RAC04-C/230 - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
●
POWERLINE
Universal Input 80-264VAC
100mW max No load Power Consumption
Efficiency up to 79%
High Operating Temperature Range
(-40°C to +80°C)
Isolated Output 3.75kVAC / 1 min
Continuous Short Circuit Protection
Meet EN55022 Class B
EN, UL and CE Certified
AC/DC-Converter
with 3 year Warranty
4 Watt
Single &
Dual Output
The RAC04-C/230 series are fully certified single and dual regulated
AC/DC converters in an encapsulated PCB-mount package style with
3.75kVAC isolation and very low standby power consumption. The
converters have SC protected single as well as dual outputs and meet
EN55022 class B without any external components. Uses include
board-level power supplies, home automation, instrumentation
systems and standby applications.
Description
Selection Guide
Part
Number
Input
Voltage
(VAC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(Typ.)
(%)
Max.
Capacitive
Load**
RAC04-3.3SC/230
80-264
3.3
1200
72
10000μF
RAC04-05SC/230
80-264
5
800
75
7200μF
RAC04-12SC/230
80-264
12
333
77
1000μF
RAC04-15SC/230
80-264
15
267
78
820μF
RAC04-24SC/230
80-264
24
167
79
220μF
5/12
720/33
75
4700/100μF
80-264
±5
±400
76
±3300μF
RAC04-12DC/230
80-264
** measured @115VAC
±12
±166
78
±680μF
RAC04-0512DC/230 80-264
RAC04-05DC/230
RoHS
2011/65/EU
6/6
E224736
EN-60950-1 certified
UL-60950-1 certified
RAC04-C/230
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range (with Derating)
80-264VAC or 113-373VDC
47-440Hz
Input Current (Full Load)
115VAC/230VAC
98mA / 64mA max.
Inrush Current
115VAC/230VAC
15A / 30A max.
No Load Power Consumption
Output Voltage Accuracy (Full Load)
115VAC/230VAC 50/60Hz
100mW max.
Single Outputs
±2% typ.
Dual Outputs
±2% typ.
5V / 12V
Line Voltage Regulation (90-264VAC)
±2% / ±10% typ.
Single Outputs
±0.2% typ.
Dual Outputs
±0.2% typ.
5V / 12V
Load Voltage Regulation
(10% - 100% load)
±0.2% / ±1% typ.
3.3V/5V Output
±1% typ.
All Others
±0.5% typ.
5V / 12V
±1% / ±5% typ.
Output Ripple&Noise
200mVp-p typ.
(measured @ 20MHz of bandwidth with 0.1μF & 47μF parallel capacitors)
Switching Frequency (Full Load)
Hold-Up Time
67kHz typ.
115VAC
Derating-Graph
(Ambient Temperature)
100
80
Load (%)
Input Frequency
Safe Operating Area
60
50
40
20
0
-40
-20
0
20
40
80
60
65
Ambient Temperature Range (°C)
15ms min.
Minimum Load
0%
Isolation Voltage
Input-Output
Leakage Current
230VAC / 50Hz
3.75kVAC / 1minute
0.25mA max.
100M Ω min.
Isolation Resistance
continued on next page
PA-20
REV: 0/2015
www.recom-power.com
RAC04-xxxC/230
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Short Circuit Protection
Auto Recovery
Over Voltage Category
OVC II
Operating Temperature Range
-40°C to +65°C (without Derating)
Natural Convection
-40°C to +80°C
Storage Temperature Range
(with Derating)
-40°C to +100°C
Case Material
UL94V-0 Black Plastic
Relative Humidity
Non-condensing
95% RH max.
Package Weight
31.5g typ.
Dimension
(L x W x H)
EMC
36.7 x 27.2 x 17.1mm
Conducted and Radiated
EN55022 Class B
Noise Immunity
MTBF (+25°C)
EN55024
MIL-HDBK-217F
500 x 10³ hours
CE
EN55022 Class B
Certification
UL General Safety
Report: E224736
EN General Safety
Report: SPCLVD1210098
UL60950-1, 2nd Edition
EN60950-1, 2nd Edition + A12:2011
Efficiency vs Load
Single Output 115VAC
Dual Output 115VAC
90
24SC
15SC
12SC
05SC
3.3SC
80
70
Efficiency (%)
60
50
40
30
60
50
40
30
20
20
10
10
0
0
10
20
30
40
50
60
70
80
90
12DC
05DC
0512DC
80
RAC04C/230
Efficiency (%)
70
90
0
100
0
10
20
30
40
Single Output 230VAC
60
50
40
30
40
30
10
0
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Load (%)
Load (%)
www.recom-power.com
05DC
12DC
0512DC
50
10
40
100
60
20
30
90
70
20
20
80
80
Efficiency (%)
Efficiency (%)
70
10
70
90
24SC
15SC
12SC
05SC
3.3SC
80
0
60
Dual Output 230VAC
90
0
50
Load (%)
Load (%)
REV: 0/2015
PA-21
RAC04-xxxC/230
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Application Note:
100
L
Fuse 1A
0.1uF/50V
Vout+
VAC (L)
Load
N
60
SAFE OPERATING AREA
40
47uF/50V
1. Recommended external input fuse 1A/slow blow type.
2. To measure the output ripple & noise connect 0.1uF/50V & 47uF/50V @20MHz,
as close to pins as possible with nominal input and full load. Please see above.
20
0
Vout-
VAC (N)
RAC04/230
Output Power (%)
80
80 90 100 115
230 264
Input Voltage (VAC)
Package Style and Pinning
27.2
26.5
RAC04C/230
36.7
36.0
17.1
4.0
21.0
0.6
21.5
3.1
7
6
21.0
Pin Connections
7.5
Pin #
5
Bottom View
1
2 3 4
Primary
Isolation
Spacing
Secondary
Single Out
Dual Output
Dual Output
1
No Pin
No Pin
No Pin
2
+VDC out
+Vout
+Vout
3
-VDC out
Com
Com
4*
NC
-Vout
+12V
5
VAC in (L)
VAC in (L)
VAC in (L)
6
VAC in (N)
VAC in (N)
VAC in (N)
7*
NC
NC
NC
NC = No Connection
3.8
21.5
3.75x2
xx.x = ±0.5mm
xx.xx = ±0.25mm
* Pins 4 and 7 are NC but need 4mm minimum clearence to ground for safety.
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-22
REV: 0/2015
www.recom-power.com