■ External Dimensions (Unit: mm) Tolerance class IT16 applies to the dimensions unless otherwise specified. ZR-RX70 ZR-RX45 Data Logger 232 2 ZR-RX Series 32 48 120 24.6 122 3.5 232 75 5 ZR-RX70 Mounting Screw Holes 2-M4 Depth 6 ZR-RX45 Mounting Screw Holes 2-M4 Depth 6 Easy data recording with all the capacity you need. 4 GB Internal Memory 69 185 Best-In-Class 23.5 ZR-RX25 91.6 162 16.1 67 102 15 16.5 2-M4 L5 Insert Screw 2 40 194 All channels isolated This document provides information mainly for selecting suitable models. Please read the document User's Manual carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit OMRON ELECTRONICS LLC Carl-Benz-Str. 4, D-71154 Nufringen, Germany IL 60173-5302 U.S.A. Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, Alexandra Technopark, 200 Yin Cheng Zhong Road, Singapore 119967 PuDong New Area, Shanghai, 200120, China Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 One Commerce Drive Schaumburg, © OMRON Corporation 2010-2013 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. E410-E1-03 0413 (0311) (TA) Multi-input Budget prices Anyone-Anytime-Anyplace ZR-RX45 ZR-RX25 Improved performance and operability for multiple recording needs From the manufacturing floor to the research facility, meeting every need at prices so affordable that every employee can have one. 4 GB Flash Memory Long-Term Data Capture Best-In-Class High Data Reliability 4 GB Flash Memory Makes long-term capture possible even in workplaces where a USB flash drive cannot be brought in for security reasons. All Channels Isolated Multi Function Input Each channel is supplied with its own isolated circuit eliminating inter-channel noise interference. Simultaneous measurement of temperature, humidity, voltage and other factors can be performed. Ring Memory Capture Delta-Sigma A/D Converter This function overwrites captured data so that only recent data is saved at all times. A new delta-sigma A/D conversion system boosts anti-noise performance. Allll Mo Mod M od del de els ls All Models All Channels Isolated High-speed, wide-range voltage measurement model Expandability Expandable up to 200 channels (ZR-RX45) Multi-function input Voltage Temperature Temperature Humidity (Thermo- (Resistance couples) thermometer) ZR-RX70A-: High speed Versatile Expandability Pulse Logic Maximum channels Highspeed sampling 8 CH 10 µ S Standard 20 CH, Max. 200 CH 10 ms 10 CH 10 ms Max. ±500 V Wide range 4 GB internal flash memory 200-channel expandable temperature measurement model ZR-RX45A-: 4GB Flash memory Channel expansion Windows 7 -compatible Max. ±50 V 4 GB internal flash memory Easy-to-use and compact 10-channel model ZR-RX25A-: Max. ±50 V 4GB Flash memory Windows 7-compatible Models compatible with power supply and voltage specifications for each country, as well as conforming to Chinese RoHS are also available. For details, please consult your dealer. 1 Anyone-Anytime-Anyplace ZR-RX45 ZR-RX25 Improved performance and operability for multiple recording needs From the manufacturing floor to the research facility, meeting every need at prices so affordable that every employee can have one. 4 GB Flash Memory Long-Term Data Capture Best-In-Class High Data Reliability 4 GB Flash Memory Makes long-term capture possible even in workplaces where a USB flash drive cannot be brought in for security reasons. Versatile Expandability All Channels Isolated Multi Function Input Each channel is supplied with its own isolated circuit eliminating inter-channel noise interference. Simultaneous measurement of temperature, humidity, voltage and other factors can be performed. Ring Memory Capture Delta-Sigma A/D Converter This function overwrites captured data so that only recent data is saved at all times. A new delta-sigma A/D conversion system boosts anti-noise performance. Expandability Expandable up to 200 channels (ZR-RX45) Calibration services (changed option) Based on our traceability system, we calibrate using gauges that conform to international standards. See our website for additional details. For more information on calibration services, please consult your OMRON sales representatives. Improvements Allll Mo Mode M od del de els ls All Models All Channels Isolated High-speed, wide-range voltage measurement model Multi-function input Voltage (Thermo- (Resistance couples) thermometer) ZR-RX70A-: High speed Temperature Temperature Humidity Pulse Wider range of features Logic Maximum channels Highspeed sampling Memory Isolation A/D Resolution Ring conversion capacity memory system capture 8 CH 10 µ S 256 MB All channels isolated Sequential comparison Standard 20 CH, Max. 200 CH 10 ms 4 GB All channels isolated 10 CH 10 ms 4 GB All channels isolated Max. ±500 V Wide range PC compatibility LCD LAN monitor connection USB cable USB flash drive Compliant Model CEE CCC PSE 16-bit 5.7-inch (QVGA) -E -CHRO Deltasigma 16-bit 5.7-inch (VGA) -E -CHRO Deltasigma 16-bit 4.3-inch (WQVGA) -E -CHRO 4 GB internal flash memory 200-channel expandable temperature measurement model ZR-RX45A-: 4GB Flash memory Channel expansion Windows 7 -compatible Max. ±50 V 4 GB internal flash memory Easy-to-use and compact 10-channel model ZR-RX25A-: Max. ±50 V 4GB Flash memory Windows 7-compatible Blank after the last hyphen Models compatible with power supply and voltage specifications for each country, as well as conforming to Chinese RoHS are also available. For details, please consult your dealer. 