open frame solenoids

OPEN FRAME SOLENOIDS
1. Design and Features
The open frame solenoid is the simplest form of construction of all the types of solenoids manufactured,
and is shown in Fig. 1. Though the design is simple
in construction, obtaining maximum performance
requires the use of high permeable steel, and good
quality manufacturing technology to assure the
minimizing of air gaps in the metal frame assembly.
Additionally, high quality coil winding techniques are
used to maximize the number of coil windings that are
housed in the allowable space.
B) Return Spring
The open frame solenoid does not include a return
spring. Therefore, the application must include a return
spring.
C) Plunger and Shaft Modifications
It is not recommended that customer modify the plunger
or shaft, as the shafts are manufactured and plated at
the factory. Any special configurations can be supplied.
Please consult the factory for details.
D) Installation of Solenoid
The open frame solenoid uses tapped holes for mounting in the frame.
Caution needs to be observed that the mounting screws
used to attach these solenoids are the correct length so
as not to damage the coil.
4. General Characteristics
Insulation class
Fig. 1
2. Stroke and Force
The open frame solenoid is designed for long strokes.
As such, the pole piece designs are conical to maximize
performance over longer strokes. To improve efficiency,
the solenoid stroke should be minimized in the application.
Class A (105°C)
Lead wire class A (105°C)
Dielectric strength
AC 1000V 50/60 Hz 1 min.
(at normal temperature and
normal humidity)
Insulation resistance More than 100 Mohm at DC
500V megger
(at normal temperature and
normal humidity)
Expected life
300,000 cycles
(Solenoid cycle life is very dependent upon side load,
frequency of use, and environmental conditions.
Cycle life tests should be performed by the customer.)
3. Operational Considerations
A) Temperature
The coil data for the open frame solenoids shows the
values at ambient temperature 20°C and with a standard heat sink. If a solenoid is used at a rating shown in
the coil data, it is designed so that the coil temperature
rises and reaches equilibrium at approximately 65°C.
In applications where the ambient temperature is higher
than 40°C, possible thermal damage can occur.
Temperature rise tests should be performed by the
customer to assure that the coil does not reach 105°C.
Coils can be constructed to operate at temperatures
higher than 105°C without thermal damage. Please
consult the factory for details.
70
5. How to Select a Solenoid
Before selecting an open frame solenoid, the following
information must be determined :
A) Force
The actual force required in the application should be
increased using a safety factor multiplier of 1.3 to
arrive at the force value that should be used in your
specification.
B) Duty Cycle
Use the aforementioned formula to calculate duty
cycle. Also note the maximum on time. (See page2)
C) Stroke
Stroke is determined by application requirements.
www.shindengen.co.jp/smt/
OPEN FRAME SOLENOIDS
D) Operating Voltage
Operating DC voltage is determined by the application
and voltage available.
After determining these specifications, one can find the
correct size solerioid for the application, using the
force-stroke characteristic tables and graphs. The coil
data is also shown for different sizes of magnet wire. If
the exact operating voltages is not in the coil data table,
please consult the factory for details.
To determine the force output of the solenoid after
temperature rise, please use the amp-turn force graphs
(page 100) after calculating the amp-turns.
6. Ordering Information
#When ordering an open frame solenoid, the correct
part number needs to be determined, from the catalog information,
#Example of a complete part number :
SK0520A06AA
Open Frame Solenoids
7. Labeling
For open frame solenoids the part number labeling is
as follows :
A) Standard Solenoid (no modifications).
The solenoid label will have the part number and
the date code (which identifies the year and week of
manufacture).
Example :
SK0520A06AA
9405
Solenoid Size (Type No.)
Date Code (year and week)
B) Special Configuration (required for any modification to a standard design)
Any change from the standard catalog design
requires that a custom part number be assigned,
which will also include the date code of manufacture.
