D2RW Sealed Reed Basic Switch Strongly Water-tight with a Unique Seal Construction D2RW internal structure Magnet Mechanical block Reed switch Internal reed switch construction enables to separate the conductor block and mechanical block. Conductor (Circuit) block Conductor block including the internal reed switch is entirely sealed with resin. Sealed resin Sealed Reed Basic Switch Achieving strong watertightness by sealing the internal switch and its conductor block The internal reed switch circuit block is separated from the mechanical actuator block, enabling the circuit block to be entirely sealed. Use of a reed switch maintains high contact reliability with micro load range. Compatible mounting dimension as miniature basic switch models V and D2VW. Ordering Information Model Number Legend D2RW-01 1 2 1. Ratings 01: 0.25A at 100 VDC 2. Actuator None: Pin plunger L1: Hinge lever L2: Hinge roller lever L3: Simulated roller lever List of Models 2 Actuator Pin plunger Hinge lever Model D2RW-01 D2RW-01L1 Hinge roller lever D2RW-01L2 Simulated roller lever D2RW-01L3 D2RW D2RW D2RW Specifications Ratings Switching voltage 100 VDC max. Switching current 0.25 A max. Contact capacity 10 W max. Note : The values apply under the following test conditions: Ambient temperature: 20±2°C Ambient humidity: 65±5% Operating frequency: 30 operations/min Characteristics Degree of protection Degree of protection against electric shock Proof tracking index (PTI) 0.1 mm to 1m/s (pin plunger models) Machanical : 150 operations/min max. Electrical : 30 operations/min max. 100 MΩ min. (at 100 VDC) between terminals of same polarity 100 MΩ min. (at 500 VDC) between current-carrying metal parts and ground 300 mΩ max. 200 VDC for 1 min between terminals of same polarity 500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Destruction: 500 m/s2 {approx. 50G} max. Malfunction: 200 m/s2 {approx. 20G} max. Mechanical: 1,000,000 operations min. (30 operations/min) Electrical: 1,000,000 operations min.(15 operations/min) (100 mA at 24 VDC) IEC IP67 (circuit block only) Class Ⅰ 175 Ambient operating temperature Ambient operating humidity Weight −10°C to 60°C (at ambient humidity of 60% max.) (with no icing or condensation) 95% max. (for 5°C to 35°C) Approx. 20 g (pin plunger models) Operating speed Operating frequency Insulation resistance Contact resistance (initial value) Dielectric strength (see note 2) Vibration resistance (see note 3) Shock resistance (see note 3) Durability (see note 4) Note : 1. The data given above are initial values. 2. The dielectric strength values shown in the table are for models with a separator. 3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models, they apply at the total travel position. Contact opening or closing time is within 1ms. 4. For testing conditions, contact your OMRON sales representative. Contact Specifications Internally mounted reed switch Minimum applicable load 100µA at 5 VDC Contact Form SPST-NO Reed switch NO (White) COM (Black) Dimensions Note : All units are in millimeters unless otherwise indicated. Terminals Mounting Holes Molded Lead Wires Two, 3.1-dia. mounting holes or M3 screw holes AWG20(White) UL1015 AWG20(Black) UL1015 (5) 3 D2RW D2RW Dimensions and Operating Characteristics Note: 1.All units are in millimeters unless otherwise indicated. 2.Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 3.The operating characteristics are for operation in the A direction ( ). Pin Plunger Models OF max. RF min. 1.5N {153gf} 0.1N {10gf} PT max. OT min. MD max. 1.6 mm 0.6 mm 0.8 mm OP 14.7±0.6 mm OF max. RF min. 0.75N {76gf} 0.05N {5gf} PT max. OT min. MD max. 4.0 mm 1.0 mm 1.6 mm OP 15.2±1.5 mm φ4.8×4.8 polyacetal resin roller OF max. RF min. 0.75N {76gf} 0.05N {5gf} t=0.5 stainless-steel lever +0.13 φ3.1-dia.Holes −0.03 PT max. OT min. MD max. 4.0 mm 1.0 mm 1.6 mm OP 20.7±1.5 mm OF max. RF min. 0.75N {76gf} 0.05N {5gf} PT max. OT min. MD max. 4.0 mm 1.0 mm 1.6 mm OP 18.7±1.5 mm D2RW-01 Hinge Lever Models D2RW-01L1 Hinge Roller Lever Models A D2RW-01L2 34±0.8 PT 8.15 2.8 OP 10.3±0.1 2.8 3.4±0.15 +0.13 2.8 3.1−0.03 Simulated Roller Lever Models D2RW-01L3 4 15.9 22.2±0.1 35.9 (5) 10.3 500±10 D2RW