1 2 High-speed, wide-range voltage measurement model Simultaneous sampling with external devices ZR-RX70 ±20 mV to ±500 V Wider range of features Thermocouples Temperature (K, J, E, T, R, S, 8 CH Logic PC compatibility Max. recording time All channels 10 µs isolated B, N, W) Humidity Humidity Sensor (optional ZR-XRH1 required) Pulse The analog X-Y recorder function of the product enables users to view correlations between different pieces of data. The product can also be used as a 4-pen recorder. Digital data captured with this function can be used for reports and other post-measurement work. Data capture can be timed in response to external device. Capture necessary data only. Multi-function input Voltage X-Y Recorder Function 256 MB 5.7 inch internal memory (QVGA) 16 bit Easy-tonavigate menus USB flash drive 2-hour battery USB (High speed) FTP server Web server 100BASE-TX Smart operability with cursor key Useful Trigger and Timer Functions Intuitive operation using a set of cursor keys allows users to view enlarged and reduced images of high-speed waveforms. A 5.7-inch large-screen color LCD (QVGA) enables easy observation of waveforms and measurements even in a dark place. Different combinations of the trigger and timer functions They enable users to eliminate superfluous data and capture the data truly necessary for each situation. Easy-to-see big screen 5.7 inch color LCD TIME/DIV key for enlarging or reducing the time axis Timer Setting resolution Off, Date/Time, Daily Cycle, Hourly Cycle Off, Level Value, External Input, Scheduled Time Stop source setting Off, Level Value, External Input, Scheduled Time Trigger settings Pre-trigger 0% to 100% Only when data is stored in internal RAM Repeat capture Time axis Enlarge Setting example On, Off Measurement of abnormal signals while a certain device is at work NTP client Timer Setting 4 channels in addition to the analog 8 channels (optional ZR-XRL1) Timer mode Start source setting External sampling Daily Cycle Start setting: 09 hrs 00 sec Stop setting: 18 hrs 00 sec Timer mode 10 ms/DIV to 1 min/DIV Trigger settings (Rpm/Count /Inst.) Easy control with cursor keys Time axis Reduce Start source setting Stop source setting Repeat capture Start Key On Level CH1 (3V rising) Level CH1 (2V falling) On Finishing data capturing in priority to timer setting Start trigger 3 V Highest speed and widest input range in its class Stop trigger 2 V 0:00 6:00 12:00 18:00 Timer period Meeting Versatile Requirements 6:00 12:00 Trigger activation points 18:00 0:00 Data capturing PC Compatibility Isolated multi-function input on all channels M3 screw terminals for thermocouple connection Each channel is supplied with its own isolated circuit preventing inter-channel noise interference. Multi-function input enables simultaneous logging of voltage, temperature, humidity (optional), pulse, and logic. A wide variety of inputs can be logged. Pulse selectable from “Rpm,” “Count,” or “Inst.” mode for each channel Each analog input terminal features hybrid BNC terminal / screw terminal specifications. Use either one for voltage input connection. BNC terminals for voltage input Full Array of Features Use in combination with logic input and clamp meter for simultaneous measurement for equipment power supply voltage/current of equipment and sequence control of each component. Super-wide Voltage Input Range Sequence: Logic Current : Clamp meter Thermocouples Ultra high-speed sampling High-speed sampling at speeds up to 10 µs is possible. Thus it is suitable for applications such as drop tests and oscillation tests that require high-speed sampling. Data for lengthy applications, such as endurance tests and environmental tests, can be continuously logged to the flash memory (at a sampling interval of 1 ms or over). 왎 Potential recording time (with 8 analog channels) 10 µs Voltage Internal RAM AC power supply Temperature: Thermocouples Wide input range from ±20 mV to ±500 V. It allows the measurement of 100 to 240 VAC power supply waveforms. Versatile PC linkup via LAN, USB, etc. 3 ways to link to a PC are available through a USB flash drive, a USB connection, or a LAN connection. No initial setup is required. Supports all kinds of data applications. BNC / screw hybrid input terminal Internal flash memory 10 s 100 µs approx. 1 min 40 s 500 µs approx. 8 min 20 s 1 ms approx. 16 min 40 s 10 ms approx. 2h 40 s 1s 100 ms approx. approx. 1 day 11 days 3h 13 h approx. 11 h approx. approx. 4 days 46 days approx. 22 h approx. approx. 9 days 93 days — — — approx. 1h — — — approx. 2h USB flash drive∗ (Example: 512 MB) ∗ Please use a USB flash drive without security function. 3 0:00 Remote control / Monitoring function You can remote control the logger from the web browser installed in your PC by connecting the logger with an IP address to the PC through a LAN network. Files stored on the unit (or on the USB flash drive) can be copied to your PC via the web browser as well. Extract data even while logging is in progress USB flash drive LAN cable USB cable Logger display and buttons are completely replicated on the web browser! With the pre-installed FTP server function, data stored on the logger can be transferred to your PC even while logging is in progress. FTP transfer LAN cable Logging in progress Automatic clock-time correction Clock-time of the unit is automatically corrected by the NTP client function. Real-time data gathering in a PC The special software enables real-time data saving in a PC. The logger can be connected to a PC via USB or LAN connection. Captured data can be simultaneously saved on the logger and on a PC, or on the PC only. PC viewer function Special software allows you to display captured data easily in waveform format. Search, printout, and CSV conversion can also be performed. USB cable ∗ Simply start up the software and select a file. For multi-channel measurement and advanced waveform display, we recommend special PC software (Wave Inspire RX). (See p. 8) You can also save and convert logging data directly to Excel format. 4 High-speed, wide-range voltage measurement model Simultaneous sampling with external devices ZR-RX70 ±20 mV to ±500 V Wider range of features Thermocouples Temperature (K, J, E, T, R, S, 8 CH Logic PC compatibility Max. recording time All channels 10 µs isolated B, N, W) Humidity Humidity Sensor (optional ZR-XRH1 required) Pulse The analog X-Y recorder function of the product enables users to view correlations between different pieces of data. The product can also be used as a 4-pen recorder. Digital data captured with this function can be used for reports and other post-measurement work. Data capture can be timed in response to external device. Capture necessary data only. Multi-function input Voltage X-Y Recorder Function 256 MB 5.7 inch internal memory (QVGA) 16 bit Easy-tonavigate menus USB flash drive 2-hour battery USB (High speed) FTP server Web server 100BASE-TX Smart operability with cursor key Useful Trigger and Timer Functions Intuitive operation using a set of cursor keys allows users to view enlarged and reduced images of high-speed waveforms. A 5.7-inch large-screen color LCD (QVGA) enables easy observation of waveforms and measurements even in a dark place. Different combinations of the trigger and timer functions