PW300 Discontinued Datasheet

AULT SPECIFICATION
PW300 Universal Series
INPUT
Voltage
Line Frequency
Current
Protection
100-250VAC -10%, +6%
47-63 Hz
1.3A Max. at 100VAC Input
Internal primary current fuse, Inrush limiting
Overcurrent and short circuit protected
In Case IEC320 with Ground
Configuration
OUTPUT
Model
PW300KA0012F01
Final 3/31/97
Voltage
+5VDC
+12VDC
-12VDC
Min.
Current
0A
0A
0A
Max. Current
Max.Watts
Max. Power
5.0A
4.0A
0.5A
25.0
24.0
6.0
50 Watts
Combined Line and Load
Voltage Regulation
Excluding Cord
+5VDC: +1% Combined +5,+12 Output of >0.6A
+12VDC: +5% -5% Combined +5, +12 Output of >0.6A
-12VDC: +6% Combined +5, +12 Output of >0.6A
Ripple
+5: 50mV p-p Max combined +5, +12 Output >0.6A
+12: 100mV p-p Max combined +5, +12 Output >0.6A
-12: 100mV p-p Max combined +5, +12 Output >0.6A
0.5mSec for 50% load change typical
20mSec @ 120VAC; 120mSec @ 240VAC
Foldback overcurrent protection on all outputs
Short circuit protection on all outputs
OVP 6.8V Max on +5VDC
3 ft., 5 Conductor, 18 AWG, Ault #12 Connector
Other Connectors are also available
Transient Response
Holdup Time
Protection
Cord and Connectors
ELECTRICAL
Topology
Dielectric Withstand
Safety Spacings
Leakage Current
Efficiency
EMI
CE
Switching - Fixed Frequency Flyback
3000VAC, 4250VDC Primary - Secondary
1500VAC, 2150VDC Primary - Ground
500VDC, Secondary - Ground
8mm Primary - Secondary
Less than 0.75mA at 265VAC 50Hz
Up to 75%
Complies with EMC Directives
CE Compliant
SAFETY APPROVALS
UL1950, CSA950, TUV/IEC950
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Cooling
0° - 50° C with no derating
-30° C to +85° C
5% to 95% Non-condensing
0 - 10,000 Feet
Convectional non-vented case
MECHANICAL
Case and Dimensions
Case Material
Weight
WARRANTY
LP8 - Desktop
5.87 L x 3.34 W x 2.0 H (in)
149 L x 86 W x 51 H (mm)
Black 94V0 Polycarbonate
16 Ounces, 454 grams (excluding cords)
3 Years