MAAVSS0008 Voltage Variable Absorptive Attenuator 30 dB, 0.5 - 2.0 GHz Functional Schematic 3,4,5 Features Rev. V3 Single Positive Voltage Control: 0 to +5 Volts 30 dB Voltage Variable Attenuation ± 2 dB Linearity from BSL Low DC Power Consumption Temperature Range: -40°C to +85°C Fast Switching Speed Lead-Free SOIC-8 Package 100% Matte Tin Plating over Copper Halogen-Free “Green” Mold Compound 260°C Reflow Compatible RoHS* Compliant Version of AT-110-2 8 7 6 5 1 2 3 4 Description M/A-COM’s MAAVSS0008 is a GaAs MMIC voltage variable absorptive attenuator in a lead-free SOIC-8 surface mount plastic package. The MAAVSS0008 is ideally suited for use where linear attenuation fine tuning and very low power consumption are required. Typical applications include radio, cellular, GPS equipment and automatic gain/level control circuits. The MAAVSS0008 is fabricated with a monolithic GaAs MMIC using a mature 1-micron process. The process features full chip passivation for increased performance and reliability. Ordering Information 1,2 Part Number Package MAAVSS0008 Bulk Packaging MAAVSS0008TR 1000 piece reel MAAVSS0008SMB Sample Board 1. Reference Application Note M513 for reel size information. 2. All sample boards include 5 loose parts. 3. VCC = +5 VDC ± 0.5 VDC @ 300 µA maximum. 4. VC = 0 VDC to +5 VDC @ 6.6 mA maximum. 5. External DC blocking capacitors are required on all RF ports. Pin Configuration Pin No. Function Pin No. Function 1 Ground 5 VC 2 Ground 6 Ground 3 RF Port 7 RF Port 4 VCC 8 Ground Absolute Maximum Ratings 6,7 Parameter Absolute Maximum Input Power +21 dBm Supply Voltage VCC -1 V < VCC < +8 V Control Voltage VC -1 V < VC < VCC + 0.5 V Operating Temperature -40°C to +85°C Storage Temperature -65°C to +150°C 6. Exceeding any one or combination of these limits may cause permanent damage to this device. 7. M/A-COM does not recommend sustained operation near these survivability limits. * Restrictions on Hazardous Substances, European Directive 2002/95/EC. 1 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAVSS0008 Voltage Variable Absorptive Attenuator 30 dB, 0.5 - 2.0 GHz Rev. V3 Electrical Specifications8: TA = 25°C, Z0 = 50 Parameter Test Conditions Units Min. Typ. Max. Insertion Loss 0.5 - 1.0 GHz 1.0 - 2.0 GHz dB dB — — 2.8 3.3 3.0 3.6 Attenuation 1.0 GHz 1.0 - 2.0 GHz dB dB 37.5 25 — — — — Flatness (Peak to Peak) 0.5 - 1.0 GHz 1.0 - 2.0 GHz dB dB — — ± 0.5 ± 1.2 ± 0.8 ± 1.5 VSWR — Ratio — 2:1 — Trise, Tfall 10% to 90% RF, 90% to 10% RF µS — 0.2 — Ton, Toff 50% Control to 90% RF, 50% Control to 10% RF µS — 0.2 — Transients In-band mV — 70 — 8. External DC blocking capacitors are required on all RF ports. Lead-Free SOIC-8† † Reference Application Note M538 for lead-free solder reflow recommendations. Meets JEDEC moisture sensitivity level 1 requirements. Handling Procedures Please observe the following precautions to avoid damage: Static Sensitivity Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAVSS0008 Voltage Variable Absorptive Attenuator 30 dB, 0.5 - 2.0 GHz Rev. V3 Typical Performance Curves @ 25°C Attenuation vs. Control Voltage, F = 900, 1800 MHz 0 Attenuation vs. Temperature Normalized to +25°C, F = 900 MHz 3 1800 900 -10 -40°C +85°C 2 1 -20 0 -1 -30 -2 -40 5 4 3 2 1 0 -3 5 4 Control Voltage (V) Insertion Loss vs. Frequency 0 3 -10 2 -20 1 -30 1.0 2 1 0 Return Loss vs. Control Voltage, F = 900 MHz 4 0 0.5 3 Control Voltage (V) 1.5 2.0 -40 5 4 3 2 1 0 1 0 Control Voltage (V) Frequency (GHz) 1 dB Compression vs. Control Voltage. F = 900 MHz IP3 vs. Control Voltage 40 40 30 30 20 20 400 MHz 900 MHz 10 0 10 5 4 3 2 Control Voltage (V) 1 0 0 5 4 3 2 Control Voltage (V) 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MAAVSS0008 Voltage Variable Absorptive Attenuator 30 dB, 0.5 - 2.0 GHz Rev. V3 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. 4 MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support