Features
Unregulated
Converters
Custom Solutions Available
1kVDC Isolation
No External Components Required
Optional Continuous Short Circuit Protected
UL94V-0 Package Material
No Heatsink Required
Efficiency to 85%
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Description The RI series has been specifically designed for applications where board space is at a premium
since these 2 Watt converters have only a slightly larger foot print than the RO series 1 Watt
converters. With efficiencies up to 87%, the full output power is available over the operating
temperature range -40°C to +85°C and the converters can be used in ambient temperatures
of up to 100°C with derating. The wide selection of input voltage and output voltage options plus
an I/O-Isolation of 1kVDC as standard makes these converters suitable for many industrial
applications.
2 Watt
SIP4
Single Output
Selection Guide
Part
Number
SIP4
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(%)
Max
Capacitive
Load
RI-xx05S
5, 12, 15, 24
5
400
78-83
1200µF
RI-xx12S
5, 12, 15, 24
12
167
80-85
680µF
RI-xx15S
5, 12, 15, 24
15
133
80-85
680µF
(1)
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RI-0505S/P
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
±5%
Line Voltage Regulation
1.2%/1% of Vin typ.
Load Voltage Regulation
5V Output types
15% max.
(10% to 100% full load)
All others
10% max.
Output Ripple and Noise (20MHz limited)
200mVp-p max.
Operating Frequency
70% min. / 80% typ.
Minimum Load = 0%
Specifications valid for 10% minimum load only.
(tested for 1 second)
1000VDC
(rated for 1 minute)
500VAC / 60Hz
Isolation Capacitance
30pF min. / 85pF max.
Isolation Resistance
Derating-Graph
(Ambient Temperature)
1 Second
P-Suffix
Continuous
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
1.4g
Packing Quantity
42 pcs per Tube
}
Detailed Information see
Application Notes chapter "MTBF"
100
-40°C to +85°C (see Graph)
using MIL-HDBK 217F
845 x 103 hours
using MIL-HDBK 217F
160 x 103 hours
80
Output Power (%)
Operating Temperature Range (free air convection)
(+85°C)
RI
10 GΩ min.
Short Circuit Protection
MTBF (+25°C)
EN-60950-1 Certified
20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load
Isolation Voltage
RoHS
2011/65/EU
6/6
±10%
60
40
Safe Operating Area
20
0
-40
0
50
85
Operating Temperature °C
100
150
Certifications
EN General Safety
Report: SPCLVD1109103
EN60950-1:2006 + A12:2011
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
Refer to Application Notes
www.recom-power.com
REV: 0/2015
E-89
RI
Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
RI-xx05S
RI-xx12S
Efficiency / Load
100
Efficiency / Load
1205
2405
100
2412
80
60
0% 20%
40%
60%
Total Output current (%)
80%
100%
1212
60
0512
40
Efficiency %
Efficiency %
40
20
0515
80
60
0505
40
Efficiency %
Efficiency / Load
100
80
0
RI-xx15S
20
0
0% 20%
40%
60%
Total Output current (%)
80%
100%
1215
2415
20
0
0%
40%
20%
60%
80%
100%
Total Output current (%)
Deviation / Load
Deviation / Load
20.000
2405
10.000
5.000
0.000
0505
-5.000
0% 20%
40%
60%
Total Output current (%)
80%
25.000
100%
2412
15.000
20.000
0512
Deviation from Nominal (%)
1205
Deviation from Nominal (%)
Deviation from Nominal (%)
20.000
15.000
-10.000
Deviation / Load
25.000
25.000
10.000
5.000
0.000
1212
-5.000
-10.000
0% 20%
40%
60%
Total Output current (%)
80%
100%
1215
15.000
0515
10.000
5.000
0.000
2415
-5.000
-10.000
0% 20%
40%
60%
Total Output current (%)
80%
100%
RI
Notes
Note 1
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Package Style and Pinning (mm)
4 PIN SIP Package
7.55
10.20
RECOM
RI-0505S
****
4.10
0.51 typ.
RECOM
RI-0505S
****
0.51 typ.
1 2 3 4
Recommended Footprint Details
Pin Connections
Pin #
1.00 ø+0.15/–0
11.50
2.54
0.25
Bottom
View
2.03
7.62
1.27
Top View
Dual
1
-Vin
2
+Vin
3
–Vout
4
+Vout
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
2.54
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-90
REV: 0/2015
www.recom-power.com