ROHM BP5324A

BP5324A
Isolated DC/DC Converter
12V/250mA output type
Dimensions (Unit : mm)
Absolute Maximum Ratings
Unit
V
mA
°C
°C
Vrms
38.5Max.
13.6Max.
Mark Side
Limits
7
250
−25 to +80
−25 to +85
500
27.0Max.
Symbol
VIN
Iopeak
Topr
Tstg
VISO
4.0±1.0
Parameter
Input voltage
Maximum output current
Operating temperature range
Storage temperature range
Isolation voltage
1 2
4 5
3.25Max.
P=2.54±0.2
8
10 11 12
0.5±0.1
1.3±0.2
4.55Max.
0.25±0.05
9.05Max.
2.54×11=27.94
Electrical Characteristics
Typ.
5.0
12.0
−
0.01
0.23
0.03
74
Max.
5.5
12.6
250
0.05
0.5
0.15
−
Unit
V
V
mA
V
V
Vpp
%
Conditions
Derating Curve
VIN=5V, Io=250mA
∗1
VIN=5V
VIN=4.5 to 5.5V, Io=200mA
VIN=5V, Io=0 to 250mA ∗2
VIN=5V, Io=250mA
VIN=5V, Io=250mA
∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
Application circuit
BP5324A
BP5324A
F1
1 2
4 5
8
10 11 12
Vo
VIN
C1
C2
C3
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
Derating Curve
Function
Input terminal (5V)
Input terminal (5V)
Not used
Input terminal (0V)
Input terminal (0V)
Not used
Not used
Output GND terminal
Not used
Capacitor connect
Output terminal
Output terminal
300
250
200
150
Operation Range
100
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
Conversion Efficiency η(%)
Symbol Min.
4.5
VIN
Input voltage range
11.4
Vo
Output voltage
0
Io
Output current
−
VL
Line regulation
−
VR
Load regulation
−
Vp
Output ripple voltage
65
η
Power conversion efficiency
Output Current Io(mA)
Parameter
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vin=5V)
0.05 0.1 0.15 0.2 0.25 0.3 0.35
Output Current Io(A)
C4
Use a fuse for safety.
Be sure to evaluate it under the condition that it is mounted by your product.
Especially, confirm whether output current never exceeds a maximum rating
with current probe.
External Components Settings
F1 : Fuse
Use a 2.5A fuse
C1: Input Capacitor
Capacitance : 100µF to 220µF Rated voltage : 16V or higher .
C2: Output Capacitor
Capacitance : 100µF, Rated voltage : 25V or higher.
C3: Output Capacitor
Capacitance : 100µF to 470µ, Rated Voltage : 25V or higher.
C4: Noise Reduction Capacitor
Capacitance : 4700pF to 0.1µF, Rated Voltage : AC500V or higher.
Rev.A
Appendix
Notes
No technical content pages of this document may be reproduced in any form or transmitted by any
means without prior permission of ROHM CO.,LTD.
The contents described herein are subject to change without notice. The specifications for the
product described in this document are for reference only. Upon actual use, therefore, please request
that specifications to be separately delivered.
Application circuit diagrams and circuit constants contained herein are shown as examples of standard
use and operation. Please pay careful attention to the peripheral conditions when designing circuits
and deciding upon circuit constants in the set.
Any data, including, but not limited to application circuit diagrams information, described herein
are intended only as illustrations of such devices and not as the specifications for such devices. ROHM
CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any
third party's intellectual property rights or other proprietary rights, and further, assumes no liability of
whatsoever nature in the event of any such infringement, or arising from or connected with or related
to the use of such devices.
Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or
otherwise dispose of the same, no express or implied right or license to practice or commercially
exploit any intellectual property rights or other proprietary rights owned or controlled by
ROHM CO., LTD. is granted to any such buyer.
Products listed in this document are no antiradiation design.
The products listed in this document are designed to be used with ordinary electronic equipment or devices
(such as audio visual equipment, office-automation equipment, communications devices, electrical
appliances and electronic toys).
Should you intend to use these products with equipment or devices which require an extremely high level of
reliability and the malfunction of with would directly endanger human life (such as medical instruments,
transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other
safety devices), please be sure to consult with our sales representative in advance.
About Export Control Order in Japan
Products described herein are the objects of controlled goods in Annex 1 (Item 16) of Export Trade Control
Order in Japan.
In case of export from Japan, please confirm if it applies to "objective" criteria or an "informed" (by MITI clause)
on the basis of "catch all controls for Non-Proliferation of Weapons of Mass Destruction.
Appendix1-Rev1.1