Datasheet

D2VW
Sealed Miniature Basic Switch
Sealed Miniature Basic
Switch Conforms to IP67
(Excluding the terminals on
terminal models)
D
2
V
W
● Use of epoxy resin assures stable sealing, making
this switch ideal for places subject to water spray
or excessive dust.
● V-series internal mechanism assures high
precision and durability. The mounting is the
same as of the V models.
● Ideal for automobiles, agricultural machines,
large-scale home appliances, and industrial
equipment, which require high environmental
resistance.
RoHS Compliant
Model Number Legend
1
D2VW - @
1. Ratings
5 : 250 VAC 5 A
01 : 30 VDC 0.1 A
2. Actuator
None : Pin plunger
L1A : Short hinge lever
L1 : Hinge lever
L1B : Long hinge lever
L2A : Short hinge roller lever
L2 : Hinge roller lever
L3 : Simulated roller lever
2 @
3 @
4 @
5
@
4. Terminals
None, HS : Solder terminals
M, MS : Molded lead wires
Note: UL/CSA approved versions are available.
In this case, HS, MS will be added to the end of the model numbe
UL/CSA approved models have UL approved wiring
(AWG20 UL1015).
Consult your OMRON sales representative for details.
5. Length of the molded lead wire
None : 300 mm
-0 : 1,000 mm
3. Contact form
-1 : SPDT
-2 : SPST-NC
-3 : SPST-NO
1
D2VW
Sealed Miniature Basic Switch
List of Models
Ratings
Actuator
Terminals
Solder terminals
Pin plunger
Molded lead wires (1,000 mm)
Solder terminals
Short hinge lever
Molded lead wires (300 mm)
Molded lead wires (1,000 mm)
Solder terminals
Hinge lever
Molded lead wires (1,000 mm)
Solder terminals
Long hinge lever
Molded lead wires (300 mm)
Molded lead wires (1,000 mm)
Solder terminals
Short hinge roller lever
Molded lead wires (300 mm)
Molded lead wires (1,000 mm)
Solder terminals
Hinge roller lever
Molded lead wires (300 mm)
Molded lead wires (1,000 mm)
Solder terminals
Simulated roller lever
Molded lead wires (300 mm)
Molded lead wires (1,000 mm)
D2VW-5-1
D2VW-01-1
D2VW-5-2
D2VW-01-2
SPST-NO
D2VW-5-3
D2VW-01-3
D2VW-5-1M
D2VW-01-1M
SPST-NC
D2VW-5-2M
D2VW-01-2M
SPST-NO
D2VW-5-3M
D2VW-01-3M
SPDT
D2VW-5-1M-0
D2VW-01-1M-0
SPDT
D2VW-5L1A-1
D2VW-01L1A-1
SPST-NC
D2VW-5L1A-2
D2VW-01L1A-2
SPST-NO
D2VW-5L1A-3
D2VW-01L1A-3
D2VW-01L1A-1M
SPDT
D2VW-5L1A-1M
SPST-NC
D2VW-5L1A-2M
D2VW-01L1A-2M
SPST-NO
D2VW-5L1A-3M
D2VW-01L1A-3M
SPDT
D2VW-5L1A-1M-0
D2VW-01L1A-1M-0
SPDT
D2VW-5L1-1
D2VW-01L1-1
SPST-NC
D2VW-5L1-2
D2VW-01L1-2
SPST-NO
D2VW-5L1-3
