Safety Controller G9SP - OMRON Industrial Automation

Safety Controller G9SP
Software-based standalone controller family
» Reconfigure to every need
» Flexible range suits any system
» Simple set-up and clear diagnosis
2
Modular safety control
The Omron G9SP is a new range of configurable
safety controllers suited to the packaging, food,
automotive components, injection moulding and
printing industries. Because it isn’t hardwired into
your system, you benefit from a new flexibility, easily
reconfiguring the unit when new safety features are
added to your set-up. Three different models are
available, with a range of I/O lines, so you can
choose the most suitable for your system. Each one
is compatible with the Omron configuration tool,
recognised by industry as one of the most
simple and accessible on the market.
Omron G9SP: Global safety levels, lower TCO
• Configurable unit makes it ideal for building multiple
stand-alone systems with the same specifications, or
reconfiguring an existing set-up
• Handles function blocks for non-contact switches,
single-beam sensors and safety mat inputs
• Faster and easier integration compared to hardwired
systems
• Single simple GUI for configuration, simulation,
testing and validation
• Greatly reduced set-up time
• EN ISO 13849-1 ready (PLe/Safety category 4)
3
Safety as standard
What’s more, our global network of offices, worldwide
product availability, and unrivalled aftersales support
give Omron customers a clear advantage. Help
and expert advice on installation, operation and
maintenance are always available, wherever you are.
Stand-alone Controller
Safety Network Controller
G9SP
NE1A
Hard-wired
Because operator safety is paramount in every system,
we have invested our expertise in developing a full
range of fully-compatible products. Our comprehensive
selection of safety products help ensure maximum
up-time, minimum interruption, and a fully-protected
workplace.
Programmable
Omron has a complete range of safety solutions, from
E-stop, door and limit switches to safety sensors
and safety mats. The Omron G9SP is part of the most
extensive offering in the industry, enabling Omron
to supply a full variety of products to a range of
applications worldwide.
G9SX
G9SA/SB
Small
< Application size >
Large
4
Configurable, flexible, simple:
the keys to safety
Every safety system relies on correct set up and the
most suitable equipment. The Omron G9SP makes
this easier than ever to do. The features of this product
range give your new or existing set-up a range of
benefits:
Configurations matrix
 Safety controller G9SP
 Expansion I/O Units
 Memory cassette
 Ethernet option board
 RS-232C option board
 Compact non-contact
door switch
 Safety mats
 CJ1/PLC
 Relays with forcibly
guided contacts
 AC Servomotor/Drives
G5 series
Configurator
Programmable terminal
NB series










5
G9SP CPU Unit
Expansion I/O Unit
Designing
Reusing
Simulating
Packaging
Option Board
Ethernet
I/O
Serial
PLC
Reconfigurable
Flexible
Simple
With the Omron Configuration Tool, all
aspects of input and output to the unit
can be defined, simulated, tested and
validated with an easy-to-use graphical
user interface. If you are building
with a make-once/use-many profile,
configurations can be copied and applied
to all systems. If you are reconfiguring an
existing set-up, it’s just as simple. When
user needs change, it can be adapted
quickly and easily to meet those needs.
Unlike hard-wired safety relays, the Omron
G9SP can be reconfigured to multiple
purposes. Because it is a solid-state,
software-driven unit, all aspects of its
operation can be reconfigured, with direct
connection to non-contact switches or
safety mats. Three I/O sizes are available:
20/8, 10/16 and 10/4. Covering the
full range of typical small-to-mid sized
systems, the Omron G9SP also comes with
optional expansion units for standard I/O
signals (12/8 and 0/32). Function blocks
up to 128pcs complete this fully flexible
range, so you can always be sure of a
needs-match solution.
Above all, the Omron G9SP range is
supplied with simplicity. With the Omron
Configuration Tool, you can quickly
define all inputs, outputs, scope, testing,
simulation, validation and operation of
your system. On-screen text and icondriven menus guide the user quickly
through all aspects of set-up. Clear alerts
and system status give any operator
an instant overview at every stage of
operation.
6
Reconfiguration and reusability
for real TCO savings
Modern production and automotive parts production
lines must be flexible to cater to changing customer
needs. This often means being able to change machine
set-up at short notice, for custom jobs or additional
requirements. With the Omron G9SP, it couldn’t be
easier. Function blocks can be redesigned and replaced
using the simple GUI, swiftly incorporating any
application changes or additions.
Even the most complex controls can be configured
easily. Clear programming guidance is provided for
new users, and modification and maintenance have
been simplified too. Settings can be saved to Memory
Cassette for off-line diagnostics, and any programming
changes can be restored instantly into the Omron G9SP
from the same memory cassette.
Safety in automotive component manufacture
A change in machine operation can easily be covered by
reconfiguring the application program. Certified function
blocks for all kinds of safety functions are already on board
and ready to use.
7
G9SP CPU Unit
Expansion I/O Unit
Old
New
Option Board
Ethernet
I/O
Serial
PLC
Easy maintenance without tools
Transparent diagnosis
Simple unit replacement
Connection to PC/PLC via Ethernet makes the Omron G9SP
fully accessible. Diagnosis,troubleshooting and program
modification is simple, thanks to the USB programming
interface and removable memory cassette.
