CTE/CTU7000 pressure transmitter

CTE7000 / CTU7000 Series
Miniature pressure transmitters
FEATURES
· 10 mbar to 5 bar, 0.15 to 75 psi
gage1 pressure
· 0...5 V, 0...10 V, 0.5...4.5 V, 1...6 V or
4...20 mA output
· Field interchangeable
· Rugged stainless steel housing
· EMC according to EN 61326-19
MEDIA COMPATIBILITY
Pressure inlet:
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.10
Housing:
Stainless steel 1.4404 (316L), protection class IP 67
(according to DIN EN 60529, NEMA 6)1
SPECIFICATIONS11,12
ELECTRICAL CONNECTION
Maximum ratings
Voltage output device
Supply voltage (reverse polarity protection)
CTE(M)/CTU7...0
12...32 V
CTE(M)/CTU7...1
9...32 V
CTE(M)/CTU7...6, ...7
8...32 V
CTE(M)/CTU7...42
7...32 V
Maximum load current (source)
CTE(M)/CTU7...0, ...1, ...6, ...7
+Vs
1 / brown
sensor
1 mA
Vibration (5 to 2000 Hz)14
Mechanical shock15
E / 11507 / C
Vout
2 / green
-Vs
V
4 / yellow
case
100 mbar/1.5 psi
1.3 bar/20 psi
7 bar/100 psi
2 x rated pressure
3 / white/shield
Current output device
+Vs
Environmental
Temperature limits
Storage
Operating (media)
Electronic (ambient)
Compensated
Vout
-Vs
3
Proof pressure
CTE...010, 025/CTU...0x15, 0x3
CTE...070, 350/CTU...01, 05
CTE...005/CTU...075
all others
+Vs
+Vs
1 / brown
N/C
-40...85 °C
-25...85 °C
-25...85 °C
0...50 °C
10 gRMS
sensor
2 / green
V
-Vs
RL
-Vs
4 / yellow
case
3 / white/shield
50 g (11 ms)
1/6
www.first-sensor.com
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
COMMON PERFORMANCE CHARACTERISTICS
(VS=15 V ±0.1 V, TA=25 °C, RH=50 %)
Characteristics
Thermal effects
(0...50 °C)4
Offset
Min.
Typ.
Max.
devices up to 70 mbar/1 psi
±0.08
±0.13
all others
±0.01
±0.05
±0.02
±0.04
±0.2
±0.5
Span
Non-linearity (BSL) and hysteresis
5
6
±0.2
Repeatability
7
Long term stability
±0.5
Output noise (0 < f < 1 kHz)
Response time (10 to 90 %)
±0.1
devices up to 25 mbar/0.3 psi
35
all others
5
Unit
%FSO/°C
%FSO
ms
D/A resolution
11
Power supply rejection Offset
±0.01
Span
±0.02
bi t
%FSO/V
INDIVIDUAL PERFORMANCE CHARACTERISTICS13
(VS=15 V ±0.1 V, TA=25 °C, RH=50 %)
0...10 V output (RL > 100 kΩ)
Characteristics
Zero pressure offset
Full scale span8
CT...7N...
all others
CT...7N...
all others
Min.
Typ.
Max.
4.9
5
0
5
10
5.1
0.1
5.1
10.1
25
4.9
9.9
Output impedance
Current consumption (no load)
4
Unit
V
Ω
mA
0.5...4.5 V output (RL > 100 kΩ)
Characteristics
Zero pressure offset
Full scale span8
CT...7N...
all others
CT...7N...
all others
Min.
Typ.
Max.
2.45
0.45
1.95
3.95
2.5
0.5
2
4
2.55
0.55
2.05
4.05
25
Output impedance
Current consumption (no load)
E / 11507 / C
4
Unit
V
Ω
mA
2/6
www.first-sensor.com
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS13 (cont.)
(VS=15 V ±0.1 V, TA=25 °C, RH=50 %)
0...5 V output (RL > 100 kΩ)
Characteristics
Zero pressure offset
Full scale span8
CT...7N...
all others
CT...7N...
all others
Min.