Example :
M93020F
9405
Special Part Number
Date Code (year and week)
www.shindengen.co.jp/smt/
71
SK0315A OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
3
AT20°C
1W
100%
4
10W
10%
0.5
4W
25%
2W
50%
0.1
0.05
WEIGHT : 5g
PLUNGER: 1g
RESPONSE TIME [N]
FORCE [N]
1
0.5
1
STROKE [mm]
1.5
4W
25%
2
10W
10%
1
1W 100%
0
2W
50%
50%
3
0
2
0
STROKE-FORCE
0.5
1
STROKE [mm]
1.5
2
STROKE-RESPONSE TIME
17.5
2-M2 0.4
15±0.3
4±0.2
φ3±0.05
8±0.3
(4.5)
(0.5)
LEADS 240MIN.
10±0.3
(UL1571 AWG28)
5±0.2
7.5±0.5
(3)
14.5±0.5
φ1.2+0.3
1.6±0.2
0.5±0.2
FRAME THK. 1.0mm POSSIBLE EXTRUSION:LESS THAN 0.3mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
50
18
1.0
ampere-turns at 20˚C
type no.
100%
continuous
140
2.0
4.0
198
no. turns
10%
or less
2
10.0
280
442
12
19
volts DC
SK0315A06AA
36
920
6
SK0315A12AA
144
1750
12
17
24
38
SK0315A24AA
576
3370
24
34
48
76
SK0315A48AA
2304
6700
48
68
96
152
72
www.shindengen.co.jp/smt/
8.5
SK0420F OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
RESPONSE TIME [N]
FORCE [N]
0.5
0.1
0.05
0.03
0.7W
100%
32
1
WEIGHT : 8g
PLUNGER: 2g
AT20°C
40
3
0
1
2
3
4
STROKE [mm]
5
7W
10%
2.8W
25%
1.4W
50%
0.7W
100%
6
1.4W
50%
24
2.8W
25%
16
7W
10%
8
0
0
STROKE-FORCE
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
20±0.3
LEADS 240MIN.
(4)
(UL1571 AWG28)
φ4±0.05
2-M2 0.4
(0.7)
11±0.3
±0.5
Open Frame Solenoids
3.5±0.2
7.5±0.3
24
±0.2
12.3
7
(4.3)
19.7±0.3
φ1.6±0.2
0.7±0.2
1±0.2
FRAME THK. 1.0mm POSSIBLE EXTRUSION:LESS THAN 0.3mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
50
18
0.7
ampere-turns at 20˚C
type no.
100%
continuous
119
1.4
2.8
168
no. turns
10%
or less
2
7.0
238
376
12
19
volts DC
SK0420F06AA
51
1100
6
SK0420F12AA
205
2120
12
17
24
38
SK0420F24AA
823
4100
24
34
48
76
SK0420F48AA
3291
8100
48
68
96
152
www.shindengen.co.jp/smt/
8.5
73
SK0520A OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
10
50%
1
16W
10%
0.5
6.4W
25%
3.2W
50%
WEIGHT : 22g
PLUNGER: 4g
0.1
0
1
2
3
4
STROKE [mm]
5
1.6W
100%
20
RESPONSE TIME [N]
FORCE [N]
5
AT20°C
24
16
3.2W
50%
12
6.4W
25%
8
16W
10%
4
1.6W
100%
6
0
0
STROKE-FORCE
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
30.5
4-M2.6 0.45
21±0.3
7±0.2
14±0.3
φ5±0.05
(6.5)
φ2+0.1
0
(0.5)
17.8±0.3
LEADS 240MIN.
±0.2
2.5
(UL1007 AWG28)
13.5±0.5
(10.5)
8±0.2
20±0.5
FRAME THK. 1.2mm POSSIBLE EXTRUSION:LESS THAN 0.3mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
55
19
1.6
ampere-turns at 20˚C
type no.
