigerant
Connections
Operating
Temp. Range
3.97
4.522
Chargeless Length
m
Heating (A2W) *4
15
15
15
-25~35
-25~35
-25~35
℃
Cooling (A2W)
℃
10~46
10~46
10~46
DHW (A2W) *5
℃
-25~43
-25~43
-25~43
*1) A2W Condition #1 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 7℃DB/6℃WB; (Cooling) Water In/Out 23℃/18℃, Outdoor Air 35℃DB.
*2) A2W Condition #2 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 2℃DB
*3) A2W Condition #3 : (Heating) Water In/Out 30℃/35℃, Outdoor Air -7℃DB
*4) The system is operated in ( -25℃ ≤ Outdoor temp <-20℃) condition, but no guarantee of capacity.
*5) The system is operated by only Booster Heater in special condition( 35℃ < Outdoor temp. ≤ 43℃).
7
EHS Split
I. Products
3. System Specification
Model
Name
Indoor Unit
AE160JNYDEH/EU
AE160JNYDEH/EU
AE160JNYDEH/EU
Outdoor Unit
AE120JXEDEH/EU
AE140JXEDEH/EU
AE160JXEDEH/EU
-
Heat Pump (A2W)
Heat Pump (A2W)
Heat Pump (A2W)
W
12,000
14,000
16,000
Mode
Heating
Nominal Capacity
Cooling
Performance
(A7/W35) *1
Power Input
(Nominal)
Current Input
(Nominal)
Heating
Cooling
Heating
Cooling
Btu/h
40,900
47,800
54,600
W
12,000
14,000
15,000
Btu/h
40,900
47,800
51,200
2,590
3,150
3,760
3100
3800
4140
W
A
COP (Nominal Heating)
W/W
EER (Nominal Cooling)
W/W
SCOP
ESEER
System
Capacity
Heating
11.7
14.3
16.9
14.0
17.0
18.6
4.63
4.44
4.26
3.87
3.68
3.62
4.627
4.560
4.515
4.933
4.906
4.906
W
9800
11200
12500
W/W
3.28
3.25
3.14
W
10,300
11,800
13,400
W/W
2.57
2.55
2.50
Performance
(A2/W35) *2
COP
Performance
(A-7/W35) *3
COP
Field
Wiring
MCA
A
28
30
32
MFA
A
35
37.5
40
Water Flow Rate (Heating / Cooling)
LPM
35/35
40/40
46/44
Water Pressure (Max)
bar
3
3
3
Inlet
Φ, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
BSPP male 1 1/4"
Outlet
Φ, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
BSPP male 1 1/4"
°C
25~55
25~55
25~55
Water
Connections
Capacity
Water Pipe
Leaving Water
Temperature
Heating
Heating
Cooling
Liquid Pipe
Operating
Temp. Range
5~25
5~25
5~25
9.52
9.52
9.52
Φ, inch
3/8"
3/8"
3/8"
Φ, mm
15.88
15.88
15.88
Φ, inch
5/8"
5/8"
5/8"
Max. Length
m
50
50
50
Max. Height
m
30
30
30
Gas Pipe
Refrigerant
Connections
Installation
Limitation
°C
Φ, mm
Chargeless Length
m
Heating (A2W) *4
15
15
15
-25~35
-25~35
-25~35
℃
Cooling (A2W)
℃
10~46
10~46
10~46
DHW (A2W) *5
℃
-25~43
-25~43
-25~43
*1) A2W Condition #1 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 7℃DB/6℃WB; (Cooling) Water In/Out 23℃/18℃, Outdoor Air 35℃DB.
*2) A2W Condition #2 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 2℃DB
*3) A2W Condition #3 : (Heating) Water In/Out 30℃/35℃, Outdoor Air -7℃DB
*4) The system is operated in ( -25℃ ≤ Outdoor temp <-20℃) condition, but no guarantee of capacity.
*5) The system is operated by only Booster Heater in special condition( 35℃ < Outdoor temp. ≤ 43℃).
8
EHS Split
I. Products
3. System Specification
Model
Name
Indoor Unit
AE090JNYDGH/EU
AE160JNYDGH/EU
AE160JNYDGH/EU
Outdoor Unit
AE090JXEDGH/EU
AE120JXEDGH/EU
AE140JXEDGH/EU
-
Heat Pump (A2W)
Heat Pump (A2W)
Heat Pump (A2W)
W
9,000
12,000
14,000
Btu/h
30,700
40,900
47,800
W
7,500
12,000
14,000
Btu/h
25,600
40,900
47,800
2,010
2,590
3,150
2060
3100
3800
3.3
4.1
4.7
3.4
4.7
5.7
4.48
4.63
4.44
Mode
Heating
Nominal Capacity
Cooling
Performance
(A7/W35) *1
Power Input
(Nominal)
Heating
Current Input
(Nominal)
Heating
Cooling
Cooling
W
A
COP (Nominal Heating)
W/W
EER (Nominal Cooling)
W/W
SCOP
ESEER
System
Capacity
Heating
3.64
3.87
3.68
4.569
4.717
4.733
4.648
4.933
4.906
W
7700
9800
11200
W/W
3.38
3.28
3.25
W
7600
10,300
11,800
W/W
2.45
2.57
2.55
Performance
(A2/W35) *2
COP
Performance
(A-7/W35) *3
COP
Field
Wiring
MCA
A
10
10
11
MFA
A
16.1
16.1
16.1
Water Flow Rate (Heating / Cooling)
LPM
26/22
35/35
40/40
Water Pressure (Max)
bar
3
3
3
Inlet
Φ, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
BSPP male 1 1/4"
Outlet
Φ, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
BSPP male 1 1/4"
°C
25~55
25~55
25~55
Water
Connections
Capacity
Water Pipe
Leaving Water
Temperature
Heating
Heating
Cooling
Liquid Pipe
Operating
Temp. Range
5~25
5~25
5~25
6.35
9.52
9.52
Φ, inch
1/4"
3/8"
3/8"
Φ, mm
15.88
15.88
15.88
Φ, inch
5/8"
5/8"
5/8"
Max. Length
m
50
50
50
Max. Height
m
30
30
30
Gas Pipe
Refrigerant
Connections
Installation
Limitation
°C
Φ, mm
Chargeless Length
m
Heating (A2W) *4
15
15
15
-25~35
-25~35
-25~35
℃
Cooling (A2W)
℃
10~46
10~46
10~46
DHW (A2W) *5
℃
-25~43
-25~43
-25~43
*1) A2W Condition #1 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 7℃DB/6℃WB; (Cooling) Water In/Out 23℃/18℃, Outdoor Air 35℃DB.
*2) A2W Condition #2 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 2℃DB
*3) A2W Condition #3 : (Heating) Water In/Out 30℃/35℃, Outdoor Air -7℃DB
*4) The system is operated in ( -25℃ ≤ Outdoor temp <-20℃) condition, but no guarantee of capacity.
*5) The system is operated by only Booster Heater in special condition( 35℃ < Outdoor temp. ≤ 43℃).