They enable users to eliminate superfluous data and capture the data truly necessary for each situation. Easy-to-see big screen 5.7 inch color LCD TIME/DIV key for enlarging or reducing the time axis Timer Setting resolution Off, Date/Time, Daily Cycle, Hourly Cycle Off, Level Value, External Input, Scheduled Time Stop source setting Off, Level Value, External Input, Scheduled Time Trigger settings Pre-trigger 0% to 100% Only when data is stored in internal RAM Repeat capture Time axis Enlarge Setting example On, Off Measurement of abnormal signals while a certain device is at work NTP client Timer Setting 4 channels in addition to the analog 8 channels (optional ZR-XRL1) Timer mode Start source setting External sampling Daily Cycle Start setting: 09 hrs 00 sec Stop setting: 18 hrs 00 sec Timer mode 10 ms/DIV to 1 min/DIV Trigger settings (Rpm/Count /Inst.) Easy control with cursor keys Time axis Reduce Start source setting Stop source setting Repeat capture Start Key On Level CH1 (3V rising) Level CH1 (2V falling) On Finishing data capturing in priority to timer setting Start trigger 3 V Highest speed and widest input range in its class Stop trigger 2 V 0:00 6:00 12:00 18:00 Timer period Meeting Versatile Requirements 6:00 12:00 Trigger activation points 18:00 0:00 Data capturing PC Compatibility Isolated multi-function input on all channels M3 screw terminals for thermocouple connection Each channel is supplied with its own isolated circuit preventing inter-channel noise interference. Multi-function input enables simultaneous logging of voltage, temperature, humidity (optional), pulse, and logic. A wide variety of inputs can be logged. Pulse selectable from “Rpm,” “Count,” or “Inst.” mode for each channel Each analog input terminal features hybrid BNC terminal / screw terminal specifications. Use either one for voltage input connection. BNC terminals for voltage input Full Array of Features Use in combination with logic input and clamp meter for simultaneous measurement for equipment power supply voltage/current of equipment and sequence control of each component. Super-wide Voltage Input Range Sequence: Logic Current : Clamp meter Thermocouples Ultra high-speed sampling High-speed sampling at speeds up to 10 µs is possible. Thus it is suitable for applications such as drop tests and oscillation tests that require high-speed sampling. Data for lengthy applications, such as endurance tests and environmental tests, can be continuously logged to the flash memory (at a sampling interval of 1 ms or over). 왎 Potential recording time (with 8 analog channels) 10 µs Voltage Internal RAM AC power supply Temperature: Thermocouples Wide input range from ±20 mV to ±500 V. It allows the measurement of 100 to 240 VAC power supply waveforms. Versatile PC linkup via LAN, USB, etc. 3 ways to link to a PC are available through a USB flash drive, a USB connection, or a LAN connection. No initial setup is required. Supports all kinds of data applications. BNC / screw hybrid input terminal Internal flash memory 10 s 100 µs approx. 1 min 40 s 500 µs approx. 8 min 20 s 1 ms approx. 16 min 40 s 10 ms approx. 2h 40 s 1s 100 ms approx. approx. 1 day 11 days 3h 13 h approx. 11 h approx. approx. 4 days 46 days approx. 22 h approx. approx. 9 days 93 days — — — approx. 1h — — — approx. 2h USB flash drive∗ (Example: 512 MB) ∗ Please use a USB flash drive without security function. 3 0:00 Remote control / Monitoring function You can remote control the logger from the web browser installed in your PC by connecting the logger with an IP address to the PC through a LAN network. Files stored on the unit (or on the USB flash drive) can be copied to your PC via the web browser as well. Extract data even while logging is in progress USB flash drive LAN cable USB cable Logger display and buttons are completely replicated on the web browser! With the pre-installed FTP server function, data stored on the logger can be transferred to your PC even while logging is in progress. FTP transfer LAN cable Logging in progress Automatic clock-time correction Clock-time of the unit is automatically corrected by the NTP client function. Real-time data gathering in a PC The special software enables real-time data saving in a PC. The logger can be connected to a PC via USB or LAN connection. Captured data can be simultaneously saved on the logger and on a PC, or on the PC only. PC viewer function Special software allows you to display captured data easily in waveform format. Search, printout, and CSV conversion can also be performed. USB cable ∗ Simply start up the software and select a file. For multi-channel measurement and advanced waveform display, we recommend special PC software (Wave Inspire RX). (See p. 8) You can also save and convert logging data directly to Excel format. 4 200-Channel Expandable Temperature Measurement Logger with Internal 4 GB y Flash Memory Internal Large-Capacity 4 GB Flash Memory ZR-RX45 Sampling speed 10 ms 20 ms ∗ Please use a USB flash drive without security function. 1 2 ! Potential recording time (with 20 analog channels) Type of measurement: ∗1 50 ms ∗1 100 ms Temperature ±20 mV to ±50 V Humidity Sensor Humidity (optional ZR-XRH1) Temperature Thermocouples (K, J, E, T, R, S, B, N, W) Thermocouples Resistance thermometer Pulse Logic Resistance thermometer (Pt100, JPt100, Pt1000) Select 4 channels of logic input or 4 channels of pulse input (optional ZR-XRL1) 500 ms 1s 10 s 5 10 20 50 1s 2s 100 200 Voltage ∗ Temperature ∗ Sampling speed for temperature is equivalent to that of voltage, as it is scaled to 0-1 V. approx. approx. approx. approx. 54 days 135 days 270 days 2,701 days ∗1: Number of channels that can be added is limited: at 10 ms, 1 channel; at 50 ms, 5 channels; at 100 ms, 10 channels. ∗2: Please use a USB flash drive without security function. PC compatibility Standard 20CH Max. 200 CH Max. recording time All channels 10 ms isolated USB flash drive USB (High speed) 100BASE-TX 4 GB 5.7 inch internal memory (VGA) 7-hour battery Web server FTP server NTP client 16 bit Easy-tonavigate menus resolution 200 ms 50 ms 100 ms 200 ms 500 ms approx. approx. approx. approx. approx. approx. approx. 