AULT SPECIFICATIONS SW201 and SW301 Universal Series INPUT Voltage Line Frequency Current Protection Configuration OUTPUT Model 100-250 VAC - 10%, +6% 47-63 Hz 0.65A Max. at 90 VAC input Internal primary current fuse Inrush limiting In Case IEC320 with Ground SW201KA0012F01 +5VDC +12VDC Min. Current 0A 0A SW301KA0012F01 +5VDC +12VDC -12VDC 0A 0A 0A Voltage Combined Line and Load Voltage Regulation Excluding Cord Ripple Transient Response Holdup Time Protection Cord and Connectors ELECTRICAL Topology Dielectric Withstand Spacing Leakage Current Efficiency EMI CE Max. Current Max. Watts Max. Power 4.0A 1.0A 20.0W 12.0W 22.5 4.0A 1.0A 0.6A 20.0W 12.0W 7.2W 22.5 +5: +1% combined +5, +12 output of >0.6A +12: +5% combined +5, +12 output of 0.6A -12: +6% combined +5, +12 output of >0.6A +5: 50 mV p-p Max., for combined +5, +12 output >0.6A +12: 100 mV p-p Max., for combined +5, +12 output >0.6A -12: 100 mV p-p Max., for combined +5, +12, output.>0.6A 0.5 msec for 50% load change typical 18 msec @ 120VAC; 100 msec @ 240VAC Foldback overcurrent protection on all outputs Short circuit protection on all outputs Optional overvoltage crowbar 6.8V Max. on +5 Optional reverse polarity crowbar on -12 6 ft., 4 or 5 Conductor, 18 AWG, Ault #12 Connector Other Connectors are also available Switching - Variable Frequency Flyback 3000 VAC, 4250 VDC primary-secondary 1500 VAC, 2150 VDC primary-ground 500 VDC secondary-ground 8mm primary-secondary Less than 0.75 mA at 265 VAC 50 Hz Up to 72% Complies with EMC Directives CE Compliant SAFETY APPROVALS UL1950, CSA950, TUV/IEC950 ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Altitude Cooling 0° to 50° C with no derating -30°C to +85° C 5% to 95% non-condensing 0 - 10,000 feet Convectional non-vented case MECHANICAL Case and Dimensions Case Material Weight WARRANTY Final 3/31/97 LP7 - Desktop 5.08 L x 3.05 W x 1.59 H (in) 129 L x 77 W X 40 H (mm) Black 94V0 Polycarbonate 13 ounces, 370 grams (excluding cords) 3 Years