MAAVSS0005

MAAVSS0005
Voltage Variable Absorptive Attenuator
DC - 2.0 GHz
Functional Schematic
Features











Rev. V2
12-dB Attenuation at 1 GHz
Low Intermodulation Products
Low DC Power Consumption
Single Voltage Control: 0 to -4 Volts
Nanosecond Switching Speed
Temperature Range: -40°C to + 85°C
Lead-Free SOT-143 Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of AT-259
Description
M/A-COM’s MAAVSS0005 is a GaAs MMIC voltage
variable absorptive attenuator in a lead-free
SOT-143 4-lead surface mount plastic package.
The MAAVSS0005 is ideally suited for use where
attenuation fine tuning, fast switching and very low
power consumption are required.
Ordering Information
3
1
2
Pin Configuration
Pin No.
Function
Pin No.
Function
1
Ground
3
RF2
2
VC
4
RF1
Typical applications include radio, cellular, GPS
equipment and other automatic gain/level control
circuits.
The MAAVSS0005 is fabricated with a monolithic
GaAs MMIC using a mature 1 micron process. The
process features full chip passivation for increased
performance and reliability.
4
Absolute Maximum Ratings 3,4
1,2
Parameter
Absolute Maximum
Input Power
+21 dBm
Control Voltage
-8.5 V < VC < +5 V
Part Number
Package
Operating Temperature
-40°C to +85°C
MAAVSS0005
Bulk Packaging
Storage Temperature
-65°C to +150°C
MAAVSS0005TR-3000
3000 piece reel
MAAVSS0005SMB
Sample Board
1. Reference Application Note M513 for reel size information.
2. All sample boards include 5 loose parts.
3. Exceeding any one or combination of these limits may cause
permanent damage to this device.
4. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAVSS0005
Voltage Variable Absorptive Attenuator
DC - 2.0 GHz
Rev. V2
Electrical Specifications: TA = 25°C, Z0 = 50 Ω
Test Conditions5
Frequency
Units
Min.
Typ.
Max.
Insertion Loss
—
DC - 0.1 GHz
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
dB
dB
dB
dB
—
—
—
—
2.9
3.0
3.2
3.4
3.1
3.2
3.5
3.8
Flatness
(Peak to Peak)
5 dB Attenuation
10 dB Attenuation
15 dB Attenuation
DC - 2.0 GHz
DC - 2.0 GHz
DC - 2.0 GHz
dB
dB
dB
—
—
—
+ 0.2
+ 2.3
+ 7.0
—
—
—
Output Impedance
—
—
Ohms
—
50
—
VSWR
—
DC - 2.0 GHz
Ratio
—
2.1:1
—
Trise, Tfall
10% to 90% RF, 90% to 10% RF
—
nS
—
3
—
Ton, Toff
50% Control to 90% RF,50% Control to 10% RF
—
nS
—
5
—
Transients
In Band
—
mV
—
10
—
IP2
Measured Relative to Input Power
(For two-tone Input Power Up to +5 dBm)
0.05 GHz
0.5 - 2.0 GHz
dBm
dBm
—
—
34
47
—
—
IP3
Measured Relative to Input Power
(For two-tone Input Power Up to +5 dBm)
0.05 GHz
0.5 - 2.0 GHz
dBm
dBm
—
—
31
36
—
—
Parameter
5. Control voltage: 0 to -4 volts @ 20 µA typical.
Lead-Free SOT-143†
†
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAVSS0005
Voltage Variable Absorptive Attenuator
DC - 2.0 GHz
Rev. V2
Typical Performance Curves
Insertion Loss vs. Frequency
Attenuation vs. Frequency
4
20
3
15
+25°C
-40°C
+85°C
2
5
10
15
10
5
1
0
0.0
0.5
1.0
1.5
2.0
0
0.0
0.5
1.0
1.5
2.0
Frequency (GHz)
Frequency (GHz)
VSWR vs. Frequency
Attenuation vs. Control Voltage, F = 950 MHz
15
2.0
1.8
10
1.6
0
12
5
1.4
5
1.2
1.0
0.0
0.5
1.0
Frequency (GHz)
1.5
2.0
0
-3.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
Control Voltage (V)
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAVSS0005
Voltage Variable Absorptive Attenuator
DC - 2.0 GHz
Rev. V2
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support