9
EHS Split
I. Products
3. System Specification
Model
Name
Indoor Unit
AE160JNYDGH/EU
Outdoor Unit
AE160JXEDGH/EU
Mode
Heating
Nominal Capacity
Cooling
Performance
(A7/W35) *1
Power Input
(Nominal)
Current Input
(Nominal)
Heating
Cooling
Heating
Cooling
-
Heat Pump (A2W)
W
16,000
Btu/h
54,600
W
15,000
Btu/h
51,200
W
A
COP (Nominal Heating)
W/W
EER (Nominal Cooling)
W/W
SCOP
Performance
(A2/W35) *2
Performance
(A-7/W35) *3
System
Field
Wiring
Water
Connections
Heating
COP
6.2
4.26
3.62
W
12500
W/W
3.14
W
13,400
W/W
2.50
MCA
A
12
MFA
A
16.1
Water Flow Rate (Heating / Cooling)
LPM
46/44
Water Pressure (Max)
bar
3
Inlet
Φ, inch
BSPP male 1 1/4"
Outlet
Φ, inch
BSPP male 1 1/4"
°C
25~55
Water Pipe
Leaving Water
Temperature
Heating
Cooling
Liquid Pipe
Installation
Limitation
°C
5~25
Φ, mm
9.52
Φ, inch
3/8"
Φ, mm
15.88
Φ, inch
5/8"
Max. Length
m
50
Max. Height
m
30
Gas Pipe
Refrigerant
Connections
Operating
Temp. Range
5.7
4.906
Heating
COP
Capacity
4140
4.697
ESEER
Capacity
3,760
Chargeless Length
m
Heating (A2W) *4
15
℃
Cooling (A2W)
℃
10~46
DHW (A2W) *5
℃
-25~43
-25~35
*1) A2W Condition #1 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 7℃DB/6℃WB; (Cooling) Water In/Out 23℃/18℃, Outdoor Air 35℃DB.
*2) A2W Condition #2 : (Heating) Water In/Out 30℃/35℃, Outdoor Air 2℃DB
*3) A2W Condition #3 : (Heating) Water In/Out 30℃/35℃, Outdoor Air -7℃DB
*4) The system is operated in ( -25℃ ≤ Outdoor temp <-20℃) condition, but no guarantee of capacity.
*5) The system is operated by only Booster Heater in special condition( 35℃ < Outdoor temp. ≤ 43℃).
10
II. Outdoor Unit
1. Specifications ………………...……..…...….…..………. 12
2. Capacity Tables ………....................……….….………. 16
3. Capacity Correction ……...……………………………… 19
4. Dimensional Drawings ………...………..………………. 20
5. Cycle Diagrams …………………………………………. 23
6. Wiring Diagrams ……………...…..…………………..…. 25
7. Electric Specifications ………….…………………….… 28
8. Sound Pressure Level …..………………………………. 29
9. Operation Range …….……………..……………………. 32
EHS Split
II. Outdoor Unit
1. Specifications
1-1. Outdoor Unit (1Ф)
Model Name
Outdoor Unit
AE040JXEDEH/EU
Condenser
Motor
AE090JXEDEH/EU
Φ, #, V, Hz 220~240V, 50Hz, 1Ф 220~240V, 50Hz, 1Ф 220~240V, 50Hz, 1Ф
Power Supply
Compressor
AE060JXEDEH/EU
Type
-
Model
-
Oil Type
-
POE
POE
POE
Size
-
2RX28S
2RX28S
2RX46S
Type (Model)
-
SIC-67FV-F135-2
SIC-67FV-F135-2
FMDC531SSA
EA
1
1
1
-
DB31-00492A
DB31-00492A
DB31-00579A
CMM
40
43
53
EA
1
1
1
SHF-7H-34U
SHF-7H-34U
SHF-11H
W
X
X
150
Heating
dB(A)
46
47
49
Cooling
dB(A)
46
47
50
Heating
dB(A)
61
61
64
Cooling
dB(A)
63
63
63
Net Weight
kg
48.5
48.5
68.0
Shipping Weight
kg
51.5
51.5
78.0
Net Dimensions (WxHxD)
mm
880 x 638 x 310
880 x 638 x 310
940 x 998 x 330
Shipping Dimensions
(WxHxD)
mm
1,023 x 725 x 413
1,023 x 725 x 413
995 x 1,178 x 426
Quantity
CODE No
Air Flow Rate
Cooling
BLDC Twin Rotary
BLDC Twin Rotary
UG4TH8200FE4SG UG4TH8200FE4SG
BLDC Twin Rotary
UG8TH8265FJW
Fan
Number of Unit
Outdoor
Unit
4-Way Valve
Type (Model)
Base Heater
Power Input
Sound
Pressure
Sound *1
Sound
Power
External
Dimension
Refrigerant
Type
-
R410A
R410A
R410A
Control Method
-
EEV
EEV
EEV
Factory Charging
g
1,400
1,400
1,700
*1) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
2) These products contain R410A which is fluorinated greenhouse gas.
12
EHS Split
II. Outdoor Unit
1. Specifications
1-1. Outdoor Unit (1Ф)
Model Name
Outdoor Unit
AE120JXEDEH/EU
Condenser
Motor
AE160JXEDEH/EU
Φ, #, V, Hz 220~240V, 50Hz, 1Ф 220~240V, 50Hz, 1Ф 220~240V, 50Hz, 1Ф
Power Supply
Compressor
AE140JXEDEH/EU
Type
-
BLDC Twin Rotary
BLDC Twin Rotary
BLDC Twin Rotary
Model
-
UG5T450FUEJX
UG5T450FUEJX
UG5T450FUEJX
Oil Type
-
PVE
PVE
PVE
Size
-
2RX66S
2RX66S
2RX66S
Type (Model)
-
FMDC531SSA
FMDC531SSA
FMDC531SSA
EA
2
2
2
-
DB31-00579A
DB31-00579A
DB31-00579A
CMM
108
108
108
EA
2
2
2
SHF-20D-46
SHF-20D-46
SHF-20D-46
W
150
150
150
Heating
dB(A)
50
50
52
Cooling
dB(A)
50
52
54
Heating
dB(A)
64
64
66
Cooling
dB(A)
64
66
69
Net Weight
kg
100.0
100.0
100.0
Shipping Weight
kg
109.5
109.5
109.5
Net Dimensions (WxHxD)
mm
940 x 1,420 x 330
940 x 1,420 x 330
940 x 1,420 x 330
Shipping Dimensions
(WxHxD)
mm
995 x 1,598 x 426
995 x 1,598 x 426
995 x 1,598 x 426
Quantity
CODE No
Air Flow Rate
Cooling
Fan
Number of Unit
Outdoor
Unit
4-Way Valve
Type (Model)
Base Heater
Power Input
Sound
Pressure
Sound *1
Sound
Power
External
Dimension
Refrigerant
Type
-
R410A
R410A
R410A
Control Method
-
EEV
EEV
EEV
Factory Charging
g
2,980
2,980
2,980
*1) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
2) These products contain R410A which is fluorinated greenhouse gas.