D2RW Precautions Cautions Correct Use Degree of Protection Mounting Do not use this product in water. Although this models satisfy the test conditions for the standard given below, this test is to check the ingress of water into the switch enclosure after submerging the Switch in water for a given time. Satisfying this test condition does not mean that the Switch can be used in water. IEC 60529: 2001 Degrees of protection provided by enclosures (IP Code) Code: IP67 (The test to meet the standard checks for water intrusion after immersion for 30 minutes.) Use M3 mounting screws with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.39 to 0.59 N•m {4 to 6 kgf•cm}. Mount the Switch onto a flat surface. Mounting on an uneven surface may cause deformation of the Switch, resulting in faulty operation or damage. Prevent the Switch to be exposed to water spray or to have water adhere to the Switch surface during sudden temperature changes, otherwise water may intrude into the interior of the Switch due to a suctin effect. Prevent the Switch from coming into contact with oil and chemicals. Otherwise, damage to or deterioration of Switch materials may result. The environment-resistant performance of the switch differs depending on operating loads, ambient atmospheres, and installation conditions, etc. Please perform an operating test of the switch in advance under actual usage conditions. Handling Do not drop the Switch, as the internal mechanism of the Switch may be damaged and, as a result, the characteristics of the Switch may be degraded. Effect of External vibrations Note that the application of 1 kHz or higher vibration to the Switch may cause switching failure due to resonance frequencies, even though the acceleration may be small. Handling When handling the Switch, ensure that uneven pressure or, as shown in the following diagram, pressure in a direction other than the operating direction is not applied to the Actuator, otherwise the Actuator or Switch may be damaged, or durabillty may be decreased. Operating Stroke Setting Install the Switch so that the operating body matches the movement direction of the actuator. Set the operating stroke so that the actuator is completely disengaged when the switch is in the free position (FP), and is pushed to a point between 60% and 90% of the OT distance after the switch is operated. Avoid shock operation to the Switch, as this may result in a degradation in the durability of the switch. Effect of External Magnetic Field Do not install two or more Switches in close proximity. Doing so may result in failure due to interference by leaked magnetic fields. When installing several switches, maintain a distance of at least 8mm between units. When mounting on a steel plate, maintain a distance of at least 2mm between Switches as failure to do so may lead to changes in operating characteristics. Avoid installing the Switch where there are strong magnetic forces, as these may cause failures in operation. Screws used to mount the Switch should be made of brass or stainless steel (SUS304). Avoid using steel screws. Storage Environment Make sure that the location is free of corrosive gas, dust with no high temperature or humidity, or rapid temperature change. It is recommended that a switch be inspected before use if it is stored for three months or more after the production, depending on the location. Effect of Contained Material The Switch uses a corrosion inhibitor inside the unit. Before using, check the effect of outgassing. 5 D2RW D2RW OMRON Switches for Integration in Machinery Miniature Basic Switches (V-size) D3V VX V D2MV K D2RV D2MC D2JW D2FW-G Subminiature Basic Switches (S-size) D3M SS SS-P SSG D2S Ultra Subminiature Switches (J-size) D2F J D2MQ Sealed Basic Switches D2RW D2VW D2SW D2SW-P D2HW Door Switches D3D D2D D2T Miniature Detection Switches D2A D3C D2X D3K ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. B110-E1-01 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Electronic Components Company Switch Division Detection Switch Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7096/Fax: (81)75-344-7188 URL: http://www.omron.com/ecb/ Printed in Japan 0904-2M (1203) (W)