AULT SPECIFICATION PW300 Universal Series INPUT Voltage Line Frequency Current Protection 100-250VAC -10%, +6% 47-63 Hz 1.3A Max. at 100VAC Input Internal primary current fuse, Inrush limiting Overcurrent and short circuit protected In Case IEC320 with Ground Configuration OUTPUT Model PW300KA0012F01 Final 3/31/97 Voltage +5VDC +12VDC -12VDC Min. Current 0A 0A 0A Max. Current Max.Watts Max. Power 5.0A 4.0A 0.5A 25.0 24.0 6.0 50 Watts Combined Line and Load Voltage Regulation Excluding Cord +5VDC: +1% Combined +5,+12 Output of >0.6A +12VDC: +5% -5% Combined +5, +12 Output of >0.6A -12VDC: +6% Combined +5, +12 Output of >0.6A Ripple +5: 50mV p-p Max combined +5, +12 Output >0.6A +12: 100mV p-p Max combined +5, +12 Output >0.6A -12: 100mV p-p Max combined +5, +12 Output >0.6A 0.5mSec for 50% load change typical 20mSec @ 120VAC; 120mSec @ 240VAC Foldback overcurrent protection on all outputs Short circuit protection on all outputs OVP 6.8V Max on +5VDC 3 ft., 5 Conductor, 18 AWG, Ault #12 Connector Other Connectors are also available Transient Response Holdup Time Protection Cord and Connectors ELECTRICAL Topology Dielectric Withstand Safety Spacings Leakage Current Efficiency EMI CE Switching - Fixed Frequency Flyback 3000VAC, 4250VDC Primary - Secondary 1500VAC, 2150VDC Primary - Ground 500VDC, Secondary - Ground 8mm Primary - Secondary Less than 0.75mA at 265VAC 50Hz Up to 75% Complies with EMC Directives CE Compliant SAFETY APPROVALS UL1950, CSA950, TUV/IEC950 ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Altitude Cooling 0° - 50° C with no derating -30° C to +85° C 5% to 95% Non-condensing 0 - 10,000 Feet Convectional non-vented case MECHANICAL Case and Dimensions Case Material Weight WARRANTY LP8 - Desktop 5.87 L x 3.34 W x 2.0 H (in) 149 L x 86 W x 51 H (mm) Black 94V0 Polycarbonate 16 Ounces, 454 grams (excluding cords) 3 Years