S8VK POWER SUPPLIES Reliable and easy operation – worldwide »» The most compact class on the market » »Re s i s t a n t i n to u g h e nv i ro n m e n t s » »E a s y a n d f a s t i n s t a l l a t i o n 2 Compact power supplies… Omron has developed a new and exciting To ensure that we provide the perfect solution family of compact power supplies. With the to match every customer’s need, Omron has same high quality and practical design that launched 4 different families: the cost effective made our previous series safe, reliable, and S8VK-C, the standard with single-phase input easy to install, the new S8VK series is even S8VK-G, the standard with three-phase input tougher, more compact and easier to use. S8VK-T, and the redundancy unit S8VK-R. Omron is a world leader in the development and manufacture of industrial power supplies. We launched our first compact product, the S82K, in 1987 and our S8VS compact series has been an automatic choice with customers since 2002. 3 …that make a world of difference! Three compelling reasons why the S8VK is the right power supply for you: Resistant in tough environments Easy and fast installation The most compact class on the market Omron is confident that the quality The S8VK series not only offers you Designed with space saving in mind, the of the S8VK will exceed your high greater flexibility when designing your S8VK series is our most compact power- expectations. Its robust design machine, it also saves you time and supply range ever and the most compact and construction withstand harsh reduces costs thanks to the minimal class on today’s market. environments and provide stable wiring requirements and easy one- operation over a wide operating handed mounting provided by the temperature range. Because of high enhanced DIN-rail mounting clip. MTBF figures, your S8VK will keep running in stable condition for a long term. 4 Resistant in tough environments Wherever the S8VK is installed within the range of the S8VK derating curve, it will give the same reliable performance for the duration of its service life. The wide operating temperature range of between -40°C to 70°C (S8VK-G/T/R) guarantees stable operation in any environment where other power supplies may be found lacking. But its robust design advantages don't end there because the S8VK also offers high resistance to the vibration transmitted by machinery in close proximity, this is due to the vibration-resistant DIN-rail mounting clip. The image is for illustration purposes only. 5 Easy and fast installation Making your life easier Simply click onto a standard DIN rail using one hand to mount in a flash. Effortless and time saving! In addition, the S8VK features a double set of DC output terminals (three for the negative terminal), which means you also spend less time and effort on wiring. Long-life guaranteed Designed to international safety standards for global markets, the S8VK even has approvals for marine applications (S8VK-G/T/R) and carries an across-the-board, warranty on all models no matter which country your machine is exported to! Because of high MTBF figures, your S8VK will keep running in stable condition for a long term. 6 The most compact class on the market Designed with downsizing in mind Omron knows that size is important for machine designers, which is why we have applied our developed technology using thermal simulation for the design of the S8VK. This enabled the S8VK compact size body. This gives a high power density in a compact package. And the S8VK has an even sleeker exterior than any previous models. Thermal view Component view 7 The S8VK series line up The perfect match for your needs To ensure that we have the perfect solution to match every •The redundancy unit S8VK-R designed for specific applications and special demands. need, Omron offers three different families: •The cost effective S8VK-C line with uncompromising quality. •The standard S8VK-G and three phase S8VK-T, our “install & forget” option, offering longer lifetime, higher protection and more features. Featuring INPUT S8VK-C Power Supply S8VK-G S8VK-T Redundancy Unit S8VK-R Single Phase AC 100-240VAC - - Three Phase AC - 380-480VAC - DC 