D2VW-01L1-3
D2VW-5L1-1M
D2VW-01L1-1M
SPST-NC
D2VW-5L1-2M
D2VW-01L1-2M
SPST-NO
D2VW-5L1-3M
D2VW-01L1-3M
SPDT
D2VW-5L1-1M-0
D2VW-01L1-1M-0
SPDT
D2VW-5L1B-1
D2VW-01L1B-1
SPST-NC
D2VW-5L1B-2
D2VW-01L1B-2
SPST-NO
D2VW-5L1B-3
D2VW-01L1B-3
SPDT
D2VW-5L1B-1M
D2VW-01L1B-1M
SPST-NC
D2VW-5L1B-2M
D2VW-01L1B-2M
SPST-NO
D2VW-5L1B-3M
D2VW-01L1B-3M
SPDT
D2VW-5L1B-1M-0
D2VW-01L1B-1M-0
D2VW-01L2A-1
SPDT
D2VW-5L2A-1
SPST-NC
D2VW-5L2A-2
D2VW-01L2A-2
SPST-NO
D2VW-5L2A-3
D2VW-01L2A-3
D2VW-01L2A-1M
SPDT
D2VW-5L2A-1M
SPST-NC
D2VW-5L2A-2M
D2VW-01L2A-2M
SPST-NO
D2VW-5L2A-3M
D2VW-01L2A-3M
SPDT
D2VW-5L2A-1M-0
D2VW-01L2A-1M-0
SPDT
D2VW-5L2-1
D2VW-01L2-1
SPST-NC
D2VW-5L2-2
D2VW-01L2-2
SPST-NO
D2VW-5L2-3
D2VW-01L2-3
D2VW-01L2-1M
SPDT
D2VW-5L2-1M
SPST-NC
D2VW-5L2-2M
D2VW-01L2-2M
SPST-NO
D2VW-5L2-3M
D2VW-01L2-3M
SPDT
D2VW-5L2-1M-0
D2VW-01L2-1M-0
D2VW-01L3-1
SPDT
D2VW-5L3-1
SPST-NC
D2VW-5L3-2
D2VW-01L3-2
SPST-NO
D2VW-5L3-3
D2VW-01L3-3
D2VW-01L3-1M
SPDT
D2VW-5L3-1M
SPST-NC
D2VW-5L3-2M
D2VW-01L3-2M
SPST-NO
D2VW-5L3-3M
D2VW-01L3-3M
D2VW-5L3-1M-0
D2VW-01L3-1M-0
SPDT
Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately)
2
0.1 A
SPDT
SPDT
Molded lead wires (300 mm)
5A
SPST-NC
SPDT
Molded lead wires (300 mm)
D
2
V
W
Contact form
Refer to "Basic Switch Common Accessories"
D2VW
Sealed Miniature Basic Switch
●Safety Standard Approved Models
Ratings
Actuator
Terminals
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Hinge roller lever
Simulated roller lever
0.1A
Solder terminals
D2VW-5-1HS
D2VW-01-1HS
Molded lead wires (300 mm)
D2VW-5-1MS
D2VW-01-1MS
Solder terminals
D2VW-5L1A-1HS
D2VW-01L1A-1HS
Molded lead wires (300 mm)
D2VW-5L1A-1MS
D2VW-01L1A-1MS
Solder terminals
D2VW-5L1-1HS
D2VW-01L1-1HS
Molded lead wires (300 mm)
D2VW-5L1-1MS
D2VW-01L1-1MS
Solder terminals
D2VW-5L1B-1HS
D2VW-01L1B-1HS
Molded lead wires (300 mm)
Short hinge roller lever
5A
Contact form
SPDT
D2VW-5L1B-1MS
D2VW-01L1B-1MS
Solder terminals
D2VW-5L2A-1HS
D2VW-01L2A-1HS
Molded lead wires (300 mm)
D2VW-5L2A-1MS
D2VW-01L2A-1MS
Solder terminals
D2VW-5L2-1HS
D2VW-01L2-1HS
Molded lead wires (300 mm)
D2VW-5L2-1MS
D2VW-01L2-1MS
Solder terminals
D2VW-5L3-1HS
D2VW-01L3-1HS
Molded lead wires (300 mm)
D2VW-5L3-1MS
D2VW-01L3-1MS
D
2
V
W
Contact Form
●SPDT
●SPST-NC
NC (Red)
NO (Blue)
COM (Black)
●SPST-NO
NC (Red)
NO (Blue)
COM (Black)
COM (Black)
The color in parentheses indicates
the color of the lead wire.