29 days 72 days 89 days 101 days 253 days 506 days 5,068 days 1 GB ∗2 approx. approx. approx. USB flash drive 15 days 38 days 47 days Wider range of features ! Potential recording time (with 20 analog channels only) Number of operating channels Internal 4 GB flash memory Multi-function input 10 ms High-Speed Sampling Higher voltage measurement sampling speeds achieved. Data can be captured at intervals as short as 10 ms. The unit features a 4 GB internal flash memory. Long-term data capture is possible without a USB flash drive. With flash memory, data will not be lost even if power is turned off. Of course direct data capture to a USB flash drive is also possible, and data will be stored even if the USB flash drive is replaced while measurement is in progress. Length of data ∗1 capture 10 ms (sampling speed) Voltage Best-In-Class USB flash drive insertion or removal during data gathering (Rpm/Count /Inst.) Easily readable 5.7 inch VGA LCD Secure Ring Memory Capture Comes with bright, easily readable 5.7-inch large-screen color LCD panel with VGA (640 x 480 dot) high resolution. Measured values and waveform can be vividly displayed in addition to set values. This function deletes unneeded past data so that only recent data is saved to the internal memory or USB flash drive at all times. It conveniently allows the data logger to be set up and continually capturing data, and also prevents data capture failure when trouble occurs. (The length of time data is saved can be preset.) Max. 200 Channels, Additional Expandability via PC Connection PC Compatibility Meeting Versatile Requirements Isolated Multi-Function Inputs Each circuit is electrically isolated so that the different channels do not affect each other. Built-in delta-sigma A/D converter boosts anti-noise performance as well. The temperature input supports thermocouples and resistance thermometer. Furthermore, in addition to temperature, an array of measurements including humidity and voltage can be taken at once. It also supports logic or pulse input, input from external triggers, as well as alarm signals output. Versatile PC linkup via LAN, USB, etc. Analog signal input terminal External input terminal Logic alarm cable Logic/ pulse input 3 ways to link to a PC are available through a USB flash drive, a USB connection or a LAN connection. No initial setup is required. Supports all kinds of data applications. Automatic Backup of Captured Data USB memory LAN cable USB cable Alarm output Trigger input GND Temperature Humidity Select either a USB flash drive or FTP server to save captured data. If FTP server is selected, data will automatically be backed up on the server, allowing you to establish an automatic data-gathering system without the need for troublesome programs. Voltage Ethernet Automatic backup Automatic backup ∗ Switches between logic and pulse Full Array of Features Max. in its class Resistance Thermometer Input Expandable up to 200 channels The logger is also compatible with resistance thermometer input, allowing measurement with higher accuracy and greater stability than thermocouples. What’s more, the logger measures up to Pt1000, enabling temperature measurement with precision previously only found in high-cost measurement devices. Each detachable terminal block has a standard 20 channels per unit. Up to 10 units can be connected making it possible to extend up to as much as 200 channels. It can also be used in car data logging where multi-measurements of temperature, voltage, etc. on many channels is needed. Maximum 10 unit connection Base unit cable (Approx. 0.5 m) ∗ Photo shows an Omron platinum temperature resistance thermometer, 52 series. 5 The seismic resistance corresponds to Class 1-A car parts (JIS standards), which means that it can be used stably even when there are vibrations and jolts during data-gathering. MAX 200 CH Remote control / Monitoring function You can remote control the logger from the web browser installed in your PC by connecting the logger with an IP address to the PC through a LAN network. Files stored on the unit (or on the USB flash drive) can be copied to your PC via the web browser as well. Logger display and buttons are completely replicated on the web browser! FTP server USB memory device Automatic clock-time correction CLock-time of the unit is automatically corrected by the NTP client function. Real-time data gathering in a PC The special software enables real-time data saving in a PC. The logger can be connected to a PC via USB or LAN connection. Captured data can be simultaneously saved on the logger and on a PC, or on the PC only. PC viewer function Special software allows you to display captured data easily in waveform format. Search, printout, and CSV conversion can also be performed. USB cable ∗ Simply start up the software and select a file. For multi-channel measurement and advanced waveform display, we recommend special PC software (Wave Inspire RX). (See p. 8) You can also save and convert logging data directly to Excel format. 6 200-Channel Expandable Temperature Measurement Logger with Internal 2 GB y Flash Memory Internal Large-Capacity 4 GB Flash Memory ZR-RX45 Sampling speed 10 ms 20 ms ∗ Please use a USB flash drive without security function. 1 2 ! Potential recording time (with 20 analog channels) Type of measurement: ∗1 50 ms ∗1 100 ms Temperature ±20 mV to ±50 V Humidity Sensor Humidity (optional ZR-XRH1) Temperature Thermocouples (K, J, E, T, R, S, B, N, W) Thermocouples Resistance thermometer Pulse Logic Resistance thermometer (Pt100, JPt100, Pt1000) Select 4 channels of logic input or 4 channels of pulse input (optional ZR-XRL1) 500 ms 1s 10 s 5 10 20 50 1s 2s 100 200 Voltage ∗ Temperature ∗ Sampling speed for temperature is equivalent to that of voltage, as it is scaled to 0-1 V. approx. approx. approx. approx. 54 days 135 days 270 days 2,701 days ∗1: Number of channels that can be added is limited: at 10 ms, 1 channel; at 50 ms, 5 channels; at 100 ms, 10 channels. ∗2: Please use a USB flash drive without security function. PC compatibility Standard 20CH Max. 200 CH Max. recording time All channels 10 ms isolated USB flash drive USB (High speed) 100BASE-TX 4 GB 5.7 inch internal memory (VGA) 7-hour battery Web server FTP server NTP client 16 bit Easy-tonavigate menus resolution 200 ms 50 ms 100 ms 200 ms 500 ms approx. approx. approx. approx. approx. approx. approx. 