RAC03-SC/277 - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
POWERLINE
30mW max of No Load Power Consumption
High efficiency up to 80%
Isolated Output 3kVAC / 1 min
Short Circuit Protection
Overvoltage Protection
Meets EN55022 and FCC Class B
Built-In Fusible Resistor
AC/DC-Converter
with 3 year Warranty
Selection Guide
Part
Number
Output
Voltage
(VDC)
RAC03-3.3SC/277
3.3
Max.
Current
(lo, max)
900mA
Total
Ripple &
Regulation (3) Noise (4)
NOT RECOMMENDED
FOR
NEW DESIGNS
Max.
Capacitive
Load (1+2)
47000µF
±6%
200mV
Efficiency
(Typ.)
71%
RAC03-05SC/277
5
600mA
±6%
150mV
76%
15000µF
RAC03-12SC/277
12
250mA
±6%
150mV
78%
2200µF
RAC03-24SC/277
24
125mA
±6%
150mV
80%
390µF
3 Watt
Single
Output
Specifications (measured at TA 25°C, full load after warm-up)
Overcurrent Limit
Switching Frequency
Isolation Voltage
Leakage Current
Isolation Resistance
Short Circuit Protection
Over-Voltage Protection
Over Voltage Category
Operating Temperature
Storage Temperature
Case Material
Potting Material
Relative Humidity
Package Weight
Package Quantity
MTBF
(using MIL-HDBK217F)
Physical
EMI
Noise Immunity
Safety Standard
EC/EN General Safety
UL General Safety
PA-8
(5)
80-305VAC or 110-430VDC
47-440Hz
115VAC/230VAC
70mA / 45mA typ.
115VAC/230VAC
15A/30A max.
80-305VAC / 47-440Hz
30mW max.
3.3V-24V
±6% max.
2%
LL-HL at full Load
±1% typ. / ±1.5% max.
2-100% Load
see Selection Guide
115VAC
15ms typ.
230VAC
80ms typ.
116% - 156%
at full Load
45kHz typ.
Input-Output
3kVAC / 1 minute
80-305VAC / 47-440Hz
10uA max.
1G Ω min
Continuous, Auto Restart
Zener clamp, set at 4.4V-5.0V for 3.3V and others
112-140% of its nominal output voltage
OVC II
natural convection, without derating
-25°C to +75°C
natural air convection, with derating
-25°C to +85°C
-40°C to +85°C
UL94V-0 black plastic
Silicon
95% RH max.
28g
12 pcs
TA = 25°C
> 1000x10³ hours
TA = 75°C
> 100x10³ hours
Dimension (LxWxH)
38.25 x 24.35 x 17.40 mm
EN55022, Class B
Report: T120816N04-E
EN55024
Report: SPCLVD1208051
Report: E224736-A17-UL
IEC/EN-60950-1
UL-60950-1
continued on next page
REV: 0/2015
RoHS
2011/65/EU
6/6
E224736
EN-60950-1 Certified
UL-60950-1 Certified
RAC03-SC/277
Derating-Graph
(Ambient Temperature)
120
100
Output Power (%)
Input Voltage Range (with Derating)
Input Frequency
Input Current (full Load)
Inrush Current
No Load Power Consumption
Output Voltage (Vout nom.)
Output Voltage Tolerance
Minimum Load
Line Voltage Regulation
Load Voltage Regulation
Hold-up Time
80
50
Safe Operating Area
60
40
20
0
-25
60 70 80 100
75 85
Ambient Temperature Range (°C)
0
20
40
Refer to Application Notes
www.recom-power.com
RAC03-xxSC/277
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Notes:
Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM for detailed information.
Note3: „Total Regulation“ is the output voltage tolerance which includes initial voltage precise, thermal drift, line regulation and load regulation at rated input
voltage and load condition.
Note4: . „Ripple & Noise“ is maximum peak-to-peak voltage value measured at output within 20MHz bandwidth at rated line voltage and output load ranges, and
with a 47 µF low-ESR electrolytic capacitor in parallel with a 0.1 µF ceramic capacitor across the output.
Note5: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
Output V-I Characteristic
Input Voltage Derating Graph
105
Vnom
85V, 100%
Vo
Load (%)
305V, 100%
40%
80V, 95%
80
100%
0%
Load (%)
Safe Operating Area
80
130
180
230
280
Input Voltage (VAC) Ta=25°C
Overcurrent
Limit
RAC03-SC/277
Package Style and Pinning
38.25
24.35
17.4+0.25
-
Pin Connections
5
6.10
0.75+0.25
1
5.08
1
20.32
2.54
1.20
5.08
3
+0.2/-0.1
16
13
Bottom View
14
Single Out
1
VAC in (L)
3
VAC in (N)
13
NC
14
-VDC out
16
+VDC out
Tolerance ±0.5mm unless otherwise
specified
Top View
17.78
16
14
Pin #
1
3
13
2.54
Recommendend Footprint Details
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
PA-9