DR024-M4

TELEDYNE
DEFENCE LIMITED
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
A Teledyne Technologies Company
Features
12 Bit Resolution
External or Internal Trigger
50ns Pulse Capable
16GHz Instantaneous Bandwidth
-50dBm Sensitivity
Small Form Factor
Low Weight
Low Power Consumption
Applications
Electronic Support Measures (ESM)
Radar Warning Receivers (RWR)
ECM Set-on
Airborne, Fixed Wing & Rotary
Land
Naval
Product Description
The DR024-M4 utilises proprietary Teledyne Defence Limited (TDL) technology, to deliver state of the art performance
in a package measuring only 152mm x 147mm x 30mm and weighing only 1.55kg.
The DR024-M4 is can be externally or internally triggered and provides a digital 12-bit output word of the RF input
frequency with every sample. The internal analogue bandwidth is sufficient to capture a 50ns pulse.
With a resolution of 12 bits, the DR024-M4 gives a nominal frequency resolution of 3.93MHz and an rms accuracy of
≤4.5MHz with an input SNR of 3dB or better.
Designed specifically for fast jet applications, the DR024-M4 will withstand the most demanding of environments. It
is characterised for -40ºC to +85ºC. For applications outside this range, please contact the Sales Dept.
External connections are made via a 51 way high density D type for power and digital I/O and SMA for the RF input.
Other IFM configurations are available and for further information, please contact the TDL Sales Team.
Global Defence &
Security Solutions
DR024-M4 rev1.0
June 2010
Page 1 of 7
© Teledyne Defence Ltd, 2008. All rights reserved.
Teledyne Defence Ltd
Airedale House
Royal London Industrial Estate
Acorn Park, Charlestown
Shipley, West Yorkshire
UK, BD17 7SW
Tel: +44 (0) 1274 531 602
Fax:+44 (0) 1274 595 724
Email: [email protected]
Web: www.teledynedefence.co.uk
TELEDYNE
DEFENCE LIMITED
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
A Teledyne Technologies Company
Electrical Specification
Ref
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
1.
2.
3.
4.
5.
6.
7.
Parameter
Units
Min
Value
Nom
Max
Operating Frequency Range
GHz
1.955
18.045
Unambiguous Bandwidth
GHz
1.5
18.5
Frequency Resolution MHz
3.93
Digital Frequency Resolution
Bits
12
Throughput Time
ns
330
370
RF Input Dynamic Range
dBm
-50
10
RF Input Signal/Noise Ratio
dB
3
RF Input Pulse Width
ns
50
CW
RF Input VSWR
2.2:1
Frequency Error (RMS) at 0 dB SNR
MHz
5.6
Frequency Peak Error at 3 dB SNR
MHz
4.5
Simultaneous Signal: Level dBc
10
Simultaneous Signal: Frequency Separation
MHz
100
Overload Power
dBm
20
Temperature Range (operating)
°C
-40
85
Power Consumption
Watts
18.5
Power Supply Current: +15v Rail
mA
850
Power Supply Current: +5v Rail
mA
1000
Weight (Approx.)
kg
1.55
Notes
1
2
3
4
5
5
6
6
7
Nominal frequency resolution is unambiguous bandwidth divided by number of bits.
See timing diagrams.
Minimum SNR required for nominal operation.
Minimum pulse width is defined by internal video bandwidth.
The actual resolution, i.e.,the change of frequency required to change 1 bit of the output word varies with frequency. The rms accuracy is calculated as the standard deviation of the frequency distribution. The rms accuracy is specified for 3dB and 0dB input SNR. The rms error excludes those measurements that are flagged as “bad data”.
Simultaneous signals are defined as signals which overlap by at least 30ns during a measurement cycle. A valid measurement will be made on the larger of two signals provided that a) the amplitude difference between them is 10dB and b) there is at least 100MHz frequency separation.
Maximum input power without damage.
