SKY13296-340LF - Skyworks Solutions, Inc.

DATA SHEET
SKY13296-340LF: GaAs SP4T Absorptive Switch
20 MHz–2.5 GHz
Functional Diagram
Features
●
●
●
●
●
●
Positive voltage control (0/3 V to 0/5 V)
High isolation 35 dB at 1 GHz
Integrated silicon CMOS driver
Isolated ports are absorptive
Use of external DC blocks to allow good return loss
to low frequency
Available lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C
per JEDEC J-STD-020
RFc
J4
External
Floating Caps
External
Floating Caps
J3
Description
The SKY13296-340LF is a pHEMT GaAs FET IC high isolation,
absorptive single-pole four-throw switch packaged in a lead
(Pb)-free, 4 x 4 mm, 20-lead exposed-pad plastic package for
low-cost commercial applications. The use of external DC
blocking capacitors on the RF ports and in series with the
internal RF terminations enables the user to extend the range
of good return loss to arbitrarily low frequency. This switch
is an ideal building block for filter bank switching.
NEW
J1
J2
Decoder
VDD
VCTL
VCTL
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Electrical Specifications
VCTL = 0 V/3V, T = 25 °C, PINPUT = 0 dBm, Z0 = 50 Ω, CBLOCK = 1000 pF, CBYPASS = 1000 pF, unless otherwise noted
Parameter
Frequency
Min.
Typ.
Max.
Unit
0.4
0.6
0.7
0.6
0.8
1.1
dB
dB
dB
Insertion loss
0.02–1.00 GHz
1.00–2.00 GHz
2.00–2.50 GHz
Isolation
0.02–1.00 GHz
1.00–2.00 GHz
2.00–2.50 GHz
35
25
21
40
30
26
dB
dB
dB
Return loss (Insertion loss state)
Lower freq. return loss is dependent on DC blocks
0.02–1.00 GHz
1.00–2.00 GHz
2.00–2.50 GHz
12
9
7
18
13
13
dB
dB
dB
Return loss (Isolation state)
Lower freq. return loss is dependent on DC blocks and floating caps
0.02–1.00 GHz
1.00–2.00 GHz
2.00–2.50 GHz
9.5
8.0
7.0
14
11
9
dB
dB
dB
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200613 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • September 18, 2007
1
DATA SHEET • SKY13296-340LF
Operating Characteristics
VCTL = 0 V/3V, T = 25 °C, PINPUT = 0 dBm, Z0 = 50 Ω, CBLOCK = 1000 pF, CBYPASS = 1000 pF, unless otherwise noted
Parameter
Condition
Frequency
Switching characteristics
Rise/fall time
On/Off time
10/90% or 90/10% RF
50% VCTL to 90/10% RF
Input power for 0.1 dB compression
VDD = 3 V
870 MHz
Intermodulation intercept point (IP3)
For two tone input power 8 dbm/tone
1 MHz spacing, VDD = 3 V
900 MHz
Control voltages(1)
VCTL LOW
VCTL HIGH
Min.
Typ.
13
ns
ns
16
dBm
40
dBm
0.2
VDD
3
Supply currents
Unit
25
50
0
2.75
Supply voltage (VDD)
Max.
V
V
5.5
VDD = 3 V
VCTL LOW, VCTL HIGH
V
5
5
uA
uA
1. Control voltages switch the VDD voltage to the GaAs switch.
VDD must be powered on prior to a VCTL high signal. A latch up condition may occur if a logic
high signal is applied prior to the VDD voltage.
Typical Performance Data
VCTL = 0 V/3V, T = 25 °C, PINPUT = 0 dBm, Z0 = 50 Ω, CBLOCK = 1000 pF, CBYPASS = 1000 pF, unless otherwise noted
RFc-J1 Ins
RFc-J3 Ins
0
RFc-J2 Ins
RFc-J4 Ins
J2 Iso
0
-0.2
J3 Iso
J4 Iso
-10
-20
-0.6
Isolation (dB)
Insertion Loss (dB)
-0.4
-0.8
-1.0
-1.2
-1.4
-30
-40
-50
-60
-1.6
-70
-1.8
-2.0
-80
0
0.5
1.0
1.5
2.0
2.5
3.0
0
0.5
1.0
1.5
2.0
2.5
Frequency (GHz)
Frequency (GHz)
Typical Insertion Loss
Typical Isolation RFc-J1 Path On
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
September 18, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200613 Rev. B
3.0
DATA SHEET • SKY13296-340LF
J1 Iso
J3 Iso
J4 Iso
-10
-10
-20
-20
-30
-40
-50
J2 Iso
J4 Iso
-30
-40
-50
-60
-60
-70
-70
-80
-80
0
0.5
1.0
1.5
2.0
2.5
3.0
0
0.5
1.0
1.5
2.0
2.5
Frequency (GHz)
Frequency (GHz)
Typical Isolation RFc-J2 Path On
Typical Isolation RFc-J3 Path On
J1 Iso
0
J2 Iso
J1 Input RL
J2 Output RL
J4 Input RL
J3 Iso
0
-10
J1 Output RL
J3 Input RL
J4 Output RL
3.0
J2 Input RL
J3 Output RL
-5
Return Loss (dB)
-20
Isolation (dB)
J1 Iso
0
Isolation (dB)
Isolation (dB)
0
-30
-40
-50
-10
-15
-20
-60
-25
-70
-80
0
0.5
1.0
1.5
2.0
2.5
3.0
-30
0
0.5
1.0
1.5
2.0
Frequency (GHz)
Frequency (GHz)
Typical Isolation RFc-J4 Path On
Typical Return Loss
Insertion Loss States
J1 Output RL
J3 Output RL
2.5
3.0
J2 Output RL
J4 Output RL
0
Return Loss (dB)
-5
-10
-15
-20
-25
-30
0
0.5
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Typical Return Loss
Isolation States
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200613 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • September 18, 2007
3
DATA SHEET • SKY13296-340LF
GND
GND
RFc
GND
GND
Pin Out
(Top View X-ray of Pads on Bottom of Package)
20
19
18
17
16
J4
1
15
J1
GND 4
2
14
GND 1
GND 3
3
13
GND 2
J3
4
12
J2
GND
5
11
VCTL1
9
10
VCTL2
GND
8
GND
7
GND
VDD
6
DC blocks are required on RFc, J1, J2, J3, J4.