29 days 72 days 89 days 101 days 253 days 506 days 5,068 days 1 GB ∗2 approx. approx. approx. USB flash drive 15 days 38 days 47 days Wider range of features ! Potential recording time (with 20 analog channels only) Number of operating channels Internal 4 GB flash memory Multi-function input 10 ms High-Speed Sampling Higher voltage measurement sampling speeds achieved. Data can be captured at intervals as short as 10 ms. The unit features a 4 GB internal flash memory. Long-term data capture is possible without a USB flash drive. With flash memory, data will not be lost even if power is turned off. Of course direct data capture to a USB flash drive is also possible, and data will be stored even if the USB flash drive is replaced while measurement is in progress. Length of data ∗1 capture 10 ms (sampling speed) Voltage Best-In-Class USB flash drive insertion or removal during data gathering (Rpm/Count /Inst.) Easily readable 5.7 inch VGA LCD Secure Ring Memory Capture Comes with bright, easily readable 5.7-inch large-screen color LCD panel with VGA (640 x 480 dot) high resolution. Measured values and waveform can be vividly displayed in addition to set values. This function deletes unneeded past data so that only recent data is saved to the internal memory or USB flash drive at all times. It conveniently allows the data logger to be set up and continually capturing data, and also prevents data capture failure when trouble occurs. (The length of time data is saved can be preset.) Max. 200 Channels, Additional Expandability via PC Connection PC Compatibility Meeting Versatile Requirements Isolated Multi-Function Inputs Each circuit is electrically isolated so that the different channels do not affect each other. Built-in delta-sigma A/D converter boosts anti-noise performance as well. The temperature input supports thermocouples and resistance thermometer. Furthermore, in addition to temperature, an array of measurements including humidity and voltage can be taken at once. It also supports logic or pulse input, input from external triggers, as well as alarm signals output. Versatile PC linkup via LAN, USB, etc. Analog signal input terminal External input terminal Logic alarm cable Logic/ pulse input 3 ways to link to a PC are available through a USB flash drive, a USB connection or a LAN connection. No initial setup is required. Supports all kinds of data applications. Automatic Backup of Captured Data USB memory LAN cable USB cable Alarm output Trigger input GND Temperature Humidity Select either a USB flash drive or FTP server to save captured data. If FTP server is selected, data will automatically be backed up on the server, allowing you to establish an automatic data-gathering system without the need for troublesome programs. Voltage Ethernet Automatic backup Automatic backup ∗ Switches between logic and pulse Full Array of Features Max. in its class Resistance Thermometer Input Expandable up to 200 channels The logger is also compatible with resistance thermometer input, allowing measurement with higher accuracy and greater stability than thermocouples. What’s more, the logger measures up to Pt1000, enabling temperature measurement with precision previously only found in high-cost measurement devices. Each detachable terminal block has a standard 20 channels per unit. Up to 10 units can be connected making it possible to extend up to as much as 200 channels. It can also be used in car data logging where multi-measurements of temperature, voltage, etc. on many channels is needed. Maximum 10 unit connection Base unit cable (Approx. 0.5 m) ∗ Photo shows an Omron platinum temperature resistance thermometer, 52 series. 5 The seismic resistance corresponds to Class 1-A car parts (JIS standards), which means that it can be used stably even when there are vibrations and jolts during data-gathering. MAX 200 CH Remote control / Monitoring function You can remote control the logger from the web browser installed in your PC by connecting the logger with an IP address to the PC through a LAN network. Files stored on the unit (or on the USB flash drive) can be copied to your PC via the web browser as well. Logger display and buttons are completely replicated on the web browser! FTP server USB memory device Automatic clock-time correction CLock-time of the unit is automatically corrected by the NTP client function. Real-time data gathering in a PC The special software enables real-time data saving in a PC. The logger can be connected to a PC via USB or LAN connection. Captured data can be simultaneously saved on the logger and on a PC, or on the PC only. PC viewer function Special software allows you to display captured data easily in waveform format. Search, printout, and CSV conversion can also be performed. USB cable ∗ Simply start up the software and select a file. For multi-channel measurement and advanced waveform display, we recommend special PC software (Wave Inspire RX). (See p. 8) You can also save and convert logging data directly to Excel format. 6 Easy-to-use and Compact 10-Channel Logger with Internal 4 GB Flash Memory ZR-RX25 Multi-function input Voltage ±20 mV to ±50 V Wider range of features Thermocouples Pulse Logic All channels 10 ms isolated 4 GB 4.3 inch internal memory (WQVGA) 6-hour battery B, N, W) Humidity Humidity Sensor (optional ZR-XRH1 required) Select 4 channels of logic input or 4 channels of pulse input (optional ZR-XRL1) USB flash drive Max. recording time 10 CH Temperature (K, J, E, T, R, S, PC compatibility USB (Full speed) USB flash drive insertion or removal during data gathering 16 bit resolution (Rpm/Count /Inst.) Easy-to-use and Affordable, Yet Capable of 10 ms Sampling Speeds! Meeting Versatile Requirements First in its class 10 Isolated Channels + Multi-Input Though the unit is light and compact, each channel is supplied with its own isolated circuit giving zero inter-channel noise interference. A delta-sigma A/D converter boosts anti-noise performance as well. With inputs not only for temperature but also voltage, humidity, pulse, and logic, this model is suitable for any field. External input terminal Logic alarm cable Logic/ pulse input Analog signal input terminal Alarm output Trigger input GND Temperature Humidity Voltage ∗ Switches between logic and pulse Full Array of Features Fastest in its class 10 ms High-Speed Sampling Internal Large-Capacity 4 GB Flash Memory Higher voltage measurement sampling speeds achieved. Data can be captured at intervals as short as 10 ms. Sampling speed 10 ms 20 ms 50 ms 100 