MEMORY HiCORDER 8835-01 Recorders High-visibility display, Compact body, Multi-channeled inputs Field Measurement has never been easier The MEMORY HiCORDER 8835-01 is a high-speed waveform recorder with the special features of advanced performance of the basic “wave recording” function for easy field measurement, easy-to-see color display, compact dimensions of an A4-sized paper, and 4/8* channels for measurement. The MEMORY HiCORDER 8835 -01 inherits all the functions of the MEMORY HiCORDER 8835 and accommodates a total of 8* channels when used with the input unit group to support a wide range of signals. The 8835-01 also comes standardly equipped with 8x the memory of the previous unit, making long-term recording possible. * When using the 4ch ANALOG UNIT 8946, maximum input is 30V rms or 60V DC. 2 Compact 4ch/8ch* recorder saves space with slim profile 1 *1 When using the 4ch ANALOG UNIT 8946, maximum input is 30V rms or 60V DC - Features ● Conversion According to the Measurement, Plug-in Input Function for a Maximum of 8 Channels*1 The 8835 -01 employs a plug-in unit system that can change the measurement channels according to the measurement use. Directly inputting physical signals through inserted conversion amplifiers is also possible. A maximum of 8 channels*1 can be used for measurement by mounting a 4-channel analog unit on the recorder. ● High-visibility waveforms displayed on a 6.4-inch color TFT liquid crystal display The color display makes it easier to identify waveforms and install the device. It enhances visibility and facilitates operations. ● Compact and thin, occupying a space equivalent to 60% of an A4-size sheet of paper Occupying desktop space equivalent to 60% of an A4-size sheet of paper, the MEMORY HiCORDER 8835-01 is functionally designed so as to permit operation on a flat bed. ● Highly Improved Basic Performance with 1MS/s, 12bit-A/D, 4MW T he 8 8 3 5 - 0 1 employs a sa mpl i ng r at e of 1MS /s (1μs cycle) a nd 12 -bit volt age -a x is r esolut ion for t he A / D conver ter un it, wh ich digitizes measurement signa ls, enabling accurate detection of signal waveforms. With the 8835 -01, the standard memory capacity is 4MW. ● Converts to text file used with a Wave viewer (supplied accessories, PC application software) To open measurement data in PC applications such as Excel, the data must be converted to text data in the CSV format. The PC application software which comes standard in the package enables easy operation. ● Connects to PCs and printers on a LAN network Its use with PCs can be selected according to the usage. It allows remote operation and data transfer via LA N connection, GP-IB connection, or RS-232C connection. ● Function upgrade system to meet varied needs The basic model provides several standard functions for users who donʼt require functional complexity. Users requiring a wider range of measurement functions can add functions through the use of a function upgrade disk. ● On-screen help To help the user get started or clarify operating steps, the 8835 -01 can display tips on-screen for many basic operations, including key-button operations. ● CE Mark compliant Complies with the EC directive determining safety standards in Europe (within the EU). A LAN-Connectable Recorder! Digitally Process Test Data With a conventional pen recorder, even if all test data is written on the paper, usually only a small portion of the data is needed. However, to look for just a small important part requires very extensive search of the recording paper. The MEMORY HiCORDER 8835 -01 stores and manages all waveform measurement data electronically. Furthermore, use of a LAN card and the LAN COMMUNICATOR 9333 enables high-speed data file transfer to PCs on a network. Example of using measurement data in Excel 3 High-Speed Response for Capturing Transient Events - Function Details - Large memory capacity allows long-term recording of high- speed data A/D conversion Insulation Function outline of memory recorder Input voltage The 8835 -01 can store a total of 4 mega-words, using internal solid-state memory. This provides ample capacity to store data for all 8 channels. The table at right shows possible recording times, according to the time axis setting and the number of channels in use. A reduction in the number of channels prolongs the recording time. Write on memory A/D conversion Insulation Input voltage Input voltage Input waveform Sampling period Time Time axis 100μs/DIV 200μs/DIV 500μs/DIV 1ms/DIV 2ms/DIV 5ms/DIV 10ms/DIV 20ms/DIV 50ms/DIV 100ms/DIV 200ms/DIV 500ms/DIV 1s/DIV 2s/DIV 5s/DIV 10s/DIV 30s/DIV 1min/DIV 2min/DIV 5min/DIV ■ Memory segmentation function (an optional FUNCTION UP DISK 9540-01 is needed) When using the memory recorder function, the data memory can be divided into a maximum of 255 blocks. Data can be written sequentially to the memory blocks, and the waveform in a reference block and any other block can be superimposed and compared. Recording length using 8 channels Segmentation Segmentation into 3 blocks Segmentation into 127 blocks ■ Zoom function *In memory recorder function To make the most of the large-capacity memory, it is possible to display a compressed waveform simultaneously with a magnified waveform. Since the 8835 -01 is capable of storing a large amount of data, high-speed sampling is also possible for waveforms with a long duration. Accordingly, while observing the compressed image of the entire waveform, it is also possible to observe the magnified details of desired parts. Compressed display of a part of the entire waveform is also possible. ■ Clock input for external sampling *In memory recorder function The sampling rate for the memory recorder can be controlled by the timing of an external clock signal. This is useful for example to collect data synchronized to the running cycle of an engine. Maximum frequency 500kHz Input voltage Input waveform Sampling controlled by external clock signal Thermal printer Sampling period Time Output waveform Sampling period 1-channel setting 4 MW/channel, 40000 DIV 8-channel setting 500 kW/channel, 5000 DIV 1μs 2μs 5μs 10μs 20μs 50μs 100μs 200μs 500μs 1ms 2ms 5ms 10ms 20ms 50ms 100ms 300ms 0.6s 1.2s 3.0s 4s 8s 20 s 40 s 1 m 20 s 3 m 20 s 6 m 40 s 13 m 20 s 33 m 20 s 1 h 6 m 40 s 2 h 13 m 20 s 5 h 33 m 20 s 11 h 6 m 40 s 22 h 13 m 20 s 2 days 7 h 33 m 20 s 4 days 15 h 6 m 40 s 13 days 21 h 20 m 27 days 18 h 40 m 55 days 13 h 20 m 138 days 21 h 20 m 