Because the Omron G9SP is a software-based controller,
replacement is effortless. All settings, parameters and
function blocks can be saved on a PC or stored on the Memory
Cassette for easy transfer from one unit to another.
8
Increased flexibility means
decreased TCO
Modern packaging machines must be flexible to exactly
match changing customer needs. With the Omron G9SP,
application flexibility is built in. Choose from three
standalone safety controller CPU types, then combine
with any communication interface or 2 additional
standard I/O signals. All G9SP units support direct
connections of all kinds of safety sensors, including
safety mats, non-contact door monitoring systems and
single-beam sensors.
The Omron G9SP can be monitored and configured
from a standard control console via Ethernet, serial
board or standard I/O lines. For multiple applications
of a single configuration, the Omron G9SP memory
cassette usage. Which means that systems designers
now only need to program the unit once, and use the
memory cassette to install settings into each identical
system.
Presence detection
Door monitoring
Omron has a variety of pressure safety mats in a range of
sizes. Useful in any area where personnel may be at risk, mats
instantly alert the Omron G9SP, which can immediately sound
an alert or close down any dangerous machinery.
Direct connection of all Omron non-contact door monitoring
solutions is supported by the G9SP family for maximum
flexibility and minimum effort in setup and maintenance.
9
Safety inputs
Standard inputs
+
Safety outputs
Standard outputs
Copy configuration without tools
Standard I/O
Memory cassette for fast, simple ease of use
The G9SP family offers a range of easily-connected standard
I/O units. This instant interface between safety and standard
controls can be used to configure standard control signals into
the complete safety configuration. Monitoring is simple too,
via standard I/O units or Ethernet/serial boards for advanced
monitoring.
Designing safety systems is no longer the complex task it used
to be. As well as a clear and simple programming interface,
the Omron G9SP offers the advantage of memory cassette.
Programs can be quickly modified and restored, with no
additional effort.
10
Configuration made simple
When designing or updating a safety system,
configuration used to be one of the most timeconsuming tasks. Not with the Omron G9SP.
Thanks to a clear and simple user interface, designing
your system is easier than ever. Step-by-step
instructions guide you through every aspect of design.
A simulation tool allows you to test and correct settings
before your system goes live. Then, thanks to userdefined function blocks, you can re-use any aspect of
your design in future systems.
11
Easy configuration
User-defined function blocks
All safety functions are ready to use in the G9SP. Certified
function blocks can be easily selected in the graphical user
interface and customized to fit your application.
Approved configuration elements such as a tested door
monitoring solution can be easily stored as a user defined
function block and re-used in future projects. This minimises
the time it takes to create a new system configuration.
Simulation
Knowledge-building
All functions can be tested and simulated in the Configuration
Tool, so there’s no unnecessary additional workload for the
engineer. In addition, on-line diagnosis reduces debug time
to a minimum during implementation in the machine control
system.
Existing configurations are the basis for new projects. The
G9SP Configuration Tool supports re-use of existing and
proven know-how in safety control, as well as user-defined
function blocks. Which means no more repetition of effort,
instead a growing library of safety solutions.
Safety Controller
G9SP
Easy programming for complex safety
control
• Stand-alone Safety Controller for small and mid-sized
machinery
• Three types of CPU with different I/O size to suit the
application
• Four types of Expansion I/O Units for hard-wired diagnosis or
standard signals
• Clear diagnosis and monitoring via Ethernet or Serial
connection
• Various kinds of safety devices directly connectable like noncontact switches and safety mats
• Easy design, verification, standardization and reusage of
safety control by unique programming software
• ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to "Safety Precautions" on page 26.
Example of the system configuration
Expansion I/O Unit
G9SP Series
Peripheral Tool
G9SP Configurator
PC
WS02-G9SP@@@
USB Cable
CP1W-20EDT/EDT1
G9SP-N@@@
CP1W-32ET/ET1
Memory Cassette
CP1W-ME05M
Expandable up to 2 Units
When the Units are distantly-positioned
such as one above the other layout
G9SP Series
I/O Connecting Cable
RS-232C
Option Board
Ethernet
Option Board
CP1W-CIF01
CP1W-CIF41 (Ver. 2.0 or later)
or
CP1W-CN811
Expansion I/O Unit
RS-232C
RS-232C or
Ethernet Communication
Programmable terminal
12
Standard PLC
G9SP
Ordering Information
G9SP Series
Name
Number of I/O
Safety inputs Test outputs
Safety Controller
Safety outputs
Standard outputs
4
10
4
Solid-state outputs: 4
10
6
Solid-state outputs: 16
-
20
6
Solid-state outputs: 8
-
Unit
version
Model
G9SP-N10S
Ver.2.0
G9SP-N10D
G9SP-N20S
Expansion I/O Unit (for standard machine control)
Name
Number of I/O
Type
Sinking type
Expansion I/O Unit
Sourcing type
Inputs
Outputs
12
Solid-state outputs: 8
-
Solid-state outputs: 32
Sinking type
Sourcing type
Model
CP1W-20EDT
CP1W-20EDT1
CP1W-32ET
CP1W-32ET1
Note: CP1W-CN811 I/O Connecting Cable is available.
