InQor Railway

InQor Railway
Application Note 10/27/08 Rev. 2
InQor Railway
Application Note 10/27/08 Rev. 2
Summary
SynQor has developed the InQor product line for the industrial and transportation industries. These ruggedized converters are specifically designed for the harsh environments
associated with such applications. This application note will
address the European standards EN50155 and RIA12 and
how to meet these standards using the InQor dc-dc converters.
Introduction
EN50155 (IEC571) as well as RIA12 specify the design requirements of electrical equipment
for railway rolling stock equipment applications. Included in these specifications:
•
•
•
•
•
Input Voltage Range
Surge Protection
Power Interruption and Backup
Operational Temperature
Shock and Vibration
Operating Input Voltage Range
(Input power for rolling stock equipment may be in several voltage ranges with additional transient levels)
EN50155 (IEC571) requirements
“Electronic equipment supplied by accumulator batteries without a stabilizing device shall
operate satisfactorily for all of the values of the supply voltage within the range defined below
(measured at the input terminals of the equipment)”
• Static Input Range Definitions
- Minimum Voltage = 0.7 Vin
- Nominal Voltage = Vin
- Rated Voltage = 1.15 Vin
- Maximum Voltage = 1.25 Vin
Voltage fluctuations between 0.6 Vin and 1.4 Vin not exceeding 0.1 second shall not
cause deviation of function.
Voltage fluctuations between 1.25 Vin and 1.4 Vin not exceeding 1 second shall not
cause damage; equipment may not be fully functional during these fluctuations.
SynQor - Advancing the Power Curve
• 888-567-9596 • www.synqor.com
Page
1
InQor Railway
Application Note 10/27/08 Rev. 2
Nominal
Input Range
Transients
InQor
Input (Vin)
0.7 Vin 1.25 Vin
Low (0.1 s)
0.6 Vin
High (1 s)
1.4 Vin
12 V
8.4-15 V
7.2 V
16.8 V
12/24 V
12.6-22.5 V
10.8 V
25.2 V
24 V
16.8-30 V
14.4 V
33.6 V
36 V
25.2-45 V
21.6 V
50.4 V
48 V
33.6-60 V
28.8 V
67.2 V
72 V
50.4-90 V
43.2 V
100.8 V
42-110 V
110 V
77-138 V
66 V
154 V
66-160 V
Input Ranges
9-22 V
18-36 V*
9-75 V
9-36 V
18-75 V
18-135 V
42-160 V
34-160 V
18-75 V** 34-135 V
Table 1: Input Specifications for EN50155
*Contact SynQor Applications Engineering
**InQor (IQ36) will meet the requirements of 48 V nominal input
The InQor standard product exceeds all of the voltage and transient requirements stated in
EN50155, except for the low transient and 0.7 Vin requirement on 24 V nominal input voltage.
Surge Protection
RIA12 specifies that equipment must withstand a surge voltage of 3.5 times the nominal input
voltage for 20 ms.
Vin Nominal
3.5 Vin
24 V
84 V
36 V
126 V
48 V
168 V
72 V
252 V
110 V
385 V
Table 2: Surge Voltages
If a Transient Voltage Suppressor (TVS) is used as transient suppressor, the approximate
energy in the TVS is given by the following equation:
E = ( 3.5 Vin – Vtvs ) x Vtvs x t
Rs
E = ( 385 V – 160 V ) x 160 V x .02 = 3600 joules
0.2
A typical SMB package 160 V TVS can only dissipate on the order of 10 joules, making a TVS imprac-
SynQor - Advancing the Power Curve
• 888-567-9596 • www.synqor.com
Page
2
InQor Railway
Application Note 10/27/08 Rev. 2
tical. A surge isolation circuit is required and component values will be determined by the amplitude,
duration and converter input power level.
Q1
D6
D1
D5
Vcc
R2
Error
Amp
C2
C1
Vcc
Soft
Start
Vcc
OSC
R1
Ref
Figure 1: Surge isolation block diagram
Circuit Description
The diagram above is designed to protect the converter from large transients. Each input voltage and transient specification will require different values of critical components. A control
power source (Vcc) is required to power this active circuit.
D1
Q1
TVS will equal maximum transient voltage
MOSFET switch blocking high voltage during transients, protecting the converter. It must have a safe operating area capability compatible with the converter input power level, transient magnitude and duration.
