VSO-EPTM / VSO-EVTM

TM
VSO-EP / VSO-EV
TM
Electronic pressure controllers
FEATURES
· Offers silent operation
· Ensures high accuracy and resolution
· Tested for long life
· Offers internal closed loop control and
external pressure sensor capability*
· OEM application-specific configurations
available
· Includes thermally compensated
proportional VSO® valve
* Accessory required
MEDIA COMPATIBILITY
Non-corrosive gases
ELECTRICAL
ELECTRICAL CONNECTION
Power
24 VDC ± 10%
(12 VDC available)
J1
0...5 VDC
(4...20 mA available)
1
+24 V DC
2
Monitor output voltage
0...5 VDC
Control voltage in (setpoint)
3
Current requirement
<150 mA
Monitor voltage out
4
Electrical connector
RJ-45, accepts Cat 5e
cables up to 100 feet
Input control signal
Storage temperature
Porting
N.C.
CAT 5e plug-in (RJ-45) connector (included)
PHYSICAL PROPERTIES
Operating environment
5-8
0 to 55 °C
-40 to 55 °C
10-32 UNF female ports
Signal
RJ-45 pin # color
Main power, 24 VDC
1
Input control, 0 to 5 VDC
2 Solid orange
Monitor output, 0 to 5 VDC
3 White w/ green
System ground
4 Solid blue
White w/ orange
VSO is a registered trademark and VSO EP is a trademark of Parker Hannifin Corporation.
E / 11256 / A
1/4
www.first-sensor.com
www.sensortechnics.com
TM
VSO-EP / VSO-EV
TM
Electronic pressure controllers
PRESSURE RANGES CHARACTERISTICS
Part no.
Pressure range*
VSOEP...0-15
0...15 psig
VSOEP...0-30
0...30 psig
VSOEP...0-50
0...50 psig
VSOEP...0-100
0...100 psig
VSOEV...0-150
0...-150 mbar (Vacuum)
VSOEV...0-345
0...-345 mbar (Vacuum)
Maximum supply pressure
150% of pressure transducer rating
* Custom ranges available (including 0...2, 0...5, 0...7, 0...70 psig and vacuum ranges)
PERFORMANCE CHARACTERISTICS
Characteristics
Min.
Pressure accuracy
Non-linearity
Response time*
Typ.
Max.
±0.2
±1.5
±1.0
15
Unit
%FS
ms
* Response time to target pressure is output volume dependent
CONFIGURATIONS
Pressure control: Standard configuration
Pressure control: Alternate configuration
E / 11256 / A
2/4
www.first-sensor.com
www.sensortechnics.com
TM
VSO-EP / VSO-EV
TM
Electronic pressure controllers
CONFIGURATIONS (cont.)
Vacuum control: Standard configuration
Vacuum Souce
PHYSICAL DIMENSIONS
2.320
(58.9)
J1 connector access
Molex CAT-5 #95040
1.270
(32.3)
2.198
(55.8)
2.135
(54.2)
0.597
(15.2)
2 x 0.20
(5.1)
2 x 8-32 UNC-2B 0.22 (5.59)
for mounting purposes
#10-32 UNF-2B 0.21 (5.33)
both ends (source and requirement)
pressure source this side
0.34 ±0.02
(8.64 ±0.51)
0.16 ±0.02
(4.06±0.51)
mass: approx. 150 g
E / 11256 / A
2 x 0.73
(18.5)
2.000
(50.8)
third angle projection
dimensions in inches (mm)
3/4
www.first-sensor.com
www.sensortechnics.com
TM
VSO-EP / VSO-EV
TM
Electronic pressure controllers
ORDERING INFORMATION
VSO-EP (pressure controllers)
Options
Series
Configuration
Valve orifice
VSOEP
S: Standard pressure control
1:
0.01 "
A: Alternate pressure control
3:
0.03 "
Electrical input
0-5:
0...5 VDC
Pneumatic range*
0-15:
0...15 psi
0-30:
0...30 psi
0-50:
0...50 psi
0-100:
0...100 psi
* for custom pressure
ranges contact First Sensor
Available listings:
VSOEPS10-50-15
VSOEPS10-50-50
VSOEPS10-50-100
VSOEPS30-50-15
VSOEPS30-50-50
VSOEPS30-50-100
VSOEPA10-50-15
VSOEPA10-50-50
VSOEPA10-50-100
VSOEPA30-50-30
VSO-EV (vacuum controllers)
Options
Series
Configuration
VSOEV
E: Standard vaccum control
Valve orifice
1:
0.01 "
3:
0.03 "
Electrical input
0-5:
0...5 VDC
Pneumatic range*
0-150: 0...-150 mbar
0-345: 0...-345 mbar
* for custom pressure ranges
contact First Sensor
Available listings:
VSOEVE10-50-150
VSOEVE30-50-345
Custom pressure ranges and configurations are available. Please contact First Sensor.
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11256 / A
4/4
www.first-sensor.com
www.sensortechnics.com