TE10

TE10
10W-12W Single Output External Power
Test & Measurement/Industrial Series
Features

Meets DoE Efficiency Level VI Requirements
 No load input power
 Average Efficiency

Up to 12W of AC-DC Power

Universal Input 90-264Vac Input Range
 Desktop and Wall-Plug versions

Meets “Heavy Industrial” Levels of EN61000
EMC Requirements

Meets EN55011/CISPR11, FCC Part 15.109
Class B Conducted & Radiated Emissions, with
6db margin

Approved to EN/IEC/UL60950-1, 2nd Edition,
Am. 2

E-cap life of >7 years

3 Year Warranty

RoHS Compliant
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications.
Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial
levels of various EN61000-4-x standards for EMC. The TE10A series models also meet Class B conducted and radiated
EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment
and other industrial applications.
Model Selection
Model
Number
TE10A0503F01
TE10A0703F01
TE10A1203F01
TE10A2403F01
TE10A0503N01
TE10A0703N01
TE10A1203N01
TE10A2403N01
TE10A0503Q01
TE10A0703Q01
TE10A1203Q01
TE10A2403Q01
TE10A0503B01
TE10A0703B01
TE10A1203B01
TE10A2403B01
TE10A0503C01
TE10A0703C01
TE10A1203C01
TE10A2403C01
Notes:
Volts
5.0V
7.5V
12.0V
24.0V
5.0V
7.5V
12.0V
24.0V
5.0V
7.5V
12.0V
24.0V
5.0V
7.5V
12.0V
24.0V
5.0V
7.5V
12.0V
24.0V
Output
Current
2.0A
1.3A
1.0A
0.5A
2.0A
1.3A
1.0A
0.5A
2.0A
1.3A
1.0A
0.5A
2.0A
1.3A
1.0A
0.5A
2.0A
1.3A
1.0A
0.5A
Output
Power
10W
10W
12W
12W
10W
10W
12W
12W
10W
10W
12W
12W
10W
10W
12W
12W
10W
10W
12W
12W
Ripple &
Noise¹
50mV pk-pk
75mV pk-pk
120mV pk-pk
240mV pk-pk
50mV pk-pk
75mV pk-pk
120mV pk-pk
240mV pk-pk
50mV pk-pk
75mV pk-pk
120mV pk-pk
240mV pk-pk
50mV pk-pk
75mV pk-pk
120mV pk-pk
240mV pk-pk
50mV pk-pk
75mV pk-pk
120mV pk-pk
240mV pk-pk
Line
Regulation
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Load
Regulation
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Output
Connector
Input
Configuration
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class I Desktop,
IEC60320 C14
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Desktop,
IEC60320 C8
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Desktop,
IEC60320 C18
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Wall-Plug,
Interchangeable Blades
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
(North American Blade
included)²
Class II Wall-Plug, Fixed
North American Blades³
1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors.
2. Order blade kit KT-1027K for other blades (EU. UK, Australia)
3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”.
www.slpower.com
TE10 Rev 1.2 28-MAY-15
PRELIMINARY
1
TE10
10W-12W Single Output External Power
Test & Measurement/Industrial Series
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
Earth Leakage
Current
Efficiency
100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Less than 700mS @115Vac, full load
115Vac: A, 230Vac: A
A max. at 90Vac
Hold-up Time
20mS min., at full Load, 100Vac input
264Vac, cold start: will not exceed 40A
F1, F2: TBDA, 250Vac fuses (line & neutral
lines) provided on all models
No Load Input
Power
<0.1W per DoE Efficiency Level VI
Requirements
Transient
Response
Regulation
Drop Test
Vibration
Dimensions
Weight
www.slpower.com
Short Circuit
Protection
Overvoltage
Protection
Meets US DoE Efficiency Level VI Average
efficiency levels
10 to 12W continuous – See models chart for
specific voltage model ratings.
Output Voltage
Overload Protection
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
Output Power
Ripple and Noise
Overtemperature
Protection
Isolation
Hiccup Mode, auto recovery.
130 to 150% of output voltage, hiccup mode
Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
Operating
Temperature
-20°C to +50°C
Start Up at -40°C, full load, (warmup period before
Temperature
Derating
Derate output power above 40°C to TBD at
50°C
See models chart on pg 1.
Storage Temperature
Altitude
See models chart on pg 1.
1.4m from table top to wooden platform, 6
faces.
130 to 180% of rating, Hiccup Mode
Safety Standards
See models chart on pg 1.
500µs response time for return to within 0.5%
of final value for any 50% load step over the
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
Will shutdown upon an overtemperature
condition, auto-recovery.
Relative Humidity
all parameters are within published specifications).
-40°C to +85°C
Operating: to 5000m.
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
Shock
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
See outline drawings
MTBF
>250,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
E-Cap Life
TBDg
TE10 Rev 1.2 28-MAY-15
>7 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day.
PRELIMINARY
2
TE10
10W-12W Single Output External Power
Test & Measurement/Industrial Series
EMI/EMC Compliance
Conducted Emissions:
EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac
Radiated Emissions:
EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac
Common Mode Noise:
High Frequency (100kHz-20MHz): <40mA pk-pk
Electro-Static Discharge (ESD)
Immunity on Power ports:
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
Radiated RF EM Fields Susceptibility
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
Electrical Fast Transients (EFT) /Bursts:
EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode)
Conducted Disturbances induced by RF
Fields
EN55024/IEC61000-4-5, Level 4, +/-1kV DM, +/-4kV CM, Criteria A
EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur
radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz
Rated Power frequency magnetic fields
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz
Voltage Interruptions, Dips, Sags &
Surges
EN55024/IECEN61000-4-11:
--100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
--30% dip for 500mS, Criteria A
Harmonic Current Emissions
EN55011/EN61000-3-2, Class A
Flicker Test
EN61000-3-3
Mechanical Drawing
IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector
Notes:
www.slpower.com
Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector
1. All dimensions in mm.
2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K.
TE10 Rev 1.2 28-MAY-15
PRELIMINARY
3
TE10
10W-12W Single Output External Power
Test & Measurement/Industrial Series
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below.
The “03” in the standard model number is replaced by the applicable digits below:
Efficiency Level VI Information:
TE10A Series
Data Sheet © 2015 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
TE10 Rev 1.2 28-MAY-15
PRELIMINARY
4