ROHM BP5075-5

BP5075-5
AC/DC converter
AC100V input, −5V/120mA output
Dimensions (Unit : mm)
Absolute Maximum Ratings
Unit
Vin
Topr
Tstg
Tsmax
Iopeak
−170
−20 to +80
−25 to +105
105
120
V
°C
°C
°C
mApk
10.7MAX.
20.5MAX.
Mark Side
Limits
19.5MAX.
Symbol
4.0±1.0
Parameter
Input voltage
Operating temperature range
Storage temperature range
Maximum surface temperature
Maximum output current
1
4 5 6 7
0.5±0.1
3.25MAX.
P=2.54±0.2
1.3±0.2
0.25±0.05
6.25MAX.
4.45MAX.
2.54x6=15.24TYP.
Electrical Characteristics
Conditions
DC
Vin=−141V, Io=60mA
Unit
V
V
mA
V
V
Vp-p
%
Derating Curve
∗1
Vin=−113 to −170V, Io=60mA
Vin=−141V, Io=0 to 60mA
Vin=−141V, Io=60mA ∗2
Vin=−141V, Io=120mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 An output ripple voltage sometimes change in capacitor to use, the measurement environment.
BP5075-5
Be sure to use fuse for safety.
1
D1
R1
4
5
6
Functions
Input terminal
Not used
Not used
COMMON
COMMON
NC
Output terminal
Vin
+
−
C1
C3
C2
80
Operation Range
60
40
20
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature Ta(°C)
40
35
30
25
20
15
10
5
0
0
+
−
V
−
Vo
For actual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
100
90
80
70
60
50
40
30
20
10
0
0
External components setting
Capacitance : 3.3µF to 33µF
Rated voltage : 250V or higher
C2: Capacitor for Output
voltage smoothing
20
40
60
80 100
Output Current Io(mA)
120
Capacitance : 47µF to 470µF
Rated voltage : 16V or higher, Low impedance part
Impedance is 0.42Ω max at High frequency range.
Ripple current is 0.2Arms above.
Impedance of capacitor affects the output ripple voltage.
C3: For noise terminal
voltage reduction
Capacitance : 0.1µF to 0.22µF Rated voltage : 250V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
D1: Rectifier diode
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 1A or higher,
and the forward surge current should be 40A or higher.
R1: For noise terminal
voltage reduction
10Ω to 22Ω 1/4W
Reduce the noise terminal voltage.
The constant value should be evaluated in set.
ZNR: Varistor
Varistor must be used. It protects this part from lightning surge and static
electricity.
Conversion Efficiency
(Ta=25°C, Vi= −141V)
20
40
60
80 100
Output Current Io(mA)
120
Load Regulation
Load Regulation
(Ta=25°C, Vi= −141V)
-6.0
Output Voltage Vo(V)
Please make sure to use fuse 1.0A
C1: Capacitor for input
voltage smoothing
-5.0
-4.0
-3.0
Maximum
Io=120mA
-2.0
-1.0
0.0
0
20
40 60 80 100 120 140 160
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Increase ∆T(°C)
FUSE: Fuse
Switching Frequency
(Ta=25°C, Vi= −141V)
Conversion Efficiency
A
ZNR
100
7
FUSE
−
120
Switching frequency
Application circuit
Pin No.
1
2
3
4
5
6
7
Derating Curve
140
Output Current Io(mA)
Max.
−170
−5.3
120
0.20
0.20
0.20
−
Switching Frequency fsw(kHz)
Typ.
−141
−5.0
−
0.02
0.03
0.04
59
Conversion Efficiency η(%)
Symbol Min.
Parameter
Input voltage
−113
Vin
Output voltage
−4.7
Vo
Output current
−
Io
Line regulation
−
Vr
Load regulation
−
Vl
Output ripple voltage
−
Vp
Power conversion efficiency
55
η
Surface Temperature Increase
(Ta=25°C, Vi= −141V)
40
35
30
25
20
15
10
5
0
0
20
40
60
80 100
Output Current Io(mA)
120
Appendix
Notes
No technical content pages of this document may be reproduced in any form or transmitted by any
means without prior permission of ROHM CO.,LTD.
The contents described herein are subject to change without notice. The specifications for the
product described in this document are for reference only. Upon actual use, therefore, please request
that specifications to be separately delivered.
Application circuit diagrams and circuit constants contained herein are shown as examples of standard
use and operation. Please pay careful attention to the peripheral conditions when designing circuits
and deciding upon circuit constants in the set.
Any data, including, but not limited to application circuit diagrams information, described herein
are intended only as illustrations of such devices and not as the specifications for such devices. ROHM
CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any
third party's intellectual property rights or other proprietary rights, and further, assumes no liability of
whatsoever nature in the event of any such infringement, or arising from or connected with or related
to the use of such devices.
Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or
otherwise dispose of the same, no express or implied right or license to practice or commercially
exploit any intellectual property rights or other proprietary rights owned or controlled by
ROHM CO., LTD. is granted to any such buyer.
Products listed in this document are no antiradiation design.
The products listed in this document are designed to be used with ordinary electronic equipment or devices
(such as audio visual equipment, office-automation equipment, communications devices, electrical
appliances and electronic toys).
Should you intend to use these products with equipment or devices which require an extremely high level
of reliability and the malfunction of which would directly endanger human life (such as medical
instruments, transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers
and other safety devices), please be sure to consult with our sales representative in advance.
It is our top priority to supply products with the utmost quality and reliability. However, there is always a chance
of failure due to unexpected factors. Therefore, please take into account the derating characteristics and allow
for sufficient safety features, such as extra margin, anti-flammability, and fail-safe measures when designing in
order to prevent possible accidents that may result in bodily harm or fire caused by component failure. ROHM
cannot be held responsible for any damages arising from the use of the products under conditions out of the
range of the specifications or due to non-compliance with the NOTES specified in this catalog.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact your nearest sales office.
ROHM Customer Support System
www.rohm.com
Copyright © 2007 ROHM CO.,LTD.
THE AMERICAS / EUPOPE / ASIA / JAPAN
Contact us : webmaster@ rohm.co. jp
21, Saiin Mizosaki-cho, Ukyo-ku, Kyoto 615-8585, Japan
TEL : +81-75-311-2121
FAX : +81-75-315-0172
Appendix1-Rev2.0