13
EHS Split
II. Outdoor Unit
1. Specifications
1-2. Outdoor Unit (3Ф)
Model Name
Outdoor Unit
AE090JXEDGH/EU
AE120JXEDGH/EU
Φ, #, V, Hz
380~415V, 50Hz, 3Ф
380~415V, 50Hz, 3Ф
Type
-
BLDC Twin Rotary
BLDC Twin Rotary
Model
-
UG8T300FUCJU
UG5T450FUFJX
Oil Type
-
PVE
PVE
Size
-
2RX46S
2RX66S
Type (Model)
-
FMDC531SSA
FMDC531SSA
EA
1
2
-
DB31-00579A
DB31-00579A
CMM
53
108
EA
1
2
SHF-11H
SHF-20D-46
W
150
150
Power Supply
Compressor
Condenser
Motor
Quantity
CODE No
Air Flow Rate
Cooling
Fan
Number of Unit
Outdoor
Unit
4-Way Valve
Type (Model)
Base Heater
Power Input
Sound
Pressure
Heating
dB(A)
49
50
Cooling
dB(A)
50
50
Sound
Power
Heating
dB(A)
64
64
Cooling
dB(A)
63
64
Net Weight
kg
76.0
101.5
Shipping Weight
kg
84.5
111.0
Net Dimensions (WxHxD)
mm
940 x 998 x 330
940 x 1,420 x 330
Shipping Dimensions
(WxHxD)
mm
995 x 1,178 x 426
995 x 1,598 x 426
Sound *
External
Dimension
Refrigerant
Type
-
R410A
R410A
Control Method
-
EEV
EEV
Factory Charging
g
1,900
2,980
*1) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
2) These products contain R410A which is fluorinated greenhouse gas.
14
EHS Split
II. Outdoor Unit
1. Specifications
1-2. Outdoor Unit (3Ф)
Model Name
Outdoor Unit
AE140JXEDGH/EU
AE160JXEDGH/EU
Φ, #, V, Hz
380~415V, 50Hz, 3Ф
380~415V, 50Hz, 3Ф
Type
-
BLDC Twin Rotary
BLDC Twin Rotary
Model
-
UG5T450FUFJX
UG5T450FUFJX
Oil Type
-
PVE
PVE
Size
-
2RX66S
2RX66S
Type (Model)
-
FMDC531SSA
FMDC531SSA
EA
2
2
-
DB31-00579A
DB31-00579A
CMM
108
108
EA
2
2
SHF-20D-46
SHF-20D-46
W
150
150
Power Supply
Compressor
Condenser
Motor
Quantity
CODE No
Air Flow Rate
Cooling
Fan
Number of Unit
Outdoor
Unit
4-Way Valve
Type (Model)
Base Heater
Power Input
Sound
Pressure
Heating
dB(A)
50
52
Cooling
dB(A)
52
54
Sound
Power
Heating
dB(A)
64
66
Cooling
dB(A)
66
69
Net Weight
kg
101.5
101.5
Shipping Weight
kg
111.0
111.0
Net Dimensions (WxHxD)
mm
940 x 1,420 x 330
940 x 1,420 x 330
Shipping Dimensions
(WxHxD)
mm
995 x 1,598 x 426
995 x 1,598 x 426
Sound *1
External
Dimension
Refrigerant
Type
-
R410A
R410A
Control Method
-
EEV
EEV
Factory Charging
g
2,980
2,980
*1) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
2) These products contain R410A which is fluorinated greenhouse gas.
15
EHS Split
II. Outdoor Unit
2. Capacity Tables
2-1. AE040/060/090/120/140/160JXED*H/EU
1) Maximum Heating Capacity (Peak Value)
AE160JXED*H/EU
AE140JXED*H/EU
AE120JXED*H/EU
AE090JXED*H/EU
AE060JXEDEH/EU
AE040JXEDEH/EU
LWT (Leaving Water Temp.), Tamb (Ambient Temp.), HC (Heating Capacity), PI (Power input)
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
25
HC(kW)
3.35
3.65
3.82
3.92
4.18
4.29
4.60
4.73
4.95
5.17
30
PI(kW)
1.02
1.02
1.00
0.99
0.86
0.71
0.52
0.53
0.55
0.57
HC(kW)
3.39
3.69
3.93
4.07
4.32
4.41
4.50
4.64
4.89
5.13
PI(kW)
1.74
1.74
1.71
1.69
1.49
1.24
0.95
0.97
1.00
1.04
HC(kW)
4.74
5.15
5.49
5.70
6.02
6.11
6.30
6.50
6.85
7.19
PI(kW)
2.76
2.76
2.71
2.69
2.49
2.24
1.52
1.59
1.71
1.83
HC(kW)
6.99
7.66
8.22
8.55
9.61
10.41
9.20
9.74
10.64
11.53
PI(kW)
3.38
3.38
3.33
3.30
3.02
2.68
1.95
1.97
2.00
2.03
HC(kW)
9.55
10.45
11.17
11.61
12.55
13.06
12.25
12.81
13.75
14.69
PI(kW)
4.07
4.07
4.01
3.97
3.64
3.23
2.55
2.57
2.61
2.64
HC(kW)
11.02
12.05
12.92
13.43
14.51
15.09
14.50
15.19
16.35
17.50
PI(kW)
4.73
4.73
4.64
4.59
4.22
3.74
2.98
3.00
3.03
3.07
HC(kW)
12.42
13.60
14.58
15.18
16.23
16.71
16.35
17.24
18.73
20.21
25
HC(kW)
4.82
5.22
5.49
5.64
5.99
6.10
6.60
6.79
7.12
7.44
PI(kW)
3.10
3.10
3.05
3.02
2.77
2.47
1.77
1.84
1.95
2.07
HC(kW)
6.83
7.51
9.33
8.59
9.56
10.27
9.00
9.54
10.44
11.34
PI(kW)
3.91
3.91
3.85
3.81
3.50
3.11
2.27
2.29
2.32
2.35
HC(kW)
9.26
10.17
11.25
11.64
12.56
13.07
12.00
12.58
13.54
14.50
PI(kW)
4.60
4.60
4.53
4.48
4.11
3.65
2.85
2.87
2.91
2.94
HC(kW)
10.58
11.64
12.60
13.34
14.37
14.93
14.00
14.69
15.85
17.00
PI(kW)
5.34
5.34
5.25
5.19
4.76
4.22
3.37
3.39
3.42
3.46
HC(kW)
12.03
13.23
14.40
15.15
16.18
16.67
16.00
16.90
18.40
19.90
40
PI(kW)
1.59
1.59
1.56
1.55
1.36
1.14
0.86