0.5 s 1s 2.5 s 5s 10 s 25 s 50 s 1 m 40 s 4 m 10 s 8 m 20 s 16 m 40 s 41 m 40 s 1 h 23 m 20 s 2 h 46 m 40 s 6 h 56 m 40 s 13 h 53 m 20 s 1 day 17 h 40 m 3 days 11 h 20 m 6 days 22 h 40 m 17 days 8 h 40 m 4 High-speed response and Effective value recorder functions are useful in following signal variations - Function Details - Outline of recorder function The input signal is converted to digital form and displayed and printed in real time. The chart speed is a maximum of 20mm/s (in the 500ms/division range). Even with real-time recording, the last 2000 divisions of the waveform can be observed (by scrolling both horizontally and vertically) and reprinted following measurement. Recording Time of the Recorder Virtual recording The 8835 -01 supports a high-speed recording function in the memory with no need for recording paper. Although realtime recording on the recording paper is not possible in the high-speed range of the recorder function (10ms to 200ms/ division), the waveforms are stored in the memory and can therefore be monitored on the screen. The last 2000 divisions of the waveform are retained in the memory before the measurement is completed. If the recording length is not set to “continuous”, the printer can also be operated, allowing waveforms to be printed out later. Time axis 10ms*2/DIV 20ms*2/DIV 50ms*2/DIV 100ms*2/DIV 200ms*2/DIV 500ms/DIV 1 s/DIV 2 s/DIV 5 s/DIV 10 s/DIV 30 s/DIV 1 min/DIV 2 min/DIV 5 min/DIV 10 min/DIV 30 min/DIV 1 hr/DIV Chart speed Sampling period 20mm/s 1μs 10μs 100μs 20mm/s 1μs, 10μs 100μs, 1ms 10mm/s 5mm/s 2mm/s 1mm/s 20mm/min 10mm/min 5mm/min 2mm/min 1mm/min 20mm/hr 10mm/hr 1μ, 10μ, 100μs 1ms, 10ms 1μs 10μs 100μs 1ms 10ms 100ms Recording time for approx. 1 roll of recording paper (30m)*1 20 s 40 s 1 m 40 s 3 m 20 s 6 m 40 s 24 m 45 s 49 m 30 s 1 h 39 m 00 s 4 h 7 m 30 s 8 h 15 m 24 h 45 m 2 days 1 h 30 m 4 days 3 h 00 m 10 days 7 h 30 m 20 days 15 h 61 days 21 h 123 days 18 h *1 Based on 2970 divisions, assuming that about 30 cm of the paper length will not be used. *2 Real-time recording on the recording paper is not possible. Continuous X-Y recorder function This function allows two signals converted to digital form to be combined in an x-y plot and stored in memory. Any of the four analog channels can be used for an x-y plot, and up to three x-y plots can be combined. The x-y plot can be viewed on the screen in real time, and the recording time is unlimited. The x-y plot can also be reprinted. Effective value (RMS-value) recorder function This function is designed exclusively for use on 50/60Hz power supply lines and DC. High-speed sampling is applied to calculate the rms value from the waveform data, and the result is recorded as a graph. Note: Using fixed 200μs sampling, data for two waveforms are captured for calculating the rms value. This process is repeated 20 times per second, resulting in high-speed response that is 10 times faster than that of a digital tester or similar (using a 2-second update rate). 5 Easily interfaced with a PC or a waveform comparator Support for connection to PCs via Ethernet ■ Connect HiCORDER to departmental LAN (using TCP/IP communication protocol) 8835 -01 can be connected to Ethernet, a standard network protocol in the Internet age (using the optional LAN CARD and LAN COMMUNICATOR 9333) . For those who frequently analyse measurement data on PCs, this function offers a good match. Also, connection to PCs using RS-232C connection or GP-IB connection is possible (using the optional RS-232C CARD 9557 and GP-IB CARD 9558). 8835 -01 data can be sent to PCs or be remotely controlled from PCs. Ethernet * Because LAN card, GP-IB card, and RS-232C card all use the same PC card slot of 8835 -01, when one of them is inserted into the PC card slot, then any memory card cannot be used at the same time. Copy or remote operations of HiCORDER data files from client PCs running 9333 (software) ■ Save data to network server Color image output to the network printer (using TCP/IP communication protocol) Offline data exchange with PCs The supplied waveform viewer (PC application) can convert saved waveform data to text files (CSV format). For data storage, FD/PC card (supplied as standard) can be used. This allows easy offline data exchange with PCs. Ethernet PC running 9333 (software) Copy measurement data files obtained from HiCORDER to PC on network Memory / main unit * In addition to HiCORDER's read/write native file (binary format), data can also be saved to text files (CSV format) which can be opened by PC spreadsheet applications, or waveform bitmap files (BMP format). However, because data saved in text files cannot be read by HiCORDER, it is recommended that text data conversion be performed on PCs. Memory / main unit Floppy disk Memory / main unit Flash ATA card Data compatibility with the model 8730/8731 The MEMORY HiCORDER 8835 - 01 is judgment area and waveform data compatible with HIOKI WAVE COMPARATORs 8730/8731. The 8835 - 01 lends itself to detailed analysis and printing of waveform judgment data on production lines. Waveform judgment screen on the 8835-01 (* Waveform data is binary data within 500 DIV.) (* The waveform judgment function of the 8835-01 must be upgraded with the FUNCTION UP DISK 9540-01.) Waveform judgment screen on the 8731 6 - Function Details - Trigger functions for monitoring of all four channels In all of the functions, including the memory recorder and recorder, all eight analog input channels and sixteen logic input channels can be used for trigger input. In addition to a level trigger, which compares voltages based on a reference value, the 8835 -01 supports the following triggers. ● Window trigger that compares voltages based on two reference values ● Voltage-drop detection trigger that detects voltage drops in commercial power lines ● RMS-value level trigger that compares signals based on the RMS-value level ● Period detection trigger that measures periods and detects all deviating periods ● Pattern trigger that compares signals based on the logic signal ON/OFF pattern Variable (span adjustment), vernier (fine adjustment) W hen sensors a re used to measu re a nd record noise, temperature, acceleration or other physical quantities, precise calibration is important. This is facilitated by the vernier function that allows fine adjustment of amplitude. The variable function lets the user numerically specify the measurement span, such as 1 - 5V or 4 - 20mA. This