RPT-60 series - Total Power International

Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
R P T- 6 0
60W Triple Output Medical Type
series
Features :
4"x2" miniature size
Universal AC input / Full range
Low leakage current<200uA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
UL60950-1/IEC60950-1/EN60950-1 ITE safety approved
Fixed switch frequency at 100KHz
3 years warranty
EN60601-1
IEC60601-1
SPECIFICATION
MODEL
OUTPUT
RPT-60A
CH1
5V
CH2
CH3
12V
RATED CURRENT
4A
CURRENT RANGE
0.5 ~ 4.4A
RATED POWER
46.5W
RPT-60C
CH2
CH3
12V
-12V
CH1
5V
CH2
-5V
CH1
5V
15V
-15V
2A
0.5A
4A
2A
0.5A
4A
1.5A
0.5A
0.1 ~ 2.2A
0.1 ~ 0.55A
0.5 ~ 4.4A
0.1 ~ 2.2A
0.1 ~ 0.55A
0.5 ~ 4.4A
0.1 ~ 1.65A
0.1 ~ 0.55A
100mVp-p
150mVp-p
50W
PEAK LOAD(10sec.) Note.4 51.15W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 +3,-2%
LINE REGULATION
INPUT
RPT-60B
OUTPUT NUMBER
DC VOLTAGE
50W
55W
80mVp-p
80mVp-p
80mVp-p
6.0%
+9,-8%
1.0%
1.0%
0.5%
CH3
55W
80mVp-p
100mVp-p
80mVp-p
+3,-2%
6.0%
+6,-10%
+3,-2%
6.0%
8.0%
0.5%
1.0%
2.0%
0.5%
2.0%
2.0%
+5,-7%
2.0%
1.5%
200ms, 15ms/115VAC at full load
5.0%
1.5%
3.0%
4.0%
LOAD REGULATION
SETUP, RISE TIME
1.5%
2.0%
200ms, 15ms/230VAC
HOLD UP TIME (Typ.)
70ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
77%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.1A/115VAC
COLD START 60A/230VAC
LEAKAGE CURRENT
For earth <200uA/264VAC, For patient <100uA/264VAC
15ms/115VAC at full load
127 ~ 370VDC
78%
79%
0.7A/230VAC
30A/115VAC
115 ~ 150% rated output power
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
(Note 5)
DIMENSION
PACKING
NOTE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +65
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
I/P-FG:1.5KVAC
O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
OTHERS
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
677.8Khrs min.
MIL-HDBK-217F (25
)
101.6*50.8*29mm (L*W*H)
0.15Kg; 96pcs/15.4Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
R P T- 6 0
60W Triple Output Medical Type
series
Features :
4"x2" miniature size
Universal AC input / Full range
Low leakage current<200uA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
UL60950-1/IEC60950-1/EN60950-1 ITE safety approved
Fixed switch frequency at 100KHz
3 years warranty
EN60601-1
IEC60601-1
SPECIFICATION
MODEL
OUTPUT
INPUT
RPT-60D
CH1
5V
CH2
CH3
12V
CH1
3.3V
CH2
24V
5V
12V
RATED CURRENT
3.5A
1A
0.5A
5A
3A
0.7A
CURRENT RANGE
0.5 ~ 3.85A
0.1 ~ 1.1A
0.1 ~ 0.55A
0.5 ~ 5.5A
0.3 ~ 3.3A
0.1 ~ 0.77A
RATED POWER
47.5W
8.0%
2.0%
2.0%
0.5%
3.0%
4.0%
200ms, 15ms/230VAC
200ms, 15ms/115VAC at full load
HOLD UP TIME (Typ.)
70ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
79%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.1A/115VAC
COLD START 60A/230VAC
LEAKAGE CURRENT
For earth <200uA/264VAC, For patient <100uA/264VAC
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
80mVp-p
80mVp-p
+3,-2%
80mVp-p
8.0%
+6,-10%
0.5%
1.0%
2.0%
1.5%
2.0%
+5.5,-5%
15ms/115VAC at full load
127 ~ 370VDC
75%
0.7A/230VAC
30A/115VAC
115 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
CH1: 3.8 ~ 4.45V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +65
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
EMS IMMUNITY
MTBF
677.8Khrs min. MIL-HDBK-217F (25 )
DIMENSION
PACKING
NOTE
6.0%
1.5%
WORKING TEMP.
OTHERS
80mVp-p
LOAD REGULATION
SETUP, RISE TIME
OVER VOLTAGE
(Note 5)
43.9W
150mVp-p
LINE REGULATION
PROTECTION
CH3
39.9W
PEAK LOAD(10sec.) Note.4 52.25W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 +3,-2%
OVERLOAD
EMC
RPT-6003
OUTPUT NUMBER
DC VOLTAGE
101.6*50.8*29mm (L*W*H)
0.15Kg; 96pcs/15.4Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
R P T- 6 0
60W Triple Output Medical Type
Mechanical Specification
series
Unit:mm
101.6
3.175
44.45
50.8
3.175
95.25
3
2
1
CN1
1
2
3
4
5
6
CN2
3 max.
29
4- 3.3
DC Output Connector (CN2) : JST B6P-VH or equivalent
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Pin No.
1,2
3,4
5
6
Assignment
V1
COM
V2
V3
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Block Diagram
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
V3
RECTIFIERS
&
FILTER
+V2
RECTIFIERS
&
FILTER
+V1
COM
DETECTION
CIRCUIT
FG
O.L.P.
fosc : 100KHz
RECTIFIERS
&
FILTER
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30
40
AMBIENT TEMPERATURE (
50
)
60 65 70 (HORIZONTAL)
60
50
40
90
95
100
115
120
140
160
180
200
220
INPUT VOLTAGE (VAC) 60Hz
240
264