Refer to the Datasheet of CP1H Programmable Controller (Cat. No. P080-E1) for details.
I/O Connecting Cable
Name
Specifications
Model
I/O Connecting Cable
80 cm
(for the distantly-positioned units connection)
CP1W-CN811
Note: An I/O Connecting Cable (approx. 6 cm) for alongside setting is included in the Expansion I/O Unit package.
Option Unit
Name
Model
RS-232C Option Board
CP1W-CIF01
Ethernet Option Board (Unit Ver. 2.0 or later)
CP1W-CIF41
Memory Cassette
CP1W-ME05M
Note: Refer to the Datasheet of CP1H Programmable Controller (Cat. No. P080-E1) for details.
Configurator
Name
Media
Applicable OS
Setup Disk (CD-ROM: 1 license)
Windows XP
(Service Pack 3 or higher,
64-bit edition not supported)
Windows Vista
(Service Pack 2 or later)
Windows 7
Setup Disk (CD-ROM: 10 licenses)
G9SP Configurator
Setup Disk (CD-ROM: 50 licenses)
Setup Disk (CD-ROM: Site license)
Model
WS02-G9SP01-V@
WS02-G9SP10-V@
WS02-G9SP50-V@
WS02-G9SPXX-V@
Note: 1. Administrator rights are required for installation.
2. Operation is possible on the 64-bit editions of Windows Vista and Windows 7.
Version Information
The combinations that can be used of the unit versions of the G9SP series and the version of Configurator.
G9SP series
G9SP Configurator
Unit version Ver.1.@
Ver.1.@
Ver.2.00
Unit version Ver.2.0
---
Ver.2.00
13
G9SP
Function Support by Unit Version of G9SP
Serial communication speed
Unit Version
Item
Ver.1.@
Communications protocol
Ver.2.0
No-protocol
Communication speed
9,600 bps
Transmission disutance
max.15 m
9,600 bps
115,200 bps *
max.15 m
(With a baud rate of 115,200 bps: max.3 m)
Data length
8 bits
Parity
Even
Stop bits
1 bit
* The baud rate can be set to 115,200 bps with turning on the DIP swith pin 3.
Connectivity with OMRON safety input devices
Unit Version
Item
Single-beam Safety Sensor
E3ZS, E3FS
Ver.1.@
Ver.2.0
max.1 unit
G9SP-N10D/N20S: max.6 units
G9SP-N10S
: max.4 units
Non-contact Door Switche
D40A, D40Z
G9SP-N10D/N20S: max.30 units
G9SP-N10S
: max.15 units
Safety Mat
UM
max.12 units
Programmable Terminal NB series
Programmable Terminals
Product name
Specifications
Model
3.5 inch, TFT LCD, Color, 320 × 240 dots
NB3Q-TW00B
NB3Q
3.5 inch, TFT LCD, Color, 320 × 240 dots,
USB Host, Ethernet
NB3Q-TW01B
5.6 inch, TFT LCD, Color, 320 × 234 dots
NB5Q-TW00B
NB5Q
5.6 inch, TFT LCD, Color, 320 × 234 dots,
USB Host, Ethernet
NB5Q-TW01B
7 inch, TFT LCD, Color, 800 × 480 dots
NB7W-TW00B
NB7W
7 inch, TFT LCD, Color, 800 × 480 dots,
USB Host, Ethernet
NB7W-TW01B
10.1 inch, TFT LCD, Color, 800 × 480 dots,
USB Host, Ethernet
NB10W-TW01B
NB10W
Software
Product name
Support Software for NB Series
NB-Designer *
Specifications
Supported Operating Systems:
®
Windows 8, Windows 7, Windows Vista , Windows XP (SP3 or higher).
Note: Note: Except for Windows XP 64-bit version
Download from Omron's regional websites.
* NB-Designer version 1.32 or later can be used with G9SP.
For detail, refer to the NB Series catalog (Cat. No. V412-E1).
14
G9SP
Specifications
(Refer to Instruction Manual and Users Manual for details.)
G9SP Series
General Specifications
Power supply voltage
24 VDC (20.4 to 26.4 VDC -15% +10%)
Current consumption *
G9SP-N10S: 400 mA (V1: 300 mA, V2: 100 mA)
G9SP-N10D: 500 mA (V1: 300 mA, V2: 200 mA)
G9SP-N20S: 500 mA (V1: 400 mA, V2: 100 mA)
Isolation class
Class III (SELV)
Overvoltage category
II
Noise immunity
Conforms to IEC61131-2
Vibration resistance
5 to 8.4 Hz: 3.5 mm, 8.4 to 150 Hz: 9.8 m/s2
Shock resistance
147 m/s2: 11 ms
Mounting
DIN track mounting (IEC60715 TH35-7.5/TH35-15) or M4 screws
Ambient operating temperature
0 to +55°C
Ambient operating humidity
10% to 90% (with no condensation)
Ambient storage temperature
-20°C to +75°C
Atmosphere
No corrosive gas
Operating altitude
2,000 m max.