is useful for matching the range of instrumentation to the full span of the recording paper. A scaling function for converting measurement results is also available. Manipulation using the cursor Use of the two cursors on the screen enables the user to read the time difference and potential difference. Signal outputs, control inputs, DC input The results of waveform decisions, parameter decisions, and triggers are output as open collector signals. The 8835-01 is also provided with signal inputs for remote control of the start, stop, and print buttons. The 8835 -01 has a dual AC/DC power-supply specification, and an external battery can be used by means of the DC POWER ADAPTER 9439, in addition to normal AC power supply. This allows vehicle-mounted applications, where an AC power supply is not available. If both supplies are connected, the AC power supply takes precedence, but if the AC power fails, the unit automatically switches to DC operation. DC input (The DC POWER ADAPTER 9439 must be used) External trigger input External control connector Trigger signal output Judgment outputs * When using the F/V UNIT 8940 with 12 V DC power, the printer can only be used for up to 2 channels. 7 Upgrading provides sophisticated functions Additional functions provided by the FUNCTION UP DISK 9540-01 (with the 8835, use the FUNCTION UP DISK 9540) Recorder and memory functions If an abnormal event is detected by triggers during the realtime recording of signals using the recorder function, it is stored in memory by the high-speed sampling memory recorder. The recorder function works independently and is therefore continuous. These functions are useful when the user wants to record normal waveforms as well as abnormal waveforms. FFT analysis functions The single-channel FFT function is used in spectrum analysis. The two-channel FFT function analyzes transfer functions. The octave analysis function is used in acoustic analysis. The signal source for FFT analysis is a section obtained from the waveforms captured in the memory recorder (the required number of pieces of data for FFT analysis are 1000, 2000, 5000 and 10000). Waveform judgment functions *In memory recorder functions and FFT analysis functions The 8835 -01 can monitor a measured waveform for a preset judgment area. Unlike a voltage level only comparison such as a trigger setting, this function makes it possible to easily prepare a standard judgment area making it an excellent system for comparisons both in level direction and in time axis direction. Patented: Registration number 2028013 The 8835 -01 is waveform data and area data compatible with the WAVE COMPARATOR 8730 and 8731. (* Wavefor m data is bina r y data within 50 0 DIV. The 873 0 and 8731 comparators do not provide an FFT analysis function.) Simultaneous computation on eight channels It is possible to simultaneously compute four different types of waveforms, each of which has been captured on one of the eight channels in memory recorder mode. The results of four basic arithmetic computations, differentiation, or integral are displayed in a waveform. (The waveform computation requires a FUNCTION UP DISK. 9540 -01 With the 8835, the waveform computation requires a FUNCTION UP DISK 9540.) For parameter calculations that calculate numerical values such as the maximum and minimum values, up to eight waveforms can be operated simultaneously on four channels. (The parameter operations are a standard function.) Waveform judgment screen on the 8835-01 Waveform judgment screen on the 8731 8 Example Printouts (Actual size) Sample recording in memory recorder function (full width) The recording width can also be divided into two or four parts, and X-Y plots are possible. Sample recording (two sections) Sample recording in X-Y format * Example when used with 1-4 channels set Synthesized X-Y waveforms can be output where amplitude data for each input channel is plotted on the vertical and horizontal axes, based on the waveform data obtained using the memory recorder. The recording size is 100 mm × 100 mm. Although the sample print out is in Japanese, the actual print out appears in English. (Two languages selectable) Sample recording (four sections) Full-width recordings and recordings divided into two or four parts are also possible. Logging output * Example when used with 1-4 channels set Instantaneous voltage values are printed for each sampling. Although the sample print out is in Japanese, the actual print out appears in English. (Two languages selectable) PC card slot for type-III cards A PC card-type GP-IB or RS-232C interface is used for this slot as well. Waveform monitor (color TFT LCD) Floppy-disk drive External control terminal DC power inlet Connect the optional DC POWER ADAPTER 8439 AC power inlet Logic probes input terminals Analog input unit mount Thermal printer: 110 mm in width, 8 dots/mm Basic specifications 8835 -01 (use 2ch input type modules) 8835 -01 (use 4ch ANALOG UNIT 8946) Input type/number of channels Plug-in input modules Max. 4 analog chʼs + 16 logic chʼs (Isolated analog channels, isolated input and frame, logic has common GND) Plug-in input modules Max. 8 analog chʼs + 16 logic chʼs (Isolated analog channels, isolated input and frame, logic has common GND) Measurement functions MEM (high-speed recording) REC (real-time recording) RMS (50/60Hz, or DC only) REC & MEM (Additional functions provided by the optional FUNCTION UP DISK 9540-01) FFT (Additional functions provided by the optional FUNCTION UP DISK 9540-01) Maximum sampling rate 1 MS/second (1μs, all channels simultaneously) External sampling (500kS/second, 2μs) Memory capacity Data storage media Interfaces (option) (12 analog bits + 4 logic bits) × 4 Mwords/channel (1 channel used) to (12 analog bits + 4 logic bits) × 500 kwords/channel (8 channels used) PC Card Type III slot × 1: up to 1GB (Flash ATA) 3.5" Floppy disk drive × 1: 1.44MB, 1.2MB, 720KB, MS-DOS format File format: Binary, text, BMP Mini-jack 3.5 mm in dia.: Trigger input/output Terminal board: External start, stop, print input/sampling input, decision output Note: Use one of the following: RS-232C CARD 9557, GP-IB CARD 9558, LAN CARD (HIOKI-tested) Compliance standard Safety: EN61010 EMC: EN61326, EN61000-3-2, EN61000-3-3 Power requirements 100 to 120V AC or 200 to 240V AC (50/60 Hz) 10 to 28V DC (use the DC POWER ADAPTER 9439 : option) Power consumption 120VA, max. for 100V AC (approx. 