A77 / SMA77 Cascadable Amplifier 5 to 500 MHz Rev. V3 Features Product Image High Gain: 16.5 dB (typ.) High Level Output: +16.5 dBm (typ.) High Third Order OIP3: +30 dBm (typ.) Low VSWR: 1.3:1 (typ.) Description The A77 RF amplifier is a discrete hybrid design, which uses thin film manufacturing processes for accurate performance and high reliability. The single stage bipolar transistor feedback amplifier design displays impressive performance over a broadband frequency range. Both TO-8 and Surface Mount packages are hermetically sealed, and MIL-STD-883 environmental screening is available. Ordering Information Part Number Package A77 TO-8 SMA77 Surface Mount CA77** SMA Connectorized ** The connectorized version is not RoHs compliant. Electrical Specifications: Z0 = 50, VCC = 15 VDC Nominal* 1 Parameter Units Frequency Typical Guaranteed 25ºC 0º to 50ºC -54º to +85ºC MHz 2-600 5-500 5-500 Small Signal Gain (min.) dB 16.5 16.0 15.0 Gain Flatness (max.) dB ±0.3 ±0.7 ±1.0 Reverse Isolation dB 17 — — Noise Figure (max.) dB 4.5 5.0 5.5 Power Output @ 1 dB comp. (min.) dBm 16.5 15.0 14.5 IP3 dBm +30 — — IP2 dBm +43 — — Second Order Harmonic IP dBm +49 — — VSWR Input / Output (max.) — 1.3:1 / 1.3:1 1.7:1 / 1.7:1 2.0:1 / 2.0:1 DC Current (max.) mA 50 53 56 Over temperature performance limits for part number CA77, guaranteed from 0oC to +50oC only. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support A77 / SMA77 Cascadable Amplifier 5 to 500 MHz Rev. V3 Absolute Maximum Ratings Thermal Data: VCC = 15 VDC Parameter Absolute Maximum Parameter Rating Storage Temperature -62ºC to +125ºC Thermal Resistance θjc 130ºC/W Case Temperature 125ºC Transistor Power Dissipation Pd 0.464 W DC Voltage +17 V Continuous Input Power +13 dBm Junction Temperature Rise Above Case TJC 60ºC Short Term Input power (1 minute max..) 100 mW Peak Power (3 µsec max..) 0.5 W “S” Series Burn-In Temperature (case) 125ºC Typical Performance Curves 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support A77 / SMA77 Cascadable Amplifier 5 to 500 MHz Rev. V3 Outline Drawing: TO-8 * Outline Drawing: Surface Mount Outline Drawing: SMA Connectorized Dimensions are inches (millimeters) ±0.015 (0.38) unless otherwise specified. 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support A77 / SMA77 Cascadable Amplifier 5 to 500 MHz Rev. V3 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. 4 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support