0.87
0.90
0.92
HC(kW)
3.48
3.80
4.19
4.42
4.63
4.67
4.30
4.47
4.75
5.04
PI(kW)
2.27
2.27
2.24
2.21
1.95
1.64
1.25
1.27
1.30
1.34
HC(kW)
4.59
5.02
5.54
5.84
6.11
6.16
5.70
5.92
6.30
6.67
PI(kW)
3.44
3.44
3.39
3.35
3.05
2.69
2.01
2.08
2.20
2.32
HC(kW)
6.66
7.36
8.16
8.65
9.52
10.13
8.80
9.34
10.24
11.15
PI(kW)
4.45
4.45
4.37
4.33
3.97
3.53
2.59
2.61
2.64
2.68
HC(kW)
8.96
9.90
11.02
11.70
12.59
13.09
11.75
12.34
13.32
14.30
PI(kW)
5.13
5.13
5.05
5.00
4.58
4.07
3.15
3.17
3.21
3.24
HC(kW)
10.15
11.23
12.50
13.26
14.25
14.78
13.50
14.19
15.35
16.50
PI(kW)
5.95
5.95
5.85
5.79
5.30
4.71
3.76
3.78
3.82
3.85
HC(kW)
11.63
12.86
14.28
15.14
16.15
16.64
15.65
16.56
18.07
19.59
35
PI(kW)
HC(kW)
PI(kW)
3.86
4.33
4.62
4.80
4.82
4.20
4.38
4.69
4.99
2.18
2.14
2.12
1.88
1.59
1.20
1.22
1.24
1.27
4.50
4.83
4.99
4.98
4.10
4.30
4.62
4.95
2.44
2.41
2.14
1.81
1.37
1.39
1.42
1.44
PI(kW)
2.54
2.54
2.50
2.48
2.19
1.85
1.40
1.42
1.45
1.49
HC(kW)
PI(kW)
HC(kW)
PI(kW)
4.97
5.57
5.94
6.17
6.19
5.40
5.64
6.03
6.42
2.81
2.77
2.74
2.42
2.05
1.55
1.57
1.61
1.64
5.62
6.05
6.25
6.24
5.10
5.35
5.75
6.16
3.04
3.01
2.66
2.26
1.70
1.72
1.76
1.79
PI(kW)
3.78
3.78
3.72
3.68
3.34
2.92
2.26
2.33
2.45
2.56
HC(kW)
PI(kW)
HC(kW)
PI(kW)
7.21
8.15
8.72
9.49
10.01
8.60
9.14
10.05
10.95
4.13
4.06
4.02
3.62
3.15
2.50
2.57
2.69
2.81
8.16
8.81
9.48
9.89
8.40
8.94
9.85
10.76
4.40
4.35
3.90
3.37
2.75
2.82
2.94
3.06
PI(kW)
4.99
4.99
4.90
4.85
4.45
3.96
2.91
2.93
2.96
3.00
HC(kW)
PI(kW)
HC(kW)
PI(kW)
9.63
10.97
11.77
12.64
13.13
11.50
12.10
13.10
14.10
5.53
5.44
5.38
4.93
4.39
3.23
3.25
3.29
3.32
10.93
11.87
12.71
13.18
11.25
11.86
12.88
13.90
5.97
5.91
5.42
4.83
3.55
3.57
3.61
3.64
PI(kW)
5.66
5.66
5.57
5.52
5.06
4.50
3.45
3.47
3.51
3.54
HC(kW)
PI(kW)
HC(kW)
PI(kW)
10.82
12.31
13.20
14.14
14.64
13.00
13.69
14.85
16.00
6.20
6.10
6.04
5.53
4.92
3.75
3.77
3.81
3.84
12.13
13.16
14.04
14.52
12.50
13.19
14.35
15.50
6.62
6.56
6.01
5.35
4.05
4.07
4.11
4.14
PI(kW)
6.57
6.57
6.46
6.39
5.85
5.19
4.15
4.17
4.21
4.24
HC(kW)
PI(kW)
HC(kW)
PI(kW)
12.49
14.16
15.15
16.14
16.63
15.30
16.22
17.75
19.28
7.18
7.07
7.00
6.40
5.68
4.54
4.56
4.60
4.63
14.05
15.20
16.16
16.64
14.95
15.88
17.42
18.97
7.40
7.61
6.95
6.16
4.93
4.95
4.99
5.02
45
50
45
40
35
50
45
40
35
50
HC(kW)
40
35
30
45
PI(kW)
1.88
1.88
1.85
1.83
1.62
1.36
1.03
1.05
1.07
1.10
40
35
30
25
HC(kW)
12.82
13.97
14.75
15.23
16.30
16.77
16.70
17.58
19.05
20.52
HC(kW)
4.66
5.09
5.51
5.77
6.06
6.13
6.00
6.21
6.57
6.93
30
25
HC(kW)
11.44
12.46
13.14
13.54
14.66
15.26
15.00
15.69
16.85
18.00
PI(kW)
2.00
2.00
1.97
1.95
1.72
1.44
1.10
1.12
1.15
1.19
30
25
HC(kW)
9.84
10.73
11.27
11.59
12.55
13.06
12.50
13.05
13.97
14.89
HC(kW)
3.43
3.74
5.51
4.24
4.47
4.53
4.40
4.56
4.82
5.08
30
25
HC(kW)
7.16
7.81
8.26
8.52
9.67
10.55
9.40
9.94
10.83
11.73
35
PI(kW)
1.30
1.30
1.28
1.27
1.11
0.92
0.69
0.70
0.72
0.75
50
45
40
50
45
50
55
HC(kW) PI(kW)
4.68
5.08
5.20
5.15
4.00
4.21
4.56
4.90
2.74
2.71
2.40
2.04
1.54
1.56
1.59
1.62
55
HC(kW) PI(kW)
5.69
6.17
6.33
6.29
4.80
5.06
5.48
5.91
3.31
3.27
2.90
2.46
1.85
1.87
1.91
1.94
55
HC(kW) PI(kW)
8.18
8.93
9.48
9.78
8.20
8.75
9.66
10.57
5.10
5.10
4.18
3.60
2.99
3.06
3.18
3.30
55
HC(kW) PI(kW)
10.92
12.01
12.81
13.26
11.00
11.62
12.66
13.70
6.48
6.44
5.90
5.26
3.87
3.89
3.93
3.96
55
HC(kW) PI(kW)
11.96
13.14
13.97
14.41
12.00
12.69
13.85
15.00
6.94
6.94
6.48
5.78
4.35
4.37
4.41
4.44
55
HC(kW) PI(kW)
13.96
15.28
16.20
16.68
14.60
15.54
17.10
18.66
7.40
7.40
7.50
6.65
5.32
5.34
5.38
5.41
1. Heating capacity : Capacity is according to Eurovent rating standard OM-3-2015 and valid for heated water range △t = 3∼8°C
2. Cooling capacity : Capacity is according to Eurovent rating standard OM-3-2015 and valid for chilled water range △t = 3∼8°C
3. Power input : Power input is according to Eurovent rating standard OM-3-2015.
4. Peak value : Tested without defrost operation in accordance with EN14511
※ The real capacity would be changed according to the install environment.