60VA with the printer off) 70VA, max. for 12V DC (approx. 30VA with the printer off) Power consumption (when using two units of 8940) 100μs to 5min/DIV, 20 ranges or external sampling, time axis resolution 100 points/DIV, time axis zoom: ×2 to ×10 in 3 stages, compression: 1/2 to 1/2,000 in 10 stages Sampling rate 1/100 of time axis ranges (minimum sampling period 1μs) External sampling Max. 500kS/s (minimum sampling period 2μs) Settable in 1 DIV steps, 20 to 40,000 DIV*1 Recording length *1 Depending on the number of channels in use. Pre-trigger Can record data from before the trigger point, 0 to 100% or -95% of recording length; 15 settings Other functions waveform processing*2, waveform parameter processing, waveform averaging*2, memory segmentation (up to 255 segments)*2, logging (numerical printout), X-Y waveform plot, voltage axis zoom ×2 to × 10, 3 settings, compression 1/2, zoom, variable display, graph superimposition, waveform judgment function*2 *2 Additional functions provided by the optional FUNCTION UP DISK 9540-01 Recorder functions (time axis waveform and X-Y format) 10ms to 1 hour/DIV with 17 ranges, time axis resolution 100 points/ DIV, time axis compression: 1/2 to 1/50 in 5 stages Time axis At 10ms to 200ms/DIV, printing in real time is not possible, but waveform data are stored in memory and can be monitored on screen. Data are stored for 2,000 divisions before the end of measurement. At recording length settings other than "Continuous", the printer can be used simultaneously, for follow-up printing of waveforms. Sampling rate 1μs to 100ms; 6 settings (selectable from 1/100 or less of time axis) Recording length Settable in 1 DIV steps, 20 to 2,000 DIV*3, or "Continuous"*4 At X-Y format: only continuous for X-Y plotting GP-IB, RS-232C, LAN Environmental conditions Operation: +5°C (41°F) to +40°C (104°F), 35% to 80% rh (no condensation) Storage: -10°C (14°F) to +50°C (122°F), 20% to 90% rh (when using two units of 8936) Time axis 4 Mwords total Clock and setting conditions: battery life of at least 10 years Backup functions Waveform data: battery life of at least 1 hour after system power is (at 25°C) turned OFF (at 2 minutes after power-on) External control connectors Memory functions 170VA, max. for 100V AC (approx. 110VA with the printer off) 80VA, max. for 12V DC (approx. 50VA with the printer off) Note: When using the F/V UNIT 8940 with 12V DC power, the printer can only be used for up to 2 channels. Dimensions and mass 285mm (11.22in) W × 220mm (8.66in) H × 132mm (5.20in) D, 4.5kg Supplied accessories Instruction Manual × 1, Power cord × 1, Printer paper ×1, Protective cover ×1, Roll paper attachment ×2, PC card protector ×1, Application Disk (Wave Viewer Wv, Communication Commands table) ×1 (158.73oz.) (main unit only) X-Y sampling period 100μs; fixed (dot), 100μs to 25ms (line) X-Y axis resolution 40dots/DIV (display), 80dots (horizontal) × 80 dots (vertical)/DIV (printer) Waveform memory Store data for most recent 2,000 DIV in memory. Backward scrolling and re-printing available. Other functions logging (numerical printout), additional recording (recording is resumed without overwriting previous data), voltage axis magnification ×2 to ×10; 3 settings, compression 1/2; 1 setting, variable display. RMS Recorder Function (for 50/60 Hz and DC) Time axis 5s to 1 hr/DIV; 9 settings, time axis compression 1/2 to 50; 5 settings Sampling rate 200μs fixed (20 rms datas/s) RMS calculation accuracy ±3% f.s. Settable in 1 DIV steps, 20 to 2,000 DIV*5, or "Continuous" Recording length *5 Measure all channels. Waveform memory Store data for most recent 2,000 DIV in memory. Backward scrolling and re-printing available. Other functions logging (numerical printout), additional recording (recording is resumed without overwriting previous data), voltage axis magnification ×2 to ×10; 3 settings, compression 1/2; 1 setting, variable display. Print/display section Display 6.4 inch TFT color LCD, with English/Japanese selector (640 × 480 dots) Recording paper 110 mm (4.33 in) × 30 m (98.4 ft), thermal paper roll Recording width 10 divisions for full scale, 1 DIV = 10 mm (0.39 in) (80 dots) Paper feed density 10 rows/mm (250 rows/in) * 20 rows/mm (500 rows/in with the memory Recording speed recorder's smooth print function Max. 25 mm/s (0.98 in/s) Auxiliary Functions General Trigger functions Trigger sources Trigger types (analog) CH1 to CH8 (analog), CHA to CHD (logic), external, timer, manual (either ON or OFF for each source), logical AND/OR of sources Level: Digital setting of voltage. Triggered when set value is exceeded in UP or DOWN direction. Window: When entering or exiting a level range defined by upper or lower limit Voltage drop: Only for AC power lines. Triggered when the peak voltage falls below setting value RMS level: Only for DC and AC power lines. Triggered when rms value crosses set value in UP or DOWN direction Period: When rising or falling edge of set voltage does not fall within cycle range Scaling Vernier function Pattern trigger: 1, 0, or × (disregard), logical product (AND) or logical sum (OR) set for 4 channels Trigger filter OFF, setting range 0.1 to 10.0 DIV in 9 stages (MEM, REC & MEM function), ON/OFF (REC function) (logic) (analog/logic) Other functions Pre-trigger function to capture pre- and post-trigger waveform, trigger output (active Low with φ 3.5mm mini-jack and open collector 5 voltage output), Start & stop trigger in REC function Printing of settings including input range, trigger time, etc, cursor measurement, scaling, free comment input, screen hard copy, registration of setting conditions (eight conditions), start condition retention, auto setup, auto saving, remote control, auto ranging, view function, online help, key lock, list printing, etc. Scaling: Translation of amplitude gradation only Variable: Arbitrary setting of the upper and lower limit of the waveform display range Allows precision adjustment of input voltage. Average value, effective (rms) value, peak to peak value, maximum Waveform parameter value, time to maximum value, minimum value, time to minimum calculation value, period, frequency, rise time, fall time, area value, X-Y area (in MEM function) value, and standard deviation. ■ PC Software Specifications Wave Viewer (Wv) Software (Application disk CD-R, bundled accessory) Level setting resolution Equivalent to 0.25% when full scale is set to 10 divisions Trigger types *3 Measure all channels. *4 When