Contact Specifications
Item
Model
D2VW-5 models
D2VW-01 models
Rivet
Crossbar
Silver alloy
Gold alloy
Specification
Contact
Material
Gap (standard value)
Inrush
current
15A max.
-
NO
15A max.
-
5 VDC 160 mA
5 VDC 1 mA
Please refer to "Using Micro Loads" in "●Precautions" for more
information on the minimum applicable load.
Item
D2VW-5 models
D2VW-01 models
UL (UL1054)/CSA (CSA C22.2 No.55)
D2VW-5
D2VW-01
125 VAC
250 VAC
3A
3A
0.1 A
-
30 VDC
-
0.1 A
Rated voltage
250 VAC
125 VAC
Resistive load
5A
5A
30 VDC
5A
125 VAC
0.1 A
30 VDC
0.1 A
Model
D2VW-5
D2VW-01
3A
0.1 A
-
VDE (EN61058-1)
Rated voltage
125 VAC
250 VAC
Ratings
Model
Consult your OMRON sales representative for specific models
with UL/CSA, VDE approvals.
Rated voltage
0.5 mm
NC
Minimum applicable load
(reference value) *
*
Approved Safety Standards
Model
Testing conditions: D2VW-5 25E3 (25,000 operations)
T55 (0 to 55°C)
D2VW-01 1E5 (100,000 operations)
T85 (0 to 85°C)
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately)
Refer to "Micro Switch Common Accessories"
3
D2VW
Sealed Miniature Basic Switch
Characteristics
Item
Mounting Holes (Unit: mm)
Model
D2VW-5 models
Permissible operating speed
Permissible
operating
frequency
Mechanical
Electrical
60 operations/min
Terminal models
50 mΩ max.
200 mΩ max.
Between terminals of the
same polarity
1,000 VAC 50/60 Hz for 1 min
Between current-carrying
metal parts and ground
1,500 VAC 50/60 Hz for 1 min
Between terminals and
non-current-carrying
metal parts
1,500 VAC 50/60 Hz for 1 min
10 to 55 Hz, 1.5 mm double amplitude
Destruction
1,000m/s2 {approx. 100G} max.
Malfunction *2
300m/s2 {approx. 30G} max.
Mechanical
Durability *3
Degree of
protection
22.2±0.1
100 mΩ max.
Vibration
Malfunction
resistance *2
Shock
resistance
10.3±0.1
100 MΩ min. (500 VDC with insulation tester)
Contact
Molded lead wire
resistance
terminals (300mm)
(initial value) Molded lead wire
terminals (1,000mm)
Dielectric
strength *1
Electrical
Terminal models
10,000,000 operations min. (60 operations/min)
100,000 operations min.
(30 operations/min)
IEC IP67
Degree of protection against electric
shock
Class l
Proof tracking index (PTI)
175
–40°C to +85°C (at ambient humidity of 60% max.)
(with no icing or condensation)
95% max. (for +5°C to +35°C)
Ambient operating humidity
Weight
1,000,000 operations min.
(30 operations/min)
IEC IP67 (excluding the terminals on terminal models)
Molded lead wire models
Ambient operating temperature
2-3.1 dia. mounting holes
or M3 screw holes
300 operations/min
Insulation resistance
D
2
V
W
D2VW-01 models
0.1mm to 1m/s (for pin plunger models)
Approx. 7 g (for pin plunger models with terminals)
Note. The data given above are initial values.
*1. The dielectric strength shown in the table indicates the value for models
with a Separator (refer to "Basic Switch Common Accessories").
*2. For the pin plunger models, the above values apply for use at the free
position and total travel position. For the lever models, they apply at the
total travel position. Close or open circuit of the contact is 1 ms max.
*3. For testing conditions, consult your OMRON sales representative.
Dimensions (Unit: mm) and Operating Characteristics
The illustrations and dimensions are for pin plunger models.
Dimensions and operation characteristics of other actuator models are the same as those of molded lead
wires models.