Floating caps are required on Gnd 1, Gnd 2, Gnd 3, Gnd 4.
Truth Table
VDD
VCTL 1
VCTL 2
RFc-J1
RFc-J2
RFc-J3
RFc-J4
1
0
0
Ins. Loss
Isolation
Isolation
Isolation
1
1
0
Isolation
Ins. Loss
Isolation
Isolation
1
0
1
Isolation
Isolation
Ins. Loss
Isolation
1
1
1
Isolation
Isolation
Isolation
Ins. Loss
VDD must be powered on prior to a VCTL hgih signal.
“0” = 0 to 0.2 V.
“1” = 2.75 to VDD V.
VDD = 3 V to 5 V.
Absolute Maximum Ratings
Characteristic
Value
Pin Assignments
Pin
Symbol
Description
1
J4
RF port. Must be DC blocked with a capacitor
appropriate for lowest frequency of operation
2
GND 4
AC Ground for J4 RF port. Must be DC blocked using
a capacitor appropriate for lowest frequency of
desired input return loss on J4 port
3
GND 3
AC Ground for J3 RF port. Must be DC blocked using
a capacitor appropriate for lowest frequency of
desired input return loss on J3 port
4
J3
RF port. Must be DC blocked with a capacitor
appropriate for lowest frequency of operation
5
GND
DC Ground
6
VDD
Supply voltage for decoder
7
GND
DC Ground
8
GND
DC Ground
9
GND
DC Ground
11
VCTL 1
DC control voltage applied to decoder
10
VCTL 2
DC control voltage applied to decoder
12
J2
RF port. Must be DC blocked with a capacitor
appropriate for lowest frequency of operation
13
GND 2
AC Ground for J2 RF port. Must be DC blocked using
a capacitor appropriate for lowest frequency of
desired input return loss on J2 port
14
GND 1
AC Ground for J1 RF port. Must be DC blocked using
a capacitor appropriate for lowest frequency of
desired input return loss on J1 port
15
J1
RF port. Must be DC blocked with a capacitor
appropriate for lowest frequency of operation
16
GND
DC Ground
17
GND
DC Ground
18
RFc
RF common port. Must be DC blocked with a
capacitor appropriate for lowest frequency
of operation
VDD voltage range
2.75 < VDD < 5.5 V
RF input power @ 5.5 V
1 W, f > 500 MHz
19
GND
DC Ground
Operating temperature
-40 °C to +85 °C
20
GND
DC Ground
Storage temperature
-65 °C to +150 °C
Exposed
Paddle
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
DC Ground
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
September 18, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200613 Rev. B
DATA SHEET • SKY13296-340LF
Evaluation Board
Part Marking
Pin 1
Indicator
CBLK
PCB EVALUATION
MLF-20
(4X4 MM)
C3, C4 = use
cap
appropriate
for minimum
freq. of
operation
SKY13296-340LF
C1, C2 = use
cap
appropriate
for minimum
freq. of
operation
RFC
CBLK
CBLK
J1
J4
1
C4
C1
C3
C2
J2
CBLK
CBLK
Pin 20
S3296
XXXX
YXX
Pin 1
J3
SK40611-1
REV 1
Use cap
value
appropriate
for minimum
freq. of
operation
CBLK
5 PLACES
Gnd
VCC
VCT2
VDD VCTL2
VCT1
VCTL1
Skyworks P/N
Lot #
Date Code
Y = Calendar Year
WW = Week
QFN-20 (4 x 4)
0.008 (0.20 mm) Ref.
0.157 (4.00 mm) BSC
CBLOCK = 1000 pF for operating frequency > 20 MHz.
CBYPASS C1–C4 = 1000 pF for operating frequency > 20 MHz.
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Seating
Plane
Pin 1
Indicator
0.157
(4.00 mm)
BSC
0.085 (2.15 mm)
+ 0.004 (0.10 mm)
- 0.006 (0.15 mm)
0.029 (0.75 mm)
± 0.002 (0.05 mm)
0.042
(1.075 mm)
Exposed Pad
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
0.02
+0.03
-0.02
0.085 (2.15 mm)
+ 0.004 (0.10 mm)
- 0.006 (0.15 mm)
0.078
(2.0 mm)
0.042
(1.075 mm)
0.078 (2.0 mm) BSC
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200613 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • September 18, 2007
5
DATA SHEET • SKY13296-340LF
Copyright © 2002, 2003, 2004, 2005, 2006, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and
names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
September 18, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200613 Rev. B