90-350VDC 450-600VDC* * Excluding 960 W Operation Temperature -25 °C to 60 °C -40 °C to 70 °C Safety standards UL 508 (Listing), UL 60950-1 (Recognition) cUL No.107.1, cUR No.60950-1 EN 50178, EN 60950-1 5-30VDC,10-60VDC -40 °C to 70 °C <120W> UL 508(Listing),EN 50178 <240/480/960W> UL 508 (Listing) UL 60950-1(Recognition) cUR No.60950-1 EN 50178, EN 60950-1 UL 508(Listing), UL 60950-1(Recognition) cUL No.107.1, cUR No.60950-1 EN 50178, EN 60950-1 CE Yes Yes Yes Yes RoHS Yes Yes Yes Yes EN61204-3 EN55011 ClassB EN61000-6-3 EN55011 ClassB Marine applications - Lloyd's Register EMI EN61204-3 EN55011 ClassA EN61204-3 EN55011 ClassB Lloyd's Register Harmonic current emissions EN 61000-3-2 (240W/480W) EN 61000-3-2 EN 61000-3-2 - Parallel Operation No Yes Yes - Additional features No Power boost 120% Redundancy OK LED Voltage Balance LED S8VK Series line-up Ordering information S8VK-G series Type Power ratings Input voltage Output voltage Output current Boost current Size (W × H × D) [mm] Order code Power supply Single phase 15 W 100 to 240 VAC, 90 to 350 VDC 5V 3A 3.6 A 22.5 × 90 × 90 S8VK-G01505 12 V 1.2 A 1.44 A 24 V 0.65 A 0.78 A 5V 5A 6A 12 V 2.5 A 3A 24 V 1.3 A 1.56 A 12 V 4.5 A 5.4 A 24 V 2.5 A 3A 120 W 24 V 5A 6A 40 × 125 × 112.2 S8VK-G12024 240 W 24 V 10 A 12 A 60 × 125 × 140 S8VK-G24024 48 V 5A 6A 24 V 20 A 24 A 48 V 10 A 12 A 30 W 60 W 480 W S8VK-G01512 S8VK-G01524 32 × 90 × 90 S8VK-G03005 S8VK-G03012 S8VK-G03024 32 × 90 × 110 S8VK-G06012 S8VK-G06024 S8VK-G24048 95 × 125 × 140 S8VK-G48024 S8VK-G48048 S8VK-C series Type Power ratings Input voltage Output voltage Output current Boost current Size (W × H × D) [mm] Order code Power supply Single phase 60 W 100 to 240 VAC, 90 to 350 VDC 24 V 2.5 A - 32 × 90 × 110 S8VK-C06024 24 V 5A - 40 × 125 × 112.2 S8VK-C12024 240 W 24 V 10 A - 60 × 125 × 140 S8VK-C24024 480 W 24 V 20 A - 95 × 125 × 140 S8VK-C48024 120 W S8VK-T series Type Power ratings Input voltage Output voltage Output current Boost current Size (W × H × D) [mm] Order code Power supply Three phase 120 W 380 to 480 VAC, 450 to 600 VDC 24 V 5A 6A 40 × 125 × 112.2 S8VK-T12024 24 V 10 A 12 A 60 × 125 × 140 S8VK-T24024 24 V 20 A 24 A 95 × 125 × 140 S8VK-T48024 40 A 48 A 135 × 125 × 170 S8VK-T96024 240 W 480 W 960 W 380 to 480 VAC 24 V Current ratings Input voltage Output current Size (W × H × D) [mm] Order code 5 to 30 VDC 10 A 32 × 90 × 110 S8VK-R10 10 to 60 VDC 20 A 40 × 125 × 112.2 S8VK-R20 S8VK-R series Type Redundancy Module 10 A 20 A 8 S8VK-G Series line-up S8VK-G Nomenclature 15-W Models 30-W / 60-W / 120-W / 240-W Models S8VK-G015 S8VK-G030 /S8VK-G060 S8VK-G480 3 3 4 5 4 5 4 5 1 480-W Models /S8VK-G12024/S8VK-G240 1 2 2 1 Note: The S8VK-G06024 is shown above. No. Name Function 1 Input terminals (L), (N) Connect the input lines to these terminals. *1 2 Protective Earth terminal (PE) Connect the ground line to this terminal. *2 3 DC Output terminals (-V), (+V) Connect the load lines to these terminals. 4 Output indicator (DC ON: Green) Lights while a direct current (DC) output is ON. 5 Output voltage adjuster (V.ADJ) Use to adjust the voltage. 2 3 *1. The fuse is located on the (L) side. It is not user-replaceable. For a DC input, connect the positive voltage to the L terminal. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. S8VK-G Dimensions S8VK-G015 S8VK-G12024 (120 W) (15 W) 114 6.35 (1) 5 3.6 dia. (Bit #1) 90 75.4 3.6 dia. (Bit #1) Rail Stopper 5.0 8 22.5 S8VK-G030 90 86 Rail Stopper S8VK-G240 (1) S8VK-G060 7.62 32 1 4.7 (Sliding: 7.5 max.) 122.2 (240 W) 141.8 86 90 3.6 dia. (Bit #1) Rail Stopper 40 6.35 90 3.6 dia. (Bit #1) 75.4 125 3.5 4.7 (Sliding: 10 max.) (30 W) 5 104.6 34.7 125 104.6 34.7 3.5 4.7 (Sliding: 10 max.) Rail Stopper (60 W) 60 S8VK-G480 4.7 (Sliding: 7.5 max.) 1 151 (480 W) 5 140.8 90 75.4 125 52.3 Rail Stopper 32 4.7 (Sliding: 10 max.) 1 3.5 111 1 6.35 95 Rail Stopper 4.7 (Sliding: 7.5 max.) 151 9 S8VK-C Series line-up S8VK-C Nomenclature 60-W/120-W/240-W Models 480-W Model S8VK-C06024/S8VK-C12024/S8VK-C24024 S8VK-C48024 3 4 5 4 5 2 1 1 3 2 Note: The S8VK-C06024 is shown above. No. Name Function 1 Input terminals (L), (N) Connect the input lines to these terminals. *1 2 Protective Earth terminal (PE) Connect the ground line to this terminal. *2 3 DC Output terminals (−V), (+V) Connect the load lines to these terminals. 