Pollution degree
Pollution degree 2
Degree of protection
IP20 except terminal blocks
Terminal screws
M3 self-rising screws
* Not including the current consumption of external devices.
Item
Model
G9SP-N10S
G9SP-N10D
G9SP-N20S
Safety inputs
10
10
20
Safety outputs
4
16
8
Test outputs
4
6
6
Standard outputs
4
-
-
290 g max.
440 g max.
430 g max.
Weight
Safety Input Specifications
Safety Output Specifications
Input type
Sinking inputs (PNP)
Input current
6 mA
ON voltage
11 VDC min. (between each input terminal and
G1)
OFF voltage
5 VDC max. (between each input terminal and
G1)
OFF current
1 mA max.
Test Output Specifications
Output type
Sourcing outputs (PNP)
Rated Output
Current
G9SP-N10S
T0, T1
T2
T3
T0-2 total
G9SP-N10D
T0, T1, T2
T3
T4, T5
Total of T0-2 and T4-5
G9SP-N20S
T0, T1, T2
T3
T4, T5
Total of T0-2 and T4-5
: 60 mA max.
: 30 mA max. *1
: 300 mA max. *2
: 60 mA max.
: 60 mA max.
: 300 mA max. *2
: 30 mA max. *1
: 60 mA max.
: 100 mA max.
: 300 mA max. *2
: 30 mA max. *1
: 120 mA max.
ON residual
voltage
1.8 V max. (between each output terminal and
V1)
Leakage current
0.1 mA max.
Output type
Sourcing outputs (PNP)
Rated output
current
0.8 A max./output
1.6 A max./4 outputs (G9SP-N10S/-N20S) *1
1.2 A max./4 outputs (G9SP-N10D) *2
ON residual
voltage
1.2 V max. (between each output terminal and
V2)
OFF residual
voltage
2 V max.
Leakage current
0.1 mA max.
*1. Total current for So0 to So3 and So4 to So7
*2. Total current for So0 to So3, So4 to So7, So8 to So11 and So12 to So15
Note: When a safety output is set as a pulse output, make sure that
the connected devices do not malfunction due to the OFF pulse
(pulse width: 640 μs).
Standard Output Specifications (G9SP-N10S)
Output type
Sourcing outputs (PNP)
ON residual
voltage
1.5 V max. (between each output terminal and
V2)
Rated output
current
100 mA max.
*1. Connection to OMRON D40A/D40Z Non-contact Door Switch is possible.
*2. With the Muting Lamp Output (open circuit detection)
15
G9SP
Configurator
System Requirements
The following system is required to operate the G9SP Configurator. Make sure your system provides the following conditions and has the
necessary components.
Item
Description
CD-ROM or DVDROM drive
One or more
Supported operating systems
Windows XP (Service Pack 3 or higher, except for 64-bit edition)
Windows Vista (Service Pack 2 or higher)
Windows 7
Note: 1. Administrator rights are required for installation.
2. Operation is possible on the 64-bit editions of Windows Vista and Windows 7.
CPU
Computer with a processor that is recommended by Microsoft Corporation.
RAM
Memory capacity that is recommended by Microsoft Corporation
Required hard disk space
200 MB min.
Display
High-luminance display of SVGA (800 × 600) min.
With 256 colors min.
Connection port to Controller
USB port
Certified Standards
Certifying body
Standard
TÜV
Rheinland
EN ISO 13849-1
EN ISO 13849-2
IEC 61508 parts 1-7
EN 62061
IEC 61131-2
EN ISO 13850
EN 60204-1
EN 61000-6-2
EN 61000-6-4
NFPA 79
ANSI RIA R15.06
ANSI B11.19
ANSI/UL 1998
UL
UL508
CSA22.2 No.142
KOSHA
S Mark *
* The G9SP-series Controller (version 1.1 or later) and the Expansion I/O Units have been certified for the KOSHA S Mark.
16
G9SP
Expansion I/O Unit
Input Specifications (CP1W-20EDT/20EDT1)
Item
Specifications
Input voltage
24 VDC, +10%, -15%
Input impedance
4.7 kΩ
Input current
5 mA TYP
ON voltage
14.4 VDC min.
OFF voltage
5.0 VDC max.
ON delay
1 ms max. *
OFF delay
1 ms max. *
Input display LED
IN
Circuit configuration
4.7 k
IN
Internal circuits
750
COM
* ON/OFF delay represents the hardware delay time.
Output Specifications (Transistor outputs: sinking/sourcing type)
Specifications
Item
CP1W-20EDT/EDT1
CP1W-32ET/32ET1
24 VDC
+10%, -5%
0.3 A/output
4.5 to 30 VDC
0.3 A/output
0.9 A/common
1.8 A/unit
0.9 A/common
7.2 A/unit
Leakage current
0.1 mA max.
0.1 mA max.
Residual voltage
1.5 V max.
1.5 V max.
ON delay
0.1 ms max.
0.1 ms max.
OFF delay
1 ms max.
24 VDC, +10%, -5%, when 5 to 300 mA
1 ms max.