time 10 ms − 200 ms/DIV and printer is ON, continuous is not available. Functions • Simple display of waveform file • Text conversion: convert binary data file to text format, with selectable space or tab separators in addition to CSV, and specifiable section, thinning available • Display format settings: scroll functions, enlarge/reduce display, display channel settings • Others: voltage value trace function, jump to cursor/trigger position function Compatible PC operating systems Windows 95/98/Me, Windows NT 4.0 (SP3 or later), 2000, XP 9 10 ■ Options (sold separately) FUNCTION UP DISK 9540 -01 Additional functions to the MEMORY HiCORDER 8835-01 REC & MEM functions Additional functions provided by the FUNCTION UP DISK 9540-01 Time axis (REC) 500ms to 1hour/DIV; 17 settings, 1 DIV = 100 samples, time axis compression 1/2 to 1/50, 5 settings Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 300 g (10.6 oz) Accessories: None VOLTAGE/TEMP UNIT 8937 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 1 hour of warm-up time and zero-adjust; accuracy guaranteed for 1 year) Measurement functions Number of channels: 2, for voltage measurement/temperature measurement with thermocouple Voltage input: metallic BNC connector (input impedance 1MΩ, input capacitance 50pF), Input connectors thermocouple input: terminal connector (input impedance min. 5.1MΩ), Max. rated voltage to earth: 30Vrms or 60V DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) Note: Sampling period 1/100 of time axis range at MEM function Time axis (MEM) 100μs to 5 minutes/DIV; 20 settings, 1 DIV = 100 samples, time axis zoom ×2 to ×10; 3 settings, compression 1/2 to 1/2000, 10 settings Voltage measurement range 1mV to 5V/DIV, 12 ranges, full scale: 10DIV, low-pass filter: 5Hz/ 500Hz/ 5kHz/ 100kHz, Measurement resolution: 1/160 of measurement range (using 12-bit A/D conversion; installed in the 8835-01) Recording length REC: Settable in 1-division steps, 20 to 1,000 DIV, or continuous MEM: Settable in 1-division steps, 20 to 2,000 DIV Temperature measurement range 20°C to 200°C/DIV, 4 ranges, full scale: 10DIV, low-pass filter: 5Hz/500Hz, Measurement resolution:1/160 of measurement range Trigger source REC: timer trigger, or OFF MEM: CH1 to CH8 (analog), logic A to D, or external trigger K: -200 to 1350°C, E: -200 to 800°C, J: -200 to 1100°C, T: -200 to 400°C, N: -200 to 1300°C, R: 0 to 1700°C, S: 0 to 1700°C, B: 300 to 1800°C, Reference junction compensation: internal/ external (switchable) Other functions Only real-time waveform is output when printer output is started, reprinting of stored REC waveform data (last 1000 DIV), Additional recording function (recording is resumed without overwriting previous data), variable display Thermocouple range Highest sampling rate Voltage input: 1MS/s, Temperature measurement: 4kS/s Accuracy Voltage input: DC amplitude ±0.4% of full scale, zero position ±0.15% of full scale, Temperature measurement (K, E, J, T, N): ±0.1% of full scale ±1°C, ±0.1% of full scale ±2°C (-200 to 0°C), (R, S): ±0.1% of full scale ±3°C, (B): ±0.1% of full scale ±4°C (400 to 1800°C) , Reference junction compensation accuracy: ±0.1% of full scale ±1.5 °C (internal reference junction compensation) Frequency characteristics Voltage input: DC to 400 kHz +1/−3dB Temperature measurement: DC to 1kHz +1/−3dB Input coupling DC, GND, AC Max. allowable input 30Vrms or 60V DC (the maximum voltage that can be applied across input pins without damage) Note: Sampling period 1/100 of time axis range (min. 1μs) FFT functions Additional functions provided by the FUNCTION UP DISK 9540-01 Analysis mode Storage waveform, Linear spectrum, RMS spectrum, Power spectrum, Cross-power spectrum, Auto-correlation function, Histogram, Transfer function, Cross-correlation function, Unitimpulse response, Coherence function, Octave analysis Analysis channels 1 or 2 selected channels out of all analog channels (using 12-bit A/D conversion; installed in the 8835-01) (simultaneous sampling in 2 channels) Frequency range 133mHz to 400kHz, External, (resolution 1/400, 1/800, 1/2000, 1/4000) Number of sampling points 1000, 2000, 5000, 10000 points Analysis data Selected from: Newly loaded data / MEM function waveform data / MEM waveform of REC & MEM function Windows Rectangular, Hanning, Exponential STRAIN UNIT 8939 Time axis / frequency axis simple averaging, exponential averaging, peak hold Measurement functions Number of channels: 2, for distortion measurement (electronic Input connectors Via conversion cable, TAJIMI PRC03-12A10-7M10.5, Max. rated voltage to earth: 30Vrms or 60V DC (with input isolated from the unit, the maximum voltage that can Suitable transducer Strain gauge converter, bridge impedance: 120Ω to 1kΩ, bridge voltage 2 ±0.05V Measurement range 50με to 2000με/DIV, 6 ranges, full scale: 10DIV, low-pass filter: 10Hz/30Hz/300Hz/3kHz Averaging function Additional features Additional functions provided by the FUNCTION UP DISK 9540-01 Waveform processing calculations (MEM function) (Maximum possible calculation up to 1000 DIV; accuracy is within the tolerance of the input module.) Four arithmetic operations, absolute value, exponentiation, common logarithm, square root, moving average, differentiation once and twice, integration once and twice, parallel displacement along the time axis. 8 arbitrary operational equation. (MEM function) (FFT function) Type: Area judgment using reference waveform for time axis waveform, X-Y plot, or FFT display. Parameter judgment for waveform parameter processing. Judgment output: pass/fail output, open-collector 5V voltage output Others Waveform averaging; memory segmentation (up to 255 segments) Waveform judgment function Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 250 g (8.8 oz) Accessories: Conversion cable × 2 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 1 hour of warm-up time and auto-balance; accuracy guaranteed for 1 year) auto-balancing, balance adjustment range within ±10000με) be applied between input channel and chassis and between input channels without damage) Measurement resolution 1/160 of measurement range (using 12-bit A/D conversion; installed in 8835-01) Highest sampling rate 1MS/s (2-channel simultaneous sampling) Accuracy After auto-balancing DC amplitude: ±(0.5% of full scale +2με), zero position: ±0.5% of full scale Frequency characteristics DC to 20 kHz +1/−3dB Max. allowable input 10V DC + AC peak (the maximum voltage