FERROXCUBE 3B7

FERROXCUBE
DATA SHEET
3B7
Material specification
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
Material specification
3B7
3B7 SPECIFICATIONS
A low frequency filter material optimized for
frequencies up to 0.1 MHz.
SYMBOL
µi
B
tanδ/µi
CONDITIONS
VALUE
25 °C; ≤10 kHz;
0.25 mT
25 °C; 10 kHz;
1200 A/m
2300 ±20%
100 °C; 10 kHz;
1200 A/m
25 °C; 100 kHz;
0.25 mT
25 °C; 500 kHz;
0.25 mT
≈ 320
UNIT
≈ 440
3B7
µ's , µ''s
10 3
µ's
mT
µ''s
10 2
≤ 5 × 10−6
≈ 25 × 10−6
25 °C; 1 MHz; 0.25 mT
≈ 120 × 10−6
DF
25 °C; 10 kHz; 0.25 mT
≤ 4.5 × 10−6
αF
+20 to 70 °C; ≤10 kHz;
0.25 mT
DC, 25 °C
(0 ±0.6)
× 10−6
≈1
≥ 170
≈ 4 800
ρ
TC
density
MBW057
10 4
handbook, halfpage
10
10 1
1
10
f (MHz)
10 2
K−1
Ωm
°C
kg/m3
Fig.1
Complex permeability as
a function of frequency.
MBW058
5000
handbook, halfpage
3B7
µi
MBW020
500
25oC
100oC
handbook, halfpage
4000
B
(mT)
3B7
400
3000
300
2000
200
1000
100
0
50
50
150
T ( o C)
250
0
25
0
25
50
150
250
H (A/m)
Fig.2
2008 Sep 01
Initial permeability as a
function of temperature.
Fig.3 Typical B-H loops.
85
Ferroxcube
Material specification
3B7
MBW077
4000
handbook, halfpage
f = 10 kHz
o
T=25 C
µp
3B7
3000
2000
0.2 µs
2 µs
1000
0.1 µs
1 µs
0.5 µs
0
0
100
200
300
400
B (mT)
Fig.4 Pulse characteristics (unipolar pulses).
2008 Sep 01
86
Ferroxcube
Material specification
3B7
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
87