TELEDYNE DEFENCE LIMITED 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 A Teledyne Technologies Company Features 12 Bit Resolution External or Internal Trigger 50ns Pulse Capable 16GHz Instantaneous Bandwidth -50dBm Sensitivity Small Form Factor Low Weight Low Power Consumption Applications Electronic Support Measures (ESM) Radar Warning Receivers (RWR) ECM Set-on Airborne, Fixed Wing & Rotary Land Naval Product Description The DR024-M4 utilises proprietary Teledyne Defence Limited (TDL) technology, to deliver state of the art performance in a package measuring only 152mm x 147mm x 30mm and weighing only 1.55kg. The DR024-M4 is can be externally or internally triggered and provides a digital 12-bit output word of the RF input frequency with every sample. The internal analogue bandwidth is sufficient to capture a 50ns pulse. With a resolution of 12 bits, the DR024-M4 gives a nominal frequency resolution of 3.93MHz and an rms accuracy of ≤4.5MHz with an input SNR of 3dB or better. Designed specifically for fast jet applications, the DR024-M4 will withstand the most demanding of environments. It is characterised for -40ºC to +85ºC. For applications outside this range, please contact the Sales Dept. External connections are made via a 51 way high density D type for power and digital I/O and SMA for the RF input. Other IFM configurations are available and for further information, please contact the TDL Sales Team. Global Defence & Security Solutions DR024-M4 rev1.0 June 2010 Page 1 of 7 © Teledyne Defence Ltd, 2008. All rights reserved. Teledyne Defence Ltd Airedale House Royal London Industrial Estate Acorn Park, Charlestown Shipley, West Yorkshire UK, BD17 7SW Tel: +44 (0) 1274 531 602 Fax:+44 (0) 1274 595 724 Email: [email protected] Web: www.teledynedefence.co.uk TELEDYNE DEFENCE LIMITED 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 A Teledyne Technologies Company Electrical Specification Ref 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1. 2. 3. 4. 5. 6. 7. Parameter Units Min Value Nom Max Operating Frequency Range GHz 1.955 18.045 Unambiguous Bandwidth GHz 1.5 18.5 Frequency Resolution MHz 3.93 Digital Frequency Resolution Bits 12 Throughput Time ns 330 370 RF Input Dynamic Range dBm -50 10 RF Input Signal/Noise Ratio dB 3 RF Input Pulse Width ns 50 CW RF Input VSWR 2.2:1 Frequency Error (RMS) at 0 dB SNR MHz 5.6 Frequency Peak Error at 3 dB SNR MHz 4.5 Simultaneous Signal: Level dBc 10 Simultaneous Signal: Frequency Separation MHz 100 Overload Power dBm 20 Temperature Range (operating) °C -40 85 Power Consumption Watts 18.5 Power Supply Current: +15v Rail mA 850 Power Supply Current: +5v Rail mA 1000 Weight (Approx.) kg 1.55 Notes 1 2 3 4 5 5 6 6 7 Nominal frequency resolution is unambiguous bandwidth divided by number of bits. See timing diagrams. Minimum SNR required for nominal operation. Minimum pulse width is defined by internal video bandwidth. The actual resolution, i.e.,the change of frequency required to change 1 bit of the output word varies with frequency. The rms accuracy is calculated as the standard deviation of the frequency distribution. The rms accuracy is specified for 3dB and 0dB input SNR. The rms error excludes those measurements that are flagged as “bad data”. Simultaneous signals are defined as signals which overlap by at least 30ns during a measurement cycle. A valid measurement will be made on the larger of two signals provided that a) the amplitude difference between them is 10dB and b) there is at least 100MHz frequency separation. Maximum input power without damage. DR024-M4 rev1.0 June 2010 Page 2 of 7 TELEDYNE DEFENCE LIMITED 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 A Teledyne Technologies Company Timing Information Operation with external trigger Parameter