that can be applied across input pins without damage) CONVERSION CABLE 9318 (to connect 9270 to 9272, 9277 to 9279 and 8940) CONVERSION CABLE 9319 (to connect 3273, 3273-50 and 8940) Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 300 g (10.6 oz) Accessories: None ■ Input unit specifications (sold separately) Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 290 g (10.2 oz) Accessories: None ANALOG UNIT 8936 Input connectors Measurement functions Number of channels: 2, for voltage input based frequency measurement, integration, pulse duty ratio, current (with optional clamp-on sensor), and voltage measurement Input connectors Metallic BNC connector (input impedance 1MΩ, input capacitance 60pF), sensor connector (dedicated connector for clamp-on sensor via conversion cable, common ground with recorder), Max. rated voltage to earth: 30Vrms or 60V DC (with (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 30 minutes of warm-up time and zero-adjust; accuracy guaranteed for 1 year) Measurement functions Number of channels: 2, for voltage measurement Isolated BNC connector (input impedance 1MΩ, input capacitance 30pF), Max. rated voltage to earth: 370V AC, DC (with input isolated from the unit, the maximum voltage that 10mV to 50V/DIV, 12 ranges, full scale: 10DIV, AC voltage for possible measurement/display using the memory function: 280V rms, low-pass filter: 5Hz/500Hz/5kHz/100kHz Measurement range Measurement resolution 1/160 of measurement range (using 12-bit A/D conversion; installed in the 8835-01) Highest sampling rate 1MS/s (simultaneous sampling in 2 channels) Accuracy DC amplitude: ±0.4% of full scale, zero position: ±0.1% of full scale (after zero adjustment) DC, GND, AC Max. allowable input 400V DC (the maximum voltage that can be applied across input pins without damage) maximum voltage that can be applied across input pins without damage) FFT ANALOG UNIT 8938 from the 8940, max. 4 sensors total) Measurement range Anti-aliasing filter Integrated filter for suppressing aliasing distortion caused by FFT processing (automatic cutoff frequency setting/OFF) Other functions Other specifications same as the ANALOG UNIT 8936 DC amplitude accuracy: ±0.4% of full scale, zero position ±0.15% of full scale (current measurement accuracy dependent on sensor accuracy/ characteristics) Frequency characteristics: DC to 400kHz ±3dB Full scale: 10DIV, Max. allowable input: 30Vrms or 60V DC (the (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 30 minutes of warm-up time and zero-adjust; accuracy guaranteed for 1 year) Measurement functions Number of channels: 2, for voltage measurement Frequency: DC to 100kHz, with 0.1Hz to 10kHz/DIV, 11 ranges, 10 (r/ min) to 1k (r/min)/DIV, 5ranges, P50Hz (40 to 60Hz), P60Hz (50 to 70Hz) * Power line frequency measurement requires the DIFFERENTIAL PROBE 9322 or PT 9303 , Accuracy: ±0.2% of full scale (except 10kHz/DIV range), ±0.7% of full scale (10kHz/DIV range), ±0.032Hz (P50Hz, P60Hz range) Integration: DC to 90kHz, with 10counts to 1Mcounts/DIV, 11 ranges Pulse duty ratio: 10Hz to 100kHz, with 100% of full scale, 1 range, Accuracy: ±1% of full scale (10Hz to 10kHz) Threshold: −10 to +10V (settable in 0.2V steps) Full scale: 10DIV, Max. allowable input: 30Vrms or 60V DC (the Voltage: 1mV to 5V/DIV, 12 ranges Current: 10mA to 200A/DIV, 10 ranges, using current sensor (powered Frequency characteristics DC to 400kHz ±3dB, with AC coupling: 7Hz to 400kHz ±3dB Input coupling input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) Compatible current sensors 9270, 9271, 9272, 9277, 9278, 9279, 3273, 3273 -50 can be applied between input channel and chassis and between input channels without damage) Measurement range (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 30 minutes of warm-up time and zero-adjust; accuracy guaranteed for 1 year) F/V UNIT 8940 maximum voltage that can be applied across input pins without damage) Measurement resolution 1/160 of measurement range (installed in 8835-01, excluding current range when using 9279) 1MS/s (simultaneous sampling in 2 channels), (frequency/duty ratio Highest sampling rate measurement: 1.125μs cycle) Other functions Voltage input pull-up: ON (10kΩ)/OFF, input coupling: DC, GND, AC (voltage/current), DC (others), low-pass filter: 5Hz/500Hz/5kHz/100kHz * The 8940 can be used with the 8835-01. but the 8835, main unit only, current probe cannot be used. The 8940 can be used with the 8835 standard models later than Ver. 2.10, 9540 install models later than Ver.5.10 can be used. 11 Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 310 g (10.9 oz) Accessories: None (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 30 minutes of warm-up time and zero-adjust; accuracy guaranteed for 1 year) 4ch ANALOG UNIT 8946 Measurement functions Number of channels: 4, for voltage measurement Input connectors Metallic BNC connector (input impedance 1MΩ, input capacitance 15pF), Max. rated voltage to earth: 30Vrms or 60V DC (with input isolated Measurement range 20mV to 5V/DIV, 8 ranges, full scale: 10DIV, low-pass filter, 5Hz/500Hz/5kHz/50kHz, input coupling: DC, GND from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) Measurement resolution 1/160 of measurement range (using 12-bit A/D conversion; installed in the 8835-01) Highest sampling rate 1MS/s (simultaneous sampling in 4 channels) Accuracy DC amplitude: ±0.5% of full scale, zero position: ±0.15% of full scale (after zero adjustment) Frequency characteristics DC to 100kHz ±3dB Max. allowable input 30Vrms or 60V DC (the maximum voltage that can be applied across input pins without damage) Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 310 g (10.9 oz) Accessories: None CHARGE UNIT 8947 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80 % rh after 1 hour of warm-up time and zero-adjust; accuracy guaranteed for 1 year) Measurement functions Number of channels: 2, for acceleration measurement Voltage input/integrated preamplifier input: metallic BNC connector Input connectors Suitable transducer Measurement range Charge input (miniature connector) Internal pre-amp input (BNC connector) Measurement range Voltage input (BNC connector) (for voltage input: input impedance 1MΩ, input capacitance 200pF or less) Charge input: miniature connector (#10-32 UNF) Max. rated voltage to earth: 30Vrms or 60V DC (with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) Charge input: Charge-output type piezoelectric