Models with solder terminals
●Pin Plunger Models
D2VW-5-1
D2VW-01-1
2.4 dia. holes 1.3 dia. holes
10.3
4.75
1.2
5.2
8.4
PT
2.8
OP
A
20.2±0.25
2.5 dia.
3.1+0.13
-0.03 dia. holes
0.5
2.5
5.2
15.9 10.3±0.1
5.2
3.1+0.13
-0.03
2.8
3.2±0.1 dia.
22.2±0.1
33
t0.5
3-Solder terminals
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
4
Operating Force
Releasing Force
OF
RF
Max.
Min.
1.96 N {200 gf}
0.29 N {30 gf}
Pretravel
Overtravel
Movement Differential
PT
OT
MD
Max.
Min.
Max.
1.2 mm
1.0 mm
0.4 mm
Operating Position
OP
14.7±0.4 mm
D2VW
Sealed Miniature Basic Switch
The illustration and drawing shown is the SPDT model. SPST-NC model and SPST-NO model are omitted.
Models with molded lead wires
●Pin Plunger Models
D2VW-5-1M
D2VW-5-1M-0
D2VW-01-1M
D2VW-01-1M-0
2.8
OP
AV0.75f molded lead wire (red)*
20.2±0.25
2.5 dia.
PT
A
AV0.75f molded lead wire (blue)*
AV0.75f molded lead wire (black)*
3.1+0.13
0.03 dia. holes
Operating Force
Releasing Force
15.9 10.3±0.1
3.1+0.13
-0.03
3.2±0.1 dia.
22.2±0.1
33
2.8
(5)
10.3
Operating Position
300 mm type 1,000 mm type
L
24.3±0.8
PT
OP
t=0.5*
A
300±10
5
35.6±0.8
A
t=0.5*
OP
* UL/CSA approved models have UL
approved wiring (AWG20 UL1015).
4.3
Operating Force
Releasing Force
5
4.3
A
59.4±0.8
t=0.5*
5
32.6±0.8
A
4.3
Operating Force
Releasing Force
OF Max. 1.18 N {120 gf}
RF Min. 0.15 N {15 gf}
OP
4.3
t=0.5*
Operating Force
Releasing Force
OF Max.
RF Min.
15.2±1.2 mm
0.59 N {60 gf}
0.05 N {5 gf}
9.0 mm
3.2 mm
2.0 mm
Operating Position
OP
15.2±2.6 mm
Operating Force
Releasing Force
OF Max.
RF Min.
1.18N {120 gf}
0.15N {15 gf}
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
OP
Operating Position
15.9
* Stainless-steel lever
4.0 mm
1.6 mm
0.8 mm
10.3
5
R3.5
15.2±0.5 mm
10.3
15.9
●Simulated Roller Lever Models
D2VW-5L3-1M
PT
D2VW-5L3-1M-0
D2VW-01L3-1M
D2VW-01L3-1M-0
1.6 mm
0.8 mm
0.5 mm
OP
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
* Stainless-steel lever
1.96 N {200 gf}
0.20 N {20 gf}
Operating Position
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
15.9
* Stainless-steel lever
OP
OF Max.
RF Min.
10.3
Operating Position
●Long Hinge Lever Models
D2VW-5L1B-1M
PT
D2VW-5L1B-1M-0
D2VW-01L1B-1M
D2VW-01L1B-1M-0
14.7±0.4 mm
1,000±30
15.9
PT
1.2 mm
1.0 mm
0.4 mm
OP
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
* Stainless-steel lever
●Hinge Lever Models
D2VW-5L1-1M
D2VW-5L1-1M-0
D2VW-01L1-1M
D2VW-01L1-1M-0
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
L
Dimensions
●Short Hinge Lever Models
D2VW-5L1A-1M
D2VW-5L1A-1M-0
D2VW-01L1A-1M
D2VW-01L1A-1M-0
OF Max. 1.96 N {200 gf}
RF Min. 0.29 N {30 gf}
OP
4.0 mm
1.6 mm
0.8 mm
18.7±1.2 mm
10.3
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
5
D
2
V
W
D2VW
Sealed Miniature Basic Switch
Models with molded lead wires
●Short Hinge Roller Lever Models
D2VW-5L2A-1M
D2VW-5L2A-1M-0
*2
4.8×4.8 dia.