ms 1s Number of operating channels 1 2 5 10 10 Type of measurement: Voltage ∗ Temperature ∗ Sampling speed for temperature is equivalent to that of voltage, as it is scaled to 0-1 V. The unit features a 4 GB internal flash memory. Long-term data capture is possible without a USB flash drive. With flash memory, data will not be lost even if power is turned off. Of course, direct data capture to a USB flash drive is also possible, and data will be stored even if the USB flash drive is replaced while measurement is in progress. ∗ Please use a USB flash drive without security function ! Potential recording time (with 10 analog channels) ∗1 Secure Ring Memory Capture This function overwrites unneeded past data so that only recent data is saved to the internal memory or USB flash drive device at all times. It conveniently allows the data logger to be set up and continually capturing data, and also prevents data capture failure when trouble occurs. Max. in its class 10 ms Internal 4 GB flash memory ∗1 50 ms 100 ms 200 ms 500 ms 10 s 1 GB approx. approx. approx. ∗2 approx. approx. approx. approx. USB flash drive 20 days 44 days 51 days 103 days 258 days 517 days 5,178 days ∗1: Number of channels that can be added is limited: at 10 ms, 1 channel; at 50 ms, 5 channels. ∗2: Please use a USB flash drive without security function. PC Compatibility Handy PC linkup via USB connection 7 1s approx. approx. approx. approx. approx. approx. approx. 38 days 83 days 97 days 194 days 485 days 971 days 9,714 days The logger is equipped with a USB flash drive for direct data capture. With PC connection, data in the USB flash drive can be displayed in Excel format. Connection to a PC is easy with a USB cable, and logger settings can be determined and data transferred in real time using special PC software. PC connection also allows the logger to be used as a USB flash drive. USB connection Easy-to-use and Compact 10-Channel Logger with Internal 2 GB Flash Memory NEW Option p ZR-RX25 Special PC software ZR-SX10 ZR SX 0 Quick call-up of the cursor Special search function Screen-save function / CSV-save function Report-printing function Major functions Easy-to-use operation plus processing capabilities beyond previous logger software! Multi-function input Voltage ±20 mV to ±50 V Wider range of features Thermocouples Pulse Logic Select 4 channels of logic input or 4 channels of pulse input (optional ZR-XRL1) USB flash drive All channels 10 ms isolated 2 GB 4.3 inch internal memory (WQVGA) 6-hour battery B, N, W) Humidity Humidity Sensor (optional ZR-XRH1 required) PC compatibility Max. recording time 10 CH Temperature (K, J, E, T, R, S, Wave Inspire RX, a special PC software program, offers intuitive operability and data processing capabilities beyond all previous logger software. Featuring a number of functions not available in standard logging software programs, it allows you to directly grab and drag waveforms and scales with the mouse cursor, as well as to group channels freely and operate multiple windows. Different categories of data can be compared, and the waveform of each input signal can be observed with ease, making it particularly useful when handling a large number of multi-channel measurements. USB (Full speed) USB flash drive insertion or removal during data gathering 16 bit resolution Free Adjustment Function (Rpm/Count /Inst.) Intuitive Control Free adjustment function Meeting Versatile Requirements Insert comment at an arbitrary position on the waveform First in its class Move scale left or right 10 Isolated Channels + Multi-Input Though the unit is light and compact, each channel is supplied with its own isolated circuit giving zero inter-channel noise interference. A delta-sigma A/D converter boosts anti-noise performance as well. With inputs not only for temperature but also voltage, humidity, pulse, and logic, this model is suitable for any field. Move waveform up or down External input terminal Logic alarm cable Logic/ pulse input Analog signal input terminal Click on waveform, scale, or cursor, and move Change the position of the waveform with a single click of an icon Alarm output Trigger input GND Temperature Humidity Voltage ∗ Switches between logic and pulse Fastest in its class Internal Large-Capacity 2 GB Flash Memory Higher voltage measurement sampling speeds achieved. Data can be captured at intervals as short as 10 ms. Sampling speed 10 ms 20 ms 50 ms 100 ms 1s Number of operating channels 1 2 5 10 10 Type of measurement: Voltage ∗ Temperature ∗ Sampling speed for temperature is equivalent to that of voltage, as it is scaled to 0-1 V. Secure Ring Memory Capture This function overwrites unneeded past data so that only recent data is saved to the internal memory or USB flash drive device at all times. It conveniently allows the data logger to be set up and continually capturing data, and also prevents data capture failure when trouble occurs. Max. in its class ∗ Please use a USB flash drive without security function 왎 Potential recording time (with 10 analog channels) 10 ms Internal 2 GB flash memory ∗1 50 ms 100 ms 200 ms 500 ms Smart search Multiple display Grouping Temperature The unit features a 2 GB internal flash memory. Long-term data capture is possible without a USB flash drive. With flash memory, data will not be lost even if power is turned off. Of course, direct data capture to a USB flash drive is also possible, and data will be stored even if the USB flash drive is replaced while measurement is in progress. ∗1 1s Display for each input signal Search all the Voltage channels Voltage Search selected channels in one operation! After the search the channels have selected status. Drag and drop into the “IC Chip Voltage” group Grouping is simple by dragging and dropping into the created groups. Compare multiple boards (target) For each group a waveform screen can be displayed, so observation of comparisons between groups is possible. 10 s approx. approx. approx. approx. approx. approx. approx. 