FERROXCUBE 3S1

FERROXCUBE
DATA SHEET
3S1
Material specification
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
Material specification
3S1
3S1 SPECIFICATIONS
A low frequency EMI-suppression material specified on
impedance and optimized for frequencies up to
30 MHz.
SYMBOL
µi
B
Z(1)
ρ
TC
density
CONDITIONS
25 °C; ≤10 kHz;
0.25 mT
25 °C; 10 kHz;
1200 A/m
100 °C; 10 kHz;
1200 A/m
25 °C; 1 MHz
25 °C; 10 MHz
DC; 25 °C
VALUE
MBW268
10 5
handbook, halfpage
3S1
µ's , µ''s
UNIT
≈ 4 000
10 4
≈ 400
µ's
mT
≈ 230
µ''s
10 3
≥ 30
≥ 60
≈1
≥ 125
≈ 4 900
Ω
Ωm
°C
kg/m3
2
10
10 2
10 1
1
f (MHz)
10
Note
1. Measured on a bead ∅5 × ∅2 × 10 mm.
Fig.1
MBW270
MBW269
20000
handbook, halfpage
500
25 oC
100 oC
handbook, halfpage
3S1
µi
Complex permeability as
a function of frequency.
B
(mT)
3S1
400
15000
300
10000
200
5000
100
0
50
0
50
Fig.2
2008 Sep 01
150
T ( o C)
250
25
0
25
50
150
250
H (A/m)
Initial permeability as a
function of temperature.
Fig.3 Typical B-H loops.
204
Ferroxcube
Material specification
3S1
MBW218
150
handbook, halfpage
3S1
Z
(Ω)
100
50
0
1
10
102
f (MHz)
103
Fig.3 Impedance as a function of frequency,
measured on a bead ∅5 × ∅2 × 10 mm.
2008 Sep 01
205
Ferroxcube
Material specification
3S1
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
206