FDFD7409-2 Instantaneous Frequency Measurement FEATURES APPLICATIONS • High Accuracy • Electronic Counter Measurers • High Resolution • Signal Intelligence • Low Power • Radar Warning Receivers • Short RF Pulse Capture • Capture of Single RF Pulse Events • Pipeline Processor • Identification of Frequency Agile Radar • High Data Rate • Small Package Size • Light Weight • Erroneous Data Detection (Optional) S/N 004, Clean Signal 25 Deg. C, -10 dBm Digital Word 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 Frequency (MHz) Frequency Accuracy VR = 100%, RMS = 1.14 MHz 15 Error (MHz) 10 5 0 -5 -10 -15 2,000 4,000 6,000 8,000 10,000 12,000 Frequency (MHz) Rev 4.10.12 14,000 16,000 18,000 18,000 Instantaneous Frequency Measurement FDFD7409-2 Specifications Highlights: Rev 4.10.12 Frequency Range (GHz) 2 to 18 GHz Number of Bits 14 RMS Frequency Accuracy 2 MHz at 6 dB SN 3 MHz at 0 dB SN (99% Valid Rate) Frequency Resolution 1 MHz Dynamic Range -50 to +10 dBm OR -10 to +10 dBm VSWR, max 2:1 Pulse Width 50 ns to CW Data Format TTL Trigger Format TTL, 20 MHz Pipeline Erroneous Data Detection (optional) 85% Probability of Detection of Frequency Error Power +5V to +5.2V @ 800 mA +12V to +15V @ 800 mA -5V to -5.2V @ 100 mA OR -8V to -15V @ 100mA (internally regulated) Size 6.6” L x 5.5” W x 1.2” H Weight 2.75 pounds maximum RF Connector SMA Female Data Connector 51 socket - MDM51S (with jackposts) Temperature Range -40°C to +85°C