AD2C111 1 Form A Solid State Relay DESCRIPTION The AD2C111 is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. It is designed to replace electromechanical relays in general purpose switching applications. The relay consists of IR LED optically coupled to a IC that drives two rugged source-to-source enhancement type DMOS transistors. The 4 pin DIP package offers the combination of reduced package size, with 5kV input to output isolation. FEATURES APPLICATIONS • Small 4 pin DIP package outline - reduces board space • Reed relay replacement • High input-output isolation (5kVrms) • Meter reading systems • Low input control power consumption (2mA TYP) • Medical Equipment • 130mA maximum continuous load current • Battery Monitoring • 30 ohms maximum on-resistance • Multiplexers • Long life/high reliability • RoHS / Pb-Free / REACH Compliant OPTIONS/SUFFIXES* ABSOLUTE MAXIMUM RATINGS* • -S Surface Mount Leadform Option (65pcs / tube) • -TR Tape and Reel Packing Option (2,000 pcs / reel) NOTE: Suffixes listed above are not included in marking on device for part number identification. SCHEMATIC DIAGRAM + INPUT 1 4 2 3 - INPUT LOAD LOAD PARAMETER UNIT MIN Storage Temperature °C -40 125 Operating Temperature °C -40 85 Continuous Input Current mA 50 Transient Input Current (1us) mA 1 Reverse Input Control Voltage V 5 mW 500 Solder Temperature Wave (10s) °C 260 Solder Temperature - IR Reflow (10s) °C 260 Output Power Dissipation TYP MAX *The values indicated are absolute stress ratings. Functional operation of the device is not implied at these or any conditions in excess of those defined in electrical characteristics section of this document. Exposure to Absolute Ratings may cause permanent damage to the device and may adversely affect reliability. APPROVALS • UL / C-UL Approved: File # E201932 © 2011 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 Page 1 of 5 AD2C111 rev 1.43 (2/4/2011) AD2C111 1 Form A Solid State Relay ELECTRICAL CHARACTERISTICS - 25°C PARAMETER UNIT MIN TYP MAX TEST CONDITIONS 1.8 2 If = 10mA 2 5 Io = 100mA, Vo=20V T=10ms INPUT SPECIFICATIONS LED Forward Voltage V Turn-On Current mA Turn-Off Current mA 0.2 Blocking Voltage V 400 Continuous Load Current mA On-Resistance OUTPUT SPECIFICATIONS Io = 1uA 130 If = 5mA Ω 17 30 Io = 130mA Output Off-State Leakage Current µA 0.2 1 Vo = 400V I/O Capacitance pF 6 If=0, f = 1.0MHz COUPLED SPECIFICATIONS Isolation Voltage V Turn-On Time ms Turn-Off Time ms Isolation Resistance © 2011 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 GΩ 5000 T = 1 min 1 2 If = 5mA, Io = 130mA 0.05 1 If = 0mA, Io = 130mA 100 Page 2 of 5 AD2C111 rev 1.43 (2/4/2011) AD2C111 1 Form A Solid State Relay AD2C111 AD2C111 Typical Turn-On Time Distribution N = 100, Ambient Temperature = 25°C Typical Turn-Off Time Distribution N = 100, Ambient Temperature = 25°C 50 60 50 40 30 20 10 0 Device Cou 40 30 20 10 0 0.6 0.8 1 1.2 1.4 1.6 1.8 0.02 0.03 0.06 0.07 0.08 AD2C111 Typical On-Resistance Distribution N = 100, Ambient Temperature = 25°C Typical Leakage Current Distribution N = 100, Ambient Temperature = 25°C 50 40 40 30 20 10 0 15 16 17 18 19 20 30 20 10 0 21 0.04 0.045 On-Resistance (ohm s) 0.05 0.055 0.06 0.065 0.07 0.075 Leakage Current (uA) AD2C111 AD2C111 Typical Blocking Voltage Distribution N = 100, Ambient Temperature = 25°C Maximum Load Current vs. Temperature Blocking Voltage (V) © 2011 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 100 50 80 60 0 0 -4 0 380 400 420 440 460 480 500 520 150 -2 0 60 50 40 30 20 10 0 Load Current (m Device Cou 0.05 AD2C111 50 14 0.04 Turn-Off Tim e (m s) Device Cou Device Cou Turn-On Tim e (m s) 40 0.4 20 Device Cou PERFORMANCE DATA Tem perature (C) Page 3 of 5 AD2C111 rev 1.43 (2/4/2011) AD2C111 1 Form A Solid State Relay MECHANICAL DIMENSIONS 4 PIN DUAL IN-LINE PACKAGE 4 PIN SURFACE MOUNT DEVICE END VIEW END VIEW TOP VIEW TOP VIEW BOTTOM VIEW BOTTOM VIEW © 2011 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 Page 4 of 5 AD2C111 rev 1.43 (2/4/2011) AD2C111 1 Form A Solid State Relay DISCLAIMER Solid State Optronics (SSO) makes no warranties or representations with regards to the completeness and accuracy of this document. SSO reserves the right to make changes to product description, specifications at any time without further notice. SSO shall not assume any liability arising out of the application or use of any product or circuit described herein. Neither circuit patent licenses nor indemnity are expressed or implied. Except as specified in SSO's Standard Terms & Conditions, SSO disclaims liability for consequential or other damage, and we make no other warranty, expressed or implied, including merchantability and fitness for particular use. LIFE SUPPORT POLICY SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all damages resulting from such use. Life support devices are defined as devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when used properly in accordance with instructions for use can be reasonably expected to result in significant injury to the user, or (d) a critical component in any component of a life support device or system whose failure can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness. © 2011 Solid State Optronics • San José, CA www.ssousa.com • +1.408.293.4600 Page 5 of 5 AD2C111 rev 1.43 (2/4/2011)