KTA1505

KTA1505
-0.5A , -35V
PNP Plastic Encapsulated Transistor
Elektronische Bauelemente
RoHS Compliant Product
A suffix of ā€œ-Cā€ specifies halogen & lead-free
FEATURE
SOT-23
Low Noise
Complementary to KTC3876
Excellent hFE Linearity
A
L
3
3
C B
Top View
1
1
K
CLASSIFICATION OF hFE(1)
Product-Rank
KTA1505-O
KTA1505-Y
KTA1505-GR
Range
70~140
120~240
200~400
Marking Code
AZO
AZY
AZG
E
MPQ
Leader Size
SOT-23
3K
7 inch
2
D
F
G
REF.
A
B
C
D
E
F
PACKAGE INFORMATION
Package
2
Millimeter
Min.
Max.
2.80
3.04
2.10
2.55
1.20
1.40
0.89
1.15
1.78
2.04
0.30
0.50
H
REF.
G
H
J
K
L
J
Millimeter
Min.
Max.
0.09
0.18
0.45
0.60
0.08
0.177
0.6 REF.
0.89
1.02
Collector
3
1
Base
2
Emitter
ABSOLUTE MAXIMUM RATINGS (TA=25°C unless otherwise specified)
Parameter
Collector to Base Voltage
Collector to Emitter Voltage
Emitter to Base Voltage
Collector Current - Continuous
Collector Power Dissipation
Junction, Storage Temperature
Symbol
Ratings
Unit
VCBO
VCEO
VEBO
IC
PC
TJ, TSTG
-35
-30
-5
-500
150
150, -55~150
V
V
V
mA
mW
°C
ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise specified)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Collector to Base Breakdown Voltage
Collector to Emitter Breakdown Voltage
Emitter to Base Breakdown Voltage
Collector Cut-Off Current
Emitter Cut-Off Current
V(BR)CBO
V(BR)CEO
V(BR)EBO
ICBO
IEBO
hFE(1)
hFE(2)
VCE(sat)
VBE
fT
Cob
-35
-30
-5
70
25
-
200
13
-0.1
-0.1
400
-0.25
-1
-
V
V
V
µA
µA
V
V
MHz
pF
DC Current Gain
Collector to Emitter Saturation Voltage
Base-emitter voltage
Transition Frequency
Collector Output Capacitance
http://www.SeCoSGmbH.com/
25-Jun-2014 Rev. A
-
Test Conditions
IC= -100µA, IE=0
IC= -1mA, IB=0
IE= -100µA, IC=0
VCB= -35V, IE=0
VEB= -5V, IC=0
VCE= -1V, IC= -100mA
VCE= -6V, IC= -400mA
IC= -100mA, IB= -10mA
VCE= -1V, IC= -100mA
VCE= -6V, IC= -20mA
VCB= -6V, IE=0, f=1MHz
Any changes of specification will not be informed individually.
Page 1 of 2
KTA1505
Elektronische Bauelemente
-0.5A , -35V
PNP Plastic Encapsulated Transistor
CHARACTERISTIC CURVES
http://www.SeCoSGmbH.com/
25-Jun-2014 Rev. A
Any changes of specification will not be informed individually.
Page 2 of 2