R P T- 7 5 75W Triple Output Medical Type series Features : Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Free air convection for rated power and 23.5CFM forced air convection for peak load UL60601-1/IEC60601-1/EN60601-1 medical safety approved Fixed switching frequency at 65KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION OUTPUT INPUT CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 6A 3A 0.5A 6A 3A 0.5A 6A 2.3A 0.5A CURRENT RANGE 0.6 ~ 8A 0.2 ~ 4A 0.1 ~ 1A 0.6 ~ 8A 0.2 ~ 4A 0.1 ~ 1A 0.6 ~ 8A 0.1 ~ 3A 0.1 ~ 1A RATED POWER 68.5W PEAK LOAD (23.5CFM) 93W 150mVp-p 150mVp-p 120mVp-p 80mVp-p 100W 120mVp-p 120mVp-p 80mVp-p 5.0% 2.0% 6.0% 5.0% 2.0% 8.0% 5.0% LINE REGULATION 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% LOAD REGULATION 1.5% 3.0% 1.0% 1.5% 3.0% 1.0% 1.5% 3.0% 1.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE EFFICIENCY(Typ.) 47 ~ 63Hz 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 1A/230VAC COLD START 25A/115VAC 50A/230VAC WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 500ms, 30ms/115VAC at full load 20ms/115VAC at full load 127 ~ 370VDC 77% 77% Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC 140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A EMS IMMUNITY ISOLATION RESISTANCE MTBF NOTE 100W 120mVp-p CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0% OVER VOLTAGE OTHERS 72W VOLTAGE ADJ. RANGE OVERLOAD (Note 4) 72W RIPPLE & NOISE (max.) Note.2 80mVp-p PROTECTION EMC RPT-75C OUTPUT NUMBER LEAKAGE CURRENT SAFETY & RPT-75B RPT-75A MODEL DIMENSION PACKING 521.2K hrs min. MIL-HDBK-217F (25 127*76.2*31mm (L*W*H) 0.26Kg; 63pcs/17.4Kg/1.35CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPT-75-SPEC 2008-03-25 R P T- 7 5 75W Triple Output Medical Type series Features : Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Free air convection for rated power and 23.5CFM forced air convection for peak load UL60601-1/IEC60601-1/EN60601-1 medical safety approved Fixed switching frequency at 65KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION RPT-75D MODEL OUTPUT INPUT CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 24V 12V 3.3V 5V 12V RATED CURRENT 5A 1.5A 1A 6A 6A 1A CURRENT RANGE 0.6 ~ 7A 0.1 ~ 2A 0.1 ~ 1A 0.7 ~ 7A 0 ~ 8A 0 ~ 1.5A RATED POWER 73W PEAK LOAD (23.5CFM) 95W 120mVp-p 120mVp-p CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 8.0% 8.0% 6.0% +10,-6% 0.5% 1.0% 1.0% 1.0% 1.0% 1.5% LOAD REGULATION 1.5% 3.0% 3.0% +3,-4% +5,-4% 6.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE EFFICIENCY(Typ.) 47 ~ 63Hz 79% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 1A/230VAC COLD START 25A/115VAC 50A/230VAC WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 500ms, 30ms/115VAC at full load 20ms/115VAC at full load 127 ~ 370VDC 74% Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC 140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V CH1: 3.8 ~ 4.45V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3 heavy industry level, EN61204-3 medical level, criteria A EMS IMMUNITY ISOLATION RESISTANCE MTBF NOTE 80mVp-p LINE REGULATION OVER VOLTAGE OTHERS 120mVp-p -----4.0% OVERLOAD (Note 4) 81W 200mVp-p VOLTAGE ADJ. RANGE PROTECTION EMC 61.8W RIPPLE & NOISE (max.) Note.2 80mVp-p LEAKAGE CURRENT SAFETY & RPT-7503 OUTPUT NUMBER DIMENSION PACKING 521.2K hrs min. MIL-HDBK-217F (25 127*76.2*31mm (L*W*H) 0.26Kg; 63pcs/17.4Kg/1.35CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPT-75-SPEC 2008-03-25 R P T- 7 5 75W Triple Output Medical Type Mechanical Specification series Unit:mm FAN 5.7 15cm 23.5CFM min. CN2 1 2 3 4 5 6 7 8 3 2 1 64.75 76.2 CN1 4115.8 5.6 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent 3.8 Pin No. 1,2 3,4,5 6,7 8 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 3max. 31 127 Assignment V1 COM V2 V3 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG CONTROL O.L.P. fosc : 65KHz RECTIFIERS & FILTER O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 133 23.5CFM Forced air Cooling 100 90 80 Convection Cooling 70 LOAD (%) LOAD (%) 80 50 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPT-75-SPEC 2008-03-25