38 days 83 days 97 days 194 days 485 days 971 days 9,714 days 1 GB approx. approx. approx. ∗2 approx. approx. approx. approx. USB flash drive 20 days 44 days 51 days 103 days 258 days 517 days 5,178 days ∗1: Number of channels that can be added is limited: at 10 ms, 1 channel; at 50 ms, 5 channels. ∗2: Please use a USB flash drive without security function. Multi-Connection of Different Types of Loggers ∗ When sampling speed is 1 ms or faster. Handy PC linkup via USB connection The logger is equipped with a USB flash drive for direct data capture. With PC connection, data in the USB flash drive can be displayed in Excel format. Connection to a PC is easy with a USB cable, and logger settings can be determined and data transferred in real time using special PC software. PC connection also allows the logger to be used as a USB flash drive. Viewing Data from Two Data Loggers Simultaneously If you connect ZR-RX70 and ZR-RX45 via LAN connection, you can view temperature data measured by ZR-RX45 and voltage data measured by ZR-RX70 simultaneously, and save the data from the different loggers as one file. You can handle data from the two loggers without any data-combining processes. PC Compatibility 7 Sophisticated Data Processing Easy Comparison and Quick Decision Full Array of Features 10 ms High-Speed Sampling Display superimposed Display side by side Easy-to-use and Affordable, Yet Capable of 10 ms Sampling Speeds! USB connection 8 ■ Standard Specifications Main Unit ZR-RX45AZR-RX25AZR-RX70AAll channels isolated input ∗1 All channels isolated input All channels isolated input, Simultaneous sampling of all channels BNC terminal: For voltage measurement M3 screw type terminal M3 screw type terminal: For voltage/temperature measurement ∗2 8 ch 10 ch Number of analog input channels Standard: 20 ch Max.: 200 ch (When the terminal unit is connected) 10 µs to 1 min Sampling speeds 10 ms (when 1 ch is used) to 1 h Item Input method Input terminal shape A/D resolution A/D conversion system 16 bit Sequential comparison 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100, 200, 500 V, 1-5 V F.S. Voltage Delta-sigma 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, 1-5 V F.S. K, J, E, T, R, S, B, N, W (WRe5-26) Thermocouple MeasureTemper- Resistance ment ranges ature temperature — — Pt100, JPt100, Pt1000 (IEC751) detector Humidity External Digital input input/output Alarm output sections Functions 0% to 100% (Voltage 0 to 1 V scaling conversion) Logic input (4 ch) or Pulse input (4 ch) ∗4 ∗5 4 ch (Open collector output) External trigger input (1 ch), input signal level, time In combination with timer mode, date and time can be set, and a wide variety of trigger settings such as “Every Day Cycle” and “Every Hour Cycle” can be made Trigger functions External trigger input (1 ch), Input signal level, time, duration, alarm External trigger input (1 ch), Input signal level, time, duration Off, Line, 5 Hz, 50 Hz, 500 Hz Off, 2, 5, 10, 20, 40 (moving average) Statistical calculation ∗6: Average, peak, maximum, minimum, RMS (maximum of 2 can be set simultaneously) Filter functions Calculation function Type PCI/F ∗3 USB1.1 (FULL SPEED) LAN (100BASE-TX), USB2.0 (HIGH SPEED) Ethernet Web server function, FTP server function, NTP client function Web server function, FTP server function, FTP client function, NTP client Realtime data transfer to the PC, Unit control from a PC function, Realtime data transfer to the PC, Unit control from a PC Function functions Memory Internal devices External RAM: approx. 64 MB Flash memory: approx. 256 MB Display Operating environment Vibration resistance Power supply Power consumption Weight External dimensions Accessories USB memory ∗7 5.7-inch color LCD (VGA: 640 × 480 dots) 4.3-inch color LCD (WQVGA: 480 × 272 dots) 0 to 45°C, 5% to 85% (0 to 40°C when operated on batteries, 15 to 35 °C when charging batteries) 5.7-inch color LCD (QVGA: 320 × 240 dots) 0 to 40°C, 5% to 85% (15 to 35°C when operated on batteries) Equivalent to automobile parts Type 1 Category A classification AC adaptor; AC100 to 240 V/50 to 60 Hz ∗8, DC drive: 8.5 V to 24 V, Battery: DC7.4 V (2 packs) AC adaptor: AC100 to 240 V/50 to 60 Hz ∗8, DC drive: 8.5 V to 24 V, Battery: DC7.4 V 42 VA (When the AC adaptor is used) 32 VA (When the AC adaptor is used) 29 VA (When the AC adaptor is used) approx. 1.1 kg (Excluding batteries and AC adaptor) approx. 900 g (Including one terminal unit, excluding batteries and AC adaptor) 232 × 150 × 80 mm 232 × 152 × 50 mm User's Manual, Utility disk (CD-ROM), AC Adaptor/AC cable ∗1: Resistance temperature detector is non-isolated. ∗2: BNC terminal and M3 screw type terminal of the same channel cannnot be used simultaneously. ∗3: A humidity sensor ZR-XRH1 is necessary. ∗4: A logic alarm cable ZR-XRL1 is necessary. ∗5: Pulse input: Revolutions mode/Counts mode/ Inst. mode switch method Measurement Accuracy Item Voltage Temperature ∗1 ±0.25% of F.S. Measurement Thermocouple temperature range (°C) ZR-RX45A- /ZR-RX25A±0.1% of F.S. Measurement Measurement temperature range (°C) accuracy Measurement accuracy 0 ≤ TS ≤ 100 100 < TS ≤ 300 ±7.0°C ±5.0°C R : 300 < TS ≤ 1600 S : 300 < TS ≤ 1760 ±(0.05% of rdg + 3.0°C) R: 300 < TS ≤ 1600 ±(0.05% of rdg + 3.0°C) S: 300 < TS ≤ 1760 ±(0.05% of rdg + 2.0°C) ±(0.05% of rdg + 2.0°C) B 400 ≤ TS ≤ 600 600 < TS ≤ 1820 ±5.5°C 400 ≤ TS ≤ 600 ±(0.05% of rdg + 3.0°C) 600 < TS ≤ 1820 ±3.5°C ±(0.05% of rdg + 2.0°C) K –200 ≤ TS ≤ –100 –100 < TS ≤ 1370 –200 ≤ TS ≤ –100 –100 < TS ≤ 800 –200 ≤ TS ≤ –100 –100 < TS ≤ 400 –200 ≤ TS ≤ –100 –100 < TS ≤ 100 100 < TS ≤ 1100 0 ≤ TS ≤ 1300 0 ≤ TS ≤ 2000 ±(0.05% of rdg + 3.0°C) ±(0.05% of rdg + 2.0°C) ±(0.05% of rdg + 3.0°C) ±(0.05% of rdg + 2.0°C) ±(0.1% of rdg + 2.5°C) ±(0.1% of rdg + 1.5°C) ±3.7°C ±2.7°C ±(0.05% of rdg + 2.0°C) ±(0.1% of rdg + 2.0°C) ±(0.1% of rdg + 2.5°C) ±(0.05% of rdg + 2.0°C) ±(0.05% of rdg + 1.0°C) ±(0.05% of rdg + 2.0°C) ±(0.05% of rdg + 1.0°C) ±(0.1% of rdg + 1.5°C) ±(0.1% of rdg + 0.5°C) ±2.7°C ±1.7°C ±(0.05% of rdg + 1.0°C) ±(0.1% of rdg + 1.0°C) ±(0.1% of rdg + 1.5°C) E T J N W 0 ≤ TS ≤ 100 100 < TS ≤ 300 −200 ≤ TS ≤ −100 −100 < TS ≤ 1370 −200 ≤ TS ≤ −100 −100 < TS ≤ 800 −200 ≤ TS ≤ −100 −100 < TS ≤ 400 −200 ≤ TS ≤ −100 −100 < TS ≤ 100 100 < TS ≤ 1100 0 ≤ TS ≤ 1300 0 ≤ TS ≤ 2000 Compatible logger Compatible operating system ∗6: Designate real-time or between-cursors mode (during playback) ∗7: 1 file max. 2GB (The capacity will vary depending on the external memory used.) ∗8: Be sure to use only the AC cable and AC adaptor provided as accessories. ±5.2°C ±3.0°C Resistance temperature detector Pt100 JPt100 Measurement temperature range (°C) Applied current Measurement accuracy –200 to 850°C (FS = 1050°C) –200 to 500°C (FS = 700°C) –200 