FDFD7409-2

FDFD7409-2
Instantaneous Frequency Measurement
FEATURES
APPLICATIONS
• High Accuracy
• Electronic Counter Measurers
• High Resolution
• Signal Intelligence
• Low Power
• Radar Warning Receivers
• Short RF Pulse Capture
• Capture of Single RF Pulse Events
• Pipeline Processor
• Identification of Frequency Agile Radar
• High Data Rate
• Small Package Size
• Light Weight
• Erroneous Data Detection
(Optional)
S/N 004, Clean Signal
25 Deg. C, -10 dBm
Digital Word
16,000
14,000
12,000
10,000
8,000
6,000
4,000
2,000
0
2,000
4,000
6,000
8,000
10,000
12,000
14,000
16,000
18,000
Frequency (MHz)
Frequency Accuracy
VR = 100%, RMS = 1.14 MHz
15
Error (MHz)
10
5
0
-5
-10
-15
2,000
4,000
6,000
8,000
10,000
12,000
14,000
16,000
18,000
Frequency (MHz)
Rev 4.10.12
apitech.com • 888.553.7531 • spectrummicrowave.com
Instantaneous Frequency Measurement
FDFD7409-2
Specifications Highlights:
Frequency Range (GHz)
2 to 18 GHz
Number of Bits
14
RMS Frequency Accuracy
2 MHz at 6 dB SN
3 MHz at 0 dB SN (99% Valid Rate)
Frequency Resolution
1 MHz
Dynamic Range
-50 to +10 dBm OR -0 to +10 dBm
VSWR, max
2:1
Pulse Width
50 ns to CW
Data Format
TTL
Trigger Format
TTL, 20 MHz Pipeline
Erroneous Data Detection (optional)
85% Probability of Detection of Frequency Error
Power
+5V to +5.2V @ 800 mA
+12V to +15V @ 800 mA
-5V to -5.2V @ 100 mA OR -8V to -15V @ 100mA
(internally regulated)
Size
6.6” L x 5.5” W x 1.2” H
Weight
2.75 pounds maximum
RF Connector
SMA Female
Data Connector
51 socket - MDM51S (with jackposts)
Temperature Range
-40°C to +85°C
Rev 4.10.12
apitech.com • 888.553.7531 • spectrummicrowave.com