24 VDC, +10%, -5%, when 5 to 300 mA
Maximum number of outputs for
simultaneous ON
8 outputs (100% load)
24 outputs (75% load)
Fuse *2
1/common
Maximum switching capacity *1
Sinking type (CP1W-20EDT, CP1W-32ET)
Sourcing type (CP1W-20EDT1, CP1W-32ET1)
Output display LED
Output display LED
OUT
L
COM (+)
Circuit configuration
L
Internal
circuits
OUT
24 VDC/
4.5 to 30
VDC
Internal
circuits
24 VDC/
4.5 to 30
VDC
OUT
L
COM(-)
L
OUT
*1. A maximum of 0.9 A per common can be switched at an ambient temperature of 50°C.
(A)
0.9
Common total current
0.8
50 55 (°C)
0
Ambient temperature
*2. User cannot replace fuses. Replace the unit if a fuse blows due to short circuit, etc.
17
G9SP
Option Unit
RS-232C Option Board (CP1W-CIF01)
Communication Specifications
Item
Specifications
Connection method
D-SUB 9P (female)
Maximum transmission distance
With a baud rate of 9,600 bps: 15m
With a baud rate of 115,200 bps: 3m
Communication protocol
No-protocol
Maximum data length
Refer to the Users Manual for details.
Communication settings
Baud rate 9,600 or 115,200 bps (unit version 2.0 or later)
Ethernet Option Board (CP1W-CIF41 unit ver. 2.0 or later)
Ethernet Communication Specifications
Item
Specifications
Name
CP Series Ethernet Option Board
Model
CP1W-CIF41
Type
100 BASE-TX (applicable as a 10 BASE-T)
Media access method CSMA/CD
Modulation method
Baseband
Transmission path
type
Star form
Baud rate
Transmission
specifications
Transmission media
100 Mbps (100 BASE-TX)
Unshielded twisted-pair (UDP) cable
Categories: 5, 5e
Shielded twisted-pair (STP) cable
Categories: 100 Ω at 5, 5e
Transmission distance 100 m (distance between hub and node)
Number of cascadeconnectable units
18
10 Mbps (10 BASE-T)
Internal transmission speed between G9SP and Ethernet Option Board is of 115.2 kbps.
No limit when a switching hub is used.
Weight
23 g max.
Dimensions
36.4 (W) x 36.4 (H) x 28.2 (D) mm
Unshielded twisted-pair (UDP) cable
Categories: 3, 4, 5, 5e
Shielded twisted-pair (STP) cable
Categories: 100 Ω at 3, 4, 5, 5e
G9SP
Functions
(Refer to the Instructions Reference Manual (Cat. No. Z923-E1) for details.)
Function Blocks
Logic Functions
Function Block
Name
Notation on Function
List
Icon
Details
NOT
NOT
Outputs the logical complement of the input condition.
AND
AND
Outputs the logical AND of the input conditions.
OR
OR
Outputs the logical OR of the input conditions.
NAND
NAND
Outputs the logical NAND of the input conditions.
NOR
NOR
Outputs the logical NOR of the input conditions.
Exclusive OR
EXOR
Outputs the exclusive OR of the input conditions.
Exclusive NOR
EXNOR
Outputs the exclusive NOR of the input conditions.
RS-FF
(Reset
Set Flip-Flop)
RS-FF
When the input signal turns ON, RS-FF holds the ON status in the
function block and continuously connects to the output.
Comparator
Comparator
Compares the input signals to the set value and turns ON the output
if they match.
Comparator 2
Comparator2
Compares the input signals to the set value and outputs the
comparison result.
Timer/Counter Functions
Function Block
Name
Notation on Function
List
Icon
Details
Off-Delay Timer
Off-Delay Timer
Operates an OFF-delay timer.
On-Delay Timer
On-Delay Timer
Operates an ON-delay timer.
Pulse Generator
Pulse Generator
Cyclically outputs ON/OFF pulses on the Output Enable while the
input signal is ON.
Counter
Counter
Counts the number of input signals and turns ON the output when
the count reaches the specified number.
Up-Down Counter
Up-Down
Counter
Increments the counter on the leading edge of an up count input
and decrements the counter on the leading edge of a down count
input.
Serial-Parallel
Converter
Serial-Parallel
Converter
Counts the number of input signals and outputs the count value.
19
G9SP
Safety Device Function Blocks
Function Block
Name
Notation on Function
List
Icon
Details
External Device
Monitoring
EDM
Evaluates the input signal and external device status and sends a
safety output to the external device. This function block is used to
detect fused contacts or external wiring problems (disconnected
lines) for safety relays, contactors, and other safety devices.
Enable Switch
Monitoring
Enable Switch
Monitors the status of an Enable Switch device.
Emergency Stop
Switch Monitoring
E-Stop
Monitors the status of an Emergency Stop Switch.
Light Curtain
Monitoring
Light Curtain
Monitoring
Monitors the input signal from a Safety Light Curtain.
Muting
Muting
Temporarily disables the input signals for a Light Curtain when the
muting signal is detected.
Safety Gate
Monitoring
Safety Gate Monitoring
Monitors the status of a safety door (Safety-door Switch or Safety
Limit Switch). This function block can be used to set function tests
for Safety Category 2.