D2VW-01L2A-1M
PT
D2VW-01L2A-1M-0
24.3±0.8
20.1±0.8
A
5
7.2
*1
t=0.5
15.9
*1. Stainless-steel lever
*2. Polyacetal resin roller
●Hinge roller lever
D2VW-5L2-1M
D2VW-5L2-1M-0
D2VW-01L2-1M
D2VW-01L2-1M-0
A
PT
34±0.8
4.8×4.8 * 2 dia.
Operating Position
OP
Operating Force
Releasing Force
OF Max.
RF Min.
5
7.2
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
t=0.5 * 1
Operating Position
15.9
*1. Stainless-steel lever
*2. Polyacetal resin roller
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
2.25 N {230 gf}
0.20 N {20 gf}
1.6 mm
0.8 mm
0.5 mm
20.7±0.6 mm
10.3
OP
6
OF Max.
RF Min.
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
OP
D
2
V
W
Operating Force
Releasing Force
10.3
OP
1.18 N {120 gf}
0.15 N {15 gf}
4.0 mm
1.6 mm
0.8 mm
20.7±1.2 mm
D2VW
Sealed Miniature Basic Switch
Precautions
★Please refer to "Basic Switches Common Precautions" for correct use.
Cautions
Correct Use
●Degree of Protection
●Mounting
Do not use the Switch underwater.
The Switch was tested and found to meet the conditions
necessary to meet the following standard, however, the test
checks for water intrusion after immersion for a specified time
period, not for switching operation underwater.
JIS C0920:
Degrees of protection provided by enclosures of electrical
apparatus (IP Code)
IEC 60529:
Degrees of protection provided by enclosures (IP Code)
Degree of protection: IP67
(check water intrusion after immersion
for 30 min submerged 1 m underwater)
Use M3 mounting screw with plane washers or spring washers to
securely mount the Switch. Tighten the screws to a torque of
0.39 to 0.59 N·m {4 to 6 kgf·cm}.
Prevent the Switch from coming into contact with oil or
chemicals.
Otherwise, damage to or deterioration of Switch materials may
result.
●Soldering
• Connecting to Solder Terminals
When soldering the lead wire to the terminal, first insert the
lead wire conductor through the terminal hole and then
conduct soldering.
Complete the soldering at the iron tip temperature between
350 to 400°C within 3 seconds, and do not apply any external
force for 1 minute after soldering. Soldering at a excessively
high temperature or soldering for more than 3 s may
deteriorate the characteristics of the Switch.
D
2
V
W
With the pin plunger models, set
the Switch so that the plunger can
be pushed in from directly above.
Since the plunger is covered with
a rubber cap, applying a force
from lateral directions may cause
damage to the plunger or
reduction in the sealing capability.
●Handling
Handle the Switch carefully so as not to break the sealing
rubber.
●Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the following operating range, if inrush
current occurs when the contact is opened or closed, it may
increase the contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary. The N-level
reference value applies for the minimum applicable load. This
value indicates the malfunction reference level for the reliability
level of 60% (λ60).
(JIS C5003)
The equation, λ60=0.5×10-6/operations indicates that the
1
estimated malfunction rate is less than 2,000,000 operations
with a reliability level of 60%.
Voltage (V)
●Protection Against Chemicals
●Operating Body
30
0.16 mA
26 mA 100 mA
24
Operating range for
micro load models
D2VW-01
Operating
range for
general-load
models
D2VW-5
12
5
1 mA
100mA 160 mA
0
0.1
1
10
100
1,000
Current (mA)
7
D2VW
Sealed Miniature Basic Switch
D
2
V
W
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
8
Contact: www.omron.com/ecb
Cat. No. C095-E1-05
0812(0207)(O)