Typ.
Max.
2.45
-0.05
2.45
4.95
2.5
0
2.5
5.0
2.55
0.05
2.55
5.05
25
Output impedance
Current consumption (no load)
4
Unit
V
Ω
mA
1...6 V output (RL > 100 kΩ)
Characteristics
Zero pressure offset
Full scale span8
CT...7N...
all others
CT...7N...
all others
Min.
Typ.
Max.
3.45
0.95
2.45
4.95
3.5
1.0
2.5
5.0
3.55
1.05
2.55
5.05
25
Output impedance
Current consumption (no load)
4
Unit
V
Ω
mA
4...20 mA output (RL = 100 Ω)
Characteristics
Zero pressure offset
Full scale span8
Min.
Typ.
Max.
Unit
11.8
3.8
7.8
15.8
12.0
4.0
8.0
16.0
250
12.2
4.2
8.2
16.2
mA
CT...7N...
all others
CT...7N...
all others
Power consumption (IL = 20 mA)
mW
LOAD LIMITATION
4...20 mA output version
1400
Ohm
1200
1000
800
op
e
ra ratin
ng g
e
600
400
200
0
E / 11507 / C
5 7 10
16
20 25 30 32 V
supply voltage
3/6
www.first-sensor.com
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
OUTLINE DRAWING
Connector version
NOM 72.0 (2.83)
6.5
(0.26)
vent hole¹
52.0 (2.05)
G 1/8"
(BSP)
1
M12 x 1
21.8 (0.86)
diam.
4
Detail A
3
2
Pin
1
2
3
4
Output
Voltage
Current
+Vs
Vout
C a se
-Vs
+Vs
N/C
C a se
-Vs
Cable version
6.5
(0.26)
52.0 (2.05)
NOM
15.0 (0.59)
2 m (78.74)
other lenghts available
G 1/8"
(BSP)
21.8 (0.86)
diam.
Shield
Vent tube
Detail A
Flying lead end
Current
+Vs
Vout
C a se
-Vs
+Vs
N/C
C a se
-Vs
3.4 (0.13)
diam.
11.0 (0.43)
Detail A
15.2 (0.60)
Brown
Green
White and shield
Yellow
Output
Voltage
O-ring grove
1.3 (0.05)
mass: approx. 60 g
E / 11507 / C
Note: O-ring included in delivery
dimensions in mm (inches)
4/6
www.first-sensor.com
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
RECOMMENDED ACCESSORY (not included in delivery)
ZP000112-B:
ZK000101-x:
Mating Connector (without cable)
Connector/cable assembly (x=cable lenghts in m, max. 10 m)
x = length in m
(max. 10 m)
PIN CONNECTION
NOM 60
36.5
Shield
Pin
Flying lead end
1
Brown
2
Green
3
White and shield
4
Yellow
Vent tube
Note:
For proper function of all gage
devices the vent tube must have
access to the ambient atmosphere.
M12x1
Ø 20
dimensions in mm
OPTIONAL PRESSURE FITTINGS
(brass, nickel plated)
B
Male
fittings
C
A
D
E
E / 11507 / C
B
8 (0.315)
12 (0.472)
11.5 (0.453)
16 (0.630)
12.5 (0.492)
8.5 (0.335)
12.5 (0.492)
10 (0.394)
14 (0.551)
C
13 (0.512)
5.5 (0.217)
5 (0.197)
7 (0.276)
11 (0.433)
5 (0.197)
7 (0.276)
13 (0.512)
6 (0.236)
H
Dimensions in mm (inches)
Dimensions in mm (inches)
A
1/8" BSPT
1/4" BSPT
3/8" BSPT
1/2" BSPT
1/8" BSP
1/4" BSP
3/8" BSP
1/8" NPT
1/4" NPT
G
F
Female
fittings
D (Hex.)