16
EHS Split
II. Outdoor Unit
2. Capacity Tables
2-1. AE040/060/090/120/140/160JXED*H/EU
2) Maximum Heating Capacity (Integrated Value)
AE160JXED*H/EU
AE140JXED*H/EU
AE120JXED*H/EU
AE090JXED*H/EU
AE060JXEDEH/EU
AE040JXEDEH/EU
LWT (Leaving Water Temp.), Tamb (Ambient Temp.), HC (Heating Capacity), PI (Power input)
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
LWT (℃)
Tamb (℃)
-20
-15
-10
-7
-2
2
7
10
15
20
25
HC(kW)
3.09
3.37
3.52
3.62
3.47
3.31
4.60
4.73
4.95
5.17
30
PI(kW)
0.98
0.98
0.96
0.96
0.79
0.62
0.52
0.53
0.55
0.57
HC(kW)
3.06
3.34
3.55
3.68
3.52
3.36
4.50
4.64
4.89
5.13
PI(kW)
1.68
1.68
1.65
1.63
1.36
1.08
0.95
0.97
1.00
1.04
HC(kW)
4.29
4.66
4.97
5.15
4.91
4.66
6.30
6.50
6.85
7.19
PI(kW)
2.66
2.66
2.62
2.59
2.27
1.95
1.52
1.59
1.71
1.83
HC(kW)
6.33
6.93
7.43
7.73
7.83
7.93
9.20
9.74
10.64
11.53
PI(kW)
3.26
3.26
3.21
3.18
2.76
2.34
1.95
1.97
2.00
2.03
HC(kW)
8.64
9.45
10.11
10.50
10.23
9.95
12.25
12.81
13.75
14.69
PI(kW)
3.93
3.93
3.87
3.83
3.32
2.81
2.55
2.57
2.61
2.64
HC(kW)
9.96
10.90
11.68
12.15
11.83
11.50
14.50
15.19
16.35
17.50
PI(kW)
4.56
4.56
4.48
4.43
3.84
3.26
2.98
3.00
3.03
3.07
HC(kW)
11.23
12.30
13.19
13.73
13.23
12.73
16.35
17.24
18.73
20.21
25
HC(kW)
4.45
4.82
5.06
5.21
4.96
4.72
6.60
6.79
7.12
7.44
PI(kW)
2.92
2.92
2.88
2.85
2.48
2.11
1.77
1.84
1.95
2.07
HC(kW)
6.04
6.64
7.24
7.60
7.65
7.70
9.00
9.54
10.44
11.34
PI(kW)
3.69
3.69
3.63
3.59
3.13
2.66
2.27
2.29
2.32
2.35
HC(kW)
8.19
9.00
9.81
10.30
10.05
9.80
12.00
12.58
13.54
14.50
PI(kW)
4.34
4.34
4.27
4.23
3.68
3.13
2.85
2.87
2.91
2.94
HC(kW)
9.36
10.30
11.24
11.80
11.50
11.20
14.00
14.69
15.85
17.00
PI(kW)
5.04
5.04
4.95
4.89
4.26
3.62
3.37
3.39
3.42
3.46
HC(kW)
10.64
11.70
12.76
13.40
12.95
12.50
16.00
16.90
18.40
19.90
40
PI(kW)
1.47
1.47
1.45
1.43
1.20
0.97
0.86
0.87
0.90
0.92
HC(kW)
3.00
3.28
3.61
3.82
3.63
3.44
4.30
4.47
4.75
5.04
PI(kW)
2.10
2.10
2.07
2.05
1.72
1.39
1.25
1.27
1.30
1.34
HC(kW)
3.96
4.34
4.78
5.05
4.79
4.54
5.70
5.92
6.30
6.67
PI(kW)
3.18
3.18
3.13
3.10
2.69
2.28
2.01
2.08
2.20
2.32
HC(kW)
5.75
6.35
7.05
7.47
7.47
7.47
8.80
9.34
10.24
11.15
PI(kW)
4.12
4.12
4.05
4.01
3.50
2.99
2.59
2.61
2.64
2.68
HC(kW)
7.74
8.55
9.52
10.10
9.88
9.65
11.75
12.34
13.32
14.30
PI(kW)
4.75
4.75
4.67
4.63
4.04
3.45
3.15
3.17
3.21
3.24
HC(kW)
8.76
9.70
10.79
11.45
11.18
10.90
13.50
14.19
15.35
16.50
PI(kW)
5.51
5.51
5.42
5.36
4.67
3.98
3.76
3.78
3.82
3.85
HC(kW)
10.04
11.10
12.33
13.07
12.67
12.27
15.65
16.56
18.07
19.59
35
PI(kW)
HC(kW)
PI(kW)
3.25
3.65
3.88
3.68
3.49
4.20
4.38
4.69
4.99
1.96
1.93
1.91
1.61
1.32
1.20
1.22
1.24
1.27
3.68
3.95
3.74
3.53
4.10
4.30
4.62
4.95
2.17
2.15
1.82
1.49
1.37
1.39
1.42
1.44
PI(kW)
2.32
2.32
2.28
2.26
1.90
1.54
1.40
1.42
1.45
1.49
HC(kW)
PI(kW)
HC(kW)
PI(kW)
4.18
4.69
4.99
4.74
4.48
5.40
5.64
6.03
6.42
2.53
2.49
2.46
2.08
1.70
1.55
1.57
1.61
1.64
4.59
4.94
4.68
4.42
5.10
5.35
5.75
6.16
2.70
2.67
2.26
1.86
1.70
1.72
1.76
1.79
PI(kW)
3.45
3.45
3.39
3.36
2.90
2.44
2.26
2.33
2.45
2.56
HC(kW)
PI(kW)
HC(kW)
PI(kW)
6.07
6.86
7.33
7.29
7.24
8.60
9.14
10.05
10.95
3.71
3.65
3.61
3.11
2.61
2.50
2.57
2.69
2.81
6.67
7.20
7.11
7.01
8.40
8.94
9.85
10.76
3.91
3.87
3.32
2.77
2.75
2.82
2.94
3.06
PI(kW)
4.54
4.54
4.47
4.42
3.87
3.31
2.91
2.93
2.96
3.00
HC(kW)
PI(kW)
HC(kW)
PI(kW)
8.10
9.23
9.90
9.70
9.50
11.50
12.10
13.10
14.10
4.97
4.89
4.84
4.24
3.64
3.23
3.25
3.29
3.32
8.93
9.70
9.53
9.35
11.25
11.86
12.88
13.90
5.31
5.25
4.61
3.97
3.55
3.57
3.61
3.64
PI(kW)
5.16
5.16
5.08
5.03
4.40
3.76
3.45
3.47
3.51
3.54
HC(kW)
PI(kW)
HC(kW)
PI(kW)
9.10
10.35
11.10
10.85
10.60
13.00
13.69
14.85
16.00
5.57
5.48
5.43
4.75
4.08
3.75
3.77
3.81
3.84
9.91
10.75
10.53
10.30
12.50
13.19
14.35
15.50
5.88
5.83
5.11
4.40
4.05
4.07
4.11
4.14
PI(kW)
5.98
5.98
5.89
5.83
5.08
4.34
4.15
4.17
4.21
4.24
HC(kW)
PI(kW)
HC(kW)
PI(kW)
10.51
11.91
12.74
12.39
12.04
15.30
16.22
17.75
19.28
6.46
6.35
6.29
5.50
4.70
4.54
4.56
4.60
4.63
11.48
12.42
12.11
11.80
14.95
15.88
17.42
18.97
6.82
6.76
5.91
5.06
4.93
4.95
4.99
5.02
45
50
45
40
35
50
45
40
35
50
HC(kW)
40
35
30
45
PI(kW)
1.71
1.71
1.69
1.67
1.41
1.14
1.03
1.05
1.07
1.10
40
35
30
25
HC(kW)
11.83
12.89
13.62
14.06
13.51
12.96
16.70
17.58
19.05
20.52
HC(kW)
4.13
4.50
4.88
5.10
4.85
4.60
6.00
6.21
6.57
6.93
30
25
HC(kW)
10.56
11.50
12.13
12.50
12.15
11.80
15.00
15.69
16.85
18.00
PI(kW)
1.89
1.89
1.86
1.84
1.54
1.23
1.10
1.12
1.15
1.19
30
25
HC(kW)
9.09
9.90
10.40
10.70
10.40
10.10
12.50
13.05
13.97
14.89
HC(kW)
3.03
3.31
3.58
3.75
3.58
3.40
4.40
4.56
4.82
5.08
30
25
HC(kW)
6.61
7.21
7.62
7.87
8.01
8.16
9.40
9.94
10.83
11.73
35
PI(kW)
1.22
1.22
1.21
1.19
0.99
0.79
0.69
0.70
0.72
0.75
50
45
40
50
45
50
55
HC(kW) PI(kW)
3.71
4.02
3.79
3.57
4.00
4.21
4.56
4.90
2.41
2.38
2.02
1.67
1.54
1.56
1.59
1.62
55
HC(kW) PI(kW)
4.50
4.88
4.63
4.37
4.80
5.06
5.48
5.91
2.91
2.88
2.44
2.01
1.85
1.87
1.91
1.94
55
HC(kW) PI(kW)
6.48
7.07
6.92
6.78
8.20
8.75
9.66
10.57
4.16
4.12
3.53
2.94
2.99
3.06
3.18
3.30
55
HC(kW) PI(kW)
8.64
9.50
9.35
9.20
11.00
11.62
12.66
13.70
5.73
5.67
4.98
4.29
3.87
3.89
3.93
3.96
55
HC(kW) PI(kW)
9.46
10.40
10.20
10.00
12.00
12.69
13.85
15.00
6.29
6.23
5.47
4.71
4.35
4.37
4.41
4.44
55
HC(kW) PI(kW)
11.05
12.09
11.83
11.57
14.60
15.54
17.10
18.66
7.29
7.22
6.33
5.43
5.32
5.34
5.38
5.41
1. Heating capacity : Capacity is according to Eurovent rating standard OM-3-2015 and valid for heated water range △t = 3∼8°C
2. Cooling capacity : Capacity is according to Eurovent rating standard OM-3-2015 and valid for chilled water range △t = 3∼8°C