DR024-M4 rev1.0
June 2010
Page 2 of 7
TELEDYNE
DEFENCE LIMITED
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
A Teledyne Technologies Company
Timing Information
Operation with external trigger
Parameter
Description
Trfd
Tetrgw
Tst
Tdvld
Tdvldw
Tsu
Thld
Tshol
Delay from RF to External Trigger
External Trigger width
Delay from External Trigger to Strobe
Delay from External Trigger to data Valid
Data Valid width
Data set up time w.r.t. Data Valid
Data hold time w.r.t. Data Valid
Strobe hold time w.r.t. Data Valid
DR024-M4 rev1.0
June 2010
Page 3 of 7
Min
4 ns
50 ns
40 ns
330 ns
330 ns
20 ns
20 ns
0 ns
Timings
Max
12 ns
300 ns
370 ns
370 ns
TELEDYNE
DEFENCE LIMITED
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
A Teledyne Technologies Company
Pin Designations
Pin
Signal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
+15V
+15V
+15V
0V
Trigger Select
0V
External Trig
0V
Strobe
0V
Data Valid +
Data Valid -
0V
RF Present +
RF Present -
0V
Bad Data -
Bad Data +
0V
Not Used
Not Used
Not Used
Not Used
+5V
+5V
+5V
Freq 11+
Freq 11 -
Freq 10+
Freq 10 -
Freq 9+
Freq 9 -
Freq 8+
Freq 8 -
Freq 7+
Freq 7 -
Freq 6+
Freq 6 -
Freq 5 +
Freq 5 -
Freq 4+
Freq 4 -
Freq 3+
Freq 3 -
Freq 2+
Freq 2 -
Freq 1 +
Freq 1 -
Freq 0+
Freq 0 -
0V
DR024-M4 rev1.0
June 2010
Page 4 of 7
Direction
Power
Power
Power
Return
Input
Return
Input
Return
Input
Return
Output
Output
Return
Output
Output
Return
Output
Output
Return
Power
Power
Power
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Return
TELEDYNE
DEFENCE LIMITED
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
A Teledyne Technologies Company
Environmental Screening
100% of units subjected to: burn in 8 hours operational at 71ºC, random vibration (as below), 5min per axis, thermal shock (as
below), random vibration (as below), 5min per axis.
Environmental Data
Compliance can be shown by similarity to the following environmental conditions:
Sinusoidal Vibration: MIL-STD-202F, Method 204 - 5g profile between 5 and 104Hz for 90 min per axis
Random Vibration: MIL-STD-810D, Method 514.3 – specified profile (below) with max of 0.2g²/Hz for 60 min per axis, 20 to
2000Hz
Mechanical Shock: MIL-STD-202F, Method 213B – 15g/11ms, 3 shocks in each axis in each direction (18 total)
Acceleration: MIL-STD-202F, Method 212A, condition B, 6 to 14g
High Temperature storage: MIL-STD-810D, Method 501.2 - 95ºC for 8 hours
High Temperature operational: MIL-STD-820D, Method 501.2 – 71ºC / 30min, 60ºC / 60min, 55ºC / 4hr
Thermal Shock: 10 Cycles of –40ºC to 71ºC, 5 min ramp, 2hr dwell
Low Temperature storage: MIL-STD-810D, Method 502.2 - -54ºC for 8 hours.
Low temperature operational: MIL-STD-810D, Method 502.2 - -40ºC / 60min.
Combined temperature, altitude & humidity: MIL-STD-810D. Method 520 – temperature –40ºC to 70ºC, storage
condition sea level to 17000m (87.6mb), operating condition sea level to 11000m (228mb), relative humidity at sea
level 75%, 10 Cycles.
Humidity: MIL-STD-810D, Method 507.2, procedure 2 – RH 85% to 95%, temperature 30ºC to 60ºC, 24 hour cycle,
10 cycles.
EMI/EMC: Generally in accordance with MIL-STD-461E. Please note that system precautions must be taken to
prevent interfering signals entering the high gain RF front end.
DR024-M4 rev1.0
June 2010
Page 5 of 7
TELEDYNE
DEFENCE LIMITED
A Teledyne Technologies Company
Outline Drawing
DR024-M4 rev1.0
June 2010
Page 6 of 7
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
TELEDYNE
DEFENCE LIMITED
A Teledyne Technologies Company
Notes
DR024-M4 rev1.0
June 2010
Page 7 of 7
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
TELEDYNE
DEFENCE LIMITED
2 to 18Ghz Instantaneous
Frequency Measurement Unit
Technical Data DR024-M4
A Teledyne Technologies Company
Teledyne Defence Ltd
Airedale House
Royal London Industrial Estate
Acorn Park
Charlestown
Shipley, West Yorkshire
UK, BD17 7SW
Tel: +44 (0) 1274 531 602
Fax:+44 (0) 1274 595 724
Email: [email protected]
www.teledynedefence.co.uk
© Teledyne Defence Ltd, 2008. All rights reserved.