100%
continuous
300
3.2
6.4
424
no. turns
10%
or less
3
16.0
600
948
12
19
volts DC
SK0520A06AA
23
1150
6
SK0520A12AA
90
2290
12
17
24
38
SK0520A24AA
360
4500
24
34
48
76
SK0520A48AA
1440
8600
48
68
96
152
74
www.shindengen.co.jp/smt/
8.5
SK0626A OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
20
AT20°C
20
2.5W
100
10
RESPONSE TIME [N]
16
FORCE [N]
5
WEIGHT : 43g
PLUNGER: 7g
25W
10%
1
10W
25%
0.5
5W
50%
0.2
12
1
2
3
4
STROKE [mm]
5
10W
25%
25W
10%
8
4
2.5W
100
0
5W
50%
0
6
STROKE-FORCE
0
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
38
2-M3 0.5
(0.6)
3±0.2
±0.5
14
Open Frame Solenoids
φ2+0.1
0
20±0.3
7±0.2
(5)
φ6±0.05
16±0.3
26.8±0.3
±0.2
16
LEADS 240MIN.
(UL1007 AWG26)
(12)
26±0.5
±0.3
1.8±0.3
7
FRAME THK. 1.6mm POSSIBLE EXTRUSION:LESS THAN 0.5mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
100
36
2.5
ampere-turns at 20˚C
type no.
100%
continuous
428
5.0
10.0
605
no. turns
10%
or less
7
25.0
856
1353
12
19
volts DC
SK0626A06AA
14
1090
6
SK0626A12AA
58
2090
12
17
24
38
SK0626A24AA
230
4110
24
34
48
76
SK0626A48AA
922
8200
48
68
96
152
www.shindengen.co.jp/smt/
8.5
75
SK0640C OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
20
RESPONSE TIME [N]
10
5
25W
10%
FORCE [N]
WEIGHT : 48g
PLUNGER: 9g
AT20°C
24
10W
25%
1
5W
50%
0.5
2.5W
100
20
2.5W
100
16
5W
50%
10W
25%
25W
10%
12
8
4
0.2
0
0
1
2
3
4
STROKE [mm]
5
6
0
STROKE-FORCE
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
50.5
2-M3 0.5
13.5±0.3
(10.5)
40±0.3
φ6±0.05
(9)
φ3+0.1
0
(0.5)
3.5±0.2
20±0.3
20±0.2
12±0.2
18±0.5
LEADS 240MIN.
(UL1007 AWG26)
FRAME THK. 2.0mm POSSIBLE EXTRUSION:LESS THAN 1.0mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
100
36
2.5
ampere-turns at 20˚C
type no.
100%
continuous
504
5.0
10.0
712
no. turns
10%
or less
7
25.0
1008
1593
12
19
volts DC
SK0640C06AA
14
1185
6
SK0640C12AA
58
2480
12
17
24
38
SK0640C24AA
230
4830
24
34
48
76
SK0640C48AA
922
9460
48
68
96
152
76
www.shindengen.co.jp/smt/
8.5
SK0730A OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
20
AT20°C
20
2.5W
100
10
RESPONSE TIME [N]
16
5
FORCE [N]
25W
10%
10W
25%
1
5W
50%
0.5
0.2
0
1
2
5
3
4
STROKE [mm]
12
10W
25%
8
25W
10%
4
2.5W
100
WEIGHT : 48g
PLUNGER: 8g
5W
50%
0
6
STROKE-FORCE
φ2+0.1
0
34.3±0.5
1
0
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
3-M2.6 0.45
30.3±0.3
2.5±0.2
20±0.3
10±0.2
Open Frame Solenoids
φ16±0.3
5.5±0.1
φ7±0.05
(8)
(0.5)
+0.2
-0.5
12.8
LEADS 240MIN.
(UL1007 AWG26)
11±0.2
(4.8)
29.5±0.5
FRAME THK. 1.6mm POSSIBLE EXTRUSION:LESS THAN 0.5mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
100
36
2.5
ampere-turns at 20˚C
type no.
