RAC03-SCR/277 - recom

Features
●
●
●
●
●
●
Regulated
Converters
POWERLINE
Universal Input 85-305VAC
Regulated Power Supply
Continuous Short Circuit Protection
Isolated Output 3kVAC / 1 min
Meet EN55022 and FCC Class B
Ultra-low Stand-By Power Consumption
AC/DC-Converter
with 3 year Warranty
Selection Guide
Part
Number
Input
Range
(VAC)
Output
Voltage
(VDC)
Output
Current
(mA)
Typical
Efficiency
(%)
Max.
Capacitive
(1+2)
Load
RAC03-3.3SCR/277*
85-305
3.3
900
68
22000µF
RAC03-05SCR/277*
85-305
5
600
70
10000µF
RAC03-12SCR/277*
85-305
12
250
74
1500µF
RAC03-24SCR/277*
85-305
24
125
76
200µF
NOT RECOMMENDED
FOR
NEW DESIGNS
3 Watt
Single
Output
* add „-Tray“ for Tray packaging, e.g. RAC03-05SCR/277-Tray
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range
85-305VAC or 120-430VDC
Rated Power
3 Watts
Input Frequency Range (for AC Input)
47-440Hz
Input Current (Full Load)
115VAC / 230VAC
No Load Power Consumption
70mA / 45mA typ.
85-305VAC / 47-440Hz
Inrush Current (<2ms)
75mW max.
115VAC
15A max.
230VAC
30A max.
Output Voltage
3.3V
±4% typ. / ±8% max.
5V
CE Marked
UL-60950-1 Certified
±3.5% typ. / ±5% max.
12V / 24V
±3% typ. / ±4% max.
Output Current
see Selection Guide
Hold-up Time
3.3V
250mVp-p
5V
200mVp-p
12V / 24V
150mVp-p
@ Full Load
45KHz typ.
115VAC
18ms min.
Minimum Load
10%
Line Voltage Regulation
Load Regulation (10%-100% Load)
Leakage Current
LL-HL @ Full Load
±0.7% typ. / ±1% max.
3.3V
±5.5% typ. / ±9% max.
5V
±5% typ. / ±7.5% max.
12V, 24V
±4% typ. / ±5.5% max.
85-305VAC / 47-440Hz
3kVAC / 1minute
Isolation Resistance
1GΩ min
Short Circuit Protection
Continuous, Auto Restart
Over Current Limit
105% - 150%
Over Voltage Protection (Zener diode clamp)
130%-160%
Over Voltage Category
Operating Temperature Range
Derating-Graph
(Ambient Temperature)
120
100
10uA max.
Isolation Voltage
OVC II
(5)
RAC03-SCR/277
natural convection, without derating
-25°C to +75°C
natural air convection, with derating
-25°C to +85°C
Storage Temperature Range
Output Power (%)
(4)
Switching Frequency
80
50
Safe Operating Area
60
40
20
0
-25
60 70 80 100
75
85
Ambient Temperature Range (°C)
0
20
40
-40°C to +85°C
Relative Humidity
Case Material
E224736
3.3V-24V
Output Voltage Tolerance (3)
Output Ripple & Noise
RoHS
2011/65/EU
6/6
95% RH max.
UL94V-0 Black Plastic
Potting Material
Epoxy
Refer to Application Notes
continued on next page
PA-12
REV: 0/2015
www.recom-power.com
RAC03-SCR/277
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up
Package Weight
41g typ.
Package Quantity
12pcs
„-Tray“-Version
72pcs
Physical Dimension (LxWxH)
50.3 x 50.3 x 11.0mm
RoHS
Test Report: KA/2012/91224
EMC
EN55022 Class B
Certifications
UL General Safety
File Number: E224736
UL-60950-1
EN General Safety
Report: TI20925N01-E
EN-55022: 2010 Class B, EN-55024:2010
MTBF
TA = 25°C
1300 x 103 hours
(using MIL-HDBK-217F)
TA = 75°C
160 x 103 hours
Notes:
Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contace RECOM for detailed information.
Note3: The “output voltage tolerance“ includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions.
Note4: “Ripple and Noise“ is the maximum peak-to-peak voltage value measured at the output with a 20 MHz bandwidth, at rated line voltage at full load.
Note5: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
Typical Characteristics
Ambient Temperature vs. Input Voltage
Efficiency vs. Load
RAC03-05SCR/277
305
100
300VAC
90VAC
-5
Efficiency (%)
Ambient Temperature (°C)
0
110
RAC03-SCR
/277
Input Voltage (VAC)
85 90
-10
-15
-20
80
60
277VAC
115VAC
40
230VAC
20
0
0
25
-25
50
75
100
Load (%)
Mechanical Dimension
10±2mm
L
-Vo
94±5mm
11.1mm
Wire Connections
Wire #
N
+Vo
Bottom View
50.3mm
1 (Brown)
AWG#22
1015
VAC in (L)
2 (Blue)
AWG#22
1015
VAC in (N)
3 (Red)
AWG#22
1430
+VDC out
4 (Black)
AWG#22
1430
-VDC out
Tolerance ±0.5mm unless otherwise specified
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
PA-13