14 (9/16")
14 (9/18")
17 (11/16")
22 (7/8")
14 (9/16")
19 (3/4")
22 (7/8")
17 (11/16")
22 (7/8")
E
1/8" BSP
1/4" BSP
3/8" BSP
1/2" BSP
F
5 (0.197)
7 (0.276)
6 (0.236)
18 (0.707)
G
15 (0.591)
20 (0.787)
20 (0.787)
23 (0.906)
H (Hex.)
14 (9/16")
17 (11/16")
22 (7/8")
24 (15/16")
5/6
www.first-sensor.com
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
Specification notes:
1. IP 67 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere
through the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0...50 °C relative to 25 °C. All specifications shown are relative to 25 °C.
Signal is clamped at 0 V.
5. Non-linearity refers to Best Straight Line fit. Hysteresis is the maximum output difference at any point within the
operating pressure range for increasing and decreasing pressure.
6. Maximum difference in offset respectively maximum difference in span within the temperature range of 0...50 °C after:
a) 100 temperature cycles, 0...50 °C.
b) 1.0 million pressure cycles, 0 to full scale span.
7. Long term stability is the change in output after one year.
8. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
9. Surge immunity according to EN 61000-4-5 on request for current output devices.
10. When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also.
11. CE-labelling is in accordance with 2004/108/EC.
12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
13. Devices <100 mbar are position sensitive regarding the zero pressure offset. A vertical mounting position with the pressure
connection downward is recommended.
14. According to IEC 60068-2-64.
15. According to IEC 60068-2-27.
ORDERING INFORMATION
CTx (M) 7xxxx
x x x (C x)
Calibration
E: bar calibration
U: psi calibration
Cable length in m
Cable version (optional)
For mbar ranges only
Pressure range
CTE7000 series
0010:
0...10 mbar
N010:
-10...10 mbar
0025:
0...25 mbar
N025:
-25...25 mbar
0070:
0...70 mbar
N070:
-70...70 mbar
0100:
0...100 mbar
0200:
0...200 mbar
0350:
0...350 mbar
N350: -350...350 mbar
001:
0...1 bar
N01:
-1...+1 bar
P01:
0...-1 bar
002:
0...2 bar
005:
0...5 bar
CTU7000 series
00x15:
0...0.15
N0x15: -0.15...0.15
00x3:
0...0.3
N0x3:
-0.3...0.3
001:
0...1
N01:
-1...1
005:
0...5
N05:
-5...5
015:
0...15
N15:
-15...15
P15:
0...-15
030:
0...30
075:
0...75
psi
psi
psi
psi
psi
psi
psi
psi
psi
psi
psi
psi
psi
Pressure mode
G: gage pressure1
Other pressure ranges and options are widely available.
Please contact First Sensor.
Output signal
0: 0...10 V
1: 1...6 V
4: 4...20 mA
6: 0.5...4.5 V
7: 0...5 V
Pressure connection
Standard thread
Y: G 1/8" (BSP) male, SS 1.4404 (316L)
Optional pressure fittings
D: 1/8" BSPT male, brass, nickel plated
E: 1/4" BSPT male, brass, nickel plated
F: 3/8" BSPT male, brass, nickel plated
G: 1/2" BSPT male, brass, nickel plated
K: 1/8" NPT male, brass
L: 1/4" NPT male, brass
M: 1/8" NPT male, SS 1.4404 (316L)
N: 1/4" NPT male, SS 1.4404 (316L)
P: G 1/8" (BSP) male, brass, nickel plated
Q: G 1/4" (BSP) male, brass, nickel plated
R: G 3/8" (BSP) male, brass, nickel plated
S: G 1/2" (BSP) male, brass, nickel plated
U: G 1/8" (BSP) female, brass, nickel plated
V: G 1/4" (BSP) female, brass, nickel plated
W: G 3/8" (BSP) female, brass, nickel plated
X: G 1/2" (BSP) female, brass, nickel plated
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11507 / C
6/6
www.first-sensor.com
www.sensortechnics.com