100%
continuous
389
5.0
10.0
550
no. turns
10%
or less
7
25.0
778
1230
12
19
volts DC
SK0730C06AA
14
990
6
SK0730C12AA
58
1925
12
17
24
38
SK0730C24AA
230
3730
24
34
48
76
SK0730C48AA
922
7300
48
68
96
152
www.shindengen.co.jp/smt/
8.5
77
SK0832A OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°
50
AT20°
20
3W
100
RESPONSE TIME [N]
16
FORCE [N]
10
12W
25%
6W
50%
3W
100
1
0.5
0
1
2
WEIGHT : 82g
PLUNGER: 14g
3
4
STROKE [mm]
5
12W
25%
12
30W
10%
5
6W
50%
30W
10%
8
4
0
6
0
STROKE-FORCE
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
46
33±0.3
4-M3 0.5
(7)
15
22±0.3
±0.2
φ8±0.05
φ3
φ3+0.1
0
26
(0.9)
±0.3
5±0.2
16±0.5
(14)
18±0.2
LEADS 240MIN.
(UL1007 AWG26)
32±0.5
±0.3
2±0.3
10
FRAME THK. 1.6mm POSSIBLE EXTRUSION:LESS THAN 0.5mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
100
36
3.0
ampere-turns at 20˚C
type no.
100%
continuous
571
6.0
12.0
807
no. turns
10%
or less
7
30.0
1142
1805
12
19
volts DC
SK0832A06AA
12
1150
6
SK0832A12AA
46
2300
12
17
24
38
SK0832A24AA
186
4430
24
34
48
76
SK0832A48AA
743
8410
48
68
96
152
78
www.shindengen.co.jp/smt/
8.5
SK0836W OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
50
AT20°C
20
4W
100
FORCE [N]
10
RESPONSE TIME [N]
16
40W
10%
5
12
16W
25%
8W
50%
WEIGHT : 100g
PLUNGER: 14g
0.5
0
1
2
3
4
STROKE [mm]
5
16W
25%
40W
10%
8
4
4W
100
1
8W
50%
0
6
STROKE-FORCE
0
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
46.5
4-M3 0.5
37±0.3
20±0.3
8±0.2
8±0.05
(10)
Open Frame Solenoids
φ3+0.1
0
26±0.3
(0.5)
4±0.2
±0.5
12.5
(10.5)
±0.2
20
LEADS 240MIN.
(UL1007 AWG26)
36±0.5
±0.3
2.2±0.3
8
FRAME THK. 2.0mm POSSIBLE EXTRUSION:LESS THAN 0.5mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
100
36
4.0
ampere-turns at 20˚C
type no.
100%
continuous
666
8.0
16.0
941
no. turns
10%
or less
7
40.0
1332
2106
12
19
volts DC
SK0836W06AA
9
1000
6
SK0836W12AA
36
2000
12
17
24
38
SK0836W24AA
144
4000
24
34
48
76
SK0836W48AA
576
7540
48
68
96
152
www.shindengen.co.jp/smt/
8.5
79
SK0946A OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
50
AT20°C
24
3W
100
FORCE [N]
10
RESPONSE TIME [N]
20
30W
10%
5
12W
25%
6W
50%
WEIGHT : 96g
PLUNGER: 20g
0.5
16
12W
25%
12
30W
10%
8
4
3W
100
1
6W
50%
0
0
1
2
3
4
STROKE [mm]
5
0
6
STROKE-FORCE
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
56.5
4-M3 0.5
46.5±0.3
19±0.3
10±0.2
φ9±0.05
(8.5)
23±0.3
φ3+0.1
0
(0.5)
±0.2
16
4
±0.5
LEADS 240MIN.
±0.2
28
(UL1007 AWG26)
(11)
45.5±0.5
3±0.3
8±0.3
FRAME THK. 1.6mm POSSIBLE EXTRUSION:LESS THAN 0.8mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
100
36
3.0
ampere-turns at 20˚C
type no.