acceleration pick-up sensor Internal preamp input: Acceleration pick-up sensor with an internal preamp 100m (m/s2)/DIV to 20k (m/s2)/DIV, 12 ranges × 6 types, charge input sensitivity: 0.1 to 10 pC/(m/s2), integrated pre-amplifier input: 0.1 to 10 mV/(m/s2), amplitude accuracy: ±2% of full scale, frequency characteristics: 1 to 50kHz, +1/−3dB, low-pass filter: 500Hz/5kHz, pre-amplifier drive power source: 2mA ±20%, +15V ±5%, maximum input charge: ±500pC (high-sensitivity setting, 6 ranges), ±50000pC (low-sensitivity setting, 6 ranges) 1mV to 5V/DIV, 12 ranges, DC amplitude accuracy: ±0.4% of full scale, frequency characteristics: DC to 400kHz, +1/−3 dB, low-pass filter: 5Hz/500Hz/5kHz/100kHz, input coupling: DC, GND, AC, Max. allowable input: 30Vrms or 60V DC 1/160 to 1/64 of measurement range (depending on measurement Measurement resolution sensitivity; installed in the 8835-01) Highest sampling rate 1MS/s (simultaneous sampling in 2 channels) Integrated filter for suppressing aliasing distortion caused by FFT Anti-aliasing filter processing (automatic cutoff frequency setting/OFF) Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft), approx. 150 g (5.3 oz) LOGIC PROBE 9320 (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year) Function Detection of voltage signal or relay contact signal for High/Low state recording Input 4 channels (common ground between unit and channels), digital/contact input, switchable (contact input can detect open-collector signals), input impedance: 1MΩ (with digital input, 0 to +5V), 500kΩ or more (with digital input, +5 to +50V), pull-up resistance: 2kΩ (contact input: internally pulled up to +5V) Digital input threshold 1.4V/2.5V/4.0V Contact input detection resistance 1.5kΩ or higher (open) and 500Ω or lower (short), 3.5kΩ or higher (open) and 1.5kΩ or lower (short), 25kΩ or higher (open) and 8kΩ or lower (short) Response speed Detectable pulse width 500ns or lower Max. allowable input 0 to +50V DC (the maximum voltage that can be applied across input pins without damage) Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx. 320 g (11.3 oz) LOGIC PROBE 9321 Function Input (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed for 1 year) Detection of AC or DC relay drive signal for High/Low state recording Can also be used for power line interruption detection 4 channels (isolated between unit and channels), HIGH/LOW range switching Input impedance: 100kΩ or higher (HIGH range), 30kΩ or higher (LOW range) LAN COMMUNICATOR 9333 Distribution media One CD-R Operating environment Computer equipped with Pentium (133 MHz) or better CPU, running under Windows 95/98/Me or Windows NT 4.0/ 2000/XP operating system, with network adapter installed and configured to use TCP/IP protocol, and at least 64 MB of memory. HiCORDER side Standard LAN connector, LAN card Output (H) detection 170 to 250V AC, ±DC (70 to 250V ) (HIGH range) 60 to 150V AC, ±DC (20 to 150V) (LOW range) Communications Ethernet, TCP/IP Output (L) detection 0 to 30V AC, ±DC (0 to 43V) (HIGH range) 0 to 10V AC, ±DC (0 to 15V) (LOW range) Remote control Response time Rising edge 1ms max., falling edge 3ms max. (with HIGH range at 200V DC, LOW range at 100V DC) Maximum allowable 250Vrms (HIGH range), 150Vrms (LOW range) (the maximum voltage that can be applied across input pins without damage) input voltage Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft), approx. 350 g (12.3 oz) DIFFERENTIAL PROBE 9322 Function Waveform data acquisition Waveform viewer Remote control of MEMORY HiCORDER (by sending key codes and receiving print reports, print images from the screen, receive waveform data in same format as waveform files from the MEMORY HiCORDER (binary only) Accept auto-saves from the MEMORY HiCORDER, same format as auto-save files of MEMORY HiCORDER (binary only), print automatically with a MEMORY HiCORDER from a PC. The MEMORY HiCORDER's print key launches printouts on the PC images on screen) , Simple display of waveform files, conversion to CSV format, Scroll function, enlarge/reduce display, display CH settings. (Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of warm-up time; accuracy guaranteed for 1 year) For high-voltage floating measurement, power line surge noise detection, RMS rectified output measurement DC mode For waveform monitor output, frequency characteristics: DC to 10MHz (±3dB), amplitude accuracy: ±1% of full scale (at max. 1000V DC), ±3% of full scale (at max. 2000V DC) (full scale: 2000V DC) AC mode For detection of power line surge noise, frequency characteristics: 1kHz to 10MHz ±3dB RMS mode DC/AC voltage RMS output detection, frequency characteristics: DC, 40Hz to 100kHz, response speed: 200ms or less (400V AC), accuracy: ±1% of full scale (DC, 40Hz to 1kHz), ±4% of full scale (1kHz to 100kHz) (full scale: 1000V AC) Input Input type: balanced differential input, input impedance/capacitance: H-L 9MΩ/10pF, H/L-unit 4.5MΩ/20pF, Max. rated voltage to earth: when using grabber clip 1500V AC/DC (CAT II ), 600V AC/DC (CAT III), when using alligator clip: 1000V AC/DC (CAT II), 600V AC/DC (CAT III) Maximum allowable 2000V DC, 1000V AC (CAT II) 600V AC/DC (CAT III) input voltage Output Voltage divider for 1/1000 of input, BNC connectors (output switchable for Power source Use of the AC ADAPTER 9418 -15 (12V DC) 3 modes DC, AC, RMS) WAVE PROCESSOR 9335 Distribution media One CD-R Operating environment Computer equipped with Pentium (133 MHz) or better CPU and at least 32 MB of memory, and running under Windows 95/98/Me, Windows NT 4.0/2000/XP, or Windows Vista 32-bit type (recommended system: Pentium (200 MHz) or better with at least 64 MB of memory) Display functions Waveform display/X-Y display/digital value display/cursor function/ scroll function/maximum number of channels (32 channels analog, 32 channels logic)/gauge display (time, voltage axes)/graphical display File loading Readable data formats (.MEM, .REC, .RMS, .POW) Maximum loadable file size: Maximum file size that can be saved by a given device (file size may be limited depending on the computer configuration) Data conversion Conversion to CSV format, tab delimited, space delimited/data culling (simple)/convert for specified channel/batch conversion of multiple files Print functions Print formatting (1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up) /preview/ hard copy functions usable on any printer supported by operating system Other Parameter calculation/search/clipboard copy/launching of other applications 12 Composition of options Note: Product names appearing herein are trademarks or registered trademarks of various companies. Logic signal measurement Input modules Install by inserting into the main unit. Can be replaced by user. Note: Input cables are not supplied. Please purchase the appropriate cable for the intended application. ANALOG UNIT 8936 VOLTAGE/TEMP UNIT 8937 FFT ANALOG UNIT 8938 STRAIN UNIT 8939 F/V UNIT 8940 4ch ANALOG UNIT 8946 (The 8946 can be used with the LOGIC PROBE 9320 LOGIC PROBE 9321 4-channel type, for voltage/contact signal ON/OFF detection 8835-01, but cannot be used with the 8835.) 