3. Power input : Power input is according to Eurovent rating standard OM-3-2015.
4. Integrated value : Tested with defrost operation in accordance with EN14511
※ The real capacity would be changed according to the install environment.
17
EHS Split
II. Outdoor Unit
2. Capacity Tables
2-1. AE040/060/090/120/140/160JXED*H/EU
3) Maximum Cooling Capacity
LWT (Leaving Water Temp.), Tamb (Ambient Temp.), CC (Cooling Capacity), PI (Power input)
AE040JXEDEH/EU
LWT (℃)
Tamb (℃)
7
HC(kW)
AE060JXEDEH/EU
AE090JXED*H/EU
PI(kW)
HC(kW)
PI(kW)
HC(kW)
18
PI(kW)
HC(kW)
26
PI(kW)
HC(kW)
PI(kW)
4.42
0.92
4.80
0.94
5.18
0.96
5.43
0.97
5.82
0.98
6.71
1.02
4.09
1.03
4.47
1.05
4.85
1.07
5.11
1.08
5.49
1.09
6.38
1.13
30
3.76
1.14
4.14
1.16
4.53
1.18
4.78
1.19
5.16
1.20
6.05
1.24
35
3.60
1.20
3.98
1.22
4.36
1.23
4.62
1.24
5.00
1.26
5.89
1.30
46
3.24
1.32
3.62
1.34
4.00
1.35
4.26
1.37
4.64
1.38
5.53
1.42
7
10
13
15
18
26
Tamb (℃)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
10
5.76
1.35
6.26
1.35
6.75
1.35
7.07
1.35
7.56
1.35
8.71
1.35
20
5.34
1.51
5.83
1.51
6.32
1.51
6.65
1.51
7.14
1.51
8.28
1.51
30
4.91
1.67
5.40
1.67
5.89
1.67
6.22
1.67
6.71
1.67
7.86
1.67
35
4.70
1.75
5.19
1.75
5.68
1.75
6.01
1.75
6.50
1.75
7.65
1.75
46
4.23
1.93
4.72
1.93
5.21
1.93
5.54
1.93
6.03
1.93
7.18
1.93
7
10
13
15
18
25
Tamb (℃)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
10
8.41
1.36
9.01
1.37
9.61
1.38
10.01
1.39
10.61
1.41
12.01
1.44
20
7.37
1.67
7.97
1.69
8.57
1.70
8.97
1.71
9.57
1.72
10.97
1.76
30
6.32
1.99
6.92
2.00
7.52
2.02
7.92
2.03
8.52
2.04
9.92
2.07
35
5.80
2.15
6.40
2.16
7.00
2.18
7.40
2.19
8.00
2.20
9.40
2.23
46
4.65
2.50
5.25
2.51
5.85
2.53
6.25
2.54
6.85
2.55
8.25
2.58
LWT (℃)
AE120JXED*H/EU
HC(kW)
15
10
LWT (℃)
7
10
13
15
18
25
Tamb (℃)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
10
11.95
1.90
12.77
1.90
13.58
1.90
14.13
1.90
14.95
1.90
16.86
1.90
20
10.77
2.38
11.59
2.38
12.40
2.38
12.95
2.38
13.77
2.38
15.68
2.38
30
9.59
2.86
10.41
2.86
11.23
2.86
11.77
2.86
12.59
2.86
14.50
2.86
35
9.00
3.10
9.82
3.10
10.64
3.10
11.18
3.10
12.00
3.10
13.91
3.10
46
7.70
3.63
8.52
3.63
9.34
3.63
9.89
3.63
10.70
3.63
12.61
3.63
LWT (℃)
AE140JXED*H/EU
PI(kW)
13
20
LWT (℃)
7
10
13
15
18
25
Tamb (℃)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
10
14.09
2.39
15.04
2.40
15.99
2.42
16.63
2.43
17.59
2.44
19.81
2.47
20
12.65
2.93
13.61
2.95
14.56
2.96
15.20
2.97
16.15
2.98
18.38
3.02
30
11.22
3.48
12.17
3.49
13.13
3.51
13.76
3.51
14.72
3.53
16.94
3.56
35
10.50
3.75
11.45
3.76
12.41
3.78
13.05
3.79
14.00
3.80
16.23
3.83
46
8.92
4.35
9.88
4.36
10.83
4.38
11.47
4.38
12.42
4.40
14.65
4.43
LWT (℃)
AE160JXED*H/EU
10
7
10
13
15
18
25
Tamb (℃)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
HC(kW)
PI(kW)
10
14.74
2.73
15.77
2.77
16.81
2.81
17.50
2.84
18.54
2.87
20.96
2.96
20
13.32
3.24
14.36
3.28
15.39
3.32
16.09
3.34
17.12
3.38
19.54
3.47
30
11.91
3.75
12.94
3.79
13.98
3.82
14.67
3.85
15.71
3.89
18.13
3.98
35
11.20
4.00
12.24
4.04
13.27
4.08
13.96
4.10
15.00
4.14
17.42
4.23
46
9.64
4.56
10.68
4.59
11.72
4.63
12.41
4.66
13.44
4.70
15.86
4.79
1. Heating capacity is according to Eurovent rating standard OM-3-2015 and valid for heated water range △t = 3∼8°C
2. Cooling capacity is according to Eurovent rating standard OM-3-2015 and valid for chilled water range △t = 3∼8°C
3. Power input is total of indoor and outdoor unit, according to Eurovent rating standard OM-3-2015.
※ The real capacity would be changed according to the install environment.
18
EHS Split
II. Outdoor Unit
3. Capacity Correction
3-1. AE040/060JXEDEH/EU
1) Heating
2) Cooling
O
D
U
O
D
U
IDU
IDU
IDU
IDU
O
D
U
O
D
U
3-2. AE090/120/140/160JXED*H/EU
1) Heating
O
D
U
O
D
U
2) Cooling
O
D
U
IDU
IDU
IDU
IDU
O
D
U
19
EHS Split
II. Outdoor Unit
4. Dimensional Drawings
4-1. Outdoor Unit
1) AE040/060JXEDEH/EU
No.