R1/R2
A voltage divider circuit to sense the voltage at the input of the converter
Ref
Control voltage reference supplied from Vcc
Error Amp Circuit to control the voltage at the input of the converter as set by R1/R2 and
compared to a reference voltage
Soft Start Turns Q1 on gradually at startup to lower surge current
Osc
Provides gate drive to Q1 with C1, D5, D6 acting as a charge pump
C2
Decoupling and damping for input to the converter
Circuit Operation
Essentially, this circuit is a linear regulator that is set for a voltage above any normal operating
level, but lower than the maximum input voltage rating of the converter. During normal operation, the series FET is saturated and dissipates very little power. When a transient occurs, the
FET blocks the excess voltage and dissipates the transient energy while providing continuous
power to the converter at a controlled voltage.
The circuit can also function as a surge limiter on start-up, by holding the gate of Q1 low during the initial power-up time and then gradually allowing the circuit to drive it normally.
SynQor - Advancing the Power Curve
• 888-567-9596 • www.synqor.com
Page
3
InQor Railway
Application Note 10/27/08 Rev. 2
Fast Transient Specification
Equipment must also be able to withstand a direct transient of 1800V lasting 50us. The
impedance of the transient source is specified as 100Ω, with transient energy of approximately 0.1J.
To protect the converter from such a transient, the energy must be diverted from the converter’s input and the peak voltage held at or below the transient input voltage specification on the
converter’s datasheet. A TVS device is a good choice for this purpose. It should be connected
across the converter’s input terminals to take best advantage of filtering impedances between
the transient source and the converter. Any additional filtering inductance will help reduce the
current in the TVS and limit its clamping voltage. See diagram:
Transient
Current
Filter Z
Transient
Source
Converter
Figure 2. Fast transient block diagram
Power Interruption and Backup
Interruption
EN50155 (IEC571) requirements
Interruptions of up to 10 ms may occur on input voltage
Class S2: 10 ms interruptions shall not cause any equipment failure.
Supply Change Over
From EN50155
Equipment supplied with power alternatively from an accumulator battery and a stabilized
source shall operate satisfactorily as follows:
• Class C1: at 0.6 Vin during 100 ms (without interruptions)
• Class C2: during a supply break of 30 ms
Class C1 is met within the operating input voltage range of the InQor series with the exception
of the IQ24 series as described above in the Operating Input Voltage Range section.
To meet the requirements of Class C2, the capacitance at the output of the transient circuit
would have to be increased so the converter has at least minimum voltage at the end of the
line break transient to maintain its output. For higher power levels, this may be prohibitive.
Contact SynQor applications engineering.
SynQor - Advancing the Power Curve
• 888-567-9596 • www.synqor.com
Page
4
InQor Railway
Application Note 10/27/08 Rev. 2
Operational Temperature
EN50155 (IEC571) requirements
Electronic equipment shall be designed and manufactured to meet the full performance specification requirement for the selected temperature categories as stated in table 3.
Operating
Temperature
Classes
External
Ambient
Temperature
Internal
Cubicle
Temperature
Internal
Cubicle Overtemperature
Air
Temperature
Around PCB
T1
-25 to +40ºC
-25 to +55ºC
+15ºC
-25 to +70ºC
T2
-40 to +35ºC
-40 to +55ºC
+15ºC
-40 to +70ºC
T3
-25 to +45ºC
-25 to +70ºC
+15ºC
-25 to +85ºC
TX
-40 to +50ºC
-40 to +70ºC
+15ºC
-40 to +85ºC
Table 3: Ambient Temperature
The specified operating temperature of the InQor products is -40 to +100ºC case temperature.
In addition, these products can be directly mounted to a chassis for improved cooling.
Shock and Vibration
Per EN501545 the equipment shall be able to withstand, without deterioration or malfunction,
vibrations and shocks that occur in service.
•
•
•
•
•
Frequency Range: 5 to 150 Hz
Cross-over Frequency: 8.2 Hz
Displacement Amplitude: 7.5 mm
Acceleration Amplitude: 20 m/s2
Semi-sinusoidal Shock: 50 m/s2 for 50 ms
The InQor products are filled with a permanently‑elastic, thermally‑conductive encapsulant
that enables the device to survive rigorous shock and vibration conditions by mechanically
bonding all components to the case through the encapsulant.
SynQor - Advancing the Power Curve
• 888-567-9596 • www.synqor.com