Specification Sheet

RAILWAY CONVERTERS
PB169/253/254
1 0 0 - 1 3 8 W AT T S R A I LW AY D C / D C C O N V E R T E R S
Features
•
•
•
•
Input reverse polarity protected.
Input transient protected.
Input surge protection.
Meets IEC571, BRB12, BRB13 and BRB18 for input
transients and surges
SPECIFICATIONS
INPUT
Voltage
Input ripple voltage
Input reverse polarity
protection
OPERATING
PB169:
PB253:
PB254:
20-30Vdc.
18-50Vdc.
74-138Vdc.
30% of Vin
800V indefinitely.
Output current
Output power
Line & load regulation
468
PB169:
PB253:
PB254:
PB169:
PB253:
24Vdc.
24Vdc.
13.8Vdc.
4.2A.
2.9A for VIN=18-50Vdc
4.2A: VIN=20-30Vdc
PB254:
10A.
PB169:
100W.
PB253:
100W.
PB254:
138W.
±0.36Vdc (PB169/253).
±0.10Vdc (PB254).
73%–80%
Isolation
Input – Output: 1000VAC
(with VR1 & VR2 removed) Input – Ground: 1000VAC
Output – Ground: 500VAC
ENVIRONMENTAL
Operating Temperature
OUTPUT
Output voltage
Efficiency at full load
-20°C to 45°C (PB169, PB253).
-10°C to 60°C (PB254).
STANDARDS
Input transient and surge
protection
Designed to meet BRB 12, BRB 13, BRB 18
and IEC571-1.
MECHANICAL
Connections
6-way terminal block connector
Dimensions
PB169: 60 x 111x 177mm.
PB253: 60 x 111 x 177mm.
PB254: 60 X 111 X 205mm
Mounting
Four M4 slots
Doc. No. PBC9 Rev.C 28-4-11