Table of Descriptions
①
Gas Ref. Pipe
②
Liquid Ref. Pipe
③
Power & Communication Wiring Conduits
(Unit : mm)
20
EHS Split
II. Outdoor Unit
4. Dimensional Drawings
4-1. Outdoor Unit
2) AE090JXED*H/EU
(Unit : mm)
No.
Table of Descriptions
①
Gas Ref. Pipe
②
Liquid Ref. Pipe
③
Drain Hole
④
Power & Communication Wiring Conduits
21
EHS Split
II. Outdoor Unit
4. Dimensional Drawings
4-1. Outdoor Unit
3) AE120/140/160JXED*H/EU
No.
Table of Descriptions
①
Gas Ref. Pipe
②
Liquid Ref. Pipe
③
Drain Hole
④
Power & Communication Wiring Conduits
(Unit : mm)
22
EHS Split
II. Outdoor Unit
5. Cycle Diagrams
5-1. Outdoor Unit
1) AE040/060JXEDEH/EU
2) AE090JXED*H/EU
Charge Port
23
EHS Split
II. Outdoor Unit
5. Cycle Diagrams
5-1. Outdoor Unit
3) AE120/140/160JXED*H/EU
Charge Port
24
EHS Split
II. Outdoor Unit
6. Wiring Diagrams
6-1. Outdoor Unit
1) AE040/060JXEDEH/EU
25
EHS Split
II. Outdoor Unit
6. Wiring Diagrams
6-1. Outdoor Unit
2) AE090/120/140/160JXEDEH/EU
26
EHS Split
II. Outdoor Unit
6. Wiring Diagrams
6-1. Outdoor Unit
3) AE090/120/140/160JXEDGH/EU
27
EHS Split
II. Outdoor Unit
7. Electric Specifications
7-1. Outdoor Unit
1) Power Supply (Single Phase)
Rated
Voltage Range
Outdoor Unit
MCA (A)
MFA (A)
264
20
25.0
198
264
20
25.0
220-240
198
264
22
27.5
50
220-240
198
264
28
35.0
AE140JXEDEH/EU
50
220-240
198
264
30
37.5
AE160JXEDEH/EU
50
220-240
198
264
32
40.0
MCA
MFA
Hz
Volts
Min.
Max.
AE040JXEDEH/EU
50
220-240
198
AE060JXEDEH/EU
50
220-240
AE090JXEDEH/EU
50
AE120JXEDEH/EU
2) Power Supply (3 Phase)
Rated
Voltage Range
Outdoor Unit
Hz
Volts
Min.
Max.
AE090JXEDGH/EU
50
380-415
342
457
10
16.1
AE120JXEDGH/EU
50
380-415
342
457
10
16.1
AE140JXEDGH/EU
50
380-415
342
457
11
16.1
AE160JXEDGH/EU
50
380-415
342
457
12
16.1
Note
 Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord.
(Code designation IEC : 60245 IEC 66 / CENELEC:H07RN-F)
 Select power supply cord based on MCA.
 MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
 MCA represents maximum input current.
 MFA represents capacity which may accept MCA.
 Communication cable specification : 0.75~1.5㎟, 2wires
※ Abbreviations
- MCA : Minimum Circuit Amps.(A)
- MFA : Maximum Fuse Amps.(A)
28
EHS Split
II. Outdoor Unit
8. Sound Pressure Level
8-1. Operation Sound Level
Unit (dB(A))
Model
Heating
Cooling
AE040JXEDEH/EU
46
46
AE060JXEDEH/EU
47
47
Note
 These operation sound value were obtained in an anechoic room. Sound pressure level will vary depending on a range of
factors such as the construction of the particular room where the equipment is installed.
 Operation sound level may differ depending on operation and ambient conditions.
8-2. NC Curve
1) AE040JXEDEH/EU
2) AE060JXEDEH/EU
29
EHS Split
II. Outdoor Unit
8. Sound Pressure Level
8-3. Operation Sound Level
Unit (dB(A))
Model
Heating
Cooling
AE090JXEDEH/EU
49
50
AE120JXEDEH/EU
50
50
AE140JXEDEH/EU
50
52
AE160JXEDEH/EU
52
54
Note
 These operation sound value were obtained in an anechoic room. Sound pressure level will vary depending on a range of
factors such as the construction of the particular room where the equipment is installed.
 Operation sound level may differ depending on operation and ambient conditions.
8-4. NC Curve
1) AE090JXEDEH/EU
2) AE120JXEDEH/EU
3) AE140JXEDEH/EU
4) AE160JXEDEH/EU
30
EHS Split
II. Outdoor Unit
8. Sound Pressure Level
8-5. Operation Sound Level
Unit (dB(A))
Model
Heating
Cooling
AE090JXEDGH/EU
49
50
AE120JXEDGH/EU
50
50
AE140JXEDGH/EU
50
52
AE160JXEDGH/EU
52
54
Note
 These operation sound value were obtained in an anechoic room. Sound pressure level will vary depending on a range of
factors such as the construction of the particular room where the equipment is installed.
 Operation sound level may differ depending on operation and ambient conditions.
8-6. NC Curve
1) AE090JXEDGH/EU
2) AE120JXEDGH/EU
3) AE140JXEDGH/EU
4) AE160JXEDGH/EU
31
EHS Split
II. Outdoor Unit
9. Operation Range
9-1. Outdoor Unit
1) Cooling
2) Heating
35
Outdoor temp. (℃, DB)
Outdoor temp. (℃, DB)
46
10
24
-10
-20
-25
5
25
Leaving water temp. (℃)
MONO Outdoor Unit
Controller
Cooling
Heating
15 20 25 37 43 55
Leaving water temp. (℃)
Water Temp. (℃)
Water Flow Rates (LPM)
Min
Std
Max
Cooling
5
-
25
Heating
15
-
55
Inlet
-
23 (12*2)
30
Outlet
5
18 (7*2)
25
Inlet
5
30 (40*2)
-
Outlet
25
(15*4)
35
Backup heater operation
& No guarantee of capacity
(45*2)
Min
12 (7*1)
Std
Δ 5℃
55
Max
Air Temp. (℃, DB/WB)
Min
Std
Max
10/-
35/24
46/28
-25/-
7/6
(-7/-8*3)
35/24
58 (48*1)
*1) Model : AE040JXEDEH/AE090JNYDEH
AE060JXEDEH/AE090JNYDEH
AE090JXEDEH/AE090JNYDEH
AE090JXEDGH/AE090JNYDEH
*2) Eurovent Test Condition #2
*3) NF PAC Low Temp. Heating Condition.
*4) Back up heater operation.
Operation of outdoor unit possible, but no guarantee of capacity in this condition. ( -25℃ ≤ Outdoor temp <-20℃)
※
3) DHW (Domestic Hot Water Tank)
43
35
Outdoor Temp. (℃DB)
Booster heater
operation only
--25
Leaving water temp. (℃)
※ Special condition( 35℃ < Outdoor temp. ≤ 43℃) is operated by only Booster Heater.
SAMSUNG doesn’t supply DHW for EHS Split.
Since it is a reference data, you have to check DHW operation range for yours.
