Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com R P T- 6 0 60W Triple Output Medical Type series Features : 4"x2" miniature size Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT RPT-60A CH1 5V CH2 CH3 12V RATED CURRENT 4A CURRENT RANGE 0.5 ~ 4.4A RATED POWER 46.5W RPT-60C CH2 CH3 12V -12V CH1 5V CH2 -5V CH1 5V 15V -15V 2A 0.5A 4A 2A 0.5A 4A 1.5A 0.5A 0.1 ~ 2.2A 0.1 ~ 0.55A 0.5 ~ 4.4A 0.1 ~ 2.2A 0.1 ~ 0.55A 0.5 ~ 4.4A 0.1 ~ 1.65A 0.1 ~ 0.55A 100mVp-p 150mVp-p 50W PEAK LOAD(10sec.) Note.4 51.15W RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% LINE REGULATION INPUT RPT-60B OUTPUT NUMBER DC VOLTAGE 50W 55W 80mVp-p 80mVp-p 80mVp-p 6.0% +9,-8% 1.0% 1.0% 0.5% CH3 55W 80mVp-p 100mVp-p 80mVp-p +3,-2% 6.0% +6,-10% +3,-2% 6.0% 8.0% 0.5% 1.0% 2.0% 0.5% 2.0% 2.0% +5,-7% 2.0% 1.5% 200ms, 15ms/115VAC at full load 5.0% 1.5% 3.0% 4.0% LOAD REGULATION SETUP, RISE TIME 1.5% 2.0% 200ms, 15ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 77% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC COLD START 60A/230VAC LEAKAGE CURRENT For earth <200uA/264VAC, For patient <100uA/264VAC 15ms/115VAC at full load 127 ~ 370VDC 78% 79% 0.7A/230VAC 30A/115VAC 115 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 5) DIMENSION PACKING NOTE Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF OTHERS Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A 677.8Khrs min. MIL-HDBK-217F (25 ) 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com R P T- 6 0 60W Triple Output Medical Type series Features : 4"x2" miniature size Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT INPUT RPT-60D CH1 5V CH2 CH3 12V CH1 3.3V CH2 24V 5V 12V RATED CURRENT 3.5A 1A 0.5A 5A 3A 0.7A CURRENT RANGE 0.5 ~ 3.85A 0.1 ~ 1.1A 0.1 ~ 0.55A 0.5 ~ 5.5A 0.3 ~ 3.3A 0.1 ~ 0.77A RATED POWER 47.5W 8.0% 2.0% 2.0% 0.5% 3.0% 4.0% 200ms, 15ms/230VAC 200ms, 15ms/115VAC at full load HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 79% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC COLD START 60A/230VAC LEAKAGE CURRENT For earth <200uA/264VAC, For patient <100uA/264VAC WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE 80mVp-p 80mVp-p +3,-2% 80mVp-p 8.0% +6,-10% 0.5% 1.0% 2.0% 1.5% 2.0% +5.5,-5% 15ms/115VAC at full load 127 ~ 370VDC 75% 0.7A/230VAC 30A/115VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V CH1: 3.8 ~ 4.45V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A EMS IMMUNITY MTBF 677.8Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING NOTE 6.0% 1.5% WORKING TEMP. OTHERS 80mVp-p LOAD REGULATION SETUP, RISE TIME OVER VOLTAGE (Note 5) 43.9W 150mVp-p LINE REGULATION PROTECTION CH3 39.9W PEAK LOAD(10sec.) Note.4 52.25W RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% OVERLOAD EMC RPT-6003 OUTPUT NUMBER DC VOLTAGE 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com R P T- 6 0 60W Triple Output Medical Type Mechanical Specification series Unit:mm 101.6 3.175 44.45 50.8 3.175 95.25 3 2 1 CN1 1 2 3 4 5 6 CN2 3 max. 29 4- 3.3 DC Output Connector (CN2) : JST B6P-VH or equivalent AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1,2 3,4 5 6 Assignment V1 COM V2 V3 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. fosc : 100KHz RECTIFIERS & FILTER CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 ) 60 65 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 INPUT VOLTAGE (VAC) 60Hz 240 264