100%
continuous
585
6.0
12.0
827
no. turns
10%
or less
7
30.0
1170
1849
12
19
volts DC
SK0946A06AA
12
1120
6
SK0946A12AA
48
2320
12
17
24
38
SK0946A24AA
192
4680
24
34
48
76
SK0946A48AA
768
9000
48
68
96
152
80
www.shindengen.co.jp/smt/
8.5
SK1040A OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
50
AT20°C
24
4.2W
100
RESPONSE TIME [N]
FORCE [N]
20
42W
10%
10
5
16.8W
25%
8.4W
50%
8.4W
50%
16.8W
25%
16
12
42W
10%
8
4
4.2W
100
1
WEIGHT : 136g
PLUNGER: 23g
0
1
2
3
4
STROKE [mm]
5
0
6
0
STROKE-FORCE
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
4-M3 0.5
50
40±0.3
19.4
24±0.3
±0.2
φ10±0.05
(12)
φ3+0.1
0
Open Frame Solenoids
29±0.3
(0.5)
3±0.2
17±0.5
LEADS 240MIN.
18±0.2
(UL1007 AWG26)
(11)
39±0.5
3±0.3
8±0.3
FRAME THK. 2.0mm POSSIBLE EXTRUSION:LESS THAN 1.0mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
100
36
4.2
ampere-turns at 20˚C
type no.
100%
continuous
635
8.4
16.8
898
no. turns
10%
or less
7
42.0
1270
2008
12
19
volts DC
SK1040A06AA
9
1020
6
SK1040A12AA
34
2000
12
17
24
38
SK1040A24AA
137
3625
24
34
48
76
SK1040A48AA
549
7420
48
68
96
152
www.shindengen.co.jp/smt/
8.5
81
SK1250W OPEN FRAME SOLENOID
UNIT : mm
SHOWN ENERGIZED
AT20°C
50
60W
10%
RESPONSE TIME [N]
FORCE [N]
30
24W
25%
10
12W
50%
8
AT20°C
24
6W
100
20
12W
50%
16
24W
25%
12
60W
10%
8
6
4
6W
100
4
0
1
WEIGHT : 362g
PLUNGER: 40g
2
3
4
STROKE [mm]
5
0
6
0
STROKE-FORCE
1
2
3
4
STROKE [mm]
5
6
STROKE-RESPONSE TIME
4-M4 0.7
59
50±0.3
0
φ3 +0.1
36±0.3
20±0.2
φ12±0.05
(8)
40±0.3
4±0.2
17±0.5
30±0.2
49±0.5
3.5±0.3
10
8±0.3
(0.5)
LEADS 240MIN.
(UL1007 AWG26)
FRAME THK. 2.3mm POSSIBLE EXTRUSION:LESS THAN 1.0mm
COIL DATA
without heat sink
“on” time
duty cycle=
K100%
“on” time + “off” time
MAX. “on” time in seconds
watts at 20˚C
resistance
Ω±10%(at 20˚C)
50%
or less
25%
or less
∞
140
50
6.0
ampere-turns at 20˚C
type no.
