AD4C332 - Solid State Optronics

AD4C332
Dual 1 Form B
Solid State Relay
DESCRIPTION
The AD4C332 is a bi-directional, double-pole, single-throw, normally closed multipurpose solid-state relay. It consists of two discrete solid
state relays in a compact 8 pin package. Each relay is composed of a GaAlAs LED optically coupled to an IC--driving a pair of rugged
source-to-source depletion type DMOS transistors.
FEATURES
APPLICATIONS
•
Two discrete 1 Form B relays in 1 package
•
Reed relay replacement
•
Low On-Resistance (10 Ohms MAX)
•
Meter reading systems
•
Low input control power consumption (2.5mA TYP)
•
Medical equipment
•
200mA maximum continuous load current
•
Battery monitoring
•
High input-to-output isolation
•
Multiplexers
•
Long life/high reliability
OPTIONS/SUFFIXES*
•
-S
Surface Mount Option
•
-TR
Tape and Reel Option
NOTE: Suffixes listed above are not included in marking on
device for part number identification.
SCHEMATIC DIAGRAM
ABSOLUTE MAXIMUM RATINGS*
PARAMETER
UNIT
MIN
Storage Temperature
°C
-55
125
Operating Temperature
°C
-40
85
Continuous Input Current
mA
40
Transient Input Current
mA
400
Reverse Input Control
Voltage
V
Output Power Dissipation
TYP
MAX
6
mW
800
*The values indicated are absolute stress ratings. Functional operation of the
device is not implied at these or any conditions in excess of those defined in
electrical characteristics section of this document. Exposure to Absolute
Ratings may cause permanent damage to the device and may adversely
affect reliability.
APPROVALS
•
•
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 1 of 5
BABT CERTIFICATE #607836:
BS EN 60950, BS EN 41003, BS EN 60065
CSA CERTIFICATE #LR111581-1
AD4C332
rev 1.40 (10/25/2004)
AD4C332
Dual 1 Form B
Solid State Relay
ELECTRICAL CHARACTERISTICS - 25°C
PARAMETER
UNIT
MIN
TYP
MAX
1.2
1.5
TEST CONDITIONS
INPUT SPECIFICATIONS
LED Forward Voltage
V
LED Reverse Voltage
V
Turn-On Current
Turn-Off Current
6
If = 10mA
12
Ir = 10uA
mA
0.5
Io = 200mA
mA
2.5
5
OUTPUT SPECIFICATIONS
Blocking Voltage
V
Continuous Load Current
mA
250
Io = 1uA
200
If = 5mA
8
10
Io = 200mA
µA
0.2
1
Vo = 250V
Output Capacitance
pF
25
50
Vo = 25V, f = 1.0MHz
Offset Voltage
mV
0.2
If = 0mA
On-Resistance
Ω
Leakage Current
COUPLED SPECIFICATIONS
Isolation Voltage
-H Suffix
Turn-On Time
V
2500
V
3750
T = 1 minute
T = 1 minute
ms
0.8
2
If = 0mA, Io = 200mA
Turn-Off Time
ms
1
5
If = 5mA, Io = 200mA
Isolation Resistance
GΩ
Coupled Capacitance
pF
Contact Transient Ratio
V/
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
100
2
µs
2000
Page 2 of 5
7000
dV = 50V
AD4C332
rev 1.40 (10/25/2004)
AD4C332
Dual 1 Form B
Solid State Relay
PERFORMANCE DATA
AD4C332
AD4C332
Typical Turn-On Time Distribution
N = 100, Ambient Temperature = 25°C
Typical Turn-Off Time Distribution
N = 100, Ambient Temperature = 25°C
40
Device Count
30
20
10
0
30
20
10
0
0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95
0.9
1
Turn-On Tim e (m s)
1.3
1.4
1.5
1.6
AD4C332
AD4C332
Typical On-Resistance Distribution
N = 100, Ambient Temperature = 25°C
Typical Leakage Current Distribution
N = 100, Ambient Temperature = 25°C
50
Device Count
40
30
20
10
0
7
7.5
8
8.5
9
9.5
30
20
10
0
10
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4
On-Resistance (ohm s)
Leakage Current (uA)
AD4C332
Maximum Load Current vs. Temperature
0
250 255 260 265 270 275 280 285
Blocking Voltage (V)
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
100
50
0
80
10
200
150
60
30
20
250
-2
0
40
-4
0
50
Load Current (mA)
AD4C332
Typical Blocking Voltage Distribution
N = 100, Ambient Temperature = 25°C
40
6.5
40
20
Device Count
1.2
Turn-Off Tim e (m s)
50
Device Count
1.1
0
Device Count
40
Tem perature (C)
Page 3 of 5
AD4C332
rev 1.40 (10/25/2004)
AD4C332
Dual 1 Form B
Solid State Relay
MECHANICAL DIMENSIONS
8 PIN DUAL IN-LINE PACKAGE
8 PIN SURFACE MOUNT DEVICE
END VIEW
END VIEW
TOP VIEW
TOP VIEW
BOTTOM VIEW/
BOARD PATTERN
BOTTOM VIEW/
BOARD PATTERN
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 4 of 5
AD4C332
rev 1.40 (10/25/2004)
AD4C332
Dual 1 Form B
Solid State Relay
DISCLAIMER
Solid State Optronics (SSO) makes no warranties or representations with regards to the completeness and accuracy of this document. SSO
reserves the right to make changes to product description, specifications at any time without further notice.
SSO shall not assume any liability arising out of the application or use of any product or circuit described herein. Neither circuit patent
licenses nor indemnity are expressed or implied.
Except as specified in SSO's Standard Terms & Conditions, SSO disclaims liability for consequential or other damage, and we make no other
warranty, expressed or implied, including merchantability and fitness for particular use.
LIFE SUPPORT POLICY
SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or
death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all
damages resulting from such use. Life support devices are defined as devices or systems which, (a) are intended for surgical implant into the
body, or (b) support or sustain life, and (c) whose failure to perform when used properly in accordance with instructions for use can be
reasonably expected to result in significant injury to the user, or (d) a critical component in any component of a life support device or system
whose failure can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness.
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 5 of 5
AD4C332
rev 1.40 (10/25/2004)