High Speed Translator Buffer to LVCMOS FEATURES PIN CONFIGURATION (TOP VIEW) LVCMOS output Selectable Drive capability Drive 15pF or 30pF output load Single AC coupled input (min. 100mV swing). Accepts LVCMOS or Sine Wave inputs. Input range from 0 to 200 MHz. OE High (PLL130-07) or OE Low (PL130-07A) Enable 2.5V to 3.3V operation. Available in 8-Pin SOP, 8-Pin TSSOP and 3x3mm 16-Pin QFN. GND 1 8 DRV_SEL^ REF_IN 2 7 VDD GND 3 6 GND VDD 4 5 CLK_OUT SOP-8L DESCRIPTION The PLL130-07 is a low cost, high performance, high speed, buffer that reproduces any input frequency from 0 to 200MHz. It provides an LVCMOS output with 15pF output load drive capability. Any input signal with at least 100mV swing can be used as reference signal. This chip is ideal for conversion from sine wave to LVCMOS. VDD 1 8 CLK_OUT DRV_SEL 2 7 VDD GND 3 6 DNC OE 4 5 FIN TSSOP-8L 12 DRV_SEL 13 GND 14 GND 15 OE 16 11 10 9 8 CLK_OUT 7 VDD PLL130-07(A) 1 2 3 4 6 N/C 5 GND BLOCK DIAGRAM REF_IN Input CLK_OUT Amplifier OE 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 11/14/07 Page 1 High Speed Translator Buffer to LVCMOS PIN DESCRIPTION Name SOP-8L TSSOP-8L QFN-16L Type Description GND 1,3,6 3 1,2,4,5, 9,14,15 P Ground. VDD 4,7 1,7 7,10,11,12 P Power supply. DRV_SEL 8 2 13 I REF_IN 2 5 3 I CLK_OUT 5 8 8 O Drive Select input: ‘1’ for standard drive, ‘0’ for hidrive output. Internal pull-up (default is ‘1’). Reference input signal. The frequency of this signal will be reproduced at the output (after translation to CMOS level). CMOS clock output. OE N/A 4 16 I Output Enable. See OE LOGIC TABLE below OE LOGIC TABLE Part Number PLL130-07 PLL130-07A OE State Output Buffer State 0 Tri-State 1 (Default) Active 0 (Default) Active 1 Tri-State ELECTRICAL SPECIFICATIONS 1. Absolute Maximum Ratings PARAMETERS Supply Voltage SYMBOL MIN. V DD MAX. UNITS 4.6 V Input Voltage, dc VI -0.5 V DD +0.5 V Output Voltage, dc VO -0.5 V DD +0.5 V Storage Temperature TS -65 150 C Ambient Operating Temperature* TA -40 85 C Junction Temperature TJ 125 C Lead Temperature (soldering, 10s) 260 C ESD Protection, Human Body Model 2 kV Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the device and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other conditions above the operational limits noted in this specification is not implied. * Note: Operating Temperature is guaranteed by design for all parts (COMMERCIAL and INDUSTRIAL), but tested for COMMERCIAL grade only. 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 11/14/07 Page 2 High Speed Translator Buffer to LVCMOS 2. AC Specifications PARAMETERS CONDITIONS MIN. Input Frequency TYP. 0 Input Signal Swing REF_IN input MAX. UNITS 200 MHz 100 Output Frequency mV 0 200 MHz MAX. UNITS 3. CMOS Output Electrical Specifications PARAMETERS SYMBOL CONDITIONS Output High Voltage V OH I OH = -12mA Output Low Voltage V OL I LO = 12mA Output High Voltage at CMOS level V OHC I OH = -4mA Output Drive Current MIN. TYP. 2.4 V 0.4 V DD – 0.4 V V At TTL level (High Drive*) 36 51 mA At TTL level (Standard Drive) 12 17 mA * Note: High Drive CMOS is selectable through DRIV_SEL selector input on pin 8(SOP) or 13(QFN). 4. CMOS Switching Characteristics PARAMETERS SYMBOL CONDITIONS MIN. TYP. Output Clock Rise/Fall Time tr / tf 0.8V ~ 2.0V with 10 pF load 1.15 tr / tf 0.3V ~ 3.0V with 15 pF load 3.7 Output Clock Rise/Fall Time (High Drive*) tr / tf 0.8V ~ 2.0V with 10 pF load 0.5 tr / tf 0.3V ~ 3.0V with 15 pF load 1.5 MAX. UNITS ns * Note: High Drive CMOS is selectable through DRIV_SEL selector input on pin 8(SOIC) or 13(QFN). 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 11/14/07 Page 3 High Speed Translator Buffer to LVCMOS PACKAGE DRAWINGS (GREEN PACKAGE COMPLIANT) 8 PIN ( dimensions in mm ) TSSOP SOP Min. Max. Min. A 1.47 1.73 - 1.20 Symbol Max. A1 0.10 0.25 0.05 0.15 B 0.33 0.51 0.19 0.30 C 0.19 0.25 0.09 0.20 D 4.80 4.95 2.90 3.10 E 3.80 4.00 4.30 4.50 H 5.80 6.20 6.20 6.60 L 0.38 1.27 0.45 0.75 e 1.27 BSC 0.65 BSC E H D A A 1 C L e B QFN-16L Dimensions in MM 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 11/14/07 Page 4 High Speed Translator Buffer to LVCMOS ORDERING INFORMATION (GREEN PACKAGE COMPLIANT) For part ordering, please contact our Sales Department: 47745 Fremont Blvd., Fremont, CA 94538, USA Tel: (510) 492-0990 Fax: (510) 492-0991 PART NUMBER The order number for this device is a combination of the following: Device number, Package type and Operating temperature range PLL130-07(A) X C PART NUMBER TEMPERATURE C=Commercial I=Industrial OE STATE None= High Enable A=Low Enable PACKAGE TYPE O=TSSOP-8L Q=QFN-16L S=SOP-8L Order Number Marking Package Option PLL130-07OC-R PLL130-07OC PLL130-07AOC-R PLL130-07AOC PLL130-07QC-R PLL130-07AQC-R PLL130-07SC-R PLL130-07SC PLL130-07ASC-R PLL130-07ASC P130-07OC P130-07OC P130-07AOC P130-07AOC P130-07QC P130-07AQC P130-07SC P130-07SC P130-07ASC P130-07ASC TSSOP - Tape and Reel TSSOP – Tube TSSOP - Tape and Reel TSSOP - Tube QFN - Tape and Reel QFN - Tape and Reel SOP -Tape and Reel SOP – Tube SOP-Tape and Reel SOP - Tube PhaseLink Corporation, reserves the right to make changes in its products or specifications, or both at any time without notice. The information furnished by Phaselink is believed to be accurate and reliable. However, PhaseLink makes no guarantee or warranty concerning the accuracy of said information and shall not be responsible for any loss or damage of whatever nature resulting from the use of, or reliance upon this product. LIFE SUPPORT POLICY: PhaseLink’s products are not authorized for use as critical components in life support devices or systems without the express written approval of the President of PhaseLink Corporation. 47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 11/14/07 Page 5