Two Hand Controller
Two Hand Controller
Monitors the status of a Two-hand Switch.
User Mode Switch
Monitoring
User Mode Switch
Monitors the operating mode switch for a user system or device.
Redundant Input
Monitoring
Redundant Input
Monitors for discrepancies in two input signals.
Single Beam Safety
Sensor
Single Beam
Safety Sensor
Monitors the input signal of an OMRON E3ZS/E3FS Single-beam
Safety Sensor.
Non-Contact Door
Switch Monitoring
Non-Contact
Door Switch
Monitors an OMRON D40A/D40Z Non-contact Door Switch.
Safety Mat Monitoring Safety Mat
Monitors an OMRON UM Safety Mat.
Reset and Restart Function Blocks
Function Block
Name
Notation on Function
List
Icon
Details
Reset
Reset
Outputs ON if the reset signal is correctly input while the input
condition is ON. This function block can be used to prevent
equipment from starting automatically.
Restart
Restart
Performs the same operation as a Reset function block. The icon is
different.
Connector Function Blocks
Function Block
Name
20
Notation on Function
List
Icon
Details
Multi Connector
Multi Connector
Outputs the status of the input signals.
Routing
Routing
Distributes an input signal to multiple signals.
G9SP
Wiring
Terminal Arrangement
G9SP-N10S
Top
(17 pin)
Terminals
V1 G1 Si1 Si3 Si5 Si7 Si9 T1 T3
NC Si0 Si2 Si4 Si6 Si8 T0 T2
Bottom
NC So0 So2 O0 O2 NC NC
(14 pin) V2 G2 So1 So3 O1 O3 NC
G9SP-N10D
Top
(24 pin)
V1 G1 Si1 Si3 Si5 Si7 Si9 NC NC T1 T3 T5
NC Si0 Si2 Si4 Si6 Si8 NC NC T0 T2 T4 NC
Function
V1/G1
Power supply terminals for Internal/Input circuits
(24 VDC)
V2/G2
Power supply terminals for output circuits (24 VDC)
NC
Not used (Do not connect.)
Si0 - Si19
Safety input terminals
T0 - T5
Test output terminals
So0 - So15
Safety output terminals
O0 - O3
Standard output terminals
Bottom
NC So0 So2 So4 So6 So8 So10 So12 So14
(19 pin) V2 G2 So1 So3 So5 So7 So9 So11 So13 So15
G9SP-N20S
Top
(24 pin)
V1 G1 Si1 Si3 Si5 Si7 Si9 Si11 Si13 Si15 Si17 Si19
NC Si0 Si2 Si4 Si6 Si8 Si10 Si12 Si14 Si16 Si18 NC
Bottom
NC So0 So2 So4 So6 NC T0 T2 T4
(19 pin) V2 G2 So1 So3 So5 So7 NC T1 T3 T5
Internal Circuits and Wiring Example
24 VDC
V1
USB
G1
D+
Si0
D-
Safety
input
circuit
Test
output
circuit
Internal
circuits
Si19
T0
T5
V2
G2
Safety
output
circuit
Standard
output
circuit
So0
L
So7
L
O0
L
O3
L
I/O Wiring Example: Emergency Stop (Dual Channel) with Manual Reset
Estop
Reset
KM1
KM1-NC
KM2
V1
G1
Si0
Si1
So0
So1
KM1
KM2
Si2
Si3
KM2-NC
G9SP
V2
24 VDC
G2
T0
T1
T2
T3
M
21
G9SP
Application Templates
Emergency Stop Pushbutton Application
PL/Safety Category
PLe/4 equivalent
Model
Emergency stop pushbutton
A165E/A22E
Stop category
Reset
0
Manual
Application Overview
The power supply to motor M is turned OFF when emergency stop switch S1 is pressed.
Wiring Example
E1 and E2:
24-VDC power supplies
S1:
Emergency stop switch
S2:
Reset switch
KM1 and KM2: Contactors
M:
Motor
Note: Refer to page 20 for the terminal arrangement.
Timing Chart
Safety I/O Terminal Settings
Input Terminals
Discrepancy error
Reset ON
E-STOP pushed
E-STOP released
Discrepancy
error released
EDM error released
E-STOP S1
11-12
E-STOP S1
21-22
Reset S2
More than
350 ms
More than
350 ms
More than
350 ms
Output Terminals
KM1
KM2
EDM
feedback
EDM error
Program
Precautions for Safe Use
• Perform a function test every six months to
detect contact welding failures on contactors.
• It is the user's responsibility to make sure that
the entire system complies with standards.
• For safety reasons, two electrical switching
elements and two relays or contactors are
always necessary to detect electrical faults and
mechanical faults.
22
G9SP
Safety Light Curtain Application
PL/Safety Category
Model
• Emergency stop pushbutton
• Safety light curtain
• Safety Limit Switch
PLe/4 equivalent
A165E/A22E
F3SJ-E@@@@P25
D4N/D4F
Stop category
Reset
0
Manual
Application Overview
The power supply to the motor is turned OFF when light is intercepted in the safety light curtain and the safety
limit switch turns OFF simultaneously.
