MAAV-007941

MAAV-007941
Voltage Variable Absorptive Attenuator
12 dB, DC - 2.0 GHz
Features











Rev. V1
Functional Schematic
12 dB Voltage Variable Attenuation
Low Intermodulation Products
Low DC Power Consumption: 50 W
Single Voltage Control: 0 to -4 Volts
Nanosecond Switching Speed
Temperature Range: -40°C to +85°C
Lead-Free SOIC-8 Plastic Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of AT-250
Description
M/A-COM’s MAAV-007941 is a GaAs MMIC voltage
variable absorptive attenuator in a low cost lead-free
SOIC 8-lead surface mount plastic package. The
MAAV-007941 is ideally suited for use where
attenuation fine tuning, fast switching and very low
power consumption are required.
Typical applications include radio, cellular, GPS
equipment and other automatic gain/level control
circuits.
The MAAV-007941 is fabricated with a monolithic
GaAs MMIC using a mature 1-micron process. The
process features full chip passivation for increased
performance and reliability.
Ordering Information 1
RF2
GND
GND
GND
8
7
6
5
1
2
3
4
RF1
GND
GND
VC
Pin Configuration
Pin No.
Function
Pin No.
Function
1
RF1
5
Ground
2
Ground
6
Ground
3
Ground
7
Ground
4
VC
8
RF2
Absolute Maximum Ratings 2
Part Number
Package
MAAV-007941-000000
Bulk Packaging
MAAV-007941-TR3000
3000 piece reel
1. Reference Application Note M513 for reel size information.
Parameter
Absolute Maximum
Input Power
+21 dBm
Control Voltage
+5V, -8.5V
Operating Temperature
-40°C to +85°C
Storing Temperature
-65°C to +150°C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
* Restrictions on Hazardous Substances, European Directive 2002/95/EC.
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAV-007941
Voltage Variable Absorptive Attenuator
12 dB, DC - 2.0 GHz
Rev. V1
Electrical Specifications: TA = 25°C, Z0 = 50 
Parameter
Test Conditions 3
Units
Min.
Typ.
Max.
Insertion Loss
DC - 0.1 GHz
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
dB
dB
dB
dB
—
—
—
—
2.9
3.0
3.2
3.4
3.1
3.2
3.5
3.8
Flatness
(Peak to Peak)
DC - 0.1 GHz
DC - 0.5 GHz
DC - 1.0 GHz
DC - 2.0 GHz
dB
dB
dB
dB
—
—
—
—
+ 0.1
+ 0.2
+ 0.5
+ 1.2
+ 0.3
+ 0.4
+ 0.8
+ 1.5
Ratio
—
2.1:1
—
VSWR
Trise, Tfall
10% to 90% RF, 90% to 10% RF
nS
—
3
—
Ton, Toff
50% Control to 90% RF,
50% Control to 10% RF
nS
—
5
—
Transients
In Band
mV
—
10
—
Power Handling
Linear Operation
Absolute Maximum Input Power
dBm
dBm
—
—
13
21
—
—
IP2
0.05 GHz
0.5 - 2.0 GHz
Measured Relative to Input Power
(For two-tone Input Power Up to +5 dBm)
dBm
dBm
28
40
34
47
—
—
0.05 GHz
0.5 - 2.0 GHz
Measured Relative to Input Power
(For two-tone Input Power Up to +5 dBm)
dBm
dBm
18
18.5
31
36
—
—
IP3
4
3. Control voltage: 0 to -4 volts @ 20 µA typical.
4. Typical readings are for levels above 6 dB attenuation. For levels below 6 dB, the minimum specification numbers apply.
Lead-Free SOIC-8†
†
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAV-007941
Voltage Variable Absorptive Attenuator
12 dB, DC - 2.0 GHz
Rev. V1
Typical Performance Curves
Insertion Loss vs. Frequency
Attenuation vs. Frequency
20
4
Atten5
Atten10
Atten15
15
3
+25°C
-40°C
+85°C
2
10
5
1
0
0.0
0.5
1.0
1.5
0
0.0
2.0
0.5
1.0
1.5
2.0
Frequency (GHz)
Frequency (GHz)
Attenuation vs. Control Voltage, F = 950 MHz
VSWR vs. Frequency
15
2.0
1.8
10
1.6
0 dB
12 dB
5 dB
1.4
5
1.2
1.0
0.0
0.5
1.0
1.5
0
-3.0
2.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
Control Voltage (V)
Frequency (GHz)
Phas
30
Handling Procedures
Please observe the following precautions to avoid
damage:
20
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
10
0
-3.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
Control Voltage (V)
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAAV-007941
Voltage Variable Absorptive Attenuator
12 dB, DC - 2.0 GHz
Rev. V1
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
4
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support