4 isolated channels, ON/OFF detection of AC/DC voltage Current measurement * The 3274, 3275, and 3276 cannot be used for the F/V UNIT 8940 CHARGE UNIT 8947 F/V UNIT 8940 Voltage measurement 9279 Not CE certified 3273-50 9277 CONVERSION CABLE 9318 (to connect 9277 - 9279 and 8940) 9278 CONVERSION CABLE 9319 (to connect 3273-50 and 8940) UNIVERSAL CLAMP ON CT 9277 CLAMP ON PROBE 3273-50 DC to 50MHz wideband response, Observe waveforms from DC to distorted mA-class current up to 30A rms AC. DC to 100kHz response, input 20A / output 2V AC CONVERSION CABLE 9319 to connect 3273-50 and 8940 PROBE 9322 CONNECTION CORD DIFFERENTIAL For up to 2kV DC or 1kV AC, AC adapter 9197 9418-15 required for operation. UNIVERSAL CLAMP ON CT 9278 Observe waveforms from DC to distorted AC. DC to 100kHz response, input 200A / output 2V AC For high voltage (up to 500V) AC ADAPTER 9418-15 For powering Differential probe 9322, 100 to 240V AC, 12V/2.5 A CONNECTION CORD 9198 For low voltage (up to 300V) POWER CORD 9324 Use to the 9322 from the logic terminal. * Note that usage restrictions apply. POWER CORD 9325 Observe waveforms from DC to distorted AC. DC to 20kHz response, input 500A / output 2V AC MEMORY HiCORDER 8835-01 (main unit) * The MEMORY HiCORDER 8835-01 cannot operate alone. F/V UNIT 8940 CLAMP ON SENSOR 9271 5Hz to 50kHz response, up to 200A rms, 2V AC output Insulation transformer, 400V or 200V AC input, 10V AC output, for AC power line measurement. Input from 10 to 500A, 40Hz to 3kHz for 0.2V AC output. BNC terminal 1Hz to 100kHz response, selectable 20 and CLAMP ON PROBE 9132-10 Input from 20 to 1000A, 40Hz to 1kHz for 0.2V AC output. BNC terminal, Not CE certified. 200A rms ranges, 2V AC output CONVERSION CABLE 9318 Not CE certified CLAMP ON LEAK SENSOR 9657-10 to connect 9270/9271/9272 and 8940 TRIGGER CORD 9305 Supplied with PC Card adapter CONVERSION ADAPTER 9199 Banana-to-BNC, use to connect to insulation-BNC terminal on Input section PC Card Precaution Communication 3274 3275 3272 3273-50 3276 3269 CLAMP ON PROBE 3273-50 CLAMP ON PROBE 3276 CLAMP ON PROBE 3274 POWER SUPPLY 3272 CLAMP ON PROBE 3275 POWER SUPPLY 3269 DC to 50MHz wideband response, mA-class current up to 30A rms DC to 10MHz wideband response, mA-class current up to 150A rms DC to 2MHz wideband response, mA-class current up to 500A rms DC to 100MHz wideband response, mA-class current up to 30A rms Connect and power up to one Clamp-On Probes to use in combination with voltage input modules (up to two PROBEs restrictively) Connect and power up to four Clamp-On Probes to use in combination with voltage input modules For leak current only, 10A for rated current, 40Hz to 5kHz, output rate 100mV/A AC, BNC terminal φ 3.5mm (0.14in) mini-plug, 1.5m (4.92 ft) length Printing Model 9555-10 is required to power the ClampOn CTs, except for connecting Clamp-On CT Model 9277/78/79 to Model 8940, and for signal output, Model 9217 Connection Cord is required to connect for input modules. to connect 9277/9278/9279 and 8940 9555-10 CLAMP ON PROBE 9018-10 CLAMP ON SENSOR 9272-10 CONNECTION CORD 9165 Metal BNC connectors at both ends, and connects to metal BNC connectors 9272-10 9270, 9271 Not CE certified SENSOR UNIT 9555-10 CONVERSION CABLE 9318 (to connect 9270 - 9272 and 8940) Model 9555-10 is required to power the Clamp-On CLAMP ON SENSOR 9270 Sensors, except for connecting Clamp-On Sensor 5Hz to 50kHz response, up to 20A rms, 2V Model 9270, 9271, 9272-10 to Model 8940, and for signal output, Model 9217 Connection Cord is AC output required to connect for input modules. PT 9303 Not CE certified SENSOR UNIT 9555-10 CONVERSION CABLE 9318 Current measurement Not CE certified Insulated BNC connectors at both ends, and connects to insulated BNC connectors Cord has insulated BNC connectors at both ends, and connects to the 9555-10 and input moduls. UNIVERSAL CLAMP ON CT 9279 Use to the 9322 from the F/V UNIT 8940. * Note that usage restrictions apply. CONNECTION CORD 9217 CONNECTION CORD 9217 U s e o n l y P C C a rd s s o l d by HIOKI . Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards. PC CARD 128M 9726 (128 MB capacity) PC CARD 256M 9727 (256 MB capacity) PC CARD 512M 9728 (512 MB capacity) PC CARD 1G 9729 (1 GB capacity) FUNCTION UP DISK 9540 -01 For the model 8835-01, use the FUNCTION UP DISK 9540 with the the model 8835. DC POWER ADAPTER 9439 CARRYING CASE 9388 Supplies operating power in the range 10 to 28V DC. With casters for convenient transportation. RECORDING PAPER 9221 110 mm (4.33 in) × 30 m (98.43 ft), 10 rolls set Not CE certified Not CE certified PAPER WINDER 220H Paper width 70mm (2.75 in) to 220mm (8.66 in), using specialpurpose AC adapter RS-232C CARD 9557 GP-IB CARD 9558 LAN CARD PCMCIA-compliant May not operate depending on the environment., 10BASE-T PCMCIA-compliant, cord length: 2m (6.6ft) LAN CABLE 9642 LAN COMMUNICATOR 9333 WAVE PROCESSOR 9335 Application software to create a LAN Supplied with cross conversion connection with Windows 95/98/Me, or cable, straight Ethernet cable, Windows NT 4.0/2000/XP. length: 5m (16.4ft) Data conversion, print functions, waveform display, compatible with Windows 95/98/Me, Windows NT 4.0/2000/XP, and Windows Vista 32-bit type. ■ Combination example: 8835-01 (normal choice of the input unit, up to 200V AC direct input.) Model number × quantity Input cable Main unit 8835-01×1 Memory 4MW standard 2ch 8936×1 9198×2 4ch 8936×2 9198×4 ■ Combination example: 8835-01 (select an automotive input unit that can handle up to 30 V AC.) Model number × quantity Input cable Main unit 8835-01×1 Memory 4MW standard 4ch 8946×1 9198×4 8ch 8946×2 9198×8 HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of Sep. 6, 2007. All specifications are subject to change without notice. 8835-01E11-79B-00P Printed in Japan