The output also goes OFF when emergency switch S1 is pressed.
S1
S2
S4
S3
Wiring Example
E1 and E2:
24-VDC power supplies
S1:
Emergency stop switch
S2:
Safety light curtain
S3:
Safety limit Switch
S4:
Reset switch
KM1 and KM2: Contactors
M:
Motor
Note: Refer to page 20 for the terminal arrangement.
Timing Chart
Safety I/O Terminal Settings
Input Terminals
S3 detects the
robot arm.
S2 detects a
human body.
Reset ON
Hazard
approaches.
E-Stop pressed
E-Stop released
S2 detects a human body and S3
detects the robot arm.
Hazard (e.g., robot arm) is
interrupting light to S3 and stopped.
Light curtain
Light curtain
Limit Switch
Limit Switch
E-Stop S1
Safety light curtain
S2
Safety Limit Switch
S3
Reset S4
KM1, KM2
More than
350 ms
More than
350 ms
Output Terminals
EDM feedback
Idle → Run
Program
Precautions for Safe Use
• Perform a function test every six months to
detect contact welding failures on contactors.
• It is the user's responsibility to make sure that
the entire system complies with standards.
• For safety reasons, two electrical switching
elements and two relays or contactors are
always necessary to detect electrical faults and
mechanical faults.
23
G9SP
D40A Non-Contact Switch Application
PL/Safety Category
PLe/4 equivalent
Model
• Emergency stop pushbutton
• Non-Contact Door Switch
A165E/A22E
D40Z
Stop category
Reset
0
Manual
Application Overview
The power supply to motor M is turned OFF when emergency stop switch S1 is pressed.
The power supply to motor M is turned OFF by opening safety door S2.
Wiring Example
E1 and E2:
S1:
S2:
S3:
KM1and KM2:
M:
24-VDC power supplies
Emergency stop pushbutton
D40A Non-contact Switch
Reset switch
Contactors
Motor
Note: Refer to page 20 for the terminal arrangement.
Timing Chart
Gate close → Open
Reset ON
E-Stop pressed
E-Stop released
Gate open → Close
Safety I/O Terminal Settings
Input Terminals
E-Stop S1
Non-contact
Switch S2
More than 350 ms
More than 350 ms
More than 350 ms
Reset switch S3
Output Terminals
KM1 and KM2
EDM feedback
Idle → Run
Program
Precautions for Safe Use
• Perform a function test every six months to
detect contact welding failures on contactors.
• It is the user's responsibility to make sure that
the entire system complies with standards.
• For safety reasons, two electrical switching
elements and two relays or contactors are
always necessary to detect electrical faults
and mechanical faults.
24
G9SP
Dimensions
(Unit: mm)
Safety Controller
G9SP-N10S
85
81
86
76
110 100
8
90
2-4.5 dia.
Safety Controller
G9SP-N10D
G9SP-N20S
110 100
85
81
130
120
8
90
4-4.5 dia.
25
G9SP
Safety Precautions
Meanings of Signal Words
WARNING
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death. Additionally there may be
significant property damage.
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or there may be property
damage.
Meaning of Alert Symbols
Indicates prohibited actions.
Indicates mandatory actions.
WARNING
Electric shock may occur. Do not touch any terminals
while power is being supplied.
Serious injury may possibly occur due to loss of
required safety functions. Do not use the G9SP-series
Controller's test outputs or standard outputs as
safety outputs.
Serious injury may possibly occur due to loss of
required safety functions. Do not use the G9SP-series
Controller's network data as safety data.
Serious injury may possibly occur due to loss of
required safety functions. Do not use indicators on the
G9SP-series Controller for safety operations.
Serious injury may possibly occur due to breakdown
of safety outputs or test outputs. Do not connect
loads beyond the rated values to the safety outputs
and test outputs.
Serious injury may possibly occur due to loss of required
safety functions. Wire the G9SP-series Controller properly
so that the 24 VDC line does NOT touch the outputs
accidentally or unintentionally.
Serious injury may possibly occur due to loss of
required safety functions. Ground the 0V line of the
power supply for external output devices so that the
devices do NOT turn ON when the safety output line
or the test output line is grounded.
26
Serious injury may possibly occur due to loss of
required safety functions. Perform user testing and
confirm that all of the G9SP-series Controller’s
configuration data and operation is correct before
starting system operation.
Serious injury may possibly occur due to loss of
required safety functions. When replacing a G9SPseries Controller, confirm the model of the Controller
is correct and configure the replacement Controller
suitably and confirm that it operates correctly.
Serious injury may possibly occur due to loss of
required safety functions. When the configuration
data is restored by using a Memory Cassette, a test
must be performed to confirm that the safety devices
function correctly.
Outputs may operate, possibly resulting in serious
injury. Take sufficient safety measures before forcesetting or force-resetting variables in the program.
Serious injury may possibly occur due to loss of
required safety functions. Use devices and parts
related to safety functions according to legal
regulations in the applicable country. Use certified
items compliant with safety standards corresponding to the
intended application.
Precautions for Safe Use
Handle with Care
Do not drop the G9SP-series Controller or subject it to excessive
vibration or mechanical shock. The G9SP-series Controller may be
damaged and may not function properly.
