KTA1505 -0.5A , -35V PNP Plastic Encapsulated Transistor Elektronische Bauelemente RoHS Compliant Product A suffix of ā-Cā specifies halogen & lead-free FEATURE SOT-23 Low Noise Complementary to KTC3876 Excellent hFE Linearity A L 3 3 C B Top View 1 1 K CLASSIFICATION OF hFE(1) Product-Rank KTA1505-O KTA1505-Y KTA1505-GR Range 70~140 120~240 200~400 Marking Code AZO AZY AZG E MPQ Leader Size SOT-23 3K 7 inch 2 D F G REF. A B C D E F PACKAGE INFORMATION Package 2 Millimeter Min. Max. 2.80 3.04 2.10 2.55 1.20 1.40 0.89 1.15 1.78 2.04 0.30 0.50 H REF. G H J K L J Millimeter Min. Max. 0.09 0.18 0.45 0.60 0.08 0.177 0.6 REF. 0.89 1.02 Collector 3 1 Base 2 Emitter ABSOLUTE MAXIMUM RATINGS (TA=25°C unless otherwise specified) Parameter Collector to Base Voltage Collector to Emitter Voltage Emitter to Base Voltage Collector Current - Continuous Collector Power Dissipation Junction, Storage Temperature Symbol Ratings Unit VCBO VCEO VEBO IC PC TJ, TSTG -35 -30 -5 -500 150 150, -55~150 V V V mA mW °C ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise specified) Parameter Symbol Min. Typ. Max. Unit Collector to Base Breakdown Voltage Collector to Emitter Breakdown Voltage Emitter to Base Breakdown Voltage Collector Cut-Off Current Emitter Cut-Off Current V(BR)CBO V(BR)CEO V(BR)EBO ICBO IEBO hFE(1) hFE(2) VCE(sat) VBE fT Cob -35 -30 -5 70 25 - 200 13 -0.1 -0.1 400 -0.25 -1 - V V V µA µA V V MHz pF DC Current Gain Collector to Emitter Saturation Voltage Base-emitter voltage Transition Frequency Collector Output Capacitance http://www.SeCoSGmbH.com/ 25-Jun-2014 Rev. A - Test Conditions IC= -100µA, IE=0 IC= -1mA, IB=0 IE= -100µA, IC=0 VCB= -35V, IE=0 VEB= -5V, IC=0 VCE= -1V, IC= -100mA VCE= -6V, IC= -400mA IC= -100mA, IB= -10mA VCE= -1V, IC= -100mA VCE= -6V, IC= -20mA VCB= -6V, IE=0, f=1MHz Any changes of specification will not be informed individually. Page 1 of 2 KTA1505 Elektronische Bauelemente -0.5A , -35V PNP Plastic Encapsulated Transistor CHARACTERISTIC CURVES http://www.SeCoSGmbH.com/ 25-Jun-2014 Rev. A Any changes of specification will not be informed individually. Page 2 of 2