SM1211 RF Module User`s Guide

Users Guide
SM1211 RF module
ADVANCED COMMUNICATIONS & SENSING
SM1211 RF Module
User s Guide
Revision 1.0 August 2007 © 2007 Semtech Corp.
www.semtech.com
1
Users Guide
SM1211 RF module
ADVANCED COMMUNICATIONS & SENSING
Table of Contents
1
2
3
4
5
6
Introduction......................................................................................................................................... 3
Getting Started.................................................................................................................................... 3
Schematics ......................................................................................................................................... 4
Layout ................................................................................................................................................. 4
BOM..................................................................................................................................................... 5
References .......................................................................................................................................... 5
Table of Figures
Figure 1: SM1211 Overview (top view) .............................................................................................................. 3
Figure 2: SM1211 Schematics........................................................................................................................... 4
Figure 3: SM1211 Layers Description (cut view) ................................................................................................ 4
Figure 4: SM1211 Layout (top view) .................................................................................................................. 5
Figure 5: SM1211 BOM..................................................................................................................................... 5
Revision 1.0 August 2007 © 2007 Semtech Corp.
www.semtech.com
2
Users Guide
SM1211 RF module
ADVANCED COMMUNICATIONS & SENSING
1 Introduction
The purpose of this tool is to provide a development platform of the SX1211. User can build his application
prototype by simply connecting the module to his target microcontroller and start developing his application
software. The SM1211 module integrates the SX1211 reference design (chip + external components) plus
miscellaneous useful connectors.
Note that this module is also used for the SX1211 Starter Kit.
2 Getting Started
As illustrated in figure below, the SM1211 integrates several parts:
w
Ref design: This section includes the chip but also all the external components in an optimized BOM
and form factor. When user wants to incorporate the SX1211 on his PCB, it is strongly recommended
that this reference design (i.e. schematics, placement, layout, BOM, etc...) is copied as is in final
application board to guarantee optimum performance and lowest development time and design effort.
w
uC connector: to connect the RF chip s control lines to the uC. (Cf SX1211 datasheet for uC
connections guidelines).
w
SMA connector: SMA Cable or antenna connection. Each board is delivered with its ¼ wave SMA
antenna.
w
VDD jumper: to monitor current consumption and/or apply independent power supply to the module.
When VDD jumper is on, RF module s power supply should be supplied on the uC connector.
SMA connector
Ref. design
VDD jumper
uC connector
Figure 1: SM1211 Overview (top view)
Software drivers are available in the API TN8000.18 on Semtech s website. These are implemented on
Semtech s XE8000 microcontrollers but are written in C and hence easily portable to other targets.
Revision 1.0 August 2007 © 2007 Semtech Corp.
www.semtech.com
3
Users Guide
SM1211 RF module
ADVANCED COMMUNICATIONS & SENSING
3 Schematics
Ref. Design area
Figure 2: SM1211 Schematics
C12 is a DC blocker protection for the SAW filter. It has been added for debug/dev purposes, it is not needed for
direct antenna connection.
Please note that C10 and C11 are not used.
4 Layout
As illustrated in figures below, the layout has the following characteristics:
ü very compact ref design (9x19mm) => can be easily inserted even on very small PCBs
ü standard PCB technology (2 layers, 1.6mm, std vias & clearance) => low cost
ü performance quasi insensitive to dielectric thickness => quasi zero effort portability to other PCB
technology (thickness, # of layers, etc...)
The layers description is illustrated in figure below.
Signal (35um)
Isolation (FR4, 1.6mm)
Ground plane
Figure 3: SM1211 Layers Description (cut view)
Revision 1.0 August 2007 © 2007 Semtech Corp.
www.semtech.com
4
Users Guide
SM1211 RF module
ADVANCED COMMUNICATIONS & SENSING
The layout itself is illustrated in figure below. Please contact Semtech for gerber files.
9mm
19mm
Figure 4: SM1211 Layout (top view)
5 BOM
Ref
U1
U2
Q1
Value
868MHz
915MHz
SX1211
869MHz
915MHz
12.8MHz
Tol (+/-)
Techno
Transceiver IC
SAW Filter
15ppm at 25°C
AT-cut
20ppm over -40/+85°C
2ppm/year max.
R1
1%
R2
6.8k
1%
C1
1uF
15%
X5R
C2
1uF
15%
X5R
C3
220nF
10%
X7R
C4
47nF
10%
X7R
C5
100nF
10%
X7R
C6
10nF
10%
X7R
C7
680pF
10%
X7R
C8
1.8pF
0.25pF
NPO
C9
22pF
5%
NPO
L1, L2
8.2nH
6.8nH
0.2nH
Wire wound
L3
100nH
5%
Wire wound
L4
8.2nH
5%
Multilayer
C10,C11
NC
C12*
47pF
5%
NPO
*Not part of the ref. design (not required for direct antenna connection).
Size
Comment
TQFN-32
3.8*3.8mm
5.0*3.2mm
Part# Temex S142/S110
Fundamental, Cload=15pF
Part# Siward SX5032
0402
0402
0402
0402
0402
0402
0402
0402
0402
0402
0402
0402
0402
0402
0402
0402
PA regulator
Loop filter
VDD decoupling
Top regulator decoupling
Digital regulator decoupling
PA regulator decoupling
VCO regulator decoupling
Loop Filter
Loop Filter
Matching
DC block and L4 adjust
VCO tank inductors
PA Choke
Matching
DC block
Figure 5: SM1211 BOM
6 References
Ø [1] SX1211 Datasheet
Ø [2] TN8000.18 API
Revision 1.0 August 2007 © 2007 Semtech Corp.
www.semtech.com
5
Users Guide
SM1211 RF module
ADVANCED COMMUNICATIONS & SENSING
© Semtech 2007
All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the
copyright owner. The information presented in this document does not form part of any quotation or contract, is
believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the
publisher for any consequence of its use. Publication thereof does not convey nor imply any license under
patent or other industrial or intellectual property rights. Semtech assumes no responsibility or liability
whatsoever for any failure or unexpected operation resulting from misuse, neglect improper installation, repair
or improper handling or unusual physical or electrical stress including, but not limited to, exposure to
parameters beyond the specified maximum ratings or operation outside the specified range.
SEMTECH PRODUCTS ARE NOT DESIGNED, INTENDED, AUTHORIZED OR WARRANTED TO BE
SUITABLE FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS OR OTHER CRITICAL
APPLICATIONS. INCLUSION OF SEMTECH PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE UNDERTAKEN SOLELY AT THE CUSTOMER S OWN RISK. Should a customer purchase or use Semtech
products for any such unauthorized application, the customer shall indemnify and hold Semtech and its officers,
employees, subsidiaries, affiliates, and distributors harmless against all claims, costs damages and attorney
fees which could arise.
Contact Information
Taiwan
Tel: 886-2-2748-3380
Switzerland
Fax: 886-2-2748-3390
Korea
Tel: 82-2-527-4377
Fax: 41-32-729-4001
United Kingdom
Fax: 82-2-527-4376
Shanghai
Tel: 86-21-6391-0830
Tel: 81-3-6408-0950
Fax: 81-3-6408-0951
Tel: 44-1794-527-600
Fax: 44-1794-527-601
France
Fax: 86-21-6391-0831
Japan
Tel: 41-32-729-4000
Tel: 33-(0)169-28-22-00
Fax: 33-(0)169-28-12-98
Germany
Tel: 49-(0)8161-140-123
Fax: 49-(0)8161-140-124
Semtech International AG is a wholly-owned subsidiary of Semtech Corporation, which has its headquarters in
the U.S.A
Revision 1.0 August 2007 © 2007 Semtech Corp.
www.semtech.com
6