to 500°C (FS = 700°C) 1 mA 1 mA 0.2 mA ±1.0°C ±0.8°C ±0.8°C Pt1000 ∗1 ● ZR-RX70 Operating environment 23°C±5°C When 30 minutes or more have elapsed after power was switched on Filter Line/GND connected; Thermocouple used is T: 0.32 dia., others: 0.65 dia. Special PC software ZR-SX10 Wave Inspire RX (Since Ver.2.4) (Option Specifications) ZR-RX25/RX45/RX70/RX20/RX40 ● ZR-RX25/RX45 Operating environment 23°C±5°C; When 30 minutes or more have elapsed after power was switched on Sampling 1 s/Filter ON (10 times) GND connected Thermocouple used is T: 0.32 dia., others: 0.65 dia. Resistance temperature detector is available only for ZR-RX45. Humidity Sensor ZR-XRH1 (Option) Item Allowable temperature range Description –25 to 80°C Allowable humidity range 0% to 100% Relative humidity measurement accuracy ±3% (5% to 98% at 25°C) 15 sec (90% response when membrane filter installed) Response time Sensor output External dimensions Cable length PC Software Item approx. 520 g (Excluding battery and AC adaptor) 194 × 117 × 42 mm Measurement Accuracy (ZR-RX45 only) ZR-RX70A- R/S — Realtime data transfer to the PC Flash memory: approx. 4 GB ∗7 USB 0 to 1 VDC dia. 14 mm × 80 mm (excluding cable) 3m Standard PC software Smart Viewer RXW (Since Ver.2.0) (Standard accessories) Smart Viewer RX70 (Since Ver.2.0) (Standard accessories) ZR-RX70 ZR-RX25/RX45/RX20/RX40 Windows XP / Windows Vista / Windows 7 Windows 2000 / Windows XP / Windows Vista Intel-compatible, 1 GHz or faster processor recommended, Intel Atom CPU not supported Pentium 4: 2.0 GHz or faster processor recommended, Intel Atom CPU not supported CPU Memory Display Compatible interface Standard functions 1024 × 768 or higher, screen resolution, 65,535 color (16-bit color) or higher screen display Waveform operation Direct operation of waveform by mouse or icons, Batch processing of selected waveform Change CH scales individually by icons Display graphs in multi-window, X-Y View, FFT View, Handy function of switching waveform, Display function of grouping channel, Scrolling for all directions (up, down, right, left) Display in single window, X-Y View between Cursors (only during replay), Display function of grouping channel Waveform display Windows XP: 512 MB or more Windows Vista / Windows 7:1GB or more 1024 × 768 or higher screen resolution USB, LAN Review saved data, real-time capture of PC data, main unit setup, CSV file conversion Configuration function Advanced channel grouping function, Advanced Listview setup function, Main unit setup External control of sampling — Captured data Others 512 MB or more (recommended: 1 GB or more) Channel grouping fuction, Main unit setup Available (can set and display) Binary file (original format): Captured data and the information of graph window are saved. CSV file: Captured data is saved in comma-separated value format: Binary files can be converted to CSV files all at once Cursor function, Comment Input function, Excel transfer function *1: Even when using a PC with adequate specifications, capture errors occur at times because the PC is in bad condition. (For example, when other applications are open, or recording medium has no free area.) When you capture data using this software, please close all the other applications and save captured data to the hard disk. *2: Don’t start up other applications while this software is operating, and don’t perform multiple operations. (For example, screen saver, virus scan program, copying and moving files, searching files, etc.) 9 ■ System Configuration Standard set ZR-RX70A-: ZR-RX45A-: ● ∗ Content of utility disk Main unit –Standard PC software: AC adaptor/AC cable Smart Viewer RX70 ● User’s manual –Special PC software: ● Utility disk ∗ Wave Inspire RX ● ● ● Main unit AC adaptor/AC cable ● User’s manual ● Utility disk ∗ (Trial version) –Manual PDF file ZR-RX25A-: ∗ Content of utility disk –Standard PC software: Smart Viewer RXW –Special PC software: Wave Inspire RX (Trial version) –Manual PDF file ∗ Content of utility disk Main unit –Standard PC software: AC adaptor/AC cable Smart Viewer RXW ● User’s manual –Special PC software: ● Utility disk ∗ Wave Inspire RX ● ● (Trial version) –Manual PDF file [ZR-RX common] Special PC Software ZR-SX10 DC Cable (2 m) ZR-XRD1 Battery Pack ZR-XRB1 Humidity Sensor (3 m) ZR-XRH1 Logic Alarm Cable (2 m) ZR-XRL1 [ZR-RX45 common] Base Set ZR-XRE1 Extension Terminal Set ZR-XRT1 Cable (Accessory, 0.5 m) [For ZR-RX70] ZR-RX45 Necessary option when channel is enhanced BNC-Crocodile Cable (2 m) ZR-XRC1 Item ZR-RX45 Main unit Base Set (ZR-XRE1) Extension Terminal Set (ZR-XRT1) 20 CH 1 0 0 40 CH 1 1 1 100 CH 1 1 4 200 CH 1 1 9 ■ Model Option Standard set Item Data Logger Model ZR-RX70A-: ZR-RX45A-: ZR-RX25A-: Models compatible with power supply and voltage specifications for each country, as well as conforming to Chinese RoHS are also available. For details, please consult your dealer. Item Battery Pack Humidity Sensor (3 m) DC Cable (2 m) Logic Alarm Cable (2 m) Base Set (For ZR-RX45) Extension Terminal Set (For ZR-RX45) BNC-Crocodile Cable (2 m) (For ZR-RX70) Special PC Software Wave Inspire RX Model ZR-XRB1 ZR-XRH1 ZR-XRD1 ZR-XRL1 ZR-XRE1 ZR-XRT1 ZR-XRC1 ZR-SX10 Please visit the Omron web site for details on calibration service formats and prices. http://www.fa.omron.co.jp/ Extensive lineup of temperature sensors also available. For details, please visit the Omron web site. 10 ■ External Dimensions (Unit: mm) Tolerance class IT16 applies to the dimensions unless otherwise specified. ZR-RX70 ZR-RX45 232 2 32 48 120 24.6 122 3.5 232 75 5 ZR-RX70 Mounting Screw Holes 2-M4 Depth 6 ZR-RX45 Mounting Screw Holes 2-M4 Depth 6 69 185 23.5 ZR-RX25 91.6 162 16.1 67 102 15 16.5 2-M4 L5 Insert Screw 2 40 194 Stability for Use Omron Companies shall not be responsible for conformity with any standards, codes or| regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit OMRON ELECTRONICS LLC Carl-Benz-Str. 4, D-71154 Nufringen, Germany IL 60173-5302 U.S.A. Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, Alexandra Technopark, 200 Yin Cheng Zhong Road, Singapore 119967 PuDong New Area, Shanghai, 200120, China Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 One Commerce Drive Schaumburg, © OMRON Corporation 2010-2013 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_6_1_0814 Cat. No. E410-E1-03 Printed in Japan 0413 (0311) (TA)