32
III. Hydro Unit
1. Specifications ……..………..…...……….…..…..……… 34
2. Dimensional Drawings ………...………..………………. 36
3. Cycle Diagrams …………………………………………. 37
4. Wiring Diagrams ……………...…..……..………………. 38
5. Electric Specifications ………….……….……………… 40
6. Hydraulic Performance …….…………….……………… 43
EHS Split
III. Hydro Unit
1. Specifications
1-1. Hydro Unit (1Ф)
Model Name
Indoor Unit
AE090JNYDEH/EU
AE160JNYDEH/EU
Φ, #, V, Hz
220~240V, 50Hz, 1Ф
220~240V, 50Hz, 1Ф
-
Centrifurugal
(UPM3 25-7.5)
Centrifurugal
(Stratos 25 1-9)
Motor Input
W
60
90
Number of Unit
EA
1
1
-
Magnetic, Decreasing
Magnetic, Decreasing
LPM
7 ± 1.5
12 ± 1.5
W
4,000
6,000
Liter
8
8
bar
2.9
2.9
Air Purge Valve
Ф, inch
BSPP male 3/8"
BSPP male 3/8"
Service Valve
Ф, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
Heating Std
dB(A)
26
33
Cooling Std
dB(A)
26
33
Heating Std
dB(A)
40
47
Net Weight
kg
45.0
45.0
Shipping Weight
kg
55.0
55.0
Net Dimensions (WxHxD)
mm
510 x 850 x 315
510 x 850 x 315
Shipping Dimensions
(WxHxD)
mm
564 x 1,024 x 426
564 x 1,024 x 426
Back up Boiler
-
230VAC 0.5A(DO)
230VAC 0.5A(DO)
Room Thermostat
-
230VAC 10mA(DI)
230VAC 10mA(DI)
Solar Pump
-
230VAC 10mA(DI)
230VAC 10mA(DI)
Valves, 2 or 3way
-
230VAC 0.5A(DO)
230VAC 0.5A(DO)
Power Supply
Type (Model Name)
Water
Pump
Type (Model Name)
Flow Switch
Min. flow rates
Electric Heater
Expansion Vessel
Pressure Relief Valve
Hydro Unit
Sound
Pressure
Sound *1
Sound
Power
External
Dimension
External
Control
*1) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
34
EHS Split
III. Hydro Unit
1. Specifications
1-2. Hydro Unit (3Ф)
Model Name
Indoor Unit
AE090JNYDGH/EU
AE160JNYDGH/EU
Φ, #, V, Hz
380~4150V, 50Hz, 3Ф
380~4150V, 50Hz, 3Ф
-
Centrifurugal
(UPM3 25-7.5)
Centrifurugal
(Stratos 25 1-9)
Motor Input
W
60
90
Number of Unit
EA
1
1
-
Magnetic, Decreasing
Magnetic, Decreasing
LPM
7 ± 1.5
12 ± 1.5
W
6,000
6,000
Liter
8
8
bar
2.9
2.9
Air Purge Valve
Ф, inch
BSPP male 3/8"
BSPP male 3/8"
Service Valve
Ф, inch
BSPP male 1 1/4"
BSPP male 1 1/4"
Heating Std
dB(A)
26
33
Cooling Std
dB(A)
26
33
Heating Std
dB(A)
40
47
Net Weight
kg
46.5
46.5
Shipping Weight
kg
56.0
56.0
Net Dimensions (WxHxD)
mm
510 x 850 x 315
510 x 850 x 315
Shipping Dimensions
(WxHxD)
mm
564 x 1,024 x 426
564 x 1,024 x 426
Back up Boiler
-
230VAC 0.5A(DO)
230VAC 0.5A(DO)
Room Thermostat
-
230VAC 10mA(DI)
230VAC 10mA(DI)
Solar Pump
-
230VAC 10mA(DI)
230VAC 10mA(DI)
Valves, 2 or 3way
-
230VAC 0.5A(DO)
230VAC 0.5A(DO)
Power Supply
Type (Model Name)
Water
Pump
Type (Model Name)
Flow Switch
Min. flow rates
Electric Heater
Expansion Vessel
Pressure Relief Valve
Hydro Unit
Sound
Pressure
Sound *1
Sound
Power
External
Dimension
External
Control
*1) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
35
EHS Split
III. Hydro Unit
2. Dimensional Drawings
2-1. Hydro Unit
1) AE090/160JNYD*H/EU
(Unit : mm)
②
IN
①
OUT
③
④
No.
Table of Descriptions
①
Gas Ref. Pipe
②
Liquid Ref. Pipe
③
Water Pipe (Inlet/Outlet)
④
Drain Hose Connector
36
EHS Split
III. Hydro Unit
3. Cycle Diagrams
3-1. Hydro Unit
1) AE090/160JNYD*H/EU
No.
Description
No.
Description
①
Water Pipe Service Valve (R)
⑪
Water Pipe Service Valve (L)
②
Strainer
⑫
Water Temp. Sensor 1
③
Flow Switch
⑬
Water Temp. Sensor 2
④
Heat Changer
⑭
Water Temp. Sensor 3
⑤
Backup Heater
⑥
Pressure Relief Valve
⑦
Air-vent
⑧
Variable Speed water pump
⑨
Expansion Tank
⑩
Manometer
37
EHS Split
III. Hydro Unit
4. Wiring Diagrams
4-1. Hydro Unit
1) AE090/160JNYDEH/EU
38
EHS Split
III. Hydro Unit
4. Wiring Diagrams
4-1. Hydro Unit
2) AE090/160JNYDGH/EU
39
EHS Split
III. Hydro Unit
5. Electric Specifications
5-1. Hydro Unit
1) Power supply & Communication
2) Back-up Heater Power supply
40
EHS Split
III. Hydro Unit
5. Electric Specifications
5-1. Hydro Unit
3) Thermostat
4) 2way Valve
41
EHS Split
III. Hydro Unit
5. Electric Specifications
5-1. Hydro Unit
5) 3way Valve
5) Back-up Boiler
6) Mixing Valve
42
EHS Split
III. Hydro Unit
6. Hydraulic Performance
6-1. Water Pump
1) ESP(External Static Pressure) Diagram
The illustration below shows the external static pressure of the unit depending on the water flow and the pump setting.
If the pressure loss of total system is over 43(9 kW) or 20(16 kW)kPa, additional water pump should be installed in series.
Otherwise, the flow rate might decreased, causing insufficient heating or cooling.
When ESP is not enough, additional pump should be installed. In this case, install the PWM control external type pump additionally.
6-2. Expansion Vessel
1) Setting the pre-pressure of the expansion vessel
When it is required to change the default pre-pressure of the expansion vessel(1 bar), keep in mind the following guidelines
◆ Use only dry nitrogen to set the expansion vessel pre-pressure.
◆ Inappropriate setting of the expansion vessel pre-pressure will lead to malfunction of the system. Therefore, the pre-pressure
should only be adjusted by a licensed installer.
43
III. Application
1. Application Examples ……...…………..…..…..……… 45
2. Mixing Valve ………..…...…………..…..…..……… 47
EHS Split
III. Hydro Unit
1. Application Examples
1-1. Space Heating
1-2. Space Heating + Water Heating
45
EHS Split
III. Hydro Unit
1. Application Examples
1-3. Hybrid Application (Back-up Boiler & Solar Panel connected)
46
EHS Split
III. Hydro Unit
2. Mixing Valve
1-1. Mixing Valve Installation
1-2. Connection Of Mixing Valve
47
SI\ MSUNG
Samsung E뻐ctronics Co., LTD.
B2B PM/SE
'!'.r./'암
현