Description Trfd Tetrgw Tst Tdvld Tdvldw Tsu Thld Tshol Delay from RF to External Trigger External Trigger width Delay from External Trigger to Strobe Delay from External Trigger to data Valid Data Valid width Data set up time w.r.t. Data Valid Data hold time w.r.t. Data Valid Strobe hold time w.r.t. Data Valid DR024-M4 rev1.0 June 2010 Page 3 of 7 Min 4 ns 50 ns 40 ns 330 ns 330 ns 20 ns 20 ns 0 ns Timings Max 12 ns 300 ns 370 ns 370 ns TELEDYNE DEFENCE LIMITED 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 A Teledyne Technologies Company Pin Designations Pin Signal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 +15V +15V +15V 0V Trigger Select 0V External Trig 0V Strobe 0V Data Valid + Data Valid - 0V RF Present + RF Present - 0V Bad Data - Bad Data + 0V Not Used Not Used Not Used Not Used +5V +5V +5V Freq 11+ Freq 11 - Freq 10+ Freq 10 - Freq 9+ Freq 9 - Freq 8+ Freq 8 - Freq 7+ Freq 7 - Freq 6+ Freq 6 - Freq 5 + Freq 5 - Freq 4+ Freq 4 - Freq 3+ Freq 3 - Freq 2+ Freq 2 - Freq 1 + Freq 1 - Freq 0+ Freq 0 - 0V DR024-M4 rev1.0 June 2010 Page 4 of 7 Direction Power Power Power Return Input Return Input Return Input Return Output Output Return Output Output Return Output Output Return Power Power Power Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Output Return TELEDYNE DEFENCE LIMITED 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 A Teledyne Technologies Company Environmental Screening 100% of units subjected to: burn in 8 hours operational at 71ºC, random vibration (as below), 5min per axis, thermal shock (as below), random vibration (as below), 5min per axis. Environmental Data Compliance can be shown by similarity to the following environmental conditions: Sinusoidal Vibration: MIL-STD-202F, Method 204 - 5g profile between 5 and 104Hz for 90 min per axis Random Vibration: MIL-STD-810D, Method 514.3 – specified profile (below) with max of 0.2g²/Hz for 60 min per axis, 20 to 2000Hz Mechanical Shock: MIL-STD-202F, Method 213B – 15g/11ms, 3 shocks in each axis in each direction (18 total) Acceleration: MIL-STD-202F, Method 212A, condition B, 6 to 14g High Temperature storage: MIL-STD-810D, Method 501.2 - 95ºC for 8 hours High Temperature operational: MIL-STD-820D, Method 501.2 – 71ºC / 30min, 60ºC / 60min, 55ºC / 4hr Thermal Shock: 10 Cycles of –40ºC to 71ºC, 5 min ramp, 2hr dwell Low Temperature storage: MIL-STD-810D, Method 502.2 - -54ºC for 8 hours. Low temperature operational: MIL-STD-810D, Method 502.2 - -40ºC / 60min. Combined temperature, altitude & humidity: MIL-STD-810D. Method 520 – temperature –40ºC to 70ºC, storage condition sea level to 17000m (87.6mb), operating condition sea level to 11000m (228mb), relative humidity at sea level 75%, 10 Cycles. Humidity: MIL-STD-810D, Method 507.2, procedure 2 – RH 85% to 95%, temperature 30ºC to 60ºC, 24 hour cycle, 10 cycles. EMI/EMC: Generally in accordance with MIL-STD-461E. Please note that system precautions must be taken to prevent interfering signals entering the high gain RF front end. DR024-M4 rev1.0 June 2010 Page 5 of 7 TELEDYNE DEFENCE LIMITED A Teledyne Technologies Company Outline Drawing DR024-M4 rev1.0 June 2010 Page 6 of 7 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 TELEDYNE DEFENCE LIMITED A Teledyne Technologies Company Notes DR024-M4 rev1.0 June 2010 Page 7 of 7 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 TELEDYNE DEFENCE LIMITED 2 to 18Ghz Instantaneous Frequency Measurement Unit Technical Data DR024-M4 A Teledyne Technologies Company Teledyne Defence Ltd Airedale House Royal London Industrial Estate Acorn Park Charlestown Shipley, West Yorkshire UK, BD17 7SW Tel: +44 (0) 1274 531 602 Fax:+44 (0) 1274 595 724 Email: [email protected] www.teledynedefence.co.uk © Teledyne Defence Ltd, 2008. All rights reserved.