CEN-60 series - Total Power International

CEN-60
60W Single Output LED Power Supply
Authorized Distributor: Total Power International, Inc.
Toll Free# 877-646-0900 (US)
½ Features :
PH# (978) 453-7272
series
www.total-power.com
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet location or outdoor application
3 years warranty
F
110
M
M
SELV
SPECIFICATION
MODEL
CEN-60-12
CEN-60-15
CEN-60-20
CEN-60-24
CEN-60-30
CEN-60-36
CEN-60-42
CEN-60-48
CEN-60-54
12V
15V
20V
24V
30V
36V
42V
48V
11.25 ~ 15V
15 ~ 20V
18 ~ 24V
22.5 ~ 30V
27 ~ 36V
31.5 ~ 42V
36 ~ 48V
54V
40.5 ~ 54V
4A
0 ~ 4A
3A
0 ~ 3A
2.5A
0 ~ 2.5A
2A
0 ~ 2A
1.7A
0 ~ 1.7A
1.45A
0 ~ 1.45A
1.3A
0 ~ 1.3A
1.15A
0 ~ 1.15A
60W
60W
60W
60W
61.2W
60.9W
62.4W
62.1W
2.4Vp-p
1.8Vp-p
2.4Vp-p
3Vp-p
3.6Vp-p
4Vp-p
4.6Vp-p
5Vp-p
VOLTAGE ADJ. RANGE (SVR1) 10.8 ~ 13.5V 13.5 ~ 17V
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
37 ~ 46V
43 ~ 53V
49 ~ 58V
CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A
VOLTAGE TOLERANCE Note.3 10%
2.3 ~ 3A
1.9 ~ 2.5A
1.5 ~ 2A
1.3 ~ 1.7A
1.1 ~ 1.45A
1 ~ 1.3A
0.9 ~ 1.15A
91%
91%
54 ~ 60V
59 ~ 65V
DC VOLTAGE
CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V
RATED CURRENT
CURRENT RANGE
5A
0 ~ 5A
RATED POWER
60W
RIPPLE & NOISE (max.) Note.2 2Vp-p
OUTPUT
LINE REGULATION
3.0%
LOAD REGULATION
5.0%
SETUP TIME
VOLTAGE RANGE
INPUT
3 ~ 4A
1400ms / 230VAC 2800ms / 115VAC at full load
Note.4 90 ~ 295VAC
127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF
EFFICIENCY(Typ.)
86%
AC CURRENT
INRUSH CURRENT(max.)
0.8A/115VAC
45A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
IP66
OVER VOLTAGE
OVER TEMPERATURE
0.9 at 75 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC
87%
88%
PF>0.95 / 230VAC at full load
90%
90%
90%
0.4A/230VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
14.5 ~ 17V 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 52V
Protection type : Shut down o/p voltage, re-power on to recover
85
10
(TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
89%
(Refer to output load derating curve)
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
TUV EN61347-1, EN61347-2-13, IP66 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
SAFETY &
EMI CONDUCTION & RADIATION Compliance to EN55015
EMC
Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A
523.4Khrs min. MIL-HDBK-217F (25
183*62.5*40.5mm (L*W*H)
0.56Kg;24pcs/14.4Kg/1.11CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Direct connecting to LEDs is not suggested for models with “RIPPLE & NOISE” > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
CEN-60
60W Single Output LED Power Supply
Mechanical Specification
Case No.993B
series
Unit:mm
183
10.5
7.28
162
7.08
7.6
300 20
300 20
Vo Io
ADJ. ADJ.
62.5
30.64
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
18AWG 3C SJTW
18AWG 2C SVT
7.08
7.28
30.64
+V(Red)
-V(Black)
40.5
4.2 4PL
Block Diagram
fosc : 50KHz(115VAC)
75KHz(230VAC)
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
+V
-V
DETECTION
CIRCUIT
O.L.P.
PWM & PFC
CONTROL
O.C.P.
O.V.P.
Derating Curve
Static Characteristics
Ta:25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
AMBIENT TEMPERATURE (
50
60
70
(HORIZONTAL)
60
50
40
90
100
125
)
Authorized Distributor: Total Power International, Inc.
135
145
155 165
175
180
200
230
295
INPUT VOLTAGE (V) 60Hz
Toll Free# 877-646-0900 (US)
PH# (978) 453-7272
www.total-power.com
CEN-60
60W Single Output LED Power Supply
series
Power Factor Characteristic
Power factor will be higher than 0.9 when output loading is 75% or higher.
PF
Constant Current Mode
1
0.98
0.96
0.94
0.92
0.9
0.88
0.86
0.84
0.82
0.8
0.78
230VAC
110VAC
50%
60%
70%
80%
90%
100%
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
CEN-60 series possess superior working efficiency that up to 91% can be reached in field applications.
94
92
90
88
86
84
82
80
78
76
74
72
70
68
66
64
62
60
230VAC
110VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
Vo(%)
100
(A) Constant
Voltage area
50
(max.)
(C)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve
Authorized Distributor: Total Power International, Inc.
Toll Free# 877-646-0900 (US)
PH# (978) 453-7272
www.total-power.com