Features Regulated Converters ● ● ● ● ● ● POWERLINE Universal Input 80-264VAC High efficiency up to 77% Isolated Output 3kVAC / 1 min Short Circuit Protection Meet EN55022 Class B Low Standby Power Consumption AC/DC-Converter with 3 year Warranty Compact, low cost, high efficiency, universal input switching AC/DC power module for PCB or wired mounting with single or dual outputs. CE marked and UL/cUL certified. Description 5 Watt Single / Dual Output Selection Guide Part Number RAC05-3.3SC* Input Voltage (VAC) 80-264 Output Voltage (VDC) 3.3 Output Current (max.) 1250 Efficiency (Typ.) 70 Max. Capacitive Load (1+2) 12000µF RAC05-05SC* 80-264 5 1000 73 6800µF RAC05-09SC* 80-264 9 556 75 2500µF RAC05-12SC* 80-264 12 420 76 1500µF RAC05-15SC* 80-264 15 340 76 750µF RAC05-24SC* 80-264 24 210 77 330µF RAC05-05DC* 80-264 ±5 ±500 73 ±3000µF RAC05-12DC* 80-264 ±12 ±210 76 ±560µF RAC05-15DC* 80-264 ±15 ±170 76 ±220µF * add suffix /W for wired version RoHS 2011/65/EU 6/6 Specifications (measured at TA 25°C, full load after warm-up) Input Voltage Range (with derating) Rated Power 5 Watts max. Input Frequency (for AC Input) 115VAC / 230VAC 110mA / 70mA typ. Inrush Current (<2ms) 115VAC / 230VAC 30A / 60A max. Minimum Load (Specifications valid with 5% min.) 0% No Load Power Consumption Load Voltage Regulation Output Ripple&Noise @115/230VAC (20MHz limited with 100nF across output) 1.5A / Slow Blow Type 115VAC / 230VAC ±2% max. LL-HL ±0.3% typ. 5-100% Load ±0.5% typ. 3.3V 120mV max. All Others 150mV max. Derating-Graph 132kHz typ. (Ambient Temperature) Switching Frequency (Full Load) Efficiency (Full Load) Hold-Up Time (Full Load) RAC05-C 0.25W max. Recommended External Input Fuse Line Voltage Regulation (Full Load) EN-60950-1 Certified UL-60950-1 Certified 47-440Hz Input Current (Full Load) Output Voltage Accuracy (Full Load) E224736 80-264VAC or 115-370VDC see Selection Guide 115VAC 100 0.85mA max. 80 Isolation Voltage Input-Output 3kVAC / 1minute 60 Isolation Capacitance Input-Output 1000pF typ. Isolation Resistance Input-Output 1G Ω min. Short Circuit Protection Overvoltage Protection (of Nominal Output Voltage) (Natural Convection) Storage Temperature Range Case Material 3.3V 4.8 V- 5.4V All Others 110% - 135% OVC II 40 30 0 -25 0 20 40 60 80 55 75 100 Ambient Temperature Range (°C) -25°C to +55°C (without Derating) -25°C to +75°C (with Derating) -40°C to +100°C UL94V-0 Black Plastic continued on the next page PA-30 Safe Operating Area Hiccup, Automatic Restart Over Voltage Category Operating Temperature Range (3) Load (%) Leakage Current 10ms typ. REV: 0/2015 Refer to Application Notes www.recom-power.com RAC05-S_DC Series POWERLINE AC/DC-Converter Specifications (measured at TA 25°C, full load after warm-up) Potting Material Epoxy UL94V-0 Relative Humidity Package Weight Packing Quantity 95% RH max. 35g / 38g 10pcs 9pcs 1pc >400 x 10³ hours >200 x 10³ hours EN 55022: 2006 + A1: 2007 / Class B EN 55024:1998 + A1:2001 + A2:2003 EN 61000-3-2:2006 / Class A EN 61000-3-3:1995 + A1:2001 +A2:2005 IEC 61000-4-2 / Criterion B IEC 61000-4-3 / Criterion A IEC 61000-4-4 / Criterion B IEC 61000-4-5 / Criterion B IEC 61000-4-6 / Criterion A IEC 61000-4-8 / Criterion A IEC 61000-4-11 / Criteria B + C Single / Dual Single Output Dual Output Wired Version Using MIL-HDBK 217F Using MIL-HDBK 217F CE EMC Harmonics Flicker ESD RS EFT Surge CS PMF Voltage Variations MTBF (25°C) (65°C) Emissions Immunity Certifications: UL General Safety cUL EN General Safety CE Report: E224736 Report: E224736 Report: SPCLVD1211033-1 UL-60950-1, 2nd Edition C22.2 No. 60950-1-07, 2nd Edition EN-60950-:2006 + A12:2011 EN55022 Class B RAC05 Notes: Note1: Measured @230VAC / 50Hz / Ta=25°C with constant resistant mode at full load. Note2: If used @115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM for detailed information. Note3: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met. Typical Characteristics Vin=115VAC Vin=230VAC 80 12V 80 Efficiency (%) Efficiency (%) 85 75 5V 70 24V 65 60 75 12V 5V 70 65 24V 60 55 50 0 10 20 30 40 50 60 70 80 90 100 Load (%) Load (%) Input Voltage Derating Graph 90V, 100% Load (%) 100% 90% 80% 70% 0 10 20 30 40 50 60 70 80 90 100 264V, 100% Safe Operating Area 80V, 80% 80 130 180 230 280 Input Voltage (VAC) Ta=25°C www.recom-power.com REV: 0/2015 PA-31 RAC05-S_DC Series POWERLINE AC/DC-Converter Package Style and Pinning PCB Mout Version (Standard) Single 50.90 / Dual 53.5 Single 25.5 / Dual 27.8 15.65 0.75±0.25 6.1 45.72 1.0mm 5.0 0.75±0.25 20.32 1.2+0.2/-0.1 Single 12.75 / Dual 13.9 10.16 5 2 1 3 10.16 Bottom View Top View 4 10.16 10.16 2.54 (5) 2 3 1 4 2.54 10.0 This area avoid I/O PCB trace or components Wire Version with Suffix „/W“ (Standard) Recommended Footprint Details Single 50.90 / Dual 53.5 15.65 RAC05 0.75±0.25 5.0 88.0 10.0 45.72 Pin Connections Pin # Single Out Dual Out 1 VAC in (N) VAC in (N) 2 VAC in (L) VAC in (L) 3 +VDC out +VDC out 4 -VDC out Com 5 no Pin -VDC out NC = No Connection xx.x = ±0.5mm xx.xx = ±0.25mm Wire Connections Pin # Single out Dual out AWG#22 1015 VAC in (N) VAC in (N) 2 (Brown) AWG#22 1015 VAC in (L) VAC in (L) 3 (Red) AWG#22 1007 +VDC out +VDC out 4 (Black) AWG#22 1007 -VDC out Common 5 (Orange) AWG#22 1007 no Wire -VDC out 1 (Blue) NC = No Connection xx.x = ±0.5mm xx.xx = ±0.25mm The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. PA-32 REV: 0/2015 www.recom-power.com