HDU Series - First Sensor

HDU Series
Basic pressure sensors
FEATURES
·100 mbar to 5 bar, 1 to 70 psi
absolute, gage or differential pressure
·DIP housings
·RoHS compliant
Media compatibility
To be used with non-corrosive, non-ionic working fluids such as clean dry air, dry gases and the like.
EQUIVALENT CIRCUIT
SPECIFICATIONS
Maximum ratings
Supply voltage VS
+12 VDC
Lead specifications
Average preheating temperature gradient 2.5 K/s
Soak time
ca. 3 min
Time above 217°C
50 s
Time above 230°C
40 s
Time above 250°C
15 s
Peak temperature
260°C
Cooling temperature gradient
-3.5 K/s
Temperature ranges
Operating
Storage
-40 ... 85 °C
-40 ... 125 °C
Humidity limits (non-condensing)
0 ... 95 %RH
E / 11803 / D
+Vs
-Vout
+Vout
GND1
GND2
1/4
www.first-sensor.com
www.sensortechnics.com
HDU Series
Basic pressure sensors
Pressure sensor Characteristics
(VS=5.0 VDC, TA=25 °C, RH=50 %, common mode line pressure = 0 bar, pressure applied to high pressure port)
Part number
Operating pressure Proof pressure1
HDUM100...
HDUM350...
HDUB001...
HDUB2x5...
HDUB005...
HDUP001...
HDUP005...
HDUP015...
HDUP030...
HDUP070...
0...100 mbar
0...350 mbar
0...1 bar
0...2.5 bar
0...5 bar
0...1 psi
0...5 psi
0...15 psi
0...30 psi
0...70 psi
2 bar
2 bar
5 bar
7 bar
7 bar
30 psi
30 psi
75 psi
100 psi
100 psi
Full-scale span2
Min.
30 mV
40 mV
60 mV
60 mV
60 mV
20 mV
39 mV
61 mV
49 mV
58 mV
Typ.
60 mV
100 mV
100 mV
100 mV
100 mV
41 mV
98 mV
103 mV
83 mV
96 mV
Max.
120 mV
160 mV
140 mV
140 mV
140 mV
83 mV
158 mV
145 mV
116 mV
136 mV
PERFORMANCE CHARACTERISTICS
(VS=5.0 VDC, TA=25 °C, RH=50 %, common mode line pressure = 0 bar, pressure applied to high pressure port)
Characteristics
Zero pressure offset
Temperature effects
(25...85 °C)
Non-linearity3
100 mbar/1 psi devices
all others
Offset
1 psi devices
100 mbar devices
350 mbar/5 psi devices
all others
Span
1 psi devices
100 mbar devices
all others
Bridge impedance
100 mbar/1 psi devices
all others
Hysteresis4
Repeatability
Long term stability5
Bridge resistance
Response time6
Min.
-40
-30
-0.45
-0.30
-0.20
-0.1
-0.35
-0.23
-0.21
0.20
2.8
Typ.
0
0
-0.22
-0.15
-0.07
±0.02
-0.25
-0.20
-0.20
0.26
±0.5
±0.1
±0.1
±0.5
±0.1
3.3
100
Max.
40
30
0
0
0
0.1
-0.18
-0.18
-0.17
0.31
±1.1
±0.5
Unit
mV
%FSS/°C
%/°C
%FSS
3.8
kW
µsec
Specification notes:
1.
2.
3.
4.
5.
6.
Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element.
Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
Non-linearity refers to the Best Straight Line fit, measured for offset pressure, full scale pressure and 1/2 full scale pressure.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
Long term stability over a one year period.
Response time for a zero to full scale span pressure step change, 10 to 90 % rise time.
E / 11803 / D
2/4
www.first-sensor.com
www.sensortechnics.com
HDU Series
Basic pressure sensors
PHYSICAL DIMENSIONS and electrical connection
HDU...AZ... (DIP, 1 port axial, absolute pressure)
low pressure
port
11,90
13,01
3,41
2,54
2,69
3,03
15,70
5,08
Connection
+Vout
GND1
-Vout
+Vs
GND2
+Vs
high pressure
port
0,46
5
6
0,63
5,73
4
8,83
2
Pin
1
2
3
4
5
6
Note:
The polarity indicated is for
pressure applied to high
pressure port.
0,25
15
8
2
R
0,
40
3
first angle projection
pin marking
1
dimensions in mm
HDU...GZ... (DIP, 1 port axial, gage pressure)
13,01
11,90
3,41
2,54
5,08
2,69
3,03
15,70
0,25
15
8
Connection
+Vs
GND1
+Vs
-Vout
GND2
+Vout
Note:
The polarity indicated is for
pressure applied to high
pressure port.
high pressure
port
0,46
5
4
0,63
5,73
2
6
8,83
Pin
1
2
3
4
5
6
pin marking
1
R0
,4
2
3
low pressure
port (Venthole)
0
first angle projection
dimensions in mm
E / 11803 / D
3/4
www.first-sensor.com
www.sensortechnics.com
HDU Series
Basic pressure sensors
PHYSICAL DIMENSIONS and electrical connection (cont.)
4,10
HDU...DF... (DIP, 2 ports same side, differential pressure)
6,23
3,41
2,54
Pin
1
2
3
4
5
6
3,40
0,25
2,68
2,30
15
15,70
11,90
9,28
Note:
The polarity indicated is for
pressure applied to high
pressure port.
5,08
1,90
3,35
0,46
Connection
+Vs
GND1
+Vs
-Vout
GND2
+Vout
low pressure
port
R0
,
40
0,63
10,93
9,64
8,83
5,73
4 5
6
7,60
18,75
19,50
high pressure
port
first angle projection
3 2
1
dimensions in mm
pin marking
ORDERING INFORMATION
Options
Series
HDU
Pressure range
Pressure mode
M100
100 mbar A* Absolute
M350
350 mbar D Differential
B001
1 bar G Gage
B2x5
2.5 bar
B005
5 bar
P001
1 psi
P005
5 psi
P015
15 psi
P030
30 psi
P070
70 psi
* only available from
1 bar/15 psi onwards
Example:
HDU
B001
G
F*
Housing
DIP, 2 ports
same side
Options
P Prime grade
Z** DIP, 1 port
axial
* standard for differential
devices, "D"
** standard for absolute
and gage devices,
"A" and "G"
Z
P
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
E / 11803 / D
4/4
www.first-sensor.com
www.sensortechnics.com