Ultra-long Sensing-distance Proximity Sensor TL-L CSM_TL-L_DS_E_4_2 Detection Distance of 100 mm for Both Ferrous and Non-ferrous Substances. • Ultra long-distance detection of 100 mm for both ferrous and non-ferrous substances. • Models also available for use under water. Be sure to read Safety Precautions on page 4. Ordering Information Appearance Cylindrical (flat surface installation) Sensing distance 100 mm Output configuration Current output Model TL-L100-7 1M Note: The TL-L100-10 is also available for use under water (JIS0920: Withstand pressure of 0.39 MPa). 1 TL-L Ratings and Specifications Output specifications Current output Item TL-L100-7 Sensing distance 100 mm ±10% Set distance 0 to 80 mm Differential travel 15% max. of sensing distance Detectable object Ferrous metal and non-ferrous metal Standard sensing object Iron, 200 × 200 × 1 mm Response time 100 ms max. Power supply voltage (operating voltage range) 10 to 30 VDC including 10% ripple (p-p) Current consumption 40 mA DC max. Control output 200 mA DC max. (residual voltage: 1 V max.) Indicators Operation indicator (red) Operation mode (with sensing object approaching) NO; For details, refer to the timing charts under I/O Circuit Diagrams on page 3. Protection circuits Reverse polarity protection, Surge suppressor Ambient temperature range Operating/Storage: −25 to 55°C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±30% max. of sensing distance at 20°C in the temperature range of −10 to 40°C Voltage influence ±5% max. of sensing distance at rated voltage in rated voltage ±10% range Insulation resistance 5 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 200 m/s2 10 times each in X, Y, and Z directions Degree of protection IP66 (IEC) Connection method Pre-wired Models (Standard cable length: 1m) Weight (packed state) Approx. 1.5 kg Materials Case: Aluminum die-cast, Sensing surface: Epoxy resin Accessories Instruction manual Engineering Data (Reference Value) TL-L100-7 TL-L100-7 120 Operate Reset 100 Distance X (mm) Influence of Sensing Object Size and Material Distance X (mm) Sensing Area 100 Sensing object t = 1 mm Aluminum Iron 80 Y d× d X 60 t = 1 mm X 50 40 20 −100 −80 −60 −40 −20 0 20 40 TL-L100 Sensing Head 60 80 Distance Y (mm) 0 100 200 300 Side length of sensing object: d (mm) 2 TL-L I/O Circuit Diagrams Output configuration Model Timing chart Output circuit Brown Sensing object Current output NO Load (between brown and black leads) Output voltage (between black and blue leads) Operation indicator (red) Load None Operate Reset TL-L100-7 +V Present Proximity Sensor main circuit 4.7 kΩ 2.2 Ω Black *1 Output *2 Tr High Low Blue 0V ON OFF *1. Load current: 200 mA max. *2. When a transistor is connected. Connections Connection to the S3D2 Sensor Controller TL-L100-7 Blue: 0 V Black: Output Brown: 12 VDC The signal input switch on the S3D2 can be used to set reverse operation. Note: 1. Refer to S3D2 for details. S3D2 3 TL-L Safety Precautions Refer to Warranty and Limitations of Liability. Precautions for Correct Use WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Do not use this product under ambient conditions that exceed the ratings. ● Design Influence of Surrounding Metal Separate the Sensor from surrounding metal as shown below. Influence of Surrounding Metal A Item A B B Dimension (mm) 250 Mutual Interference When mounting more than one Sensor face-to-face or side-by-side, separate them as shown below. A Mutual Interference Item A B B Dimension (mm) 300 (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. TL-L100-7 Four, 6.5-dia. mounting holes 105 max. 106 45 Four, M6 or 6.5-dia. holes 88 13 Mounting Hole Dimensions 98 88 88 106 (127) 9 * 15 88 Conduit screws C15 JIS C 8305 6 dia. * 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.85 mm), Standard length: 1 m 4 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved.