RAC05-C - recom

Features
Regulated
Converters
●
●
●
●
●
●
POWERLINE
Universal Input 80-264VAC
High efficiency up to 77%
Isolated Output 3kVAC / 1 min
Short Circuit Protection
Meet EN55022 Class B
Low Standby Power Consumption
AC/DC-Converter
with 3 year Warranty
Compact, low cost, high efficiency, universal input switching AC/DC
power module for PCB or wired mounting with single or dual outputs.
CE marked and UL/cUL certified.
Description
5 Watt
Single / Dual
Output
Selection Guide
Part
Number
RAC05-3.3SC*
Input
Voltage
(VAC)
80-264
Output
Voltage
(VDC)
3.3
Output
Current
(max.)
1250
Efficiency
(Typ.)
70
Max.
Capacitive
Load (1+2)
12000µF
RAC05-05SC*
80-264
5
1000
73
6800µF
RAC05-09SC*
80-264
9
556
75
2500µF
RAC05-12SC*
80-264
12
420
76
1500µF
RAC05-15SC*
80-264
15
340
76
750µF
RAC05-24SC*
80-264
24
210
77
330µF
RAC05-05DC*
80-264
±5
±500
73
±3000µF
RAC05-12DC*
80-264
±12
±210
76
±560µF
RAC05-15DC*
80-264
±15
±170
76
±220µF
* add suffix /W for wired version
RoHS
2011/65/EU
6/6
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range (with derating)
Rated Power
5 Watts max.
Input Frequency (for AC Input)
115VAC / 230VAC
110mA / 70mA typ.
Inrush Current (<2ms)
115VAC / 230VAC
30A / 60A max.
Minimum Load (Specifications valid with 5% min.)
0%
No Load Power Consumption
Load Voltage Regulation
Output Ripple&Noise @115/230VAC
(20MHz limited with 100nF across output)
1.5A / Slow Blow Type
115VAC / 230VAC
±2% max.
LL-HL
±0.3% typ.
5-100% Load
±0.5% typ.
3.3V
120mV max.
All Others
150mV max.
Derating-Graph
132kHz typ.
(Ambient Temperature)
Switching Frequency (Full Load)
Efficiency (Full Load)
Hold-Up Time (Full Load)
RAC05-C
0.25W max.
Recommended External Input Fuse
Line Voltage Regulation (Full Load)
EN-60950-1 Certified
UL-60950-1 Certified
47-440Hz
Input Current (Full Load)
Output Voltage Accuracy (Full Load)
E224736
80-264VAC or 115-370VDC
see Selection Guide
115VAC
100
0.85mA max.
80
Isolation Voltage
Input-Output
3kVAC / 1minute
60
Isolation Capacitance
Input-Output
1000pF typ.
Isolation Resistance
Input-Output
1G Ω min.
Short Circuit Protection
Overvoltage Protection
(of Nominal Output Voltage)
(Natural Convection)
Storage Temperature Range
Case Material
3.3V
4.8 V- 5.4V
All Others
110% - 135%
OVC II
40
30
0
-25
0
20
40
60
80
55
75
100
Ambient Temperature Range (°C)
-25°C to +55°C (without Derating)
-25°C to +75°C (with Derating)
-40°C to +100°C
UL94V-0 Black Plastic
continued on the next page
PA-30
Safe Operating Area
Hiccup, Automatic Restart
Over Voltage Category
Operating Temperature Range (3)
Load (%)
Leakage Current
10ms typ.
REV: 0/2015
Refer to Application Notes
www.recom-power.com
RAC05-S_DC
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Potting Material
Epoxy UL94V-0
Relative Humidity
Package Weight
Packing Quantity
95% RH max.
35g / 38g
10pcs
9pcs
1pc
>400 x 10³ hours
>200 x 10³ hours
EN 55022: 2006 + A1: 2007 / Class B
EN 55024:1998 + A1:2001 + A2:2003
EN 61000-3-2:2006 / Class A
EN 61000-3-3:1995 + A1:2001 +A2:2005
IEC 61000-4-2 / Criterion B
IEC 61000-4-3 / Criterion A
IEC 61000-4-4 / Criterion B
IEC 61000-4-5 / Criterion B
IEC 61000-4-6 / Criterion A
IEC 61000-4-8 / Criterion A
IEC 61000-4-11 / Criteria B + C
Single / Dual
Single Output
Dual Output
Wired Version
Using MIL-HDBK 217F
Using MIL-HDBK 217F
CE
EMC
Harmonics
Flicker
ESD
RS
EFT
Surge
CS
PMF
Voltage Variations
MTBF (25°C)
(65°C)
Emissions
Immunity
Certifications:
UL General Safety
cUL
EN General Safety
CE
Report: E224736
Report: E224736
Report: SPCLVD1211033-1
UL-60950-1, 2nd Edition
C22.2 No. 60950-1-07, 2nd Edition
EN-60950-:2006 + A12:2011
EN55022 Class B
RAC05
Notes:
Note1: Measured @230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM for detailed information.
Note3: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
Typical Characteristics
Vin=115VAC
Vin=230VAC
80
12V
80
Efficiency (%)
Efficiency (%)
85
75
5V
70
24V
65
60
75
12V
5V
70
65
24V
60
55
50
0 10 20 30 40 50 60 70 80 90 100
Load (%)
Load (%)
Input Voltage Derating Graph
90V, 100%
Load (%)
100%
90%
80%
70%
0 10 20 30 40 50 60 70 80 90 100
264V, 100%
Safe Operating Area
80V, 80%
80
130
180
230
280
Input Voltage (VAC) Ta=25°C
www.recom-power.com
REV: 0/2015
PA-31
RAC05-S_DC
Series
POWERLINE
AC/DC-Converter
Package Style and Pinning
PCB Mout Version (Standard)
Single 50.90 / Dual 53.5
Single 25.5 / Dual 27.8
15.65
0.75±0.25
6.1
45.72
1.0mm
5.0
0.75±0.25
20.32
1.2+0.2/-0.1
Single 12.75
/ Dual 13.9 10.16
5
2
1
3
10.16
Bottom View
Top View
4
10.16
10.16
2.54
(5)
2
3
1
4
2.54
10.0
This area avoid I/O PCB trace or components
Wire Version with Suffix „/W“ (Standard)
Recommended Footprint Details
Single 50.90 / Dual 53.5
15.65
RAC05
0.75±0.25
5.0
88.0
10.0
45.72
Pin Connections
Pin #
Single Out
Dual Out
1
VAC in (N)
VAC in (N)
2
VAC in (L)
VAC in (L)
3
+VDC out
+VDC out
4
-VDC out
Com
5
no Pin
-VDC out
NC = No Connection
xx.x = ±0.5mm
xx.xx = ±0.25mm
Wire Connections
Pin #
Single out
Dual out
AWG#22
1015
VAC in (N)
VAC in (N)
2 (Brown) AWG#22
1015
VAC in (L)
VAC in (L)
3 (Red)
AWG#22
1007
+VDC out
+VDC out
4 (Black) AWG#22
1007
-VDC out
Common
5 (Orange) AWG#22
1007
no Wire
-VDC out
1 (Blue)
NC = No Connection
xx.x = ±0.5mm
xx.xx = ±0.25mm
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-32
REV: 0/2015
www.recom-power.com