Installation and Storage Environment
Do not use or store the G9SP-series Controller in any of the following
locations:
• Locations subject to direct sunlight
• Locations subject to temperatures or humidity outside the range
specified in the specifications
• Locations subject to condensation as the result of severe changes in temperature
• Locations subject to corrosive or flammable gases
• Locations subject to dust (especially iron dust) or salts
• Locations subject to water, oil, or chemicals
• Locations subject to shock or vibration
Take appropriate and sufficient measures when installing systems in
the following locations. Inappropriate and insufficient measures may
result in malfunction.
• Locations subject to static electricity or other forms of noise
• Locations subject to strong electromagnetic fields
• Locations subject to possible exposure to radioactivity
• Locations close to power supplies
This is a class A product designed for use in industrial environments.
In residential areas it may cause radio interference, in which case the
user may be required to take adequate measures to reduce
interference.
• Use the G9SP-series Controller within an enclosure with IP54
protection or higher according to IEC/EN 60529.
G9SP
• Use DIN Track (TH35-7.5/TH35-15 according to IEC 60715) or M4
screws with a tightening torque of 1.2 N·m (10.5 lb·in) to install the
G9SP-series Controller into the control panel.
• Mount the G9SP-series Controller to the DIN Track using PFP-M
End Plates (not included with the G9SP-series Controller) to
prevent it from falling off the DIN Track because of vibration.
Correctly mount all Units to DIN Track.
• Install the G9SP-series Controller in the vertical direction shown
below to ensure adequate cooling.
• Do not ground the 24-V side of the power supply to the G9SPseries Controller. If you do so, an unwanted current flow shown in
the following diagram may occur when you connect a computer or
other peripheral device.
Peripheral device
G9SP
DC power circuit
24 V
USB cable
0V
0V
0V
FG
GND
• Do not connect the Expansion I/O Units over the specified number.
Power Supply Selection
• Space must be provided around the G9SP-series Controller, at
least 20 mm from its side surfaces and at least 50 mm from its top
and bottom surfaces, for ventilation and wiring.
• Be sure to lock all locking mechanisms, such as those on I/O
terminal blocks and connectors, before attempting to use the
Controller.
Turn OFF the power supply before performing any of the following.
• Connecting or disconnecting Expansion I/O Units, Option Boards,
or any other Units
• Assembling the Controller
• Connecting cables or wiring
• Connecting or removing terminal blocks
Installation and Wiring
• Use the following to wire external I/O devices to the G9SP-series
Controller.
Solid wire
0.32 to 0.82 mm2 AWG22 to AWG18
0.32 to 0.5 mm2 AWG22 to AWG20 *
Stranded wire
0.5 to 1.3 mm2 AWG20 to AWG16
0.5 to 0.82 mm2 AWG20 to AWG18 *
Use a DC power supply satisfying the following requirements.
• The secondary circuit of the DC power supply must be isolated
from the primary circuit by double insulation or reinforced insulation.
• The isolated power supply with a current limited to 8 A.
• The output hold time must be 20 ms or longer.
• The DC power supply must be an SELV power supply that satisfies the requirements of IEC/EN 60950-1 and EN 50178.
Periodic Inspections and Maintenance
• Disconnect the G9SP-series Controller from the power supply
before replacing the Controller. Devices connected to the G9SPseries Controller may operate unexpectedly.
• Do not disassemble, repair, or modify the G9SP-series Controller.
Doing so may lead to loss of safety functions.
Disposal
• Be cautious not to injure yourself when dismantling the G9SPseries Controller.
* When wiring two wires to one terminal. Use two wires of the same type and
thickness.
• Tighten the terminal block screws to a torque of 0.5 N·m.
• Disconnect the G9SP-series Controller from the power supply
before starting wiring. Devices connected to the G9SP-series
Controller may operate unexpectedly.
• Properly apply the specified voltage to the G9SP-series Controller
inputs. Applying an inappropriate DC voltage or any AC voltage will
cause the G9SP-series Controller to fail.
• Be sure to separate the communications cables and I/O cables
from high-voltage/high-current lines.
• Be cautious not to get your fingers caught when attaching
connectors to the plugs on the G9SP-series Controller.
• Incorrect wiring may lead to loss of safety functions. Wire
conductors correctly and verify the operation of the G9SP-series
Controller before using the system in which the G9SP-series
Controller is incorporated.
• Lock the connectors on Option Units or Expansion I/O Unit before
using the Units.
• After wiring is completed, be sure to remove the label for wire clip
entry prevention from the G9SP-series Controller to enable heat to
escape for proper cooling.
27
MEMO
28
MEMO
29
MEMO
30
READ AND UNDERSTAND THIS CATALOG
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions
or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
Copyright and Copy Permission
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON SCIENTIFIC TECHNOLOGIES INC.
6550 Dumbarton Circle, Fremont
CA 94555-3605 U.S.A.
Tel: (1) 510-608-3400/Fax: (1) 510-744-1442
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2010 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_9_2_0614
Printed in Japan
Cat. No. F090-E1-01
(0619)