100%
continuous
1150
12.0
24.0
1626
no. turns
10%
or less
9
60.0
2300
3636
12
19
volts DC
SK1250W06AA
6
1100
6
SK1250W12AA
24
2370
12
17
24
38
SK1250W24AA
96
4600
24
34
48
76
SK1250W48AA
384
8640
48
68
96
152
82
www.shindengen.co.jp/smt/
8.5
CHARACTERISTICS TABLES FOR OPEN FRAME
AT20°C
70
50
50
10
10
SK0946A
SK1040A
SK0836W
1
SK0832A
0.5
SK1250W
5
SK1250W
SK1040A
SK0836W
SK0946A
SK0832A
FORCE [N]
FORCE [N]
5
AT20°C
70
1
SK0640C
SK0730A
SK0626A
0.5
SK0640C
SK0730A
SK0626A
SK0520A
SK0520A
0.1
SK0315A
0.1
SK0315A
0.03
SK0420F
0.05
SK0420F
0
1
2
3
4
STROKE [mm]
5
0.03
6
0
1
2
DUTY CYCLE100%
3
4
STROKE [mm]
5
6
DUTY CYCLE 50%
AT20°C
70
AT20°C
70
50
50
SK1250W
SK1250W
10
SK1040A
SK0836W
10
SK0946A
SK1040A
SK0836W
5
SK0832A
5
SK0946A
SK0730A
SK0640C
SK0730A
SK0626A
1
0.5
SK0520A
FORCE [N]
FORCE [N]
SK0832A
SK0640C
SK0626A
1
SK0520A
SK0315A
0.5
SK0315A
SK0420F
0.1
0.1
SK0420F
0.05
0.03
0.05
0
1
2
3
4
STROKE [mm]
5
6
0.03
0
1
DUTY CYCLE 25%
2
3
4
STROKE [mm]
5
6
DUTY CYCLE 10%
www.shindengen.co.jp/smt/
83
Open Frame Solenoids
0.05
OPEN FRAME SOLENOID AMPERE-TURN V.S. FORCE
SK0520A
1
0.5
S 2
0.5
5
424
S 0.5
238
S 1
168
1
11
280
1 8
140
S 0.5
S 0.5
S 1
S 2
600
SK0420F
2
2
300
SK0315A
PERFORMANCE CURVES
ARE AT 20˚C
S 1
S 3
S 4
0.1
FORCE[N]
S 3
FORCE[N]
FORCE[N]
S 2
S 4
S 5
S 5
1
0.5
442
0.1
400
100
200
400
48
400
5
10
0.5
1
2
3
4
5
600
800
1000
AMPERE-T RNS
SK0640C
SK0730A
S
S
S
S
S
S
12
605
428
S
S
S
S
S
S
504
SK0626A
11
10
300
AMPERE-T RNS
5
20
0.5
1
2
3
4
5
8
300
AMPERE-T RNS
0.1
0.06
200
550
200
0.02
38
0.02
100
0.05
3 6
0.05
S
S
S
S
S
S
10
0.5
FORCE[N]
1
1
1008
0.5
1
15 3
FORCE[N]
FORCE[N]
5
0.5
1
2
3
4
5
1200
0.1
1400
400
600
AMPERE-T RNS
800
0.5
0.5
0.3
400
0.3
800 1000 1200 1400 1600 1800
41
FORCE[N]
2106
500
1000
1500
S
S
S
S
S
S
10
8
1500
AMPERE-T RNS
84
2000
2
1000
3636
2300
4
1626
2008
12 0
8 8
6
1000
S
S
S
S
S
S
1500
2000
2500
800 1000 1200 1400 1600 1800
AMPERE-T RNS
30
FORCE[N]
5
500
0.3
400 600
2000
1150
635
10
0.5
1
2
3
4
5
1400
5
1
SK1250W
S
S
S
S
S
S
1200
0.5
SK1040A
50
1000
10
AMPERE-T RNS
50
0.5
0.5
1
2
3
4
5
5
AMPERE-T RNS
FORCE[N]
S
S
S
S
S
S
1
1805
1
800
SK0946A
30
10
FORCE[N]
FORCE[N]
0.5
1
2
3
4
5
666
1142
80
5 1
S
S
S
S
S
S
5
1
600
AMPERE-T RNS
SK0836W
30
10
600
400
AMPERE-T RNS
SK0832A
30
0.2
200
1000 1200 1400 1600
184
1000
82
800
585
600
1332
400
11 0
1353
856
0.1
200
1230
0.5
3000
3500
AMPERE-T RNS
www.shindengen.co.jp/smt/
0.5
1
2
3
4
5
0.5
1
2
3
4
5