FERROXCUBE DATA SHEET 3E10 Material specification 2013 July 05 Ferroxcube Material specification 3E10 3E10 SPECIFICATIONS A high permeability material optimized for use in wideband transformers as well as EMI-suppression filters. SYMBOL CONDITIONS VALUE 25 °C; ≤10 kHz; 0.25 mT 10 000 ± 20% B 25 °C; 10 kHz; 1200 A/m ≈ 460 100 °C; 10 kHz; 1200 A/m ≈ 270 25 °C; 30 kHz; 0.25 mT ≤ 5 × 10−6 25 °C; 100 kHz; 0.25 mT ≤ 20 × 10−6 ηB 25 °C; 10 kHz; 1.5 to 3 mT ≤ 0.5 × 10−3 T−1 ρ DC; 25 °C 3E10 µ's , µ''s UNIT µi tanδ/µ i 10 5 handbook, halfpage 10 4 µ's mT µ''s 10 3 2 ≈ 0.5 Ωm TC ≥ 130 °C density ≈ 5000 kg/m3 10 10 2 10 Fig.1 1 25oC 100oC handbook, halfpage B (mT) 3E10 µi f (MHz) 10 Complex permeability as a function of frequency. 500 20000 handbook, halfpage 1 3E10 400 15000 300 10000 200 5000 100 0 0 50 50 Fig.2 2013 July 05 150 T ( o C) 25 250 0 25 50 250 150 H (A/m) Initial permeability as a function of temperature. Fig.3 Typical B-H loops. 2 Ferroxcube Material specification 3E10 500 3E10 tan δ/ µ -6 10 4 handbook, halfpage ( 10 ) 400 3E10 µ rev 10 3 300 200 10 2 100 10 1 10 10 2 3 H (A/m) 10 0 0 100 200 300 400 500 f (kHz) Fig.4 Reversible permeability as a function of magnetic field strength. 30 handbook, halfpage Fig.5 3E10 Z (Ω) 20 10 0 10 102 103 f (kHz) 104 Fig.6 Impedance as a function of frequency measured on toroid T25/15/10 2013 July 05 3 Loss factor in function of frequency. Ferroxcube Material specification 3E10 DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS PRODUCT STATUS DEFINITIONS Preliminary specification Development This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS INDICATION DEFINITION Prototype These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. Design-in These products are recommended for new designs. Preferred These products are recommended for use in current designs and are available via our sales channels. Support These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability. 2013 July 05 4