4 Output indicator (DC ON: Green) Lights while a direct current (DC) output is ON. 5 Output voltage adjuster (V.ADJ) Use to adjust the voltage. *1. The fuse is located on the (L) side. It is not user-replaceable. For a DC input, connect the positive voltage to the L terminal. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. S8VK-C Dimensions (Unit: mm) S8VK-C24024 (240 W) S8VK-C06024 (60 W) (1) 5 3.6 dia. (Bit #1) 110 106 6.35 5.0 dia. (Bit #2) Rail Stopper 60 S8VK-C12024 (120 W) 104.6 6.35 (10) 4.7 (Sliding: 7.5 max.) S8VK-C48024 (480 W) (1) 5.0 dia. (Bit #2) 6.35 34.7 3.5 4.7 (Sliding: 10 max.) 7.62 32 (4) 125 104.6 3.6 dia. (Bit #1) Rail Stopper (1) 34.9 90 75.4 5.0 dia. (Bit #2) 150 145.6 140 122.2 117.8 112.2 (1) (4) (4) 140 125 34.7 125 150 145.6 34.7 52.3 5.0 dia. (Bit #2) Rail Stopper 10 6.35 40 4.7 (Sliding: 7.5 max.) (10) 5.0 dia. (Bit #2) 6.35 6.35 95 Rail Stopper 5.0 dia. (Bit #2) 4.7 (Sliding: 7.5 max.) (10) S8VK-T Series line-up S8VK-T Nomenclature 120-W/240-W Models 480-W Model S8VK-T12024/S8VK-T24024 960-W Model S8VK-T48024 S8VK-T96024 3 1 4 4 4 5 5 5 1 2 1 3 2 3 2 Note: The S8VK-T12024 is shown above. 6 No. Name Function 1 Input terminals (L1), (L2), (L3) Connect the input lines to these terminals. *1 2 Protective Earth terminal (PE) Connect the ground line to this terminal. *2 3 DC Output terminals (−V), (+V) Connect the load lines to these terminals. 4 Output indicator (DC ON: Green) Lights while a direct current (DC) output is ON. 5 Output voltage adjuster (V.ADJ) Use to adjust the voltage. 6 Operation Switch *3*4 To operate in parallel or 2-phase input, set the switch to the "B" side. (960 W model only). *1. For wiring, refer to page 13 of the S8VK-T Datasheet (Cat. No. T061). *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. *3. For parallel operation, refer to page 15 of the S8VK-T Datasheet (Cat. No. T061). *4. For 2-phase input, refer to page 15 of the S8VK-T Datasheet (Cat. No. T061). S8VK-T Dimensions (Unit: mm) S8VK-T48024 (480 W) S8VK-T12024 (120 W) 40 6.35 104.6 122.2 (1) 150 117.8 112.2 (4) 145.6 140 95 125 125 52.3 6.35 Rail Stopper 19.8 6.35 6.35 6.35 19.8 (26.8) (10) 4.7 (Sliding: 7.5 max.) 30 S8VK-T24024 (240 W) 60 25 (1) 4.7 (Sliding: 7.5 max.) Rail Stopper (1) 180 150 145.6 175.6 170 135 (4) 140 19.8 47.9 4.7 (Sliding: 7.5 max.) (4) 125 6.35 Rail Stopper (10) S8VK-T96024 (960 W) 125 104.6 (4) 10.16 (10) Rail Stopper 10.16 (1) 4.7 (Sliding: 7.5 max.) 19.8 (10) (36.7) 41.78 32.95 11 S8VK-R Series line-up S8VK-R Nomenclature 10 A Model 20 A Model S8VK-R10 S8VK-R20 1 2 3 2 1 3 5 5 6 6 7 7 4 4 No. Name Function 1 Input terminal 1 Connect the input 1 lines to these terminals. 2 Input terminal 2 Connect the input 2 lines to these terminals. 3 terminal 4 Output terminal Connect the load lines to these terminals. 5 Status indicator (redundancy OK: Green) Lighting: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ. 6 Status indicator (voltage balance: Green) Lighting: Voltage difference between Vin1 and Vin2 is less than 50 mV typ. 7 Status contact (redundancy OK: photo switch) Photo switch contact ON: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ. This is not a ground terminal. There are no functional or safety concerns even if you do not connect it to ground. S8VK-R Dimensions (Unit: mm) S8VK-R20 S8VK-R10 5.0 dia. (Bit #2) 6.35 3.6 dia. (Bit #1) 75.4 8.5 117.8 (4) 112.2 110 (1) 5 (1) 106 34.9 90 104.6 34.7 125 20.5 5 5 5.7 7.62 32 Rail Stopper 3.5 4.7 (Sliding: 10 max.) 6.35 8.2 3.6 dia. (Bit #1) 40 Rail Stopper 4.7 (Sliding: 7.5 max.) (10) 5.0 dia. (Bit #2) Note: Refer to the S8VK-G Datasheet (Cat. No. T056) for details. Refer to the S8VK-C Datasheet (Cat. No. T058) for details. Refer to the S8VK-R Datasheet (Cat. No. T059) for details. Refer to the S8VK-T Datasheet (Cat. No. T061) for details. OMRON Corporation Tokyo, JAPAN Industrial Automation Company Authorized Distributor: Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2013-2014 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan CSM_2_3_0314 Cat. No. T057-E1-05 0314(0213)