G2A-434

Power Relay
G2A-434
CSM_G2A-434_DS_E_4_1
Fully Sealed Version of G2A that Displays Its
Power in Adverse Environments
• Exhibits stable performance in an adverse atmosphere of
harmful gas, moisture, or powdery dust due to its hermetically
sealed construction.
• All the mechanical components of the Relay have been
annealed to prevent gas generation inside the Relay.
• Economical as compared with a hermetically sealed relay in a
metallic enclosure.
Ordering Information
Contact form
4PDT
Classification
Standard model
Plug-in terminals
G2A-434A(-D)(-N)(-N1)
PCB terminals
G2A-4341P
Note: When placing your order, add the coil voltage rating to the model number as shown below.
Example: G2A-434A-VS 200/220 VAC
Rated coil voltage
Model Number Legend
G2A-@@@@@-@
1
2
3 4
5
6
5. Safety Breaking Mechanism
None: No
Y:
Arc barrier
6. Special Elements
None: Standard
D:
Built-in diode
N:
Built-in operation indicator
N1:
Built-in operation indicator and diode
1. Number of Poles and Contact Form
4:
4PDT
2. Contact Type
3:
Crossbar bifurcated
3. Enclosure Construction
4:
Fully sealed
4. Terminal Shape
A:
Plug-in
1P:
PCB
■ Accessories (Order Separately)
Sockets
Classification
DIN Track-mounting
Socket
Screw terminals
Without Hold-down
Clip
PYF14A(-E)
PYF14A-TU
PYF14T
With Hold-down Clip ---
Back-connecting Socket
Solder terminals
Wire-wrap terminals
PCB terminals
PY14
PY14-3
PY14QN(2)
PY14-0
PY14-02
PY14-Y2
PY14QN(2)-Y2
---
---
Note: See the G2A datasheet for detailed information on Relay Hold-down Clips and Socket Mounting Plates.
1
G2A-434
Specifications
■ Coil Ratings
Rated
voltage
Current
50 Hz
Coil
resistance
60 Hz
Coil inductance (ref.
value)
Armature
OFF
Must
operate
Armature
ON
6 VAC
295 mA
233 mA
8.9 Ω
0.048 H
0.065 H
24 VAC
73 mA
58 mA
136 Ω
0.691 H
1.04 H
100/
110 VAC
17.7/
21.4 mA
14/
16.8 mA
2,200 Ω
12.42/
12.38 H
18/16.4 H
200/
220 VAC
8.9/
10.8 mA
7/8.4 mA
8,800 Ω
42.2/
41.8 H
72/65.5 H
12 VDC
88 mA
136 Ω
0.6 H
1.0 H
24 VDC
45 mA
530 Ω
2.7 H
4.6 H
48 VDC
22 mA
2,200 Ω
11 H
19 H
100 VDC
11.4 mA
8,800 Ω
43 H
73 H
Must
release
Max.
voltage
Power
consumption
% of rated voltage
80 % max.
30 % min.
110 %
10 % min.
Approx.
1.4 VA
Approx.
1.1 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and
±15% for DC coil resistance.
2. The AC coil resistance and coil inductance values are for reference only.
3. Performance characteristic data is measured at a coil temperature of 23°C.
4. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
5. For built-in operation indicator models rated at 6, 12, and 24 VDC, add an LED current of approx. 5 mA to the rated currents.
■ Contact Ratings
Load
Resistive load (cosφ = 1)
Contact mechanism
Crossbar bifurcated
Contact material
Movable:AgAu-clad AgPd
Fixed:AgPd
Rated load
0.3 A at 110 VAC
0.5 A at 24 VDC
Rated carry current
2A
Max. switching voltage
250 VAC, 125 VDC
Max. switching current
AC: 0.7 A
DC: 2 A
Inductive load (cosφ = 0.4) (L/R = 7 ms)
0.2 A at 110 VAC
0.3 A at 24 VDC
AC: 0.5 A
DC: 1 A
2
G2A-434
■ Characteristics
Contact resistance (see note 2)
100 mΩ max.
Operate time (see note 3)
15 ms max.
Release time (see note 3)
15 ms max.
Max. operating frequency
Mechanical: 18,000 operations/hour
Electrical: 1,800 operations/hour (under rated load)
Insulation resistance (see note 4)
100 MΩ min. (at 500 VDC)
Dielectric strength
1,500 VAC, 50/60 Hz for 1 minute between coil and contact and between contacts of different polarities
(700 VAC between contacts of same polarities)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Error rate (level P)
(Reference value)
(see note 5)
1 mA at 100 mVDC
Endurance
Mechanical:
Electrical:
100,000,000 operations min. (at operating frequency of 18,000 operations/hour)
5,000,000 operations min. (under rated load and at operating frequency of
1,800 operations/hour) (see note 6)
Ambient temperature
Operating:–10°C to 40°C (with no icing or condensation)
Ambient humidity
Operating:5% to 85%
Weight
Approx. 39 g
Note: 1. The data shown above are initial values.
2. The contact resistance was measured with 0.1 A at 5 VDC using the voltage drop method.
3. The operate and release times were measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C.
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
strength.
5. This value was measured at a switching frequency of 60 operations per minute.
6. The electrical endurance was measured at an ambient temperature of 23°C.
Engineering Data
Maximum Switching Power
Switching current (A)
DC resistive load
AC resistive load
AC inductive
load (cosφ
= 0.4)
DC inductive load
L/R = 7 ms
Endurance (x10 3 operations)
Endurance
10,000
7,000
5,000
3,000
24-VDC resistive load
300
100
70
50
30
Switching voltage (V)
24-VDC
inductive load
L/R = 7 ms
1,000
700
500
110-VAC resistive load
110-VAC
inductive load
(cosφ = 0.4)
Switching current (A)
3
G2A-434
Ambient Temperature vs.
Must-operate and Must-release
Voltage
Malfunctioning Shock
G2A-434A 100/110 VAC
Number of Relays: 5
G2A-434A DC
Must-operate
voltage
Mustrelease
voltage
Must-operate and reset voltage (%)
Must-operate and reset voltage (%)
G2A-434A AC (60 Hz)
Number of Relays: 5
Not energized
Must-operate
Energized
voltage
Must-release
voltage
Shock direction
Ambient temperature (°C)
Unit: m/s2
Ambient temperature (°C)
Number of samples: 5
Measurement conditions: Impose a shock of
100 m/s2 in the ±X, ±Y, and ±Z directions three
times each with the Relay energized and not
energized to check the shock values that cause
the Relay to malfunction.
H2S Gas Data (Reference)
G2A-434A 24 VDC
Contact resistance
(mΩ)
Max.
Min.
Hours
Measurement:
Sample is left in an atmosphere of H2S gas with concentration of 2 to
5 ppm at 40°+5°/–0°C and at 75% to 80%, then taken out from the
gas atmosphere at fixed time intervals, and left for 30 minutes or
more at room temperature and humidity. The contact resistance values before and after the test are measured.
4
G2A-434
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Dimensional tolerances are ±0.1 mm.
Plug-in Terminal/Solder Terminal Model s
G2A-434A
G2A-434A-D
G2A-434A-N (1)
Terminal Arrangement/Internal
Connections
(Bottom View)
2.6
22.5 max.
G2A-434A
G2A-434A-D
Fourteen, 1.2-dia. holes x 3 elliptic holes
0.5
29.5 max.
1.8
42.5 max.
5.4
(No coil polarity)
Be sure to wire the terminals
with the correct polarity.
G2A-434A-N
6, 12, 24, 50, 100/110,
200/220 VAC
G2A-434A-N1
6, 12, 24 VDC
48, 100 VDC
6, 12, 24 VDC
Operation indicator color
AC model: Red
DC model: Green
48, 100 VDC
Note: DC models have coil polarity. Be sure to wire the terminals with
the correct polarity.
PC Terminal Model
G2A-4341P
Mounting Holes on PCB
(Bottom View)
0.5
1
22.5 max.
2.6
Terminal Arrangement
(Bottom View)
Fourteen, 1.5-dia. holes
5
4.1
0.5
29.5 max.
6.35
7.3
1.8
42.5 max.
4
4.4
4.4
13.2
The coil has no polarity.
5
G2A-434
Safety Precautions
Refer to Safety precautions for All Relays.
DC models with a built-in indicator or built-in diode have coil